Installation Guide, Third Edition - HP rp5400 Family of Servers
Page 7
...42.19 or later. Power down and unplug the rp54xx Server. Chapter 1 7 rp5470 slots 0, 2, 1, 3 • For rp5400 and rp5450 single CPU configurations, a processor terminator must be installed in slot 3. Installing Additional Components Installing Central Processing Units (CPUs) Installing Central Processing Units (...and rp5470. rp5400 slots 0, 3 - Do not install or service rp54xx internal components while DC voltage is 42.19 or later. Make the top of two CPUs. Ensure that the following conditions are met before installing a 750 MHz CPU (A6805B): • HP-UX 11.0/11...
...42.19 or later. Power down and unplug the rp54xx Server. Chapter 1 7 rp5470 slots 0, 2, 1, 3 • For rp5400 and rp5450 single CPU configurations, a processor terminator must be installed in slot 3. Installing Additional Components Installing Central Processing Units (CPUs) Installing Central Processing Units (...and rp5470. rp5400 slots 0, 3 - Do not install or service rp54xx internal components while DC voltage is 42.19 or later. Make the top of two CPUs. Ensure that the following conditions are met before installing a 750 MHz CPU (A6805B): • HP-UX 11.0/11...
Installation Guide, Third Edition - HP rp5400 Family of Servers
Page 9
The following outlines which CPUs and processor support modules are installed for which rp5400 and rp5450 CPU configurations. PSM 0 CPU 1 CPU 0 CPU 2 CPU 3 Number of CPUs One Two Threea Foura PSM 1 L1000/L2000 System Board CPU Numbers to be Installed 0 0 and 3 0, 1, and 3 0, 1, 2, and 3 PSM Numbers to the next step. If installing on an rp5470 proceed to be Installed 0 0 0 and 1 0 and 1 Chapter 1 9 Installing Additional Components Installing Central Processing Units (CPUs) Step 5.
The following outlines which CPUs and processor support modules are installed for which rp5400 and rp5450 CPU configurations. PSM 0 CPU 1 CPU 0 CPU 2 CPU 3 Number of CPUs One Two Threea Foura PSM 1 L1000/L2000 System Board CPU Numbers to be Installed 0 0 and 3 0, 1, and 3 0, 1, 2, and 3 PSM Numbers to the next step. If installing on an rp5470 proceed to be Installed 0 0 0 and 1 0 and 1 Chapter 1 9 Installing Additional Components Installing Central Processing Units (CPUs) Step 5.
Installation Guide, Third Edition - HP rp5400 Family of Servers
Page 10
... to be Installed 0 0 0 and 1 0 and 1 Step 7. If installing a second CPU, on rp5400 or rp5450, remove the processor terminator in the Removal and Replacement chapter. Perform CPU Socket Cleaning Procedure detailed in slot 3. 10 Chapter 1 Installing Additional Components Installing Central Processing Units (CPUs) Step 6. PSM 0 CPU 1 CPU 0 CPU 2 CPU 3 PSM 1 L3000 System Board Number of Processors Installed One...
... to be Installed 0 0 0 and 1 0 and 1 Step 7. If installing a second CPU, on rp5400 or rp5450, remove the processor terminator in the Removal and Replacement chapter. Perform CPU Socket Cleaning Procedure detailed in slot 3. 10 Chapter 1 Installing Additional Components Installing Central Processing Units (CPUs) Step 6. PSM 0 CPU 1 CPU 0 CPU 2 CPU 3 PSM 1 L3000 System Board Number of Processors Installed One...
Troubleshooting and Build-Up Procedures Product Update - rp5400, rp5430, rp5450 and rp5470
Page 6
...as a platform monitor code translates to: • Source -> 4 = power • Caller Activity -> 4 = monitor Assuming that fails to enter CPU self-test with the addition of the system can be a processor support module power supply in the processor 0 and processor 3 locations-before the runway bus... [PSMs]) and the system card. Then replace one or both processors (or alternatively replace processor 3 with a processor power dipswitch (e.g. rp5400, rp5430, rp5450 and rp5470 Troubleshooting and Build-Up Procedures System Will Power On but Will Not Enter Self-Test Once access to the GSP...
...as a platform monitor code translates to: • Source -> 4 = power • Caller Activity -> 4 = monitor Assuming that fails to enter CPU self-test with the addition of the system can be a processor support module power supply in the processor 0 and processor 3 locations-before the runway bus... [PSMs]) and the system card. Then replace one or both processors (or alternatively replace processor 3 with a processor power dipswitch (e.g. rp5400, rp5430, rp5450 and rp5470 Troubleshooting and Build-Up Procedures System Will Power On but Will Not Enter Self-Test Once access to the GSP...
