User Manual
Page 5
... 2-17 Wall mounting the Series 2600-8-PWR Switch 2-18 Horizontal Surface Mounting 2-19 5. Connect the Switch to a Power Source 2-19 iii Installing or Removing mini-GBICs 2-7 3. Verify the Switch Passes Self Test 2-9 LED Behavior 2-10 4. Contents 1 Introducing the Switch Front of the Switch 1-10 Console Port 1-11 Power Connector 1-11 Switch...
... 2-17 Wall mounting the Series 2600-8-PWR Switch 2-18 Horizontal Surface Mounting 2-19 5. Connect the Switch to a Power Source 2-19 iii Installing or Removing mini-GBICs 2-7 3. Verify the Switch Passes Self Test 2-9 LED Behavior 2-10 4. Contents 1 Introducing the Switch Front of the Switch 1-10 Console Port 1-11 Power Connector 1-11 Switch...
User Manual
Page 6
6. Connect the Network Cables 2-20 Using the RJ-45 Connectors 2-20 Connecting Cables to mini-GBICs 2-21 7. (Optional) Connect a Redundant Power Supply to a Series 2600-PWR Switch 2-21 RPS/EPS Operation 2-22 Operating Characteristics of the 600 RPS/EPS (J8168A 2-22 ...
6. Connect the Network Cables 2-20 Using the RJ-45 Connectors 2-20 Connecting Cables to mini-GBICs 2-21 7. (Optional) Connect a Redundant Power Supply to a Series 2600-PWR Switch 2-21 RPS/EPS Operation 2-22 Operating Characteristics of the 600 RPS/EPS (J8168A 2-22 ...
User Manual
Page 9
...48) 24 26 49 M 50 M MiniGBIC Ports 36 38 (all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are HP Auto-MDIX) Link 1 Mode 2 3 4 Link 5 Mode 6 7 8 Dual-Personality Port: 10/100/1000-T (T) or Mini-GBIC (M) (Port 9T is IEEE Auto MDI/MDIX) Link 9T Mode 9M Link Mode ! Use ...only one (T or M) for each Gigabit port Power Fault hp procurve switch 2626-PWR J8164A PoE Status RPS Act EPS LED Mode FDx Fan...
...48) 24 26 49 M 50 M MiniGBIC Ports 36 38 (all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are HP Auto-MDIX) Link 1 Mode 2 3 4 Link 5 Mode 6 7 8 Dual-Personality Port: 10/100/1000-T (T) or Mini-GBIC (M) (Port 9T is IEEE Auto MDI/MDIX) Link 9T Mode 9M Link Mode ! Use ...only one (T or M) for each Gigabit port Power Fault hp procurve switch 2626-PWR J8164A PoE Status RPS Act EPS LED Mode FDx Fan...
User Manual
Page 10
... provide up to keep the switch running should fail. The Series 2600-PWR Switches are either auto-sensing 10/100/1000Base-T RJ-45, or mini-GBIC (Small Form Factor Pluggable (SFP) ports in an Ethernet application). As an EPS unit, the 600 RPS/EPS and the 610 EPS can provide up...
... provide up to keep the switch running should fail. The Series 2600-PWR Switches are either auto-sensing 10/100/1000Base-T RJ-45, or mini-GBIC (Small Form Factor Pluggable (SFP) ports in an Ethernet application). As an EPS unit, the 600 RPS/EPS and the 610 EPS can provide up...
User Manual
Page 11
...-X) 48 ! Use only one (T or M) for Port 9 10/100Base-TX RJ-45 ports1 Dual-personality port (1000Base-T2 or mini-GBIC) 1 All 10/100Base-TX RJ-45 ports have the HP Auto MDIX feature. 2 10/100/1000Base-T ports have the IEEE Auto MDI/MDI-X feature. 1-3 Front of the Switch Power and Fault... and indicator LEDs 10/100Base-TX RJ-45 ports1 Dual-personality ports (1000Base-T2 or mini-GBIC) Power and Fault LEDs RPS, EPS, Fan and Test Status LEDs Switch port LEDs ProCurve Switch 2650-PWR hp procurve 1 3 5 7 9 11 13 15 17 19 21 23 Link|Mode 25 27 29 31 33 35...
...-X) 48 ! Use only one (T or M) for Port 9 10/100Base-TX RJ-45 ports1 Dual-personality port (1000Base-T2 or mini-GBIC) 1 All 10/100Base-TX RJ-45 ports have the HP Auto MDIX feature. 2 10/100/1000Base-T ports have the IEEE Auto MDI/MDI-X feature. 1-3 Front of the Switch Power and Fault... and indicator LEDs 10/100Base-TX RJ-45 ports1 Dual-personality ports (1000Base-T2 or mini-GBIC) Power and Fault LEDs RPS, EPS, Fan and Test Status LEDs Switch port LEDs ProCurve Switch 2650-PWR hp procurve 1 3 5 7 9 11 13 15 17 19 21 23 Link|Mode 25 27 29 31 33 35...
