Configuring the HP ProLiant Server BIOS for Low-Latency Applications
Page 7
...recent version. In any case, disabling Memory Pre-Failure Notification does not disable the Advanced ECC mode or correction of the features described below are required. Select the installed OS. 3. Supported AMP modes depend on HP ProLiant G6 servers and server blades with ... frequency of the mode configured in HP ProLiant G1 through G5 server blades with Intel® Xeon® processors. Search the HP website (http://www.hp.com/go/bladesystem) for minimum latency, you can disable Processor Power and Utilization Monitoring, Memory Pre-Failure Notification, or both. ...
...recent version. In any case, disabling Memory Pre-Failure Notification does not disable the Advanced ECC mode or correction of the features described below are required. Select the installed OS. 3. Supported AMP modes depend on HP ProLiant G6 servers and server blades with ... frequency of the mode configured in HP ProLiant G1 through G5 server blades with Intel® Xeon® processors. Search the HP website (http://www.hp.com/go/bladesystem) for minimum latency, you can disable Processor Power and Utilization Monitoring, Memory Pre-Failure Notification, or both. ...
HP BladeSystem Onboard Administrator Command Line Interface User Guide Version 3.00
Page 66
CPU Zone CPU 1 CPU 1 CPU Zone CPU 2 CPU 2 Memory Zone Ambient Zone OK 34C/ 93F 65C 70C OK 52C/125F 95C 100C OK 52C/125F 95C 100C OK 33C/ 91F ...ALL Current PowerDelay Status: Not in Progress Bay Device PowerDelay State Delay (seconds) 1 ProLiant BL480c G1 Disabled 0 1A Absent Disabled 0 1B Absent Disabled 0 2 ProLiant BL480c G1 Disabled 0 2A Absent Disabled 0 2B Absent Disabled 0 3 Absent Disabled 0 3A Absent Disabled 0 3B Absent Disabled 0 4 ProLiant BL460c G1 Disabled 0 4A Absent Disabled 0 4B Absent Disabled 0 5 Subsumed Disabled 0 5A...
CPU Zone CPU 1 CPU 1 CPU Zone CPU 2 CPU 2 Memory Zone Ambient Zone OK 34C/ 93F 65C 70C OK 52C/125F 95C 100C OK 52C/125F 95C 100C OK 33C/ 91F ...ALL Current PowerDelay Status: Not in Progress Bay Device PowerDelay State Delay (seconds) 1 ProLiant BL480c G1 Disabled 0 1A Absent Disabled 0 1B Absent Disabled 0 2 ProLiant BL480c G1 Disabled 0 2A Absent Disabled 0 2B Absent Disabled 0 3 Absent Disabled 0 3A Absent Disabled 0 3B Absent Disabled 0 4 ProLiant BL460c G1 Disabled 0 4A Absent Disabled 0 4B Absent Disabled 0 5 Subsumed Disabled 0 5A...
HP BladeSystem Onboard Administrator Command Line Interface User Guide Version 3.00
Page 131
...Displays the following fields: o Type o Name o Part number o Serial number o Asset tag o BIOS version o All CPU types and associated maximum speeds o Memory o NIC #1 MAC o NIC #2 MAC o iLO name, iLO IP address, and iLO firmware version o Power Management Controller version o VLAN ID • ...to the specified bay number. Example OA-0018FE27577F> show server info 1 Server Blade #1 Information: Type: Server Blade Manufacturer: HP Product Name: ProLiant BL480c G1 Part Number: 416667-B21 System Board Spare Part Number: 410293-001 Serial Number: USM64204B1 UUID: 36363134-3736-5355-4D36-343230344231...
...Displays the following fields: o Type o Name o Part number o Serial number o Asset tag o BIOS version o All CPU types and associated maximum speeds o Memory o NIC #1 MAC o NIC #2 MAC o iLO name, iLO IP address, and iLO firmware version o Power Management Controller version o VLAN ID • ...to the specified bay number. Example OA-0018FE27577F> show server info 1 Server Blade #1 Information: Type: Server Blade Manufacturer: HP Product Name: ProLiant BL480c G1 Part Number: 416667-B21 System Board Spare Part Number: 410293-001 Serial Number: USM64204B1 UUID: 36363134-3736-5355-4D36-343230344231...