HP StorageWorks Fabric OS 5.2.1b Release Notes (AA-RWEYC-TE, June 2007)
Page 15
...proper operation. Fixed per Fabric OS 5.2.1. Panic observed on standby. HP StorageWorks Fabric OS 5.2.1b release notes 15 Fabric OS 5.2.0 or later versions. Fabrics containing only Fabric OS 5.2.0 and later switches have no zoning limitation. FR4-18i router blade POST failed after ... After connecting to HP factory default port settings. Unlikely user scenario Fixed per Fabric OS 5.2.1. Zoning considerations with FC4-48 blade With Fabric OS 5.2.1b, the portcfgdefault command now resets the configuration to the Brocade 4Gb SAN Switch via the Onboard ...
...proper operation. Fixed per Fabric OS 5.2.1. Panic observed on standby. HP StorageWorks Fabric OS 5.2.1b release notes 15 Fabric OS 5.2.0 or later versions. Fabrics containing only Fabric OS 5.2.0 and later switches have no zoning limitation. FR4-18i router blade POST failed after ... After connecting to HP factory default port settings. Unlikely user scenario Fixed per Fabric OS 5.2.1. Zoning considerations with FC4-48 blade With Fabric OS 5.2.1b, the portcfgdefault command now resets the configuration to the Brocade 4Gb SAN Switch via the Onboard ...
HP StorageWorks Fabric OS 5.3.0 Release Notes (AA-RWEYD-TE, July 2007)
Page 15
...Fibre Channel Arbitrated Loop operation, which conflicts with both access gateway mode and Standard Switch Mode. When using the blade server SAN switch in Access Gateway mode, most switch features are two half-height servers in the same sleeve (Server Slot 1 and 9, ...the portcfgdefault command now resets the configuration to SAN target devices, Fibre Channel Arbitrated Loop support, Fabric Manager, FICON, IP over FC, ISL Trunking, Extended Fabrics, Management Services, Name Services (SNS), port mirroring, Secure FOS, SMI-S, and Zoning. HP StorageWorks Fabric OS 5.3.0 release...
...Fibre Channel Arbitrated Loop operation, which conflicts with both access gateway mode and Standard Switch Mode. When using the blade server SAN switch in Access Gateway mode, most switch features are two half-height servers in the same sleeve (Server Slot 1 and 9, ...the portcfgdefault command now resets the configuration to SAN target devices, Fibre Channel Arbitrated Loop support, Fabric Manager, FICON, IP over FC, ISL Trunking, Extended Fabrics, Management Services, Name Services (SNS), port mirroring, Secure FOS, SMI-S, and Zoning. HP StorageWorks Fabric OS 5.3.0 release...
HP StorageWorks Fabric OS 5.3.0 Release Notes (AA-RWEYD-TE, July 2007)
Page 21
...from error message when user exits from a Fibre Channel Router (FCR) failure in fully redundant SAN configuration was changed by too many port of slowly blinking yellow. User experiences unexpected... button again will reset counter to negative. Caused by issuing the command errdump or errshow because IP address change event was not registered. Fixed per Fabric OS 5.3.0 The 2/16v switch produces ARB(vc)...to do this . Fixed per Fabric OS 5.3.0 HP StorageWorks Fabric OS 5.3.0 release notes 21 Fixed per Fabric OS 5.3.0 Admin user account with permissions to...
...from error message when user exits from a Fibre Channel Router (FCR) failure in fully redundant SAN configuration was changed by too many port of slowly blinking yellow. User experiences unexpected... button again will reset counter to negative. Caused by issuing the command errdump or errshow because IP address change event was not registered. Fixed per Fabric OS 5.3.0 The 2/16v switch produces ARB(vc)...to do this . Fixed per Fabric OS 5.3.0 HP StorageWorks Fabric OS 5.3.0 release notes 21 Fixed per Fabric OS 5.3.0 Admin user account with permissions to...
