Booting HP ProLiant servers from a storage area network
Page 7
... constituting an additional warranty. The only warranties for Optimal Performance and Functionality of HP ProLiant Servers http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00403562/c00403562.pdf http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00264524/c00264524.pdf Call to action Send comments... about this paper to: TechCom@HP.com. © 2005, 2007 Hewlett-Packard Development Company, L.P. TC070303HT, 3/2007 Nothing herein should be liable for technical or editorial errors or omissions...
... constituting an additional warranty. The only warranties for Optimal Performance and Functionality of HP ProLiant Servers http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00403562/c00403562.pdf http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00264524/c00264524.pdf Call to action Send comments... about this paper to: TechCom@HP.com. © 2005, 2007 Hewlett-Packard Development Company, L.P. TC070303HT, 3/2007 Nothing herein should be liable for technical or editorial errors or omissions...
HP VMware ESXi management environment
Page 20
...HP Insight Management WBEM Providers (Insight Providers) are based on the SMASH and SMI-S standards, and further extend them to support information that is specific to ProLiant platforms. Web-based Enterprise Management WBEM is a set of WBEM standards includes a data model (CIM) and a management protocol. VMware ESXi for ProLiant...XML, is in widespread use on a consistent solution has emerged. SNMP is the foundation for the SMI-S. 2 DMTF WBEM Definition, 2005, www.dmtf.org/standards/wbem 20 It is a lightweight, mature, and non-proprietary standard. Administrators need to be a labor-...
...HP Insight Management WBEM Providers (Insight Providers) are based on the SMASH and SMI-S standards, and further extend them to support information that is specific to ProLiant platforms. Web-based Enterprise Management WBEM is a set of WBEM standards includes a data model (CIM) and a management protocol. VMware ESXi for ProLiant...XML, is in widespread use on a consistent solution has emerged. SNMP is the foundation for the SMI-S. 2 DMTF WBEM Definition, 2005, www.dmtf.org/standards/wbem 20 It is a lightweight, mature, and non-proprietary standard. Administrators need to be a labor-...
ISS Technology Update, Volume 9 Number 1
Page 2
... rates (10 Gigabit Ethernet, 6 Gb/s SAS). The variation stems from the International System of Units (SI), and they are in the international standard IEC 60027-2:2005, third 2 Factor 103 106 109 1012 1015 1018 1021 1024 Correct SI usage Value 1,000 1,000,000 1,000,000,000 1,000,000,000,000 1,000...
... rates (10 Gigabit Ethernet, 6 Gb/s SAS). The variation stems from the International System of Units (SI), and they are in the international standard IEC 60027-2:2005, third 2 Factor 103 106 109 1012 1015 1018 1021 1024 Correct SI usage Value 1,000 1,000,000 1,000,000,000 1,000,000,000,000 1,000...
Memory technology evolution: an overview of system memory technologies, 8th Edition
Page 20
... should be liable for HP products and services are set forth in HP ProLiant servers Web address http://www.jedec.org http://h18004.www1.hp.com/products/servers/technology/whitepapers/advtechnology.html#mem http://h18004.www1.hp.com/products/servers/technology/whitepapers.../advtechnology.html#mem Call to action Send comments about this paper to TechCom@HP.com. © 2003, 2004, 2005...
... should be liable for HP products and services are set forth in HP ProLiant servers Web address http://www.jedec.org http://h18004.www1.hp.com/products/servers/technology/whitepapers/advtechnology.html#mem http://h18004.www1.hp.com/products/servers/technology/whitepapers.../advtechnology.html#mem Call to action Send comments about this paper to TechCom@HP.com. © 2003, 2004, 2005...
Optimizing facility operation in high density data center environments
Page 4
... Equipment Power Trends and Cooling Applications, Chapter 3, Fig 3.10 New ASHRAE updated and expanded power trend chart, © 2005 American Society of power requirements for designing a storage infrastructure. It is based on square footage of the equipment footprint. These... tools can provide power and computational workload estimates for both small-to more accurately estimate the power needs of HP ProLiant systems. The calculator provides meaningful estimates of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Figure 1. Figure is available as...
... Equipment Power Trends and Cooling Applications, Chapter 3, Fig 3.10 New ASHRAE updated and expanded power trend chart, © 2005 American Society of power requirements for designing a storage infrastructure. It is based on square footage of the equipment footprint. These... tools can provide power and computational workload estimates for both small-to more accurately estimate the power needs of HP ProLiant systems. The calculator provides meaningful estimates of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Figure 1. Figure is available as...
