HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 94
Specifications are provided for the HP ProLiant ML150 G6 server. 6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • Power supply • Memory • Processor • Optical drive • SAS drive • SATA drive • SAS/SATA controller card System Unit Table...
Specifications are provided for the HP ProLiant ML150 G6 server. 6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • Power supply • Memory • Processor • Optical drive • SAS drive • SATA drive • SAS/SATA controller card System Unit Table...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 99
Table 6-6 Power Supply Specifications (750W) Parameter Temperature range: Operating Shipping Relative humidity: Operating Non-operating Description +5°C to +50°C -40°C to +85°C 5 % to 95 % (non-... E5502 Operating Frequency 1.86 GHz QPI 4.8GT/s On-die L2 cache 4 MB Thermal Design Point (power) 80 watts Physical and Operating Specifications 99 CAUTION: Two-processor (2P) systems must be configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel...
Table 6-6 Power Supply Specifications (750W) Parameter Temperature range: Operating Shipping Relative humidity: Operating Non-operating Description +5°C to +50°C -40°C to +85°C 5 % to 95 % (non-... E5502 Operating Frequency 1.86 GHz QPI 4.8GT/s On-die L2 cache 4 MB Thermal Design Point (power) 80 watts Physical and Operating Specifications 99 CAUTION: Two-processor (2P) systems must be configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel...
HP ProLiant ML 150 G6 Processor Installation Card
Page 1
...) Item Description 1 Power supply unit 2 Processor 1 3 Processor 2 4 System board 5 Air baffle Figure 2 System board Item Description 1 CPU 1 2 CPU 2 3 SYS FAN 1 J54 4 SYS FAN 2 J44 (Redundant) 5 SYS FAN 3 J38 Installing the Processor 1. Release the rear thumbscrews and remove the access panel. 7. Press the load lever, and released from the system chassis. 5. HP ProLiant ML150 G6 Server Processor...
...) Item Description 1 Power supply unit 2 Processor 1 3 Processor 2 4 System board 5 Air baffle Figure 2 System board Item Description 1 CPU 1 2 CPU 2 3 SYS FAN 1 J54 4 SYS FAN 2 J44 (Redundant) 5 SYS FAN 3 J38 Installing the Processor 1. Release the rear thumbscrews and remove the access panel. 7. Press the load lever, and released from the system chassis. 5. HP ProLiant ML150 G6 Server Processor...
HP ProLiant ML150 G6 server Installation Sheet
Page 1
... CPU2_DIMM slot 4B 17 CPU2_DIMM slot 3E 18 CPU2_DIMM slot 2A 19 CPU2_DIMM slot 1D 20 Processor 2 socket 21 Power supply connector (8-Pin) 22 Power Supply connector (24-pin) 23 Battery Item Description 24 Internal USB connector 25 SATA 6_ODD 2 connector 26 SATA 5_ODD... slot x 8 Full-length, Fullheight slot x 16 Full-length, Fullheight slot x 8 Full-length, Fullheight slot x 8 Half-length, Full- HP ProLiant ML150 G6 Server Installation Sheet Part number: 501527-001 March 2009 First Edition Configuring the server Refer to halt screen movement. Connect the keyboard, mouse, and monitor...
... CPU2_DIMM slot 4B 17 CPU2_DIMM slot 3E 18 CPU2_DIMM slot 2A 19 CPU2_DIMM slot 1D 20 Processor 2 socket 21 Power supply connector (8-Pin) 22 Power Supply connector (24-pin) 23 Battery Item Description 24 Internal USB connector 25 SATA 6_ODD 2 connector 26 SATA 5_ODD... slot x 8 Full-length, Fullheight slot x 16 Full-length, Fullheight slot x 8 Full-length, Fullheight slot x 8 Half-length, Full- HP ProLiant ML150 G6 Server Installation Sheet Part number: 501527-001 March 2009 First Edition Configuring the server Refer to halt screen movement. Connect the keyboard, mouse, and monitor...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 6
... both the minimum and maximum power consumption for the server. The ProLiant power management system constantly monitors server power use and uses P-states and/or clock throttling to control overall system power consumption. Minimum and maximum power consumption for a server To establish a set by the enclosure's Onboard Administrator for that the server power supply is below the present...
