Brocade Access Gateway Administrator's Guide v6.2.0 (53-1001189-01, April 2009)
Page 19
... stable fabric. This document describes configurations using Access Gateway (AG). Please see the Web Tools Administrator's Guide, the Fabric Manager Administrator's Guide, or the Data Center Fabric Manager User Guide for more information about AG support in Native mode. They connect as E_Ports. Access Gateway Administrator... seamless connectivity to any Storage Area Network (SAN) fabric using the CLI commands. After you configure your Enterprise fabric to a single fabric. Enabling and disabling AG mode on how to set a Fabric OS switch to AG mode, the F_Ports connect to...
... stable fabric. This document describes configurations using Access Gateway (AG). Please see the Web Tools Administrator's Guide, the Fabric Manager Administrator's Guide, or the Data Center Fabric Manager User Guide for more information about AG support in Native mode. They connect as E_Ports. Access Gateway Administrator... seamless connectivity to any Storage Area Network (SAN) fabric using the CLI commands. After you configure your Enterprise fabric to a single fabric. Enabling and disabling AG mode on how to set a Fabric OS switch to AG mode, the F_Ports connect to...
HP StorageWorks Fabric OS 6.1.0f release notes (5697-7837, November 2008)
Page 13
...FCR) scalability For the latest scalability support information, see the HP StorageWorks SAN Design reference guide: http://www.hp.com/go/sandesignguide Firmware upgrade instructions IMPORTANT: HP recommends that users upgrade to the appropriate hardware reference guide for power specifications. To access the latest Fabric ... for Director blades Table 4 lists power supply requirements for the appropriate switch, select your product, and then select Cross operating system (BIOS, firmware, Diagnostics, etc.). 3. HP StorageWorks Fabric OS 6.1.0f release notes 13
...FCR) scalability For the latest scalability support information, see the HP StorageWorks SAN Design reference guide: http://www.hp.com/go/sandesignguide Firmware upgrade instructions IMPORTANT: HP recommends that users upgrade to the appropriate hardware reference guide for power specifications. To access the latest Fabric ... for Director blades Table 4 lists power supply requirements for the appropriate switch, select your product, and then select Cross operating system (BIOS, firmware, Diagnostics, etc.). 3. HP StorageWorks Fabric OS 6.1.0f release notes 13
HP StorageWorks Fabric OS 6.1.0g release notes (5697-7861, November 2008)
Page 13
...) scalability For the latest scalability support information, see the HP StorageWorks SAN Design reference guide: http://www.hp.com/go/sandesignguide Firmware upgrade instructions IMPORTANT: HP recommends that users upgrade to operate in the 4/256 SAN Director with nominal power of 6.1.x. See the appropriate hardware reference guide for the appropriate switch, select your product, and then select Cross operating system...
...) scalability For the latest scalability support information, see the HP StorageWorks SAN Design reference guide: http://www.hp.com/go/sandesignguide Firmware upgrade instructions IMPORTANT: HP recommends that users upgrade to operate in the 4/256 SAN Director with nominal power of 6.1.x. See the appropriate hardware reference guide for the appropriate switch, select your product, and then select Cross operating system...
HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009)
Page 19
...-48 Blade Brocade 300 Brocade 5100 Brocade 5300 Brocade 5410 Brocade 5480 HP StorageWorks SAN Director 6 Port 10Gb FC blade HP StorageWorks SAN Director16 Port 8Gb FC blade HP StorageWorks SAN Director 32 Port 8Gb FC blade HP StorageWorks SAN Director 48 Port 8Gb FC blade HP StorageWorks 8/8 SAN Switch or HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch HP StorageWorksEVA4400 Embedded Switch Module, 8Gb Brocade 8Gb SAN Switch for HP BladeSystem c-Class Fabric OS 6.1.x administrator guide 19
...-48 Blade Brocade 300 Brocade 5100 Brocade 5300 Brocade 5410 Brocade 5480 HP StorageWorks SAN Director 6 Port 10Gb FC blade HP StorageWorks SAN Director16 Port 8Gb FC blade HP StorageWorks SAN Director 32 Port 8Gb FC blade HP StorageWorks SAN Director 48 Port 8Gb FC blade HP StorageWorks 8/8 SAN Switch or HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch HP StorageWorksEVA4400 Embedded Switch Module, 8Gb Brocade 8Gb SAN Switch for HP BladeSystem c-Class Fabric OS 6.1.x administrator guide 19
HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009)
Page 329
...SAN Switch, 4/16 SAN Switch Yes Yes Yes No 8/8 SAN Switch, 8/24 SAN Switch, Yes Yes No Yes 8/80 SAN Switch SAN Switch 4/32, 4/64 SAN Yes Yes Yes Yes Switch, SAN Switch 4/32B, 400 Multi-protocol Router, and the 4/256 SAN Director DC SAN Backbone Director (short Yes Yes No Yes name, DC Director) and 8/40 SAN Switch CRC reports are accessed using the Web Tools GUI. Fabric OS 6.1.x administrator guide...AL_PA. • Top Talker monitoring -Measures the flows that are available only to users with specific values in the first 64 bytes of monitors supported on VE_Ports (virtual ...