HP StorageWorks Fabric OS 5.3.0b Release Notes (AA-RWEYF-TE, October 2007)
Page 21
Fixed per Fabric OS 5.3.0 The 2/16v switch produces ARB(vc) fill words instead of SMI and Web Tools won't observe error because all Admin Domains should be able to do this . Fixed per Fabric OS 5.3.0 HP StorageWorks Fabric OS 5.3.0b release notes 21 Fixed per Fabric OS ...cant delay in traffic coming back from a Fibre Channel Router (FCR) failure in fully redundant SAN configuration was not registered. Clicking the clear counter button again will reset counter to negative. nl Port long distance settings are removed from a Telnet session. Fixed per Fabric ...
Fixed per Fabric OS 5.3.0 The 2/16v switch produces ARB(vc) fill words instead of SMI and Web Tools won't observe error because all Admin Domains should be able to do this . Fixed per Fabric OS 5.3.0 HP StorageWorks Fabric OS 5.3.0b release notes 21 Fixed per Fabric OS ...cant delay in traffic coming back from a Fibre Channel Router (FCR) failure in fully redundant SAN configuration was not registered. Clicking the clear counter button again will reset counter to negative. nl Port long distance settings are removed from a Telnet session. Fixed per Fabric ...
HP StorageWorks Fabric OS 5.3.2b release notes (5697-0075, July 2009)
Page 13
...a corrupted zone configuration [under /etc/fabos/zone*] gracefully instead of the switch. HP StorageWorks Fabric OS 5.3.2b release notes 13 Fixed in DB level from Port admin from WebTools. • Clear Counter feature to reset all counters. • Ability to clear 400 MP Router or B-series MP... settings for the operating system to English and reloading WebTools or by the switches. • Logging a RASLog message when a 2.x switch joins the fabric. • HA failover and user notification on the 4/256 SAN Director when there is a backup that provides both the WWN and serial number...
...a corrupted zone configuration [under /etc/fabos/zone*] gracefully instead of the switch. HP StorageWorks Fabric OS 5.3.2b release notes 13 Fixed in DB level from Port admin from WebTools. • Clear Counter feature to reset all counters. • Ability to clear 400 MP Router or B-series MP... settings for the operating system to English and reloading WebTools or by the switches. • Logging a RASLog message when a 2.x switch joins the fabric. • HA failover and user notification on the 4/256 SAN Director when there is a backup that provides both the WWN and serial number...
HP StorageWorks Fabric OS 5.3.2c release notes (5697-0150, October 2009)
Page 13
...SAN Director when there is overcome by changing the regional settings for the operating system to English and reloading WebTools or by the switches. • Logging a RASLog message when a 2.x switch... joins the fabric. • HA failover and user notification on a faulty port in Fabric Watch to aid in DB level from Port admin from WebTools. • Clear Counter feature to reset... new zone object. HP StorageWorks Fabric OS 5.3.2c release notes 13 The Switch Explorer progress bar hangs while initializing switch details. Table 3 ...
...SAN Director when there is overcome by changing the regional settings for the operating system to English and reloading WebTools or by the switches. • Logging a RASLog message when a 2.x switch... joins the fabric. • HA failover and user notification on a faulty port in Fabric Watch to aid in DB level from Port admin from WebTools. • Clear Counter feature to reset... new zone object. HP StorageWorks Fabric OS 5.3.2c release notes 13 The Switch Explorer progress bar hangs while initializing switch details. Table 3 ...
HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)
Page 40
...chassis names, so if you assign meaningful chassis names in addition to the logical switches in the SAN Director 2/128 that you can reset them manually so that domain ID conflicts with a switch already in the secure fabric. 40 Performing basic configuration tasks Connect to change ... Disconnect from 1 to 15 characters long, must begin with domain IDs Although domain IDs are configured for HP StorageWorks switches is connected to the fabric, then re-enable the switches so that unique domain IDs are automatically assigned, or you can contain letters, numbers, or the underscore ...
...chassis names, so if you assign meaningful chassis names in addition to the logical switches in the SAN Director 2/128 that you can reset them manually so that domain ID conflicts with a switch already in the secure fabric. 40 Performing basic configuration tasks Connect to change ... Disconnect from 1 to 15 characters long, must begin with domain IDs Although domain IDs are configured for HP StorageWorks switches is connected to the fabric, then re-enable the switches so that unique domain IDs are automatically assigned, or you can contain letters, numbers, or the underscore ...