... both the minimum and maximum power consumption for the server. The ProLiant power management system constantly monitors server power use and uses P-states and/or clock throttling to control overall system power consumption. Minimum and maximum power consumption for a server To establish a set by the enclosure's Onboard Administrator for that the server power supply is below the present...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 8
...these numbers is between the minimum power and the power supply rating of 320, 170, 305, and 320 watts respectively. 8 With group power capping, each server in ProLiant servers Basic Power Capping is assigned an individual power cap. Support for Power Capping in the group is supported... matrix: http://h18004.www1.hp.com/products/servers/management/dynamic-power-capping/support.html Group power capping for the servers until they are capable of servers that server's minimum and maximum power consumption. When working with their aggregated power supply rating. Figure 3 shows ...
...these numbers is between the minimum power and the power supply rating of 320, 170, 305, and 320 watts respectively. 8 With group power capping, each server in ProLiant servers Basic Power Capping is assigned an individual power cap. Support for Power Capping in the group is supported... matrix: http://h18004.www1.hp.com/products/servers/management/dynamic-power-capping/support.html Group power capping for the servers until they are capable of servers that server's minimum and maximum power consumption. When working with their aggregated power supply rating. Figure 3 shows ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 9
...etc.) 9 The Onboard Administrator (OA) then actively manages these power caps. Total power consumption for an enclosure is a higher level of the following: The server blades I/O peripherals for HP BladeSystem enclosures. Apportioning a group power cap to individual servers in the enclosure. In another sense, ...200 Servers as a Group 3500 watts (Group power supply maximum) 1375 watts (Group maximum) 1115 watts (User set group power cap) 1000 400 320 200 725 watts (Group minimum) For ProLiant ML and DL servers, group power capping apportionment works exactly the same on servers ...
...etc.) 9 The Onboard Administrator (OA) then actively manages these power caps. Total power consumption for an enclosure is a higher level of the following: The server blades I/O peripherals for HP BladeSystem enclosures. Apportioning a group power cap to individual servers in the enclosure. In another sense, ...200 Servers as a Group 3500 watts (Group power supply maximum) 1375 watts (Group maximum) 1115 watts (User set group power cap) 1000 400 320 200 725 watts (Group minimum) For ProLiant ML and DL servers, group power capping apportionment works exactly the same on servers ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 14
Figure 7. Setting a power cap for a group of the entire group. Using the IPM interface, an administrator can apply a power cap to the server group that is between the minimum power and the power supply rating of servers Insight Power Manger is illustrated in Insight Power Manager 14 Setting a group power cap in Figure 7. This is the sole tool for setting power caps for groups ProLiant ML and DL servers.
Figure 7. Setting a power cap for a group of the entire group. Using the IPM interface, an administrator can apply a power cap to the server group that is between the minimum power and the power supply rating of servers Insight Power Manger is illustrated in Insight Power Manager 14 Setting a group power cap in Figure 7. This is the sole tool for setting power caps for groups ProLiant ML and DL servers.
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 21
...the HP 2250W power supplies' specification requires delivering 7836 watts to the enclosure, typically by setting an enclosure power cap. Using Enclosure Dynamic Power Capping in power provisioning Dynamic Power Capping can control server power consumption quickly enough to prevent transient server power demands... Enclosure Dynamic Power Capping, an administrator can essentially cap the electrical provisioning required for 8 ProLiant DL580 G5 servers (based on HP Power Calculator) 3384 watts Maximum power consumption when capping to average 1900 watts Savings in power capacity 1484 watts...
...the HP 2250W power supplies' specification requires delivering 7836 watts to the enclosure, typically by setting an enclosure power cap. Using Enclosure Dynamic Power Capping in power provisioning Dynamic Power Capping can control server power consumption quickly enough to prevent transient server power demands... Enclosure Dynamic Power Capping, an administrator can essentially cap the electrical provisioning required for 8 ProLiant DL580 G5 servers (based on HP Power Calculator) 3384 watts Maximum power consumption when capping to average 1900 watts Savings in power capacity 1484 watts...
HP ProLiant G6 Technology Overview
Page 1
... ProLiant G6 servers ...3 Intel® Xeon® processor 5500 series ...3 Intel QuickPath Technology...3 Integrated memory controller ...4 Three-level cache hierarchy...4 Intel Hyper-Threading Technology 4 Intel Turbo Boost Technology ...4 Dynamic Power Management ...4 DDR-3 memory technology ...4 Smart Array technology ...5 Smart Array controllers ...5 HP SAS Expander Card ...5 Thermal Logic technologies ...6 Dynamic Power Capping ...6 'Sea of Sensors' ...6 Common Slot Power Supplies...