User Manual
Page 12
...off and the switch will still have the "HP Auto MDIX" feature, which operates the same as the "HP Auto-MDIX" feature. If a mini-GBIC is installed, it is enabled and the ...associated RJ-45 connector is powered on for the component with the fault will be functional.) The normal state; If the mini-GBIC...that you can use either the 10/100/1000Base-T RJ-45 connector, or install a supported ProCurve mini-GBIC for more information. 1-4 Switch Status LEDs Switch LEDs Power (green) Fault (orange) State On Off...
...off and the switch will still have the "HP Auto MDIX" feature, which operates the same as the "HP Auto-MDIX" feature. If a mini-GBIC is installed, it is enabled and the ...associated RJ-45 connector is powered on for the component with the fault will be functional.) The normal state; If the mini-GBIC...that you can use either the 10/100/1000Base-T RJ-45 connector, or install a supported ProCurve mini-GBIC for more information. 1-4 Switch Status LEDs Switch LEDs Power (green) Fault (orange) State On Off...
User Manual
Page 13
... on /off . The 600 RPS/EPS is present but may be powering the unit - the mini-GBIC is tested when it . The switch self test and initialization are in progress after you "hot swap" a mini-GBIC into the switch; Introducing the Switch Introducing the Switch Front of the switch has failed its...
... on /off . The 600 RPS/EPS is present but may be powering the unit - the mini-GBIC is tested when it . The switch self test and initialization are in progress after you "hot swap" a mini-GBIC into the switch; Introducing the Switch Introducing the Switch Front of the switch has failed its...
User Manual
Page 14
...LEDs will blink with a slow blink rate on /off cycle once every 1.6 seconds, approximately. 2 For the 2600-8-PWR device, both connectors of port 9, when a mini-GBIC/SFP is not receiving link beat or sufficient light • the port has been disabled through the switch console, the web browser interface, ProCurve Manager... indicates the enabled port: • if the "T" is on, the 10/100/1000Base-T RJ-45 port is enabled. • if the "M" is on, the mini-GBIC port is enabled. 1 The blinking behavior is an on the 9M port to the port • the port is fully inserted into the garage, the...
...LEDs will blink with a slow blink rate on /off cycle once every 1.6 seconds, approximately. 2 For the 2600-8-PWR device, both connectors of port 9, when a mini-GBIC/SFP is not receiving link beat or sufficient light • the port has been disabled through the switch console, the web browser interface, ProCurve Manager... indicates the enabled port: • if the "T" is on, the 10/100/1000Base-T RJ-45 port is enabled. • if the "M" is on, the mini-GBIC port is enabled. 1 The blinking behavior is an on the 9M port to the port • the port is fully inserted into the garage, the...
User Manual
Page 19
...terminal emulator, or a VT-100 terminal. There are enabled-just connect the network cables to active network devices and your switched network is operational. ■ HP Auto-MDIX on all 10/100 twisted-pair ports, and IEEE 802.3ab Auto MDI/MDI-X on the Documentation CD-ROM that is described under... the Switch" on when connected to any voltage between 100-240 volts and either the auto sensing 10/100/1000Base-T RJ-45 or the mini-GBIC can be used to connect a console to a Series 2600 Switch by using straight-through cables. The switches automatically adjust to an active AC power source...
...terminal emulator, or a VT-100 terminal. There are enabled-just connect the network cables to active network devices and your switched network is operational. ■ HP Auto-MDIX on all 10/100 twisted-pair ports, and IEEE 802.3ab Auto MDI/MDI-X on the Documentation CD-ROM that is described under... the Switch" on when connected to any voltage between 100-240 volts and either the auto sensing 10/100/1000Base-T RJ-45 or the mini-GBIC can be used to connect a console to a Series 2600 Switch by using straight-through cables. The switches automatically adjust to an active AC power source...
User Manual
Page 20
...; automatically negotiated full-duplex operation for the 10/100 and 10/100/1000 RJ-45 ports when connected to other auto-negotiating devices-the mini-GBIC ports always operate at full duplex. ■ easy management of new switch software for many advanced features to 30 IEEE 802.1Q-compliant VLANs so...
...; automatically negotiated full-duplex operation for the 10/100 and 10/100/1000 RJ-45 ports when connected to other auto-negotiating devices-the mini-GBIC ports always operate at full duplex. ■ easy management of new switch software for many advanced features to 30 IEEE 802.1Q-compliant VLANs so...