Optimizing facility operation in high density data center environments
Page 13
The percentage of the Future US Server Power Spend for 2005 as 70 percent.6 Power management and reporting Management tools that is supported for facility metrics and management. Insight Power Manager also supports changing the Power .../go/ipm. Most data centers use a downdraft airflow pattern in which reduces the heat output into hot aisles (Figure 7). Insight Power Manager is a ProLiant Essentials product that is HP's Insight Power Manager (IPM). applied a cooling factor of power and thermal data. applied a .6 multiplier to limit the amount of power consumed, which air...
The percentage of the Future US Server Power Spend for 2005 as 70 percent.6 Power management and reporting Management tools that is supported for facility metrics and management. Insight Power Manager also supports changing the Power .../go/ipm. Most data centers use a downdraft airflow pattern in which reduces the heat output into hot aisles (Figure 7). Insight Power Manager is a ProLiant Essentials product that is HP's Insight Power Manager (IPM). applied a cooling factor of power and thermal data. applied a .6 multiplier to limit the amount of power consumed, which air...
Power basics for IT professionals
Page 25
... data centers are based on actual system measurements, taken on rational factors to 30 percent per U and 25 to 18 kilowatts of 2005, it appears that power, cooling, and redundancy be higher than 1 kilowatt per server generation. As of power. Power Calculator results ...change to plan for N+1 redundancy, N (that amount, or 10 to 30 kilowatts per rack. HP Power Calculators are being exercised at the following http://h30099.www3.hp.com/configurator/powercalcs.asp and www.hp.com/go/bladesystem/powercalculator. To anticipate maximum real-world power loads and capacities...
... data centers are based on actual system measurements, taken on rational factors to 30 percent per U and 25 to 18 kilowatts of 2005, it appears that power, cooling, and redundancy be higher than 1 kilowatt per server generation. As of power. Power Calculator results ...change to plan for N+1 redundancy, N (that amount, or 10 to 30 kilowatts per rack. HP Power Calculators are being exercised at the following http://h30099.www3.hp.com/configurator/powercalcs.asp and www.hp.com/go/bladesystem/powercalculator. To anticipate maximum real-world power loads and capacities...
Power basics for IT professionals
Page 39
Kilowatt-hours (kWh): A measurement for work that flows from the utility into the building or home. HP highly recommends proper wiring techniques and a permanent ground connection. (The current that has been done over time. Live (hot) contact (conductor, core, line, pin, pole,... the chassis, known as low voltage. MWh: Megawatt-hour Modular PDU: Modular power distribution units consist of this book is a British or Australian term. The 2005 volume of a control core that connects to the power bus (or UPS) and extension bars that has been done over time. Kilowatt (kW): As a ...
Kilowatt-hours (kWh): A measurement for work that flows from the utility into the building or home. HP highly recommends proper wiring techniques and a permanent ground connection. (The current that has been done over time. Live (hot) contact (conductor, core, line, pin, pole,... the chassis, known as low voltage. MWh: Megawatt-hour Modular PDU: Modular power distribution units consist of this book is a British or Australian term. The 2005 volume of a control core that connects to the power bus (or UPS) and extension bars that has been done over time. Kilowatt (kW): As a ...
ProLiant High Availability: The IT Imperative
Page 4
... logical disk drive, providing increased performance and availability. HP servers include counter-rotating fans with ball bearings are integrated on ProLiant servers and increasing server availability, visit www.hp.com/go/proliantavailability or call 1-866-625-4090 4a © Copyright 2005 Hewlett-Packard Development Company, L.P. ProLiant servers allow the addition of a redundant power supply, or...
... logical disk drive, providing increased performance and availability. HP servers include counter-rotating fans with ball bearings are integrated on ProLiant servers and increasing server availability, visit www.hp.com/go/proliantavailability or call 1-866-625-4090 4a © Copyright 2005 Hewlett-Packard Development Company, L.P. ProLiant servers allow the addition of a redundant power supply, or...