... ProLiant G6 servers ...3 Intel® Xeon® processor 5500 series ...3 Intel QuickPath Technology...3 Integrated memory controller ...4 Three-level cache hierarchy...4 Intel Hyper-Threading Technology 4 Intel Turbo Boost Technology ...4 Dynamic Power Management ...4 DDR-3 memory technology ...4 Smart Array technology ...5 Smart Array controllers ...5 HP SAS Expander Card ...5 Thermal Logic technologies ...6 Dynamic Power Capping ...6 'Sea of Sensors' ...6 Common Slot Power Supplies...
HP ProLiant G6 Technology Overview
Page 2
... productivity out of each ProLiant G6 server and intelligently manages power to share a range of highly efficient power supplies. Unite physical and virtual environments to maximize productivity HP infrastructure and management tools can help you to right-size the power supply for each server to 50%. By uniting your business ProLiant G6 servers deliver up to maximize power efficiency, and it...
... productivity out of each ProLiant G6 server and intelligently manages power to share a range of highly efficient power supplies. Unite physical and virtual environments to maximize productivity HP infrastructure and management tools can help you to right-size the power supply for each server to 50%. By uniting your business ProLiant G6 servers deliver up to maximize power efficiency, and it...
HP ProLiant G6 Technology Overview
Page 6
... double the power efficiency of servers. Common Slot Power Supplies Many ProLiant G6 servers have a specified trip time of this processor-driven model and controls overall server power consumption using HP iLO Advanced or Insight Power Manager (IPM). Thermal Logic technologies HP is extending Thermal Logic technologies-originally offered on the HP BladeSystem-to draw more ProLiant G6 servers. Dynamic Power Capping takes...
... double the power efficiency of servers. Common Slot Power Supplies Many ProLiant G6 servers have a specified trip time of this processor-driven model and controls overall server power consumption using HP iLO Advanced or Insight Power Manager (IPM). Thermal Logic technologies HP is extending Thermal Logic technologies-originally offered on the HP BladeSystem-to draw more ProLiant G6 servers. Dynamic Power Capping takes...
HP ProLiant G6 Technology Overview
Page 7
... parameters. Use these control surfaces with your own internally developed deployment scripts or with every ProLiant G6 server, is complemented by allowing you control over four aspects of IT service to the business. The AC power supplies work with HP Systems Insight Manager, RBSU, ORCA, and the embedded Baseboard Management Controller (BMC) to right-size...
... parameters. Use these control surfaces with your own internally developed deployment scripts or with every ProLiant G6 server, is complemented by allowing you control over four aspects of IT service to the business. The AC power supplies work with HP Systems Insight Manager, RBSU, ORCA, and the embedded Baseboard Management Controller (BMC) to right-size...
HP ProLiant G6 Technology Overview
Page 8
...blade to deliver emergency updates of change -ready infrastructure also lays the foundation for power supplies. Using the 2 Advanced remote control functionality requires an iLO Advanced license for ProLiant ML/DL servers and an iLO Advanced for BladeSystem license for Insight Dynamics-VSE ...operating system deployment. Manage it was not cost-effective before • Performing energy-aware capacity planning HP ID-VSE includes HP Insight Control suite and HP Systems Insight Manager. Virtual Connect and Virtual Connect Enterprise Manager must be purchased separately. Each Flex-...
...blade to deliver emergency updates of change -ready infrastructure also lays the foundation for power supplies. Using the 2 Advanced remote control functionality requires an iLO Advanced license for ProLiant ML/DL servers and an iLO Advanced for BladeSystem license for Insight Dynamics-VSE ...operating system deployment. Manage it was not cost-effective before • Performing energy-aware capacity planning HP ID-VSE includes HP Insight Control suite and HP Systems Insight Manager. Virtual Connect and Virtual Connect Enterprise Manager must be purchased separately. Each Flex-...
HP ProLiant Intel-based 100-series G6 server technology
Page 1
HP ProLiant 100-series Intel-based G6 server technology Technology brief, 3rd edition Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...4 QuickPath Interconnect controller ...4 Hyper ... SAS-2 standard ...12 New generation HP Smart Array controllers 12 Battery backed write cache ...13 Zero Memory RAID...13 Software RAID ...13 Smart Array Advanced Pack ...13 Networking technologies ...14 Power and thermal technologies ...14 Efficient power delivery...14 Common Slot power supplies...15 Redundant power operation ...16 Voltage regulation ...16 ...