User Manual
Page 23
...switch (optional-page 2-30). Connect a 600 RPS/EPS or 610 EPS, (optional-page 2-21). Connect a console to the switch ports. 7. Mini-GBICs can be hot swapped- Connect power to modify the switch's configuration, for some installation precautions. 2. Mount the switch (page 2-11). To do so ... an IP address so it may be managed using the included console cable to connect a PC to the switch's console port. Install mini-GBICs (optional-page 2-7). Once the switch is powered on these steps. 1. Verify the switch passes self test (page 2-9). At this chapter if...
...switch (optional-page 2-30). Connect a 600 RPS/EPS or 610 EPS, (optional-page 2-21). Connect a console to the switch ports. 7. Mini-GBICs can be hot swapped- Connect power to modify the switch's configuration, for some installation precautions. 2. Mount the switch (page 2-11). To do so ... an IP address so it may be managed using the included console cable to connect a PC to the switch's console port. Install mini-GBICs (optional-page 2-7). Once the switch is powered on these steps. 1. Verify the switch passes self test (page 2-9). At this chapter if...
User Manual
Page 26
...cable, at least 7.6 cm (3 inches) for cooling. 2-6 see "Mode Conditioning Patch Cord for Gigabit-LX" on Gigabit-LH-LC mini-GBIC) The same single-mode fiber-optic cables as for • 70 kilometers Gigabit-LX. Between the transmit and receive ends of the fiber-optic... Installing the Switch Installing the Switch Installation Procedures Port Type Cable Type Length Limits Fiber Optic Cables Gigabit-SX (on Gigabit-SX-LC mini-GBIC) Multimode fiber-optic cables fitted with LC connectors. • single-mode cable = 10 kilometers • multimode cable = 550 meters The ...
...cable, at least 7.6 cm (3 inches) for cooling. 2-6 see "Mode Conditioning Patch Cord for Gigabit-LX" on Gigabit-LH-LC mini-GBIC) The same single-mode fiber-optic cables as for • 70 kilometers Gigabit-LX. Between the transmit and receive ends of the fiber-optic... Installing the Switch Installing the Switch Installation Procedures Port Type Cable Type Length Limits Fiber Optic Cables Gigabit-SX (on Gigabit-SX-LC mini-GBIC) Multimode fiber-optic cables fitted with LC connectors. • single-mode cable = 10 kilometers • multimode cable = 550 meters The ...
User Manual
Page 27
...sides and gently insert it for each Gigabit port 2-7 Installing the Switch Notes Caution WARNING Installing the Switch Installation Procedures 2. Use only ProCurve mini-GBICs. ■ The mini-GBIC slots are shared with your ProCurve Networking Sales and Service Office or authorized dealer. Half duplex operation is not supported. ■ Ensure the... the protective plastic cover and retain it into either of the slots on the switch until the mini-GBIC clicks into place. GPoigrt-sT 38 37 40 39 42 41 44 43 46 45 M 48 47 47 50 T M MGPoBinrItCis- 48 ! 49 T Use only one ...
...sides and gently insert it for each Gigabit port 2-7 Installing the Switch Notes Caution WARNING Installing the Switch Installation Procedures 2. Use only ProCurve mini-GBICs. ■ The mini-GBIC slots are shared with your ProCurve Networking Sales and Service Office or authorized dealer. Half duplex operation is not supported. ■ Ensure the... the protective plastic cover and retain it into either of the slots on the switch until the mini-GBIC clicks into place. GPoigrt-sT 38 37 40 39 42 41 44 43 46 45 M 48 47 47 50 T M MGPoBinrItCis- 48 ! 49 T Use only one ...
User Manual
Page 28
... have either of three different release mechanisms: a plastic tab on the bottom of the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail. To remove the mini-GBICs that have the plastic tab or plastic collar, push the tab or collar toward the switch until it may have the wire bail... you see it move outward slightly), and then pull it from the slot. Replace the protective plastic cover on when you can see the mini-GBIC release from the switch (you purchased your ProCurve mini-GBIC, it is approximately horizontal, and then using the bail, pull the mini...
... have either of three different release mechanisms: a plastic tab on the bottom of the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail. To remove the mini-GBICs that have the plastic tab or plastic collar, push the tab or collar toward the switch until it may have the wire bail... you see it move outward slightly), and then pull it from the slot. Replace the protective plastic cover on when you can see the mini-GBIC release from the switch (you purchased your ProCurve mini-GBIC, it is approximately horizontal, and then using the bail, pull the mini...
User Manual
Page 40
If the Link LED does not go on when the network cable is connected to any mini-GBICs you have installed in chapter 4, "Troubleshooting". hp procurve switch 2650 J4899A 12 1 Self Test Port Lnk Fan Status LED View Act FDx Spd 34 56 eset Clear Spd mode: off = 10 Mbps, ...
If the Link LED does not go on when the network cable is connected to any mini-GBICs you have installed in chapter 4, "Troubleshooting". hp procurve switch 2650 J4899A 12 1 Self Test Port Lnk Fan Status LED View Act FDx Spd 34 56 eset Clear Spd mode: off = 10 Mbps, ...
