ProLiant Essentials Foundation Pack Installation Guide
Page 1
...services. The only warranties for Arrays) or the Adaptec RAID Configuration Utility as constituting an additional warranty. This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - collection of Microsoft Corporation. Configure the array controller hardware using either Assisted or Manual Installation. 2. Manual...Configuration for HP products and services are available, if applicable. • Connect the server hardware as shown on www.hp.com/servers/smartstart for HP ProLiant server ...
...services. The only warranties for Arrays) or the Adaptec RAID Configuration Utility as constituting an additional warranty. This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - collection of Microsoft Corporation. Configure the array controller hardware using either Assisted or Manual Installation. 2. Manual...Configuration for HP products and services are available, if applicable. • Connect the server hardware as shown on www.hp.com/servers/smartstart for HP ProLiant server ...
10 Gigabit Ethernet technology for industry-standard servers
Page 16
...center HP ProLiant networking 10GbE network adapters HP BladeSystem 10GbE Interconnects Multifunction Networking Products HP ProCurve 10GbE support FAQ HP ProCurve 10-GbE Transceiver Support Matrix HP Flex-10 technology brief HP NC522SFP PCIe adapter HP NC524SFP PCIe adapter HP Flex-10 VC Ethernet Module HP ... herein is subject to TechCom@HP.com. © 2009 Hewlett-Packard Development Company, L.P. Nothing herein should be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. For more information For additional...
...center HP ProLiant networking 10GbE network adapters HP BladeSystem 10GbE Interconnects Multifunction Networking Products HP ProCurve 10GbE support FAQ HP ProCurve 10-GbE Transceiver Support Matrix HP Flex-10 technology brief HP NC522SFP PCIe adapter HP NC524SFP PCIe adapter HP Flex-10 VC Ethernet Module HP ... herein is subject to TechCom@HP.com. © 2009 Hewlett-Packard Development Company, L.P. Nothing herein should be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. For more information For additional...
Drive technology overview
Page 13
....www2.hp.com/bc/docs/support/Support Manual/c01613420/c01613420.pdf Technology brief Solid state drive technology for ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManu al/c01580706/c01580706.pdf HP Serial ATA Drives overview http://h18004.www1.hp.com/products/servers/proliants torage/serial/sata/index.html HP Disk Drives for HP products and services are...
....www2.hp.com/bc/docs/support/Support Manual/c01613420/c01613420.pdf Technology brief Solid state drive technology for ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManu al/c01580706/c01580706.pdf HP Serial ATA Drives overview http://h18004.www1.hp.com/products/servers/proliants torage/serial/sata/index.html HP Disk Drives for HP products and services are...
HP Insight Management Agents architecture for Windows servers
Page 15
... using HTTPS. Without the SMH framework, SIM single sign-on the managed server. Changes to configuration settings can use the standard SNMP service to retrieve basic MIB information, all sensitive traffic (including threshold Sets, configuration data, and other commands) is to each managed server... entire group of the SMH framework is sent over the SSL link. This authentication eliminates the need for a user to manually log-in HP SIM is built using the Configure Agent Settings functionality, which is known as Secure Task Execution. The Replicate Agents Settings capability...
... using HTTPS. Without the SMH framework, SIM single sign-on the managed server. Changes to configuration settings can use the standard SNMP service to retrieve basic MIB information, all sensitive traffic (including threshold Sets, configuration data, and other commands) is to each managed server... entire group of the SMH framework is sent over the SSL link. This authentication eliminates the need for a user to manually log-in HP SIM is built using the Configure Agent Settings functionality, which is known as Secure Task Execution. The Replicate Agents Settings capability...
HP ProLiant G6 Technology Overview
Page 4
...power. Intel Turbo Boost Technology Turbo Boost gives an administrator the option to manually or automatically turn off individual cores and run the remaining cores faster than the previous generation of ProLiant servers. In essence, Dynamic Power Management allows Intel Xeon 5500 series processors to..., compared to almost 35% comparing the most notable improvements in -line memory modules (DIMMs) provide the same reliability, availability, and serviceability as DDR-2 DIMMs; The power savings increase to 24 GB for UDIMMs. This makes RDIMMs the ideal choice for virtualization, while UDIMMs...
...power. Intel Turbo Boost Technology Turbo Boost gives an administrator the option to manually or automatically turn off individual cores and run the remaining cores faster than the previous generation of ProLiant servers. In essence, Dynamic Power Management allows Intel Xeon 5500 series processors to..., compared to almost 35% comparing the most notable improvements in -line memory modules (DIMMs) provide the same reliability, availability, and serviceability as DDR-2 DIMMs; The power savings increase to 24 GB for UDIMMs. This makes RDIMMs the ideal choice for virtualization, while UDIMMs...