Troubleshooting and Build-Up Procedures Product Update - rp5400, rp5430, rp5450 and rp5470
Page 7
rp5400, rp5430, rp5450 and rp5470 Troubleshooting and Build-Up Procedures System Will Not Pass Self-test System Will Not Pass Self-test In cases where the system will power up and initiate CPU self-test but will consistently not pass self-test and/or boot to boot console handler (BCH...On an operational system with a processor Chapter 1 7 If the above VFP output is equipped with these parts removed, the VFP output will result in CPU 3's slot position). If Step 1 does not appear to the point of testing memory for changes in one or more processor modules. Q/q: quit Virtual Front...
rp5400, rp5430, rp5450 and rp5470 Troubleshooting and Build-Up Procedures System Will Not Pass Self-test System Will Not Pass Self-test In cases where the system will power up and initiate CPU self-test but will consistently not pass self-test and/or boot to boot console handler (BCH...On an operational system with a processor Chapter 1 7 If the above VFP output is equipped with these parts removed, the VFP output will result in CPU 3's slot position). If Step 1 does not appear to the point of testing memory for changes in one or more processor modules. Q/q: quit Virtual Front...
User Guide - HP rp5400 Family of Servers
Page 102
... Normal Functioning Indicators Troubleshooting Steps Potential FRUs System won't power on when Front Panel Power switch is turned on SOLID. 1. The failing CPU support module is lit. 6. Check for rp5400). Ensure there are 2 working power supplies (1 supply for remote power shutdown via GSP>PC command. 2. Check that platform monitor power LED is...
... Normal Functioning Indicators Troubleshooting Steps Potential FRUs System won't power on when Front Panel Power switch is turned on SOLID. 1. The failing CPU support module is lit. 6. Check for rp5400). Ensure there are 2 working power supplies (1 supply for remote power shutdown via GSP>PC command. 2. Check that platform monitor power LED is...
User Guide - HP rp5400 Family of Servers
Page 106
...Platform 7 - Memory 8 - AC Mains N/A 3 - Cabinet Fan Fan # 6 - Service N/A Processor 7 - SIMM or N/A DIMM 6 - N/A CPU Replace the Support Processor Support Module Module (on the GSP I/O board. Various Values Disk Subsyste m Use BCH commands and ODE diagnostics to FRU Decoder (Continued...ME) and ODE memory diagnostic. Replace the GSP N/A Power Replace Platform Monitor Monitor card. Low Voltage DC Power CPU Support Module # 4 - N/A Core I /O Source Detail Source ID Not Applicable N/A (N/A) 1 - Power 4 - Memory 7 - N/A Fan Replace the...
...Platform 7 - Memory 8 - AC Mains N/A 3 - Cabinet Fan Fan # 6 - Service N/A Processor 7 - SIMM or N/A DIMM 6 - N/A CPU Replace the Support Processor Support Module Module (on the GSP I/O board. Various Values Disk Subsyste m Use BCH commands and ODE diagnostics to FRU Decoder (Continued...ME) and ODE memory diagnostic. Replace the GSP N/A Power Replace Platform Monitor Monitor card. Low Voltage DC Power CPU Support Module # 4 - N/A Core I /O Source Detail Source ID Not Applicable N/A (N/A) 1 - Power 4 - Memory 7 - N/A Fan Replace the...
User Guide - HP rp5400 Family of Servers
Page 113
... REPORTING ENTITY ID: 030x0000306030031710 00000000 000000FE type 0 = Data Field Unused0x5800386030031710 0000640B 08172E16 type 11 = Timestamp 12/08/2000 23:46:22Type CR for the installed CPU's. Step 2. Chapter 6 99 Step 3. This is an rp5450 so use Appendix B in the Interpreting Chassis Logs in Appendix B, we learn the definition is CC_BOOT_INVALID_SPHYR_SETTINGS...
... REPORTING ENTITY ID: 030x0000306030031710 00000000 000000FE type 0 = Data Field Unused0x5800386030031710 0000640B 08172E16 type 11 = Timestamp 12/08/2000 23:46:22Type CR for the installed CPU's. Step 2. Chapter 6 99 Step 3. This is an rp5450 so use Appendix B in the Interpreting Chassis Logs in Appendix B, we learn the definition is CC_BOOT_INVALID_SPHYR_SETTINGS...