User Manual
Page 41
... the documentation that port should fail. For the Switch 2650-PWR the external PoE power is disabled. If you have any mini-GBICs installed in the switch, the type of network connections you have installed. Should the internal switch power supply fail, power will need...PoE capabilities, see "Diagnosing with the two 10/100/1000Base-T RJ-45 ports. Note Installing the Switch Installation Procedures Connecting Cables to mini-GBICs The mini-GBIC slots are shared with the LEDs" in chapter 4, "Troubleshooting". 7. (Optional) Connect a Redundant Power Supply to a Series 2600-PWR Switch...
... the documentation that port should fail. For the Switch 2650-PWR the external PoE power is disabled. If you have any mini-GBICs installed in the switch, the type of network connections you have installed. Should the internal switch power supply fail, power will need...PoE capabilities, see "Diagnosing with the two 10/100/1000Base-T RJ-45 ports. Note Installing the Switch Installation Procedures Connecting Cables to mini-GBICs The mini-GBIC slots are shared with the LEDs" in chapter 4, "Troubleshooting". 7. (Optional) Connect a Redundant Power Supply to a Series 2600-PWR Switch...
User Manual
Page 54
... all cases, the device ports must be configured to auto negotiate the link characteristics for Non-PWR Switches Because the Series 2600 Switches have the "HP Auto-MDIX" and "IEEE Auto MDI/MDI-X" features, the connections between the switch and the hubs, and between the switch and end nodes or servers... twisted-pair cable. Now, all components match in turn, can be through category 5 straight-through fiberoptic cabling connected to a Gigabit-SX, -LX, or -LH mini-GBIC. Installing the Switch Installing the Switch Sample Network Topologies for this feature to work.
... all cases, the device ports must be configured to auto negotiate the link characteristics for Non-PWR Switches Because the Series 2600 Switches have the "HP Auto-MDIX" and "IEEE Auto MDI/MDI-X" features, the connections between the switch and the hubs, and between the switch and end nodes or servers... twisted-pair cable. Now, all components match in turn, can be through category 5 straight-through fiberoptic cabling connected to a Gigabit-SX, -LX, or -LH mini-GBIC. Installing the Switch Installing the Switch Sample Network Topologies for this feature to work.
User Manual
Page 55
... your smaller switched workgroups to a campus backbone, as shown in the previous two examples can communicate with each other. For example, with Gigabit-SX Mini-GBICs installed in a Mini-GBIC Module, in the Switch 5308xl, the entire switched topology could use an ProCurve Switch 5308xl to interconnect each of a Gigabit-SX mini...
... your smaller switched workgroups to a campus backbone, as shown in the previous two examples can communicate with each other. For example, with Gigabit-SX Mini-GBICs installed in a Mini-GBIC Module, in the Switch 5308xl, the entire switched topology could use an ProCurve Switch 5308xl to interconnect each of a Gigabit-SX mini...
User Manual
Page 57
... devices, such as legacy (or non-standard) IP phones. Only devices directly connected to the PWR switches can receive PoE power if they are HP A uto-MDIX) Link 1 Mode 2 3 4 Link 5 Mode 6 7 8 Dual-Personality P ort: 10/1 00/1 000-T (T) o r Mini-GBIC (M) (P ort 9T is IEEE A uto MDI/MDIX) Link 9T Mode 9M Link Mode !
... devices, such as legacy (or non-standard) IP phones. Only devices directly connected to the PWR switches can receive PoE power if they are HP A uto-MDIX) Link 1 Mode 2 3 4 Link 5 Mode 6 7 8 Dual-Personality P ort: 10/1 00/1 000-T (T) o r Mini-GBIC (M) (P ort 9T is IEEE A uto MDI/MDIX) Link 9T Mode 9M Link Mode !
User Manual
Page 71
... LAN dealer, or use the electronic support services from is still not on . The mini-GBICs are also tested when they are snug. Call your HP-authorized LAN dealer, or use the electronic support services from the switch and wait a few moments. All assistance. See ... room temperature, but for more information. this fault condition. Contact your HP-authorized LAN dealer, or use the electronic support services from HP to operate under failed. Or try removing and reinstalling the mini-GBIC without having to the switch and check the LEDs again. Verify the ...
... LAN dealer, or use the electronic support services from is still not on . The mini-GBICs are also tested when they are snug. Call your HP-authorized LAN dealer, or use the electronic support services from the switch and wait a few moments. All assistance. See ... room temperature, but for more information. this fault condition. Contact your HP-authorized LAN dealer, or use the electronic support services from HP to operate under failed. Or try removing and reinstalling the mini-GBIC without having to the switch and check the LEDs again. Verify the ...