HP DTC Cabling and Racking Guide
Page 107
... connector supports connection to connect via the 15-pin Attachment Unit Interface connector. Prior to LAN cable installation, check that the building's power installation complies with the path of lightning conductors, and they should preferably be undertaken while there is a likelihood of an outdoor section of buildings, especially roofing. 11 Supported LAN Cables and Transceivers Caution The DTC can be connected to a Local Area Network...
... connector supports connection to connect via the 15-pin Attachment Unit Interface connector. Prior to LAN cable installation, check that the building's power installation complies with the path of lightning conductors, and they should preferably be undertaken while there is a likelihood of an outdoor section of buildings, especially roofing. 11 Supported LAN Cables and Transceivers Caution The DTC can be connected to a Local Area Network...
HP DLPI Programmer's Guide
Page 11
... subscribe to correct errors or document product changes. Intended Audience This manual is printed. Table 1 shows the releases available for application developers using DLPI. The users are made at http://docs.hp.com. The printing date will change when a new edition is intended for HP-UX 11i. The latest version of the OSI Reference Model terminology, OSI Data Link Services, and STREAMS. HP-UX Release...
... subscribe to correct errors or document product changes. Intended Audience This manual is printed. Table 1 shows the releases available for application developers using DLPI. The users are made at http://docs.hp.com. The printing date will change when a new edition is intended for HP-UX 11i. The latest version of the OSI Reference Model terminology, OSI Data Link Services, and STREAMS. HP-UX Release...
Site Preparation Guide - rp5400
Page 10
... and temperature alarms • Fire extinguishing system Additional safety devices are: • Circuit breakers • An emergency power cutoff switch • Devices specific to power distribution system design and installation must have a thorough knowledge and understanding of appropriate electrical codes and the limitations of the power systems for equipment servicing) are installed or removed. 2 Chapter 1 Those responsible for an hp server requires specialized skills...
... and temperature alarms • Fire extinguishing system Additional safety devices are: • Circuit breakers • An emergency power cutoff switch • Devices specific to power distribution system design and installation must have a thorough knowledge and understanding of appropriate electrical codes and the limitations of the power systems for equipment servicing) are installed or removed. 2 Chapter 1 Those responsible for an hp server requires specialized skills...
Installation Guide, Third Edition - HP rp5400 Family of Servers
Page 12
... access all slots. Do not attempt to install or service: CPUs, memory, PSMs, the platform monitor or PCI I/O cards installed in the lowest slot numbers. • Install DIMMs the following slot order: 0a/b, 1a/b, 2a/b, 3a/b, and so on rp5400 Servers. Step 2. rp5470 Servers install DIMMs using memory carriers. The air baffle will be the same. • Install DIMMs with the greatest capacity in non-turbo slots (1-6) while DC voltage is connected to AC power. rp5400 and rp5450 Servers...
... access all slots. Do not attempt to install or service: CPUs, memory, PSMs, the platform monitor or PCI I/O cards installed in the lowest slot numbers. • Install DIMMs the following slot order: 0a/b, 1a/b, 2a/b, 3a/b, and so on rp5400 Servers. Step 2. rp5470 Servers install DIMMs using memory carriers. The air baffle will be the same. • Install DIMMs with the greatest capacity in non-turbo slots (1-6) while DC voltage is connected to AC power. rp5400 and rp5450 Servers...
Installation Guide, Third Edition - HP rp5400 Family of Servers
Page 19
... for HP-UX version 11.1 and later. 7. Not supported in slots 3 and 4 (shared slots). 11. Maximum is 10 for each additional card. 12. This product to 11.0. Card contains a PCI-to-PCI bridge. 2. Requires server firmware revision 39.46 or later. 5. Contains PCI bridge. Installing Additional Components Installing Peripheral Component Interconnect (PCI) Cards Product Number Description (all are installing ATM 622 cards in an rp5470 configuration, do not install them in shared slots...
... for HP-UX version 11.1 and later. 7. Not supported in slots 3 and 4 (shared slots). 11. Maximum is 10 for each additional card. 12. This product to 11.0. Card contains a PCI-to-PCI bridge. 2. Requires server firmware revision 39.46 or later. 5. Contains PCI bridge. Installing Additional Components Installing Peripheral Component Interconnect (PCI) Cards Product Number Description (all are installing ATM 622 cards in an rp5470 configuration, do not install them in shared slots...
