Honeywell RCW3506N Support and Manuals
Get Help and Manuals for this Honeywell item
This item is in your list!
View All Support Options Below
Free Honeywell RCW3506N manuals!
Problems with Honeywell RCW3506N?
Ask a Question
Free Honeywell RCW3506N manuals!
Problems with Honeywell RCW3506N?
Ask a Question
Popular Honeywell RCW3506N Manual Pages
Owner's Manual - Page 1
Installation Instructions
RCW35 and RCW25 Series (51366SL)
Decorative Wired Chimes RCW250N, RCW251N, RCW35N, RCW3501N, RCW3502N, RCW3503N, RCW3504N, RCW3505N, RCW3506N
69-2173EFS_B.indd 1
69-2173EFS-03
4/17/2008 11:15:45 AM
Owner's Manual - Page 2
transformer powered...8 Wiring - Installation Instructions
Contents Safety...3 Checking pack contents...4 Installation...5 Power supply...6 Mount the chime...7 Wiring - battery powered...10 Operate Push...11 Volume control...11 Change tunes...12 Program button...14 Finishing the wood cover...15 Specifications...16 Troubleshooting...17 Disposal and recycling...18 Guarantee...18 Declaration...18...
Owner's Manual - Page 3
VOLUME CONTROL CHANNEL INDICATOR LED
WIRE CONNECTION PORT/TERMINAL HOLE FOR CABLE/WIRE ENTRY OPTIONAL POWER WITH FOUR x LR14C ALKALINE BATTERIES
WIRED CHIME BASE
69-2173EFS_B.indd 1
RCW35 Series and RCW25 Series
PROGRAM BUTTON
TUNE BUTTON
LOW BATTERY LED
DECORATIVE CHIME COVER
SOLD SEPARATELY FROM
RCW35N
M27274
M27254
69-2173EFS-03
4/17/2008 11:15:45 AM
Owner's Manual - Page 4
Installation Instructions
Compatible with most bell pushes, with standard normally open contacts, including Honeywell wired pushes marked with up to 3 push circuits. Can work with "B." Illuminated bell push buttons can be used when the chime is powered by a transformer (Honeywell RCA900N).
69-2173EFS-03
69-2173EFS_B.indd 2
4/17/2008 11:15:45 AM
Owner's Manual - Page 5
... can expose chime to excessive heat such as sunshine, fire or the like; Replace only with the installation, please note the following safety warnings:
• Always follow the manufacturer's advice...when using power tools and wear suitable protective equipment (e.g. Batteries (battery pack or batteries installed) shall not be exposed to splashing or dripping liquid. • Use UL approved ...
Owner's Manual - Page 6
Installation Instructions
Checking Pack Contents • Chime • 2 x fixing screws for chime • 2 x wall plugs
You will need: • Wired push • 20 AWG minimum bell wire • 4 mm cross-head screwdriver • A small flat bladed screwdriver • 1/4-in. (6 mm) masonry drill bit • 4 x LR14 'C' Alkaline batteries OR transformer (16V 10 VA) Honeywell part number...
Owner's Manual - Page 7
Open the chime cover
RCW35 Series and RCW25 Series
69-2173EFS_B.indd 5
M27275
69-2173EFS-03
4/17/2008 11:15:45 AM Installation 1.
Owner's Manual - Page 8
Use 4 x LR14 'C' size alkaline batteries; OR a 16V, 10VA transformer as recommended in the table below below:
69-2173EFS-03
69-2173EFS_B.indd 6
ATTENTION! ATTENTION! ¡ATENCIÓN!
T 16 V~
1
2
3
M27276
4/17/2008 11:15:45 AM Determine the type of power supply and type of wired push required to suit your installation. Installation Instructions
Power Supply
2.
Owner's Manual - Page 12
Wiring for
standard (non-lighted) push only.
Installation Instructions
4b. Battery powered - x 1
Note: Wire/cable length should not exceed 150 ft. (50 m).
69-2173EFS-03
10
69-2173EFS_B.indd 10
x 3
AC V/AC C1 C2 C3 1 2 3 M27281
4/17/2008 11:15:46 AM
Owner's Manual - Page 14
Alert
69-2173EFS-03
12
69-2173EFS_B.indd 12
4/17/2008 11:15:46 AM Chime tunes are provided plus an additional alert tone. Tunes Table Ding Dong
St Clements
Westminster
Tube Chime
Warm Brass
Fantasy
! Installation Instructions To Change Tune
7.
Owner's Manual - Page 16
... LED for the related push illuminates. The chime will play the latest tune, channel LED will illuminate in sequence. Press and hold the program button l. Installation Instructions
Program Button
8. The channel LED will flash. The Program button can be used .
69-2173EFS-03
14
69-2173EFS_B.indd 14
4/17/2008 11:15...
Owner's Manual - Page 18
Installation Instructions
Specification Operating Temperature Sound Level (typical) Power Supply
Battery Life (if applicable) (5 operations/day)
Chime
32°F to 104°F 0°C to +40°C
90dBA @ 3 ft (1m)
4 x LR14 C size alkaline batteries OR 16V 10VA transformer (UL approved) Honeywell part number RCA900N
12 months
69-2173EFS-03
16
69-2173EFS_B.indd 16
4/17/2008 11:15:46 AM
Owner's Manual - Page 19
... according to step 4, using batteries: • Check that the wiring is low, an amber LED located at the minimum setting. Install
new batteries in the chime, type LR14 'C' cells. RCW35 Series and RCW25 Series
Troubleshooting
When the illuminated bell push is operated, very dim / no light appears on flashing... • The push associated...
Owner's Manual - Page 20
Guarantee Honeywell guarantees this product for 1 year from the date of with Part 15 of purchase is subject to operate the equipment. If you require further ...call the Honeywell helpline at 1-800-468-1502. Cet appareil numérique de la class B est conforme á la norme NMB-003 du Canada.
69-2173EFS-03
18
69-2173EFS_B.indd 18
4/17/2008 11:15:46 AM Installation Instructions
Disposal & ...
Owner's Manual - Page 22
ACS, Environmental and Combustion Controls 1985 Douglas Drive, Golden Valley, MN 55422 www.honeywell.com
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
® U.S. Rev. 04-08
69-2173EFS_B.indd 20
4/17/2008 11:15:47 AM Registered Trademark. © 2008 Honeywell International Inc. 69-2173EFS-03 M.S. Honeywell International Inc.
Honeywell RCW3506N Reviews
Do you have an experience with the Honeywell RCW3506N that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Honeywell yet.
Earn 750 points for your review!