Server virtualization technologies for x86-based HP BladeSystem and HP ProLiant servers, 3rd edition
Page 5
...machine as a sample of vendor implementations CPU binary translation VMware ESX Hosted-OS, application-layer abstraction Microsoft Virtual Server 2005 R2 VMware Server (formerly VMware GSX) Vendor URLs www.vmware.com www.microsoft.com/virtualserver www.vmware.com/products/... managed using the ProLiant-integrated VMware ESXi, the WBEM providers in late 2009. ProLiant iVirtualization leverages customers' familiar ProLiant server management tools so that any of the Microsoft Hyper-V Server hypervisor in HP SIM are VMware ESXi and Citrix XenServer. HP expects to easily ...
...machine as a sample of vendor implementations CPU binary translation VMware ESX Hosted-OS, application-layer abstraction Microsoft Virtual Server 2005 R2 VMware Server (formerly VMware GSX) Vendor URLs www.vmware.com www.microsoft.com/virtualserver www.vmware.com/products/... managed using the ProLiant-integrated VMware ESXi, the WBEM providers in late 2009. ProLiant iVirtualization leverages customers' familiar ProLiant server management tools so that any of the Microsoft Hyper-V Server hypervisor in HP SIM are VMware ESXi and Citrix XenServer. HP expects to easily ...
The Intel processor roadmap for industry-standard servers technology brief, 10 edition
Page 11
... threads on the core by virtue of a two-core processor is because the multiple threads compete for available compute resources, which limits the increase in 2005. The second core's additional capacity reduces competition for single-core architectures to schedule two threads on each execution core as two separate "logical" processors with...
... threads on the core by virtue of a two-core processor is because the multiple threads compete for available compute resources, which limits the increase in 2005. The second core's additional capacity reduces competition for single-core architectures to schedule two threads on each execution core as two separate "logical" processors with...
The Intel processor roadmap for industry-standard servers technology brief, 10 edition
Page 22
... and services. Resource description Web address ProLiant servers home page www.hp.com/servers/proliant Power Regulator for ProLiant Servers ISS Technology Papers http://h20000.www2.hp.com/bc/docs/support/Su pportManual/c00300430/c00300430.pdf www.hp.com/servers/technology Call to action Send... comments about this paper to TechCom@HP.com. © 2002, 2005, 2006, ...
... and services. Resource description Web address ProLiant servers home page www.hp.com/servers/proliant Power Regulator for ProLiant Servers ISS Technology Papers http://h20000.www2.hp.com/bc/docs/support/Su pportManual/c00300430/c00300430.pdf www.hp.com/servers/technology Call to action Send... comments about this paper to TechCom@HP.com. © 2002, 2005, 2006, ...
HP ProLiant Servers Troubleshooting Guide
Page 3
... 375445-xx6 (September 2007) ...10 375445-xx5 (June 2006) ...10 375445-xx4 (May 2006)...11 375445-xx3 (September 2005) ...11 Getting started...12 HP ProLiant 100 Series Server troubleshooting information 12 How to use this guide ...12 Pre-diagnostic steps ...13 Important safety information...13 Symptom information...29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32 Hardware problems ...36 Procedures for all ProLiant servers...36 Power problems ...36 Power source problems ...36 Power supply problems ...36 UPS problems ...37 General hardware problems ...38 Contents...
... 375445-xx6 (September 2007) ...10 375445-xx5 (June 2006) ...10 375445-xx4 (May 2006)...11 375445-xx3 (September 2005) ...11 Getting started...12 HP ProLiant 100 Series Server troubleshooting information 12 How to use this guide ...12 Pre-diagnostic steps ...13 Important safety information...13 Symptom information...29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32 Hardware problems ...36 Procedures for all ProLiant servers...36 Power problems ...36 Power source problems ...36 Power supply problems ...36 UPS problems ...37 General hardware problems ...38 Contents...
HP ProLiant Servers Troubleshooting Guide
Page 11
375445-xx4 (May 2006) The fourth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx4, included the following additions: • Hot-plug SAS and SATA hard drive LED combinations (on page 19) • ...; New error messages in ADU error messages (on page 90) and POST error messages and beep codes (on page 114) 375445-xx3 (September 2005) The third edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx3, included the following changes: • Updated SCSI hard drive guidelines • Added hot-plug SCSI...
375445-xx4 (May 2006) The fourth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx4, included the following additions: • Hot-plug SAS and SATA hard drive LED combinations (on page 19) • ...; New error messages in ADU error messages (on page 90) and POST error messages and beep codes (on page 114) 375445-xx3 (September 2005) The third edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx3, included the following changes: • Updated SCSI hard drive guidelines • Added hot-plug SCSI...