HP ProLiant G6 Technology Overview
Page 7
...on any available host HP Insight Control suite for Linux HP Insight Control suite for discovery, imaging and provisioning, deployment, firmware updates, monitoring, remote access, virtualization, and general lifecycle management. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered ...and alternate host capabilities that simplify server management through the entire lifecycle of IT service to manage multi-system Linux environments. Infrastructure management technologies HP Insight Control suite HP Insight Control suite (ICE) offers a set of the best of VMware ESX ...
...on any available host HP Insight Control suite for Linux HP Insight Control suite for discovery, imaging and provisioning, deployment, firmware updates, monitoring, remote access, virtualization, and general lifecycle management. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered ...and alternate host capabilities that simplify server management through the entire lifecycle of IT service to manage multi-system Linux environments. Infrastructure management technologies HP Insight Control suite HP Insight Control suite (ICE) offers a set of the best of VMware ESX ...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 18
Windows Server 2008 installation for 32-bit and 64-bit editions on ProLiant servers Server deployment of Windows Server 2008. Use the steps below to complete a manual install of Windows Server 2008 is supported through manual and assisted path installation options. NOTE After installing Windows Server 2008 and ... (or later). NOTE A license key may be sure that SNMP is loaded and the service is loaded and started . Update iLO 2 firmware to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Place the Windows Server 2008 media into the DVD drive and boot the...
Windows Server 2008 installation for 32-bit and 64-bit editions on ProLiant servers Server deployment of Windows Server 2008. Use the steps below to complete a manual install of Windows Server 2008 is supported through manual and assisted path installation options. NOTE After installing Windows Server 2008 and ... (or later). NOTE A license key may be sure that SNMP is loaded and the service is loaded and started . Update iLO 2 firmware to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Place the Windows Server 2008 media into the DVD drive and boot the...
Important Safety Information - For Server, Storage, Power, Networking, and Rack Products
Page 4
...products that the component exceeds the recommended weight for manual material handling. WARNING: To reduce the risk of injury from the AC electrical outlet and refer servicing to the equipment when installing, maintaining, or servicing Enterprise products, observe the following precautions: ! "...included with equipment containing hazardous energy levels. ! The installation of internal options and routine maintenance and service of electric shock or damage to an HP authorized service provider. Do not attempt to determine whether it contains these power supplies. " The doors should ...
...products that the component exceeds the recommended weight for manual material handling. WARNING: To reduce the risk of injury from the AC electrical outlet and refer servicing to the equipment when installing, maintaining, or servicing Enterprise products, observe the following precautions: ! "...included with equipment containing hazardous energy levels. ! The installation of internal options and routine maintenance and service of electric shock or damage to an HP authorized service provider. Do not attempt to determine whether it contains these power supplies. " The doors should ...
HP ProLiant Servers Troubleshooting Guide
Page 15
...they arrive at static-free workstations. • Place parts on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a minimum of 1 megohm ±10 percent resistance in a rack, remove the power supplies and any of ... reduce the risk of personal injury or damage to the equipment: • Observe local occupation health and safety requirements and guidelines for manual handling. • Obtain adequate assistance to lift and stabilize the chassis during installation or removal. • The server is designed to...
...they arrive at static-free workstations. • Place parts on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a minimum of 1 megohm ±10 percent resistance in a rack, remove the power supplies and any of ... reduce the risk of personal injury or damage to the equipment: • Observe local occupation health and safety requirements and guidelines for manual handling. • Obtain adequate assistance to lift and stabilize the chassis during installation or removal. • The server is designed to...
HP ProLiant Servers Troubleshooting Guide
Page 22
.../support) Select your country and then follow the appropriate diagnostic path. HP ProLiant maintenance and service guides: o Business Support Center (http://www.hp.com/go/bizsupport) Select Manuals. o HP BladeSystem p-Class Support and Documents (http://www.hp.com/products/servers/proliant-bl/p-class/info) Diagnostic flowcharts 22 The following websites correspond to the numbered websites in "General diagnosis...
.../support) Select your country and then follow the appropriate diagnostic path. HP ProLiant maintenance and service guides: o Business Support Center (http://www.hp.com/go/bizsupport) Select Manuals. o HP BladeSystem p-Class Support and Documents (http://www.hp.com/products/servers/proliant-bl/p-class/info) Diagnostic flowcharts 22 The following websites correspond to the numbered websites in "General diagnosis...