Installation Guide, Third Edition - HP rp5400 Family of Servers
Page 75
... entry to be removed, you must change the data in the prompts for no. Access Level: Operator . At the GSP prompt, enter the Security options and access control (SO) command: GSP> so 3. Access the GSP with the same Security options and access control (SO) command used to add a user. Login Timeout: 1 minutes. . Cabling and Power-Up GSP Configurable Parameters CAUTION Be sure to read each user number until you reach...
... entry to be removed, you must change the data in the prompts for no. Access Level: Operator . At the GSP prompt, enter the Security options and access control (SO) command: GSP> so 3. Access the GSP with the same Security options and access control (SO) command used to add a user. Login Timeout: 1 minutes. . Cabling and Power-Up GSP Configurable Parameters CAUTION Be sure to read each user number until you reach...
Troubleshooting and Build-Up Procedures Product Update - rp5400, rp5430, rp5450 and rp5470
Page 8
...: 3 = local bus adapter SOURCE ID: FF PROBLEM DETAIL: 6 = configuration error LEDs: RUN ATTENTION FAULT REMOTE POWER FLASH OFF OFF ON ON LED State: Running non-OS code. (i.e. Insert or replace the core SCSI/LAN card and retest. If this entry - Alternatively, you cannot get to BCH at least one pair of memory DIMMs in their proper DIMM slots and retest. type 4 = Physical Location 0x5800086683FF2164 00006600 0F14272C - It should boot successfully to BCH and BCH commands could...
...: 3 = local bus adapter SOURCE ID: FF PROBLEM DETAIL: 6 = configuration error LEDs: RUN ATTENTION FAULT REMOTE POWER FLASH OFF OFF ON ON LED State: Running non-OS code. (i.e. Insert or replace the core SCSI/LAN card and retest. If this entry - Alternatively, you cannot get to BCH at least one pair of memory DIMMs in their proper DIMM slots and retest. type 4 = Physical Location 0x5800086683FF2164 00006600 0F14272C - It should boot successfully to BCH and BCH commands could...
User Guide - HP rp5400 Family of Servers
Page 47
... an rp5470 configuration, do not install them in slots 3 and 4 (shared slots). 11. Notes: 1. If you are PCI cards) J3525A J3593A J3592A A6150A A6150BX A6386A A5506A A6749A A6748A Dual Port Synchronous Adapter 64 port Serial MUX system card 8 Port PCI Serial MUX card Graphics, USB Card Pinnacle 2 Graphics Hyper Fabric 2 Interconnect Quad Port 10/100B-TX LAN 3.3v 64 Port Terminal MUX 3.3v 8 Port Terminal MUX Max Boot Load Order * Part Number 10 No...
... an rp5470 configuration, do not install them in slots 3 and 4 (shared slots). 11. Notes: 1. If you are PCI cards) J3525A J3593A J3592A A6150A A6150BX A6386A A5506A A6749A A6748A Dual Port Synchronous Adapter 64 port Serial MUX system card 8 Port PCI Serial MUX card Graphics, USB Card Pinnacle 2 Graphics Hyper Fabric 2 Interconnect Quad Port 10/100B-TX LAN 3.3v 64 Port Terminal MUX 3.3v 8 Port Terminal MUX Max Boot Load Order * Part Number 10 No...
User Guide - HP rp5400 Family of Servers
Page 48
... 2 GSP GSP GSP 1 LAN/SCSI LAN/SCSI LAN/SCSI a. b. Do not attempt to install or service: CPUs, Memory, PSMs, the Platform Monitor or PCI I /O slots are available and the corresponding paths. Failure to install a PCI card. Using a Torx 15 screwdriver, loosen the captive screws on the right side panel. Step 1. Slot is connected to the server. NOTE DC voltages are shown below. This panel has a label which shows which PCI I /O cards installed in damage to AC power.