...SAN Switch, 4/16 SAN Switch Yes Yes Yes No 8/8 SAN Switch, 8/24 SAN Switch, Yes Yes No Yes 8/80 SAN Switch SAN Switch 4/32, 4/64 SAN Yes Yes Yes Yes Switch, SAN Switch 4/32B, 400 Multi-protocol Router, and the 4/256 SAN Director DC SAN Backbone Director (short Yes Yes No Yes name, DC Director) and 8/40 SAN Switch CRC reports are accessed using the Web Tools GUI. Fabric OS 6.1.x administrator guide...AL_PA. • Top Talker monitoring -Measures the flows that are available only to users with specific values in the first 64 bytes of monitors supported on VE_Ports (virtual ...
HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009)
Page 335
For the SAN Switch 4/32, 4/64 SAN Switch, SAN Switch 4/32B, 400 Multi-protocol Router, and DC Director models, the maximum number of filters is 8 per port, in any combination of standard filters and user-defined filters. You can be configured on a port depends on the ...guide 335 The actual number of filters that have a maximum of 6 filter monitors per port, and 11 offsets per port for used defined monitors. • The middle 16 port (ports 16 through 31) have been transmitted by configuring a filter for the FC4-48 port blade. For the 4/8 SAN Switch and 4/16 SAN Switch...
For the SAN Switch 4/32, 4/64 SAN Switch, SAN Switch 4/32B, 400 Multi-protocol Router, and DC Director models, the maximum number of filters is 8 per port, in any combination of standard filters and user-defined filters. You can be configured on a port depends on the ...guide 335 The actual number of filters that have a maximum of 6 filter monitors per port, and 11 offsets per port for used defined monitors. • The middle 16 port (ports 16 through 31) have been transmitted by configuring a filter for the FC4-48 port blade. For the 4/8 SAN Switch and 4/16 SAN Switch...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 9
...Supported platforms for Virtual Fabrics 181 Supported port configurations in the HP StorageWorks 8/40 SAN Switch and HP StorageWorks 8/80 SAN Switch 181 Supported port configurations in the HP StorageWorks DC SAN Backbone Director and HP StorageWorks DC04 SAN Director 182 Virtual Fabrics interaction with other Fabric OS features 182... a user to an Admin Domain 201 Creating a new user account for managing Admin Domains 202 Assigning Admin Domains to an existing user account 202 Creating a new physical fabric administrator user account 202 Removing an Admin Domain from a user account ...
...Supported platforms for Virtual Fabrics 181 Supported port configurations in the HP StorageWorks 8/40 SAN Switch and HP StorageWorks 8/80 SAN Switch 181 Supported port configurations in the HP StorageWorks DC SAN Backbone Director and HP StorageWorks DC04 SAN Director 182 Virtual Fabrics interaction with other Fabric OS features 182... a user to an Admin Domain 201 Creating a new user account for managing Admin Domains 202 Assigning Admin Domains to an existing user account 202 Creating a new physical fabric administrator user account 202 Removing an Admin Domain from a user account ...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 25
... FC8-32 Blade FC8-48 Blade Brocade 300 HP StorageWorks DC SAN Backbone Director (short name, DC Director) HP StorageWorks DC04 SAN Director Switch HP StorageWorks SAN Director 6 Port 10Gb FC blade HP StorageWorks SAN Director16 Port 8Gb FC blade HP StorageWorks SAN Director 32 Port 8Gb FC blade HP StorageWorks SAN Director 48 Port 8Gb FC blade HP StorageWorks 8/8 SAN Switch or HP StorageWorks 8/24 SAN Switch Brocade 5100 Brocade 5300 HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch Fabric OS 6.2 administrator guide 25
... FC8-32 Blade FC8-48 Blade Brocade 300 HP StorageWorks DC SAN Backbone Director (short name, DC Director) HP StorageWorks DC04 SAN Director Switch HP StorageWorks SAN Director 6 Port 10Gb FC blade HP StorageWorks SAN Director16 Port 8Gb FC blade HP StorageWorks SAN Director 32 Port 8Gb FC blade HP StorageWorks SAN Director 48 Port 8Gb FC blade HP StorageWorks 8/8 SAN Switch or HP StorageWorks 8/24 SAN Switch Brocade 5100 Brocade 5300 HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch Fabric OS 6.2 administrator guide 25
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 49
... the Ports on Demand optional licensed product. Table 5 List of available ports when implementing PODs Platform Available user ports No POD license POD1 or POD2 present Both POD license present HP StorageWorks 4/8 SAN Switch HP StorageWorks 8/8 SAN Switch HP StorageWorks 4/32 SAN Switch HP StorageWorks 4/64 SAN Switch HP StorageWorks 4/32B SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 0-7 0-7 0-15 0-31 0-15 0-23 0-47 0-11 0-15 0-23 0-47 0-23 0-31 0-63 0-15 0-23 0-31 0-63...