HP ProLiant 100-series Intel-based G6 server technology Technology brief, 3rd edition Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...4 QuickPath Interconnect controller ...4 Hyper ... SAS-2 standard ...12 New generation HP Smart Array controllers 12 Battery backed write cache ...13 Zero Memory RAID...13 Software RAID ...13 Smart Array Advanced Pack ...13 Networking technologies ...14 Power and thermal technologies ...14 Efficient power delivery...14 Common Slot power supplies...15 Redundant power operation ...16 Voltage regulation ...16 ...
HP ProLiant Intel-based 100-series G6 server technology
Page 2
... IPMI 2.0 and DCMI 1.0...23 Server deployment ...23 HP ProLiant Easy Set-up CDs ...23 OS support ...23 DL1000 Multi Node server design for scale out computing 24 Chassis design...24 Shared power ...25 Riser options ...25 Fans and fan control...25 Power supply support ...26 Advanced Power Management...26 Power Interface Controller ...26 Summary ...27 For more...
... IPMI 2.0 and DCMI 1.0...23 Server deployment ...23 HP ProLiant Easy Set-up CDs ...23 OS support ...23 DL1000 Multi Node server design for scale out computing 24 Chassis design...24 Shared power ...25 Riser options ...25 Fans and fan control...25 Power supply support ...26 Advanced Power Management...26 Power Interface Controller ...26 Summary ...27 For more...
HP ProLiant Intel-based 100-series G6 server technology
Page 3
... from the BIOS setup utility that incorporate common form factor components • "Right Size" Common Slot power supplies in Intel-based HP ProLiant 100-series G6 servers. Abstract This technology brief describes the key technologies implemented in multiple sizes to provide the required amount of...ProLiant 100-series servers, see the HP technology brief titled "The Intel processor roadmap for each integrated memory controller to its dedicated memory provide a total bandwidth of this writing, the Intel-based 100-series G6 servers include the ProLiant DL120, DL160, DL180, ML110, ML150...
... from the BIOS setup utility that incorporate common form factor components • "Right Size" Common Slot power supplies in Intel-based HP ProLiant 100-series G6 servers. Abstract This technology brief describes the key technologies implemented in multiple sizes to provide the required amount of...ProLiant 100-series servers, see the HP technology brief titled "The Intel processor roadmap for each integrated memory controller to its dedicated memory provide a total bandwidth of this writing, the Intel-based 100-series G6 servers include the ProLiant DL120, DL160, DL180, ML110, ML150...
HP ProLiant Intel-based 100-series G6 server technology
Page 14
... performance of video on this and other HP network adapter products, go to manage power in ProLiant 100-series G6 servers or reduce capabilities to bring the components to split the RAID storage across multiple external boxes. Common Slot power supplies are not hot-pluggable. It requires a minimum of power and thermal technologies, and components to www...
... performance of video on this and other HP network adapter products, go to manage power in ProLiant 100-series G6 servers or reduce capabilities to bring the components to split the RAID storage across multiple external boxes. Common Slot power supplies are not hot-pluggable. It requires a minimum of power and thermal technologies, and components to www...
HP ProLiant Intel-based 100-series G6 server technology
Page 15
... power supplies The HP G6 Common Slot power strategy provides power supply commonality across supported ProLiant G6 server lines. With the exception of spares the customer must keep in ProLiant G6 servers. Power/Efficiency curve for the 750W power supply shown in Figure 5 provides an example of the high levels of power efficiency present in all new power supplies used in the data center. All ProLiant 100-series G6...
... power supplies The HP G6 Common Slot power strategy provides power supply commonality across supported ProLiant G6 server lines. With the exception of spares the customer must keep in ProLiant G6 servers. Power/Efficiency curve for the 750W power supply shown in Figure 5 provides an example of the high levels of power efficiency present in all new power supplies used in the data center. All ProLiant 100-series G6...
HP ProLiant Intel-based 100-series G6 server technology
Page 16
By introducing these different wattage power supplies, HP gives users the option to choose a power supply that zone. Users can result in a given fan zone. Redundant power operation In supported ProLiant 100-series G6 servers, redundant power supplies operate in AC input power. The 100series G6 servers have Common Slot power supply compatibility, and not all servers will support all available power supply wattages. Modern digital voltage...
By introducing these different wattage power supplies, HP gives users the option to choose a power supply that zone. Users can result in a given fan zone. Redundant power operation In supported ProLiant 100-series G6 servers, redundant power supplies operate in AC input power. The 100series G6 servers have Common Slot power supply compatibility, and not all servers will support all available power supply wattages. Modern digital voltage...