... 2 GSP GSP GSP 1 LAN/SCSI LAN/SCSI LAN/SCSI a. b. Do not attempt to install or service: CPUs, Memory, PSMs, the Platform Monitor or PCI I /O slots are available and the corresponding paths. Failure to install a PCI card. Using a Torx 15 screwdriver, loosen the captive screws on the right side panel. Step 1. Slot is connected to the server. NOTE DC voltages are shown below. This panel has a label which shows which PCI I /O cards installed in damage to AC power.
User Guide - HP rp5400 Family of Servers
Page 84
...'s Name: IT Support . User's Name: Joe Smith . Dial-back configuration: Disabled . NOTE You will see with removing a user. The Mode entry of the user to be removed. 4. To remove users, respond N for that user. Access the GSP with the same Security options and access control (SO) command used to read each user number until you must change the data in the prompts for no. User's state: enabled For the number 1 user, the Access level is for...
...'s Name: IT Support . User's Name: Joe Smith . Dial-back configuration: Disabled . NOTE You will see with removing a user. The Mode entry of the user to be removed. 4. To remove users, respond N for that user. Access the GSP with the same Security options and access control (SO) command used to read each user number until you must change the data in the prompts for no. User's state: enabled For the number 1 user, the Access level is for...
User Guide - HP rp5400 Family of Servers
Page 105
... Detail guide. Cross-Referencing Chassis Log Errors to rp54xx FRUs Use the following information: • Cross-Referencing Chassis Log Errors to determine which processor is not functioning. Processor Not Applicable N/A Cache (N/A) Problem Detail FRU Action to Take N/A Processor From BCH Main Menu go to the Info Menu and execute the PR command to -FRU Decoder utility. 1. Chapter 6 91 The guide includes the following table to identify the failing...
... Detail guide. Cross-Referencing Chassis Log Errors to rp54xx FRUs Use the following information: • Cross-Referencing Chassis Log Errors to determine which processor is not functioning. Processor Not Applicable N/A Cache (N/A) Problem Detail FRU Action to Take N/A Processor From BCH Main Menu go to the Info Menu and execute the PR command to -FRU Decoder utility. 1. Chapter 6 91 The guide includes the following table to identify the failing...
User Guide - HP rp5400 Family of Servers
Page 106
.../O board. Low Voltage DC Power CPU Support Module # 4 - SIMM or N/A DIMM 6 - Power 6 - AC Mains N/A 3 - Service N/A Processor 7 - N/A System Replace the System Board Board. Platform 6 - Disk N/A Problem Detail FRU Action to FRU Decoder (Continued) Chassis Log Field Values and Descriptions from Log Entry Source 3 - N/A Core I/O The Service Processor is being supplied to all power supplies. Various Values Disk Subsyste m Use BCH commands and ODE diagnostics to failing DIMM DIMM using BCH (IN, ME) and ODE memory diagnostic. Power 4 - Cabinet Fan Fan...
.../O board. Low Voltage DC Power CPU Support Module # 4 - SIMM or N/A DIMM 6 - Power 6 - AC Mains N/A 3 - Service N/A Processor 7 - N/A System Replace the System Board Board. Platform 6 - Disk N/A Problem Detail FRU Action to FRU Decoder (Continued) Chassis Log Field Values and Descriptions from Log Entry Source 3 - N/A Core I/O The Service Processor is being supplied to all power supplies. Various Values Disk Subsyste m Use BCH commands and ODE diagnostics to failing DIMM DIMM using BCH (IN, ME) and ODE memory diagnostic. Power 4 - Cabinet Fan Fan...
User Guide - HP rp5400 Family of Servers
Page 107
.... SOURCE ID: 00 PROBLEM DETAIL: 3=functional failure - Power Supply Failure Example Troubleshooting Chassis Code to FRU Decode GSP> sl SL Which buffer are you interested in : Incoming, Activity, Error, Current boot or Last boot ? (I/A/E/C/L) e e Do you want to set up filter options on this row is not applicable. CR and CR to replace Power Supply #2, located in time), Type - CALLER SUBACTIVITY: 04=low voltage power supply SOURCE: 4=power - ACTIVITY STATUS: F Data 0 : Low=00000000...