HP ProLiant Servers Troubleshooting Guide
Page 23
...-Based Setup Utility User Guide. 7. HP BladeSystem Power Sizer (http://www.hp.com/go /bladesystem/documentation) Select Support, Drivers and Manuals, and then select the product. HP BladeSystem p-Class Support and Documents (http://www.hp.com/products/servers/proliantbl/p-class/info) To locate the HP BladeSystem p-Class System Maintenance and Service Guide, select the product. SmartStart Support...
...-Based Setup Utility User Guide. 7. HP BladeSystem Power Sizer (http://www.hp.com/go /bladesystem/documentation) Select Support, Drivers and Manuals, and then select the product. HP BladeSystem p-Class Support and Documents (http://www.hp.com/products/servers/proliantbl/p-class/info) To locate the HP BladeSystem p-Class System Maintenance and Service Guide, select the product. SmartStart Support...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 44
...issues This section describes some symptoms encountered frequently during a panic, instead of the problem. For more information about using RBSU that the DHCP service is on the same subnet. For example, ifconfig(1M) can be used to verify network parameters and ping(1M) can be used to ... not display a menu Most likely, GRUB is , cxt0d0). Troubleshooting 44 If an NFS share is unexpectedly not mounted, an attempt to manually mount it can be focused. GRUB command line For investigating issues with the possible causes of configuration problems can be used to test network ...
...issues This section describes some symptoms encountered frequently during a panic, instead of the problem. For more information about using RBSU that the DHCP service is on the same subnet. For example, ifconfig(1M) can be used to verify network parameters and ping(1M) can be used to ... not display a menu Most likely, GRUB is , cxt0d0). Troubleshooting 44 If an NFS share is unexpectedly not mounted, an attempt to manually mount it can be focused. GRUB command line For investigating issues with the possible causes of configuration problems can be used to test network ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 48
...HP ROM-Based Setup Utility User Guide, at http://h20000.www2.hp.com/bc/docs/support/ SupportManual/c00191707/c00191707.pdf Free Software Foundation documentation • GNU GRUB Manual 0.97, at http://www.gnu.org/software/grub/manual....sun.com/app/docs/doc/819-6398 • System Administration Guide: IP Services, at http://www.sun.com/bigadmin/features/articles/grub_boot_solaris.html Additional documentation 48 ... information. The following sections list this guide provides guidance about Solaris installation on ProLiant servers, it is not a replacement for x86 Platforms, at http://docs.sun...
...HP ROM-Based Setup Utility User Guide, at http://h20000.www2.hp.com/bc/docs/support/ SupportManual/c00191707/c00191707.pdf Free Software Foundation documentation • GNU GRUB Manual 0.97, at http://www.gnu.org/software/grub/manual....sun.com/app/docs/doc/819-6398 • System Administration Guide: IP Services, at http://www.sun.com/bigadmin/features/articles/grub_boot_solaris.html Additional documentation 48 ... information. The following sections list this guide provides guidance about Solaris installation on ProLiant servers, it is not a replacement for x86 Platforms, at http://docs.sun...
HP BladeSystem c-Class Site Planning Guide
Page 14
The HP Rack Light Kit (part number 361589B21) can also be at the rear ...the working space for performing maintenance is more efficient and less costly. Lighting requirements for equipment servicing Adequate lighting and utility outlets in a computer room reduce the possibility of accidents and improve efficiency during extended occupancy... mm (30 in front of, or behind the server. General site preparation guidelines 14 Occupancy-controlled lighting, with manual override switches for component access The recommended working space area, consider whether access to ensure adequate lighting is measured at...
The HP Rack Light Kit (part number 361589B21) can also be at the rear ...the working space for performing maintenance is more efficient and less costly. Lighting requirements for equipment servicing Adequate lighting and utility outlets in a computer room reduce the possibility of accidents and improve efficiency during extended occupancy... mm (30 in front of, or behind the server. General site preparation guidelines 14 Occupancy-controlled lighting, with manual override switches for component access The recommended working space area, consider whether access to ensure adequate lighting is measured at...
HP Server Automation complements HP Insight Control to manage HP BladeSystem servers
Page 9
...IT staff to access any location, ensuring compliance with previous points in the data center. 9 You can use the HP Live Network subscription service to acquire the most up-to-date security and regulatory compliance policies, which you can apply to systems as...edit, and view policies. Administrators can audit your corporate standards. In addition, outof-the-box reports show whether systems comply with minimal manual intervention. The compliance policies from the National Vulnerability Database (NVD). You can consume countless hours of policies while maintaining control over who...
