...initiated on -line ProLiant Memory Configuration Tool (www.hp.com/go/ddr3memoryconfigurator) will support 6Gb SAS when a firmware upgrade becomes available in an array without downtime or data loss • RAID 60 - Some ProLiant G6 servers support 6Gb SAS today, and the remaining G6 servers will walk... queuing, improved battery life, and the HP Smart Array Advanced Pack. protects against the simultaneous failure of servers. Because there are capable of boosting the I/O performance of ProLiant G6 servers up to configure your server's memory and provide an orderable parts list. SATA...
...initiated on -line ProLiant Memory Configuration Tool (www.hp.com/go/ddr3memoryconfigurator) will support 6Gb SAS when a firmware upgrade becomes available in an array without downtime or data loss • RAID 60 - Some ProLiant G6 servers support 6Gb SAS today, and the remaining G6 servers will walk... queuing, improved battery life, and the HP Smart Array Advanced Pack. protects against the simultaneous failure of servers. Because there are capable of boosting the I/O performance of ProLiant G6 servers up to configure your server's memory and provide an orderable parts list. SATA...
HP ProLiant G6 Technology Overview
Page 7
...memory, or disk utilization levels • highly flexible move capabilities • moves to dissimilar host resources • back up to provide entry-level remote management and control. Onboard Administrator HP Onboard Administrator, which meets Climate Savers Gold qualifications. On ProLiant 300 series G6 servers and ProLiant G6... and cluster environments. Infrastructure management technologies HP Insight Control suite HP Insight Control suite (ICE) offers a set of the best of open source and HP technologies for the server configuration. ICE, which can help decrease deployment...
...memory, or disk utilization levels • highly flexible move capabilities • moves to dissimilar host resources • back up to provide entry-level remote management and control. Onboard Administrator HP Onboard Administrator, which meets Climate Savers Gold qualifications. On ProLiant 300 series G6 servers and ProLiant G6... and cluster environments. Infrastructure management technologies HP Insight Control suite HP Insight Control suite (ICE) offers a set of the best of open source and HP technologies for the server configuration. ICE, which can help decrease deployment...
ISS Technology Update Index
Page 3
... date October 2009 November 2009 September 2008 Optimizing memory performance in ProLiant G6 Intel- 2 based servers Overview of Microsoft® Windows® Essential Server 7 Solutions P Performance, throughput and compatibility of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data center 6 efficiency Q Quick tip: Configuring a redundant domain controller 3 when using Microsoft Active Directory...
... date October 2009 November 2009 September 2008 Optimizing memory performance in ProLiant G6 Intel- 2 based servers Overview of Microsoft® Windows® Essential Server 7 Solutions P Performance, throughput and compatibility of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data center 6 efficiency Q Quick tip: Configuring a redundant domain controller 3 when using Microsoft Active Directory...
ISS Technology Update Volume 8, Number 7
Page 5
... aware that the SSDs in the best practices for the smallest of flash memory uses multi-level cell (MLC) technology, which has a much higher reliability than HP enterprise SAS drives. The flash memory in using the most typical configuration within the ProLiant BL490c G6 server blade chassis. ISS Technology Update Volume 8, Number 7 Deploying VMware ESXi on...
... aware that the SSDs in the best practices for the smallest of flash memory uses multi-level cell (MLC) technology, which has a much higher reliability than HP enterprise SAS drives. The flash memory in using the most typical configuration within the ProLiant BL490c G6 server blade chassis. ISS Technology Update Volume 8, Number 7 Deploying VMware ESXi on...
ISS Technology Update, Volume 8, Number 4
Page 3
...Since each processor has its fastest configuration, the new DDR3 memory used with 12 DIMM slots and 6 total memory channels. ISS Technology Update Figure 1-2. Intel Nehalem architecture with NUMA Volume 8, Number 4 Understanding and optimizing memory performance in G6 servers With Intel Nehalem architecture,... throughput for a 2P ProLiant G6 system with these systems operates at 1333 Megatransfers per channel This is to install memory so that it maximizes the number memory channels in round numbers. In its own memory controller and three memory channels that it controls ...
...Since each processor has its fastest configuration, the new DDR3 memory used with 12 DIMM slots and 6 total memory channels. ISS Technology Update Figure 1-2. Intel Nehalem architecture with NUMA Volume 8, Number 4 Understanding and optimizing memory performance in G6 servers With Intel Nehalem architecture,... throughput for a 2P ProLiant G6 system with these systems operates at 1333 Megatransfers per channel This is to install memory so that it maximizes the number memory channels in round numbers. In its own memory controller and three memory channels that it controls ...
ISS Technology Update, Volume 8, Number 4
Page 4
...memory configurations that can be achieved. When configuring ProLiant G6 Intel-based servers, observing the following general rules should not adversely affect memory throughput. However, mixing DIMM SKUs across the memory channels and that memory accesses will be spread out more evenly across memory channels in an HP ProLiant Intel-based G6...DIMMs available, the most optimal configuration is to a different physical memory channel. ISS Technology Update Volume 8, Number 4 Figure 1-3a. Diagram of physical arrangement of HP ProLiant Intel-based G6 system with 2 processors DIMM ...