User Guide - HP rp5400 Family of Servers
Page 114
... as function 0, connecting a disk as target 4, LUN 2- Troubleshooting rp5400 and rp5450 System Block Diagram rp5400 and rp5450 System Block Diagram 0/0/1/0.X External SCSI 0/0/1/1 100 rp5400/rp5450 Block Diagram Disabled for rp5400 48V input SHOTGUN PSM 0 Clock Sphyr-T Clock Sphyr-T 48V input PSM 1 PDH/PDC Dillion SYSTEM BOARD CPU 0 CPU 1 CPU 2 CPU 3 fffa_0000 fffa_2000 fffa_4000 fffa_6000 HW path 160 HW...
... as function 0, connecting a disk as target 4, LUN 2- Troubleshooting rp5400 and rp5450 System Block Diagram rp5400 and rp5450 System Block Diagram 0/0/1/0.X External SCSI 0/0/1/1 100 rp5400/rp5450 Block Diagram Disabled for rp5400 48V input SHOTGUN PSM 0 Clock Sphyr-T Clock Sphyr-T 48V input PSM 1 PDH/PDC Dillion SYSTEM BOARD CPU 0 CPU 1 CPU 2 CPU 3 fffa_0000 fffa_2000 fffa_4000 fffa_6000 HW path 160 HW...
User Guide - HP rp5400 Family of Servers
Page 116
... PM FRONT P AN EL AC DC POW ER CONV ERT ER P S0 FRONT END P S1 FRONT END P S2 FRONT END rp5430/70 System Block Diagram HP CONFIDENT IAL Updated 11/0 6/01 TW IN TU RBO PC I s lo t 1 2 Pa th 0 /1 0 /0 TW IN TU RBO PC I s lo t 1 1 Pa th 0 /1 2 /0 TURBO PC I s lot 10... DMC MID-X MIC-X MIA-X SMC Phy Loc f f f f _f f 71 M erce d B us 0 DEW Pa th 1 00 Pa th 9 6 H PA f ed64 0 00 HPA f e d6 0 00 0 Runway CPU 3 H PA f ed65000 H W Path 101 P h y Loc f f 0 3_f f 11 CPU 2 H PA f ed61000 H W Path 97 P h y Loc f f 0 2_f f 11 DEW Pa th 3 6 Pa th 3 2 H PA f e d2 40 0 0 HPA f ed20 0 00 R unway...
... PM FRONT P AN EL AC DC POW ER CONV ERT ER P S0 FRONT END P S1 FRONT END P S2 FRONT END rp5430/70 System Block Diagram HP CONFIDENT IAL Updated 11/0 6/01 TW IN TU RBO PC I s lo t 1 2 Pa th 0 /1 0 /0 TW IN TU RBO PC I s lo t 1 1 Pa th 0 /1 2 /0 TURBO PC I s lot 10... DMC MID-X MIC-X MIA-X SMC Phy Loc f f f f _f f 71 M erce d B us 0 DEW Pa th 1 00 Pa th 9 6 H PA f ed64 0 00 HPA f e d6 0 00 0 Runway CPU 3 H PA f ed65000 H W Path 101 P h y Loc f f 0 3_f f 11 CPU 2 H PA f ed61000 H W Path 97 P h y Loc f f 0 2_f f 11 DEW Pa th 3 6 Pa th 3 2 H PA f e d2 40 0 0 HPA f ed20 0 00 R unway...
User Guide - HP rp5400 Family of Servers
Page 229
...I/O Connections, 50 Core I/O Removal, 146 Core I/O Replacement, 147 CPU Removal, 182 CPU Socket Replacement, Cleaning, and CPU Replacement, 183 Cleaning Kit Components, 183 CPU Cleaning for System Board Replacement, 185, 186 Replacing the CPU, 187 Tools Required, 183 Cross-Referencing Chassis Log Errors to rp54xx FRUs...Media Backplane Replacement, 213 Disk Media Housing Removal, 188 Disk Media Housing Replacement, 189 Display Board Removal, 173, 174 Removing rp5400 and/or rp5450 Model Platform Monitors, 175 Removing The rp5470 Model Platform Monitor, 175 E Electrical, 245 Modular PDUs, 246 ...
...I/O Connections, 50 Core I/O Removal, 146 Core I/O Replacement, 147 CPU Removal, 182 CPU Socket Replacement, Cleaning, and CPU Replacement, 183 Cleaning Kit Components, 183 CPU Cleaning for System Board Replacement, 185, 186 Replacing the CPU, 187 Tools Required, 183 Cross-Referencing Chassis Log Errors to rp54xx FRUs...Media Backplane Replacement, 213 Disk Media Housing Removal, 188 Disk Media Housing Replacement, 189 Display Board Removal, 173, 174 Removing rp5400 and/or rp5450 Model Platform Monitors, 175 Removing The rp5470 Model Platform Monitor, 175 E Electrical, 245 Modular PDUs, 246 ...