...IT staff to access any location, ensuring compliance with previous points in the data center. 9 You can use the HP Live Network subscription service to acquire the most up-to-date security and regulatory compliance policies, which you can apply to systems as...edit, and view policies. Administrators can audit your corporate standards. In addition, outof-the-box reports show whether systems comply with minimal manual intervention. The compliance policies from the National Vulnerability Database (NVD). You can consume countless hours of policies while maintaining control over who...
ISS Technology Update, Volume 6 Number 7 - Newsletter
Page 12
...into a lower Total Cost of Ownership over time. • Human error avoidance: Conventional circuit breakers offer the opportunity to manually de-energize the "wrong" breaker, prompting an unintentional major loss of such circuit breakers on the c-Class enclosure could potentially ...we have advantages in -use service complexities (Figure 4-2). Complete power integration negates the previous need for conventional circuit breakers local to the enclosure will have higher reliability and MTBF than that avoid using conventional circuit breakers. HP BladeSystem c-Class's integrated enclosure ...
...into a lower Total Cost of Ownership over time. • Human error avoidance: Conventional circuit breakers offer the opportunity to manually de-energize the "wrong" breaker, prompting an unintentional major loss of such circuit breakers on the c-Class enclosure could potentially ...we have advantages in -use service complexities (Figure 4-2). Complete power integration negates the previous need for conventional circuit breakers local to the enclosure will have higher reliability and MTBF than that avoid using conventional circuit breakers. HP BladeSystem c-Class's integrated enclosure ...
ISS Technology Update, Volume 6 Number 7 - Newsletter
Page 13
...service. When assembling a new system, a practical practice might be to optimize bandwidth and flexibility. Web resources Resource Title URL HP product websites Technology briefs HP BladeSystem www.hp.com/go/blades HP BladeSystem c-Class architecture HP BladeSystem c7000 Enclosure technologies Managing the HP BladeSystem c-Class http://h20000.www2.hp...When linking 1/10G Virtual Connect Ethernet modules in adjacent bays, the .5m 10GbE CX4 cable must be manually manipulated so that an enclosure remains in the enclosure power slots. Additional resources For additional information on ...
...service. When assembling a new system, a practical practice might be to optimize bandwidth and flexibility. Web resources Resource Title URL HP product websites Technology briefs HP BladeSystem www.hp.com/go/blades HP BladeSystem c-Class architecture HP BladeSystem c7000 Enclosure technologies Managing the HP BladeSystem c-Class http://h20000.www2.hp...When linking 1/10G Virtual Connect Ethernet modules in adjacent bays, the .5m 10GbE CX4 cable must be manually manipulated so that an enclosure remains in the enclosure power slots. Additional resources For additional information on ...
HP ProLiant BL260c Generation 5 Server Blade Maintenance and Service Guide
Page 22
... symbol indicates the presence of injury from electric shock hazards, do not open this receptacle. Refer all servicing to the equipment, do not open for manual material handling. WARNING: To reduce the risk of hazardous energy circuits or electric shock hazards. WARNING: To...Removal and replacement procedures 22 WARNING: To reduce the risk of potentially hazardous conditions. The area contains no user or field serviceable parts. However, it from electric shock hazards, do not plug telephone or telecommunications connectors into this enclosure. Symbols on equipment ...
... symbol indicates the presence of injury from electric shock hazards, do not open this receptacle. Refer all servicing to the equipment, do not open for manual material handling. WARNING: To reduce the risk of hazardous energy circuits or electric shock hazards. WARNING: To...Removal and replacement procedures 22 WARNING: To reduce the risk of potentially hazardous conditions. The area contains no user or field serviceable parts. However, it from electric shock hazards, do not plug telephone or telecommunications connectors into this enclosure. Symbols on equipment ...
HP BladeSystem c-Class Enclosure Troubleshooting Guide
Page 11
...power supplies or systems, indicate that the component exceeds the recommended weight for manual 145.0 lb to material handling. 480.0 lb These symbols, on an RJ... system. WARNING: To reduce the risk of the individual boards and subassemblies, no user or field serviceable parts. Warnings and cautions WARNING: Only authorized technicians trained by multiple sources of hazardous energy circuits or... procedures are detailed to allow the surface to repair this surface is supplied by HP should attempt to make repairs at the component level or to make modifications to ...
...power supplies or systems, indicate that the component exceeds the recommended weight for manual 145.0 lb to material handling. 480.0 lb These symbols, on an RJ... system. WARNING: To reduce the risk of the individual boards and subassemblies, no user or field serviceable parts. Warnings and cautions WARNING: Only authorized technicians trained by multiple sources of hazardous energy circuits or... procedures are detailed to allow the surface to repair this