.... SOURCE ID: 00 PROBLEM DETAIL: 3=functional failure - Power Supply Failure Example Troubleshooting Chassis Code to FRU Decode GSP> sl SL Which buffer are you interested in : Incoming, Activity, Error, Current boot or Last boot ? (I/A/E/C/L) e e Do you want to set up filter options on this row is not applicable. CR and CR to replace Power Supply #2, located in time), Type - CALLER SUBACTIVITY: 04=low voltage power supply SOURCE: 4=power - ACTIVITY STATUS: F Data 0 : Low=00000000...
User Guide - HP rp5400 Family of Servers
Page 108
... Service Processor Error Logs. These alerts are reported to the system console when a problem is the output of the BCH Main Menu to identify the failing processor. The Source Detail, the Source ID, and the Problem Detail values are all system information Display boot-related information Display cache information Display revisions of major VLSI Display coprocessor information Display FRU information Display firmware version Display I/O interface information Display Core LAN station address Display memory information Display processor information Display selftest warning messages...
... Service Processor Error Logs. These alerts are reported to the system console when a problem is the output of the BCH Main Menu to identify the failing processor. The Source Detail, the Source ID, and the Problem Detail values are all system information Display boot-related information Display cache information Display revisions of major VLSI Display coprocessor information Display FRU information Display firmware version Display I/O interface information Display Core LAN station address Display memory information Display processor information Display selftest warning messages...
User Guide - HP rp5400 Family of Servers
Page 109
... problem - Replace fan #4 to (i.e, cabinet fan, DIMM, high voltage DC power, etc...). Chapter 6 95 type 0 = Data Field Unused 0x582008646304405F 00006303 0F151D08 - Responding with the letter A will continue operating. 2. SOURCE ID: 04 SYSTEM NAME: fesrhapgsp MODEL NAME: MODEL STRING: S/N: SPU POWER: ON ACTIVITY/COMPLETION LEVEL: 0% SYSTEM BOOT IS PENDING LEDs: RUN FLASH ATTENTION OFF FAULT OFF REMOTE ON CALLER ACTIVITY: 4=monitor - The fan failed on April 15, 1999 at 9:29 PM. A - Problem Detail: Timestamp: Specific problem...
... problem - Replace fan #4 to (i.e, cabinet fan, DIMM, high voltage DC power, etc...). Chapter 6 95 type 0 = Data Field Unused 0x582008646304405F 00006303 0F151D08 - Responding with the letter A will continue operating. 2. SOURCE ID: 04 SYSTEM NAME: fesrhapgsp MODEL NAME: MODEL STRING: S/N: SPU POWER: ON ACTIVITY/COMPLETION LEVEL: 0% SYSTEM BOOT IS PENDING LEDs: RUN FLASH ATTENTION OFF FAULT OFF REMOTE ON CALLER ACTIVITY: 4=monitor - The fan failed on April 15, 1999 at 9:29 PM. A - Problem Detail: Timestamp: Specific problem...
User Guide - HP rp5400 Family of Servers
Page 110
... failure or environmental problem - User input is an example of accessing the Error Logs from the Boot Console Handler (BCH) Main Menu prompt. At the system console prompt, type CTRL B 2. The screen will display: Which buffer are the ones you interested in ITALICS. The screen will display: GSP> At the GSP> prompt: type SL and press enter 4. Main Menu: Enter command or menu > type CTRL B Service Processor login: System Operator Service Processor password: ****** (password hidden...
... failure or environmental problem - User input is an example of accessing the Error Logs from the Boot Console Handler (BCH) Main Menu prompt. At the system console prompt, type CTRL B 2. The screen will display: Which buffer are the ones you interested in ITALICS. The screen will display: GSP> At the GSP> prompt: type SL and press enter 4. Main Menu: Enter command or menu > type CTRL B Service Processor login: System Operator Service Processor password: ****** (password hidden...
User Guide - HP rp5400 Family of Servers
Page 146
... susceptible to EMI problems. Set the air baffle in place. Seat the top cover in the top of the top cover with the corresponding slots in the chassis and seat the tabs fully into the slots. 2. The following graphics show the air baffle and the top service bay cover. Removing and Replacing Components Individual Component Remove/Replace Instructions Top Cover Replacement The power to the server does not...