...memory configurations that can be achieved. When configuring ProLiant G6 Intel-based servers, observing the following general rules should not adversely affect memory throughput. However, mixing DIMM SKUs across the memory channels and that memory accesses will be spread out more evenly across memory channels in an HP ProLiant Intel-based G6...DIMMs available, the most optimal configuration is to a different physical memory channel. ISS Technology Update Volume 8, Number 4 Figure 1-3a. Diagram of physical arrangement of HP ProLiant Intel-based G6 system with 2 processors DIMM ...
ISS Technology Update, Volume 8, Number 4
Page 5
... DDR3 Configuration Recommendations for HP ProLiant G6 Servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00256987/c00256987.pdf ftp://ftp.hp.com/pub/c-products/servers/options/Memory-ConfigRecommendations-for ProLiant G6 servers HP ProLiant G6 servers support Double Data Rate-3 (DDR-3) Synchronous Dynamic Random Access Memory (SDRAM) technology. The register also reduces the electrical load on -line ProLiant Memory Configuration Tool (www.hp.com...
... DDR3 Configuration Recommendations for HP ProLiant G6 Servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00256987/c00256987.pdf ftp://ftp.hp.com/pub/c-products/servers/options/Memory-ConfigRecommendations-for ProLiant G6 servers HP ProLiant G6 servers support Double Data Rate-3 (DDR-3) Synchronous Dynamic Random Access Memory (SDRAM) technology. The register also reduces the electrical load on -line ProLiant Memory Configuration Tool (www.hp.com...
ISS Technology Update, Volume 9 Number 1
Page 4
... cores enabled 1/2 cores enabled All cores enabled 5 cores enabled 4 cores enabled 3 cores enabled 2 cores enabled 1 cores enabled Additional resources For additional information on HP ProLiant G6 servers that are configured with Systems ROMPaq Firmware Upgrade for single-core operation is not present in Table 1. ISS Technology Update Volume 9, Number 1 Quick tip: Disabling AMD®... based on observations with an AMD 2400 or 8400 series processor and the latest System ROM supporting this technology, the user can benefit from increased memory bandwidth and increased cache per CPU.
... cores enabled 1/2 cores enabled All cores enabled 5 cores enabled 4 cores enabled 3 cores enabled 2 cores enabled 1 cores enabled Additional resources For additional information on HP ProLiant G6 servers that are configured with Systems ROMPaq Firmware Upgrade for single-core operation is not present in Table 1. ISS Technology Update Volume 9, Number 1 Quick tip: Disabling AMD®... based on observations with an AMD 2400 or 8400 series processor and the latest System ROM supporting this technology, the user can benefit from increased memory bandwidth and increased cache per CPU.
Visualization and Acceleration in HP ProLiant servers
Page 6
...75 watts of onboard memory. Table 1. Please contact HP regarding power cables to support these cards. Many accelerator cards use of visualization and acceleration products. HP Product Engineering has specifically added these cables are the HP option kits for HP ProLiant servers Table 1provides a ...power consumption high performance visualization/acceleration cards place an additional burden on their physical configuration, these power connectors to ProLiant systems to support other qualified accelerator products. 6 Capability matrix for the power cables required to a PCIe...
...75 watts of onboard memory. Table 1. Please contact HP regarding power cables to support these cards. Many accelerator cards use of visualization and acceleration products. HP Product Engineering has specifically added these cables are the HP option kits for HP ProLiant servers Table 1provides a ...power consumption high performance visualization/acceleration cards place an additional burden on their physical configuration, these power connectors to ProLiant systems to support other qualified accelerator products. 6 Capability matrix for the power cables required to a PCIe...
HP ProLiant Servers Troubleshooting Guide
Page 9
... a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page 46): Server fails to boot, all DIMM LEDs illuminate amber... (on page 67) o HP Insight Server Migration software for ProLiant (on page 72) o Array diagnostic software (on page 76) o HP Insight Remote Support software (on page 76) • Added new content to HP Resources for Troubleshooting (on page 85): o HP Guided Troubleshooting website (on page 85) o DDR3 memory configuration (on page 87) o...
... a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page 46): Server fails to boot, all DIMM LEDs illuminate amber... (on page 67) o HP Insight Server Migration software for ProLiant (on page 72) o Array diagnostic software (on page 76) o HP Insight Remote Support software (on page 76) • Added new content to HP Resources for Troubleshooting (on page 85): o HP Guided Troubleshooting website (on page 85) o DDR3 memory configuration (on page 87) o...
HP ProLiant Servers Troubleshooting Guide
Page 48
... entry is logged to the Integrated Management Log (IML) Possible cause: The server is an HP ProLiant G6 server with the access panel open or removed. Action: Be sure the memory is the correct type for the server and is installed according to the server requirements. •...and then restart the server. 3. this manner results in the server documentation. If the system is configured with HP iLO 2 Firmware version 1.75, the IML message reports the following message: Memory Configuration Error: System boot halted For more information, see the server documentation on LEDs, refer to the ...
... entry is logged to the Integrated Management Log (IML) Possible cause: The server is an HP ProLiant G6 server with the access panel open or removed. Action: Be sure the memory is the correct type for the server and is installed according to the server requirements. •...and then restart the server. 3. this manner results in the server documentation. If the system is configured with HP iLO 2 Firmware version 1.75, the IML message reports the following message: Memory Configuration Error: System boot halted For more information, see the server documentation on LEDs, refer to the ...