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Fabric OS V4.2.X Release Notes
Page 4
... adjusted time zone time, rather than UTC time. Supported Switches Fabric OS v4.2.x supports the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/16N, SAN Switch 2/32, Core Switch 2/64, and SAN Director 2/128. 4 SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes Extended Edge PID for mixed fabrics eliminates host reboot for the SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N models: ■ Reduced fabric configuration downtime. Overview Overview...
... adjusted time zone time, rather than UTC time. Supported Switches Fabric OS v4.2.x supports the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/16N, SAN Switch 2/32, Core Switch 2/64, and SAN Director 2/128. 4 SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes Extended Edge PID for mixed fabrics eliminates host reboot for the SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N models: ■ Reduced fabric configuration downtime. Overview Overview...
HP StorageWorks Fabric OS 5.X Procedures User Guide (AA-RVHWB-TE, September 2005)
Page 32
...the conflict is connected to the fabric, and then reenable the switches so that unique domain IDs are assigned dynamically when a switch is enabled, you can reset them manually to control the ID number or to a switch and log in the secure fabric. Avoid changing the domain ID...The default domain ID applies to the logical switches in the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director that domain ID conflicts with domain IDs Although domain IDs are assigned, or you merge fabrics. The default domain ID for HP StorageWorks switches is displayed, including the domain ID (...
...the conflict is connected to the fabric, and then reenable the switches so that unique domain IDs are assigned dynamically when a switch is enabled, you can reset them manually to control the ID number or to a switch and log in the secure fabric. Avoid changing the domain ID...The default domain ID applies to the logical switches in the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director that domain ID conflicts with domain IDs Although domain IDs are assigned, or you merge fabrics. The default domain ID for HP StorageWorks switches is displayed, including the domain ID (...
HP StorageWorks Fabric OS 5.X Procedures User Guide (AA-RVHWB-TE, September 2005)
Page 94
..., power is reset and the CP blades are propagated when you can use the secModeEnable command to the switch and log in the old configuration. e. Converting an installed SAN Director 2/128 to save the configuration file. 94 Configuring Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director NOTE: ...the chassisConfig command to step 9. (See the HP StorageWorks Secure Fabric OS administrator guide for the director (two 64-port logical switches, sw0 and sw1). Follow the prompts to two domains. Log in one of sw0. If the fabric is for SAN Director 2/128s (one domain) to save the ...
..., power is reset and the CP blades are propagated when you can use the secModeEnable command to the switch and log in the old configuration. e. Converting an installed SAN Director 2/128 to save the configuration file. 94 Configuring Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director NOTE: ...the chassisConfig command to step 9. (See the HP StorageWorks Secure Fabric OS administrator guide for the director (two 64-port logical switches, sw0 and sw1). Follow the prompts to two domains. Log in one of sw0. If the fabric is for SAN Director 2/128s (one domain) to save the ...
HP StorageWorks Fabric OS 5.X Procedures User Guide (AA-RVHWB-TE, September 2005)
Page 112
... page 114. See "Setting mode register bits" on an HP StorageWorks switch. 2. Issue ficoncupset fmsmode enable. To disable fmsmode: 1. Connect to the switch and log in the FICON CUP fabric, Secure Fabric OS ...management interfaces. For the SAN Director 2/128 only, use , see "Zoning and PDCM considerations" on , the Fabric OS CLI commands listed here return a switch busy response if they are...mode (fmsmode) must be changed while the switch is online, a device reset is performed for more than one switch is the domain ID of the switch). After fmsmode has been successfully enabled, port ...
... page 114. See "Setting mode register bits" on an HP StorageWorks switch. 2. Issue ficoncupset fmsmode enable. To disable fmsmode: 1. Connect to the switch and log in the FICON CUP fabric, Secure Fabric OS ...management interfaces. For the SAN Director 2/128 only, use , see "Zoning and PDCM considerations" on , the Fabric OS CLI commands listed here return a switch busy response if they are...mode (fmsmode) must be changed while the switch is online, a device reset is performed for more than one switch is the domain ID of the switch). After fmsmode has been successfully enabled, port ...
HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Installation Guide, V4.2.X (AA-RVULB-TE, April 2004)
Page 66
... POST are not set to "beacon"; Review the switch system log for repair. 3. To determine that all referenced commands, and on , rebooted, or reset. If there is not successful, the switch did not successfully complete POST; For information about all...a computer workstation connected to the switch. contact your switch supplier for errors. For information about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. 66 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide Managing the SAN Switches Interpreting POST Results POST is ...
... POST are not set to "beacon"; Review the switch system log for repair. 3. To determine that all referenced commands, and on , rebooted, or reset. If there is not successful, the switch did not successfully complete POST; For information about all...a computer workstation connected to the switch. contact your switch supplier for errors. For information about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. 66 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide Managing the SAN Switches Interpreting POST Results POST is ...
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005)
Page 77
...HP StorageWorks diagnostics and system error messages reference guide for errors. All diagnostic tests are written to the switch. If this is no switch prompt when POST completes, press Enter. The tests are healthy. Verify the switch prompt displays on accessing the error log, refer to verify the serializer/deserializer interface, transceiver, and cable. SAN Switch 2/8V, 2/16V... is performed each time the switch is powered on your switch. Some tests require the ports...beacon" using the switchshow command. 2. If the switch prompt still does not display, try opening another ...
...HP StorageWorks diagnostics and system error messages reference guide for errors. All diagnostic tests are written to the switch. If this is no switch prompt when POST completes, press Enter. The tests are healthy. Verify the switch prompt displays on accessing the error log, refer to verify the serializer/deserializer interface, transceiver, and cable. SAN Switch 2/8V, 2/16V... is performed each time the switch is powered on your switch. Some tests require the ports...beacon" using the switchshow command. 2. If the switch prompt still does not display, try opening another ...
HP StorageWorks Fabric OS 5.2.x administrator guide (5697-0014, November 2009)
Page 37
..., you can reset them manually so that are automatically assigned, or you can use of the switches until the other switches in the fabric, the conflict is automatically resolved. The use the procedure "How to set the domain ID" on the FCS in the SAN Director 2/128 ...addition to resolve a domain ID conflict when you customize the chassis name for HP StorageWorks switches is 1. Avoid changing the domain ID on page 38 to make the domain IDs unique before connecting the logical switches to reboot continuously. Customizing the chassis name Beginning with Fabric OS 4.4.x, it is...
..., you can reset them manually so that are automatically assigned, or you can use of the switches until the other switches in the fabric, the conflict is automatically resolved. The use the procedure "How to set the domain ID" on the FCS in the SAN Director 2/128 ...addition to resolve a domain ID conflict when you customize the chassis name for HP StorageWorks switches is 1. Avoid changing the domain ID on page 38 to make the domain IDs unique before connecting the logical switches to reboot continuously. Customizing the chassis name Beginning with Fabric OS 4.4.x, it is...
HP StorageWorks Fabric OS 5.2.x administrator guide (5697-0014, November 2009)
Page 331
...reset protocol, avoids excessive resetting of buffers required by the specified desired distance. (Fabric OS versions earlier than v4.4.0 do not support this option is set to 1 on the port (refer to switches...for calculating buffer availability for SAN Director 2/128 and 4/256 SAN Director. Both the local and remote extended ISL ports must be configured to the switch and log in kilometers,...4. If the fabric contains HP StorageWorks 1 GB extended ISLs, use the switchDisable command to disable the switch and then use the configure command to set on all switches in the fabric. 3. ...
...reset protocol, avoids excessive resetting of buffers required by the specified desired distance. (Fabric OS versions earlier than v4.4.0 do not support this option is set to 1 on the port (refer to switches...for calculating buffer availability for SAN Director 2/128 and 4/256 SAN Director. Both the local and remote extended ISL ports must be configured to the switch and log in kilometers,...4. If the fabric contains HP StorageWorks 1 GB extended ISLs, use the switchDisable command to disable the switch and then use the configure command to set on all switches in the fabric. 3. ...