... susceptible to EMI problems. Set the air baffle in place. Seat the top cover in the top of the top cover with the corresponding slots in the chassis and seat the tabs fully into the slots. 2. The following graphics show the air baffle and the top service bay cover. Removing and Replacing Components Individual Component Remove/Replace Instructions Top Cover Replacement The power to the server does not...
User Guide - HP rp5400 Family of Servers
Page 229
... LAN Port via an ASCII console, 61 Configuring the Rev A Guardian Service Processor (GSP), 80 Configuring the Rev B Guardian Service Processor (GSP), 83 Core I/O Connections, 50 Core I/O Removal, 146 Core I/O Replacement, 147 CPU Removal, 182 CPU Socket Replacement, Cleaning, and CPU Replacement, 183 Cleaning Kit Components, 183 CPU Cleaning for System Board Replacement, 185, 186 Replacing the CPU, 187 Tools Required, 183 Cross-Referencing Chassis Log Errors to rp54xx FRUs, 93 CRU Physical Location, 216 Customer Replaceable Unit Part Numbers, 219 D Data Communications Cables...
... LAN Port via an ASCII console, 61 Configuring the Rev A Guardian Service Processor (GSP), 80 Configuring the Rev B Guardian Service Processor (GSP), 83 Core I/O Connections, 50 Core I/O Removal, 146 Core I/O Replacement, 147 CPU Removal, 182 CPU Socket Replacement, Cleaning, and CPU Replacement, 183 Cleaning Kit Components, 183 CPU Cleaning for System Board Replacement, 185, 186 Replacing the CPU, 187 Tools Required, 183 Cross-Referencing Chassis Log Errors to rp54xx FRUs, 93 CRU Physical Location, 216 Customer Replaceable Unit Part Numbers, 219 D Data Communications Cables...
User Guide - HP rp5400 Family of Servers
Page 230
... Logs Using the chassis_code.codes File, 100 Interpreting Service Processor Error Chassis Logs, 98 Interpreting System Alerts, 96, 97 K Key FRU Identification Fields for Error Chassis Logs, 99 Key FRU Identification Fields for System Alerts, 97 L Power Distribution Safety Grounding, 255 Site Preparation Distribution Hardware Raceway Systems (electrical conduits), 254 LAN and Telephone, 247 LAN/SCSI LED States, 120 lighting requirements, 253 M Memory Configuration Rules, 28 Memory DIMM Removal, 171 Removing rp5400 Memory DIMMs, 171 Removing rp5470 Memory DIMMs, 171 Memory DIMM Replacement...
... Logs Using the chassis_code.codes File, 100 Interpreting Service Processor Error Chassis Logs, 98 Interpreting System Alerts, 96, 97 K Key FRU Identification Fields for Error Chassis Logs, 99 Key FRU Identification Fields for System Alerts, 97 L Power Distribution Safety Grounding, 255 Site Preparation Distribution Hardware Raceway Systems (electrical conduits), 254 LAN and Telephone, 247 LAN/SCSI LED States, 120 lighting requirements, 253 M Memory Configuration Rules, 28 Memory DIMM Removal, 171 Removing rp5400 Memory DIMMs, 171 Removing rp5470 Memory DIMMs, 171 Memory DIMM Replacement...
BCS Global Limited Warranty and Technical Support, Fourth Edition
Page 14
... expand your HP Hardware Product. 14 BCS Global Limited Warranty and Technical Support HP Care Pack Services may not apply to the Freeware operating system or other Freeware application support statement included with parts replacement when diagnostic tests confirm part failure. see "Customer responsibilities" (page 8) and "Customer self repair " (page 9). 4 For more details - Support for replacement. Software limited warranty EXCEPT AS PROVIDED IN THE APPLICABLE SOFTWARE END-USER LICENSE OR...
... expand your HP Hardware Product. 14 BCS Global Limited Warranty and Technical Support HP Care Pack Services may not apply to the Freeware operating system or other Freeware application support statement included with parts replacement when diagnostic tests confirm part failure. see "Customer responsibilities" (page 8) and "Customer self repair " (page 9). 4 For more details - Support for replacement. Software limited warranty EXCEPT AS PROVIDED IN THE APPLICABLE SOFTWARE END-USER LICENSE OR...