HP rp2450 Support and Manuals

Get Help and Manuals for this Hewlett-Packard item

View All Support Options Below
Free HP rp2450 manuals!
Problems with HP rp2450?

Ask a Question

Popular HP rp2450 Manual Pages

HP DLPI Programmer's Guide - Page 11

... are made at http://docs.hp.com. Table 1 shows the releases available for details. The document part number will change when extensive changes are expected to correct errors or document product changes. To ensure that you receive the updated or new editions, you should subscribe to the appropriate product support service. The printing date will change...
HP DLPI Programmer's Guide - Page 131

... message consists of service parameters contained invalid values. DL_CONNECT_IND Conveys to the local DLS user that a remote (calling) DLS user wishes to ) errors listed in state DL_DATAXFER... DLSAP address was not supported by the callee, DL_CONNECT_CON is indicated in an incorrect format or contained invalid information. The UNIX error returned may be set to (not limited to...
HP DLPI Programmer's Guide - Page 135

.... The UNIX error returned may only be set to (not limited to) errors listed in...error has occurred and the UNIX system error is DL_DATAXFER. Chapter 2 DLPI Primitives Connection-mode Service Primitives DL_INCON_PENDING. For the responding stream (designated by the DLS provider. DL_BADCORR The correlation number specified in a valid state for the responding stream was not supported...
HP DLPI Programmer's Guide - Page 11

... latest version of the OSI Reference Model terminology, OSI Data Link Services, and STREAMS. HP-UX Release Name and Release Identifier Each HP-UX 11i release has an associated release name and release identifier. Document updates may be issued between editions to correct errors or document product changes. Intended Audience This manual is printed. About This Document...
HP DLPI Programmer's Guide - Page 20

... defines the protocol through which layer the services are used throughout this guide. Introduction to identify different components of that architecture. The description of the data link layer is responsible for the transmission and error-free delivery of bits of information over a physical communications medium. A model of the model assumes familiarity with the OSI Reference...
HP DLPI Programmer's Guide - Page 132

The UNIX error returned may be set to (not limited to the connect request. If the request is erroneous, DL_ERROR_ACK is returned and the resulting state is indicated in the DL_ERROR_ACK. DL_BADQOSTYPE The quality of service structure type was in an incorrect format or contained invalid information. Format The message consists of service parameters contained invalid...
HP DLPI Programmer's Guide - Page 136

...was received, and the resulting state of service structure type was not supported by the parameter dl_res_token), the resulting state...service parameters contained invalid values. DL_BADCORR The correlation number specified in Table 2-2 on the stream where the DL_CONNECT_RES primitive was not in the DL_ERROR_ACK. The UNIX error returned may only be set to (not limited to) errors...
rp24xx A180 User Manual - Page 66

... is valid, the problem is usually in this point will appear as dictated by replacing the A-Class Exchange Base Unit (EBU). Failures that follow. To troubleshoot selftest failures by chassis code analysis, refer to the Replacing an A-Class Server Exchange Base Unit (EBU) section. A-Class System Service A-Class Server Trouble Shooting A-Class Server Selftest Failures/Warnings A power...
rp24xx A180 User Manual - Page 67

... components inside or out of LAN LED Heartbeat Blink pattern Memory HPMC fault (When LAN is ON, Heartbeat is OFF) 2nd Level Cache HPMC fault Second Level Cache/RAM Memory Module Faults Second Level Cache Memory Module Fault. NOTE NOTE Chapter 3 A-Class System Service A-Class Server Trouble Shooting The LED pattern is only valid if the Firmware Main Menu is an acronym...
rp24xx A180 User Manual - Page 69

... Discharge Precautions. Slide the top back, lift it off, and set it aside. List which pair of the server. Step 3. If fault does not recur, the SIMMs installed in and power up the server, and observe the front panel LEDs. Either replace both sides of error. To troubleshoot RAM faults to a single SIMM. Chapter 3 69 Step 4. Always observe all RAM...
rp24xx A180 User Manual - Page 70

... rear of error. Remove all electrostatic precautions when working with the system board. Power up the server and observe the front panel LEDs. The procedures in which of the server. A-Class System Service A-Class Server Trouble Shooting Step 2. If the fault does not recur, the problem was removed, that I /O boards. Slide the top back, lift it off, and set it...
rp24xx A180 User Manual - Page 71

... firmware main menu screen. Check the timestamp on the server and observe both the front panel LEDs and the console. A-Class System Service A-Class Server Trouble Shooting Step 5. Chassis codes provided by the HSC Remote Management card are useful in troubleshooting this type of error, because HPMCs generate many chassis codes and some chassis codes indicate a specific fault. Chassis...
rp24xx A180 User Manual - Page 72

.... Firmware Warning Messages Firmware is the name given to the system boot instructions and selftest software that are useful in response to boot the OS. This condition requires replacing the EBU. A Bus Converter failure requires replacing the EBU. 72 Chapter 3 A-Class System Service A-Class Server Trouble Shooting Second Level Cache Memory HPMC Fault. Check the timestamp on the console...
rp24xx A180 User Manual - Page 79

... server's front panel LEDs do not have an individual fault LED to indicate an embedded disk selftest failure. Connect an ASCII console to the RS232 port on the console. If the ASCII console works, but everyone on the rear of two internally installed and connected disk drives, commonly referred to the console (read access. Everyone else is the problem in a code...
rp24xx A180 User Manual - Page 80

... TERMINATION ENABLED jumper is applied to troubleshoot embedded disk faults. Password-protected disk expert tools are unfamiliar with part number A5182-69101 or later. 80 Chapter 3 Use a mapping tool to a hub, the 10 Base-T LAN on the console. The server will not connect to either the A-Class Server Disk Drive Removal and Replacement section, or look at the firmware Main Menu...

HP rp2450 Reviews

Do you have an experience with the HP rp2450 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP rp2450 Search Terms

The following terms are frequently used to search for HP rp2450 support:

Ask a New Question
Use the box below to post a new question about HP rp2450.
Manuals / Documents
Download any of our HP rp2450 manuals for free!

We have the following 7 documents available for the HP rp2450:
  • HP DLPI Programmer's Guide
  • HP DLPI Programmer's Guide
  • HP DTC Cabling and Racking Guide
  • ACSE/Presentation and ROSE Interface Programmer's Guide
  • DTC Device File Access Utilities and Telnet Port Identification
  • rp24xx A180 User Manual
  • CIFS/9000 Client Release Note, June 2002

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP rp2450 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP rp2450 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.