... the Ports on Demand optional licensed product. Table 5 List of available ports when implementing PODs Platform Available user ports No POD license POD1 or POD2 present Both POD license present HP StorageWorks 4/8 SAN Switch HP StorageWorks 8/8 SAN Switch HP StorageWorks 4/32 SAN Switch HP StorageWorks 4/64 SAN Switch HP StorageWorks 4/32B SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 0-7 0-7 0-15 0-31 0-15 0-23 0-47 0-11 0-15 0-23 0-47 0-23 0-31 0-63 0-15 0-23 0-31 0-63...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 183
... you are logged in to a Logical Switch, the system prompt changes to user accounts. Supported port configurations in the HP StorageWorks 8/40 SAN Switch and HP StorageWorks 8/80 SAN Switch There are no restrictions on the port type and blade type. The following platforms: • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 8/80 SAN Switch • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director Some restrictions apply to logical...
... you are logged in to a Logical Switch, the system prompt changes to user accounts. Supported port configurations in the HP StorageWorks 8/40 SAN Switch and HP StorageWorks 8/80 SAN Switch There are no restrictions on the port type and blade type. The following platforms: • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 8/80 SAN Switch • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director Some restrictions apply to logical...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 409
... • HP StorageWorks 4/8 SAN Switch • HP StorageWorks 4/16 SAN Switche • HP StorageWorks 8/8 SAN Switch • HP StorageWorks 8/24 SAN Switche • HP StorageWorks 8/80 SAN Switch Yes Yes No No Yes Yes No Yes • HP StorageWorks SAN Switch 4/32 • HP StorageWorks 4/64 SAN Switch • HP StorageWorks SAN Switch 4/32B • HP StorageWorks 400 Multi-Protocol Router • HP StorageWorks 4/256 SAN Director • HP StorageWorks 8/40 SAN Switch • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director Switch Yes Yes...
... • HP StorageWorks 4/8 SAN Switch • HP StorageWorks 4/16 SAN Switche • HP StorageWorks 8/8 SAN Switch • HP StorageWorks 8/24 SAN Switche • HP StorageWorks 8/80 SAN Switch Yes Yes No No Yes Yes No Yes • HP StorageWorks SAN Switch 4/32 • HP StorageWorks 4/64 SAN Switch • HP StorageWorks SAN Switch 4/32B • HP StorageWorks 400 Multi-Protocol Router • HP StorageWorks 4/256 SAN Director • HP StorageWorks 8/40 SAN Switch • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director Switch Yes Yes...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 415
...user-defined monitors. • The upper 16 ports (ports 32 through 31) have the same values for complete descriptions of these commands. Connect to be configured on a port depends on the complexity of the filters. Fabric OS 6.2 administrator guide... are supported on ISLs and extended ISLs (XISLs). • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 400 Multi-Protocol Router • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director Switch For the HP StorageWorks 4/256 SAN Directors, the maximum number of filters is configured on the trunk...
...user-defined monitors. • The upper 16 ports (ports 32 through 31) have the same values for complete descriptions of these commands. Connect to be configured on a port depends on the complexity of the filters. Fabric OS 6.2 administrator guide... are supported on ISLs and extended ISLs (XISLs). • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 400 Multi-Protocol Router • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director Switch For the HP StorageWorks 4/256 SAN Directors, the maximum number of filters is configured on the trunk...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 429
...port. • The following switches do not have this limitation: • HP StorageWorks 8/8 and 8/24 SAN Switches • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 8/80 SAN Switch • HP StorageWorks SAN Director 16 Port 8Gb FC blade • HP StorageWorks SAN Director 32 Port 8Gb FC blade • HP StorageWorks SAN Director 48 Port 8Gb FC... 6.x capable switch modules. Following are the considerations for the calculation: • Each port is part of a port group that includes a pool of user ports in Table 83 on page 428. Fabric OS 6.2 administrator guide 425 This ...
