Installation Instructions
Page 1
... DC output failure indication by Red LED (L2). 14. B) Distribution Controller Board • Output (not supervised) - 6 Fail Safe or Fail Secure Continued on AC failure. 6. This product must be used with Card Access Systems. It provides 12/24VDC through 6 power-limited outputs. Input voltage...two (2) Fire inputs, N/O or N/C, and Reverse Polarity triggered by Red LED ( L5 ). 17. Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP300ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52387:A 12/29/05 ECN 04-350 Product ...
... DC output failure indication by Red LED (L2). 14. B) Distribution Controller Board • Output (not supervised) - 6 Fail Safe or Fail Secure Continued on AC failure. 6. This product must be used with Card Access Systems. It provides 12/24VDC through 6 power-limited outputs. Input voltage...two (2) Fire inputs, N/O or N/C, and Reverse Polarity triggered by Red LED ( L5 ). 17. Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP300ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52387:A 12/29/05 ECN 04-350 Product ...
Installation Instructions
Page 2
...is triggered. Fail Safe operation devices such as Magnetic Locks should be connected to this output. 2.) For Fail Secure operation connect device positive to supervise this connection. 5. Fail Secure operation devices such as shown in accordance with 2.2 K Ohm (EOL) resistor. • Alarm Outputs -...49C. - - Red LED for correct installation (see Fig. 1). When FACP activation occurs dry contacts activated. - Mount the power supply securely in either case connect device negative to Neg terminal on HPMOM5. 1.) For Fail Safe operation connect device positive to the "FIRE INTRFC" ...
...is triggered. Fail Safe operation devices such as Magnetic Locks should be connected to this output. 2.) For Fail Secure operation connect device positive to supervise this connection. 5. Fail Secure operation devices such as shown in accordance with 2.2 K Ohm (EOL) resistor. • Alarm Outputs -...49C. - - Red LED for correct installation (see Fig. 1). When FACP activation occurs dry contacts activated. - Mount the power supply securely in either case connect device negative to Neg terminal on HPMOM5. 1.) For Fail Safe operation connect device positive to the "FIRE INTRFC" ...
Installation Instructions
Page 3
... "AC Fail" output "Form C" dry contacts to the monitoring device. For 24VDC use a Tamper Switch (Catalog number HPVM3 available separately), and included enclosure key lock. Secure the enclosure with the 4 screws and with the Key Lock provided. AC present Red LED - battery low or disconnected Red LED - Install the 2.2K Ohm...
... "AC Fail" output "Form C" dry contacts to the monitoring device. For 24VDC use a Tamper Switch (Catalog number HPVM3 available separately), and included enclosure key lock. Secure the enclosure with the 4 screws and with the Key Lock provided. AC present Red LED - battery low or disconnected Red LED - Install the 2.2K Ohm...