...port. • The following switches do not have this limitation: • HP StorageWorks 8/8 and 8/24 SAN Switches • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 8/80 SAN Switch • HP StorageWorks SAN Director 16 Port 8Gb FC blade • HP StorageWorks SAN Director 32 Port 8Gb FC blade • HP StorageWorks SAN Director 48 Port 8Gb FC... 6.x capable switch modules. Following are the considerations for the calculation: • Each port is part of a port group that includes a pool of user ports in Table 83 on page 428. Fabric OS 6.2 administrator guide 425 This ...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 431
... ports (per switch/blade) User port group size Unreserved buffers (per port group) HP StorageWorks 4/8 and 16 16 4/16 SAN Switches HP StorageWorks 8/8 and 24 24 8/24 SAN Switches HP StorageWorks SAN 32 32 Switch 4/32, HP StorageWorks SAN Switch 4/32B HP StorageWorks 4/64 64 16 SAN Switch HP StorageWorks 8/40 40 40 SAN Switch 144 484 744 584 1692 HP StorageWorks 8/80 80 16 292 SAN Switch HP StorageWorks 400 16 8 377 Multi-Protocol Router FA4-18 16 8 404 Fabric OS 6.2 administrator guide 427 Max...
... ports (per switch/blade) User port group size Unreserved buffers (per port group) HP StorageWorks 4/8 and 16 16 4/16 SAN Switches HP StorageWorks 8/8 and 24 24 8/24 SAN Switches HP StorageWorks SAN 32 32 Switch 4/32, HP StorageWorks SAN Switch 4/32B HP StorageWorks 4/64 64 16 SAN Switch HP StorageWorks 8/40 40 40 SAN Switch 144 484 744 584 1692 HP StorageWorks 8/80 80 16 292 SAN Switch HP StorageWorks 400 16 8 377 Multi-Protocol Router FA4-18 16 8 404 Fabric OS 6.2 administrator guide 427 Max...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 439
... HP StorageWorks SAN Switch 4/32, HP StorageWorks 4/64 SAN Switch, HP StorageWorks 400 Multi-Protocol Router, HP StorageWorks 8/40 SAN Switch, HP StorageWorks 8/80 SAN Switch, HP StorageWorks 8/8 and 8/24 SAN Switches, Brocade 4Gb SAN Switch for HP c-Class BladeSystem, the HP StorageWorks 4/256 SAN Director using the HP StorageWorks 4/256 SAN Director 16 Port 4Gb Blade, HP StorageWorks 4/256 SAN Director 32 Port 4Gb Blade, HP StorageWorks SAN Director 48 Port 4Gb FC blade, HP StorageWorks B-Series iSCSI Director Blade, HP StorageWorks SAN Director 16 Port 8Gb FC blade, HP StorageWorks SAN...
... HP StorageWorks SAN Switch 4/32, HP StorageWorks 4/64 SAN Switch, HP StorageWorks 400 Multi-Protocol Router, HP StorageWorks 8/40 SAN Switch, HP StorageWorks 8/80 SAN Switch, HP StorageWorks 8/8 and 8/24 SAN Switches, Brocade 4Gb SAN Switch for HP c-Class BladeSystem, the HP StorageWorks 4/256 SAN Director using the HP StorageWorks 4/256 SAN Director 16 Port 4Gb Blade, HP StorageWorks 4/256 SAN Director 32 Port 4Gb Blade, HP StorageWorks SAN Director 48 Port 4Gb FC blade, HP StorageWorks B-Series iSCSI Director Blade, HP StorageWorks SAN Director 16 Port 8Gb FC blade, HP StorageWorks SAN...
HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)
Page 453
... within the trunk. 5. Configure the trunk on all ports to the switch and log in the TA. 3. For more information on the HP StorageWorks SAN Director 48 Port 4Gb FC blade. Fabric OS 6.2 administrator guide 449 Connect to the switch and log in AG mode) have trunking enabled by assigning the Trunk ... for ports 13 and 14 on slot 10 with a port index of ports on the user port number, with a port index of a switch. Ensure edge switch F_Port trunk ports are based on the switch (see the Fabric OS Command Reference. Ensure ports will not support shared area ports 16-...
... within the trunk. 5. Configure the trunk on all ports to the switch and log in the TA. 3. For more information on the HP StorageWorks SAN Director 48 Port 4Gb FC blade. Fabric OS 6.2 administrator guide 449 Connect to the switch and log in AG mode) have trunking enabled by assigning the Trunk ... for ports 13 and 14 on slot 10 with a port index of ports on the user port number, with a port index of a switch. Ensure edge switch F_Port trunk ports are based on the switch (see the Fabric OS Command Reference. Ensure ports will not support shared area ports 16-...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 19
...; A USB port that facilitates firmware upgrades, serviceability, and system-log functionality • A switch subsystem and encryption subsystem that provide high performance with integ- The front-end user ports in the fabric • SFP or SFP+ optical transceivers, providing support for a combination... an additional 48 Gb/s bandwidth. Port side of the Encryption SAN Switch The port side of the Encryption SAN Switch. 8-Gb SAN Switch Hardware Reference Guide 19 Figure 6 shows the port side of the Encryption SAN Switch includes the status and power LEDs, smart card reader, the ...
...; A USB port that facilitates firmware upgrades, serviceability, and system-log functionality • A switch subsystem and encryption subsystem that provide high performance with integ- The front-end user ports in the fabric • SFP or SFP+ optical transceivers, providing support for a combination... an additional 48 Gb/s bandwidth. Port side of the Encryption SAN Switch The port side of the Encryption SAN Switch. 8-Gb SAN Switch Hardware Reference Guide 19 Figure 6 shows the port side of the Encryption SAN Switch includes the status and power LEDs, smart card reader, the ...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 32
...; A minimum of 79.8 cubic meters/hour (47 cubic feet/minute) of the switch, ensure that the following items: • HP StorageWorks product documentation: • HP StorageWorks 8-Gb SAN Switch Quick Start Instructions • HP StorageWorks SAN Switch Rack Mount Kit Installation Instructions • Read Me First • Safety Guides • User License • Warranty • A serial cable, approximately 3 m (10 ft.) • Plenum (not...
...; A minimum of 79.8 cubic meters/hour (47 cubic feet/minute) of the switch, ensure that the following items: • HP StorageWorks product documentation: • HP StorageWorks 8-Gb SAN Switch Quick Start Instructions • HP StorageWorks SAN Switch Rack Mount Kit Installation Instructions • Read Me First • Safety Guides • User License • Warranty • A serial cable, approximately 3 m (10 ft.) • Plenum (not...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 53
... HP Secure Key Manager User Guide. They include diagnostic tests and field-replaceable units for high availability and low failure. For additional SKM setup requirements, see the Fabric OS Encryption Administrator's Guide. 3 Managing the 8-Gb SAN Switches The 8-Gb SAN Switches are designed for the HP StorageWorks 8/40 and 8/80 SAN Switches, the Encryption SAN Switch the FCoE Converged Network Switch, and the 1606 Extension SAN Switch...
... HP Secure Key Manager User Guide. They include diagnostic tests and field-replaceable units for high availability and low failure. For additional SKM setup requirements, see the Fabric OS Encryption Administrator's Guide. 3 Managing the 8-Gb SAN Switches The 8-Gb SAN Switches are designed for the HP StorageWorks 8/40 and 8/80 SAN Switches, the Encryption SAN Switch the FCoE Converged Network Switch, and the 1606 Extension SAN Switch...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 61
...5 seconds) Status of the fans in the fan assembly has failed. • The fan FRU was disabled by the user. NOTE: When the switch is first powered on and seated and the power cord is on the power supply status LED will show amber until POST... is operating nor- Power supply is enabled (use the fanenable command). • Replace the fan FRU. 8-Gb SAN Switch Hardware Reference Guide 61 Steady green Steady amber (for the 8/80 SAN Switch Table 9 describes LEDs and recommended actions. Nonport side LED activity for more than five seconds) Fan assembly is disconnected...
...5 seconds) Status of the fans in the fan assembly has failed. • The fan FRU was disabled by the user. NOTE: When the switch is first powered on and seated and the power cord is on the power supply status LED will show amber until POST... is operating nor- Power supply is enabled (use the fanenable command). • Replace the fan FRU. 8-Gb SAN Switch Hardware Reference Guide 61 Steady green Steady amber (for the 8/80 SAN Switch Table 9 describes LEDs and recommended actions. Nonport side LED activity for more than five seconds) Fan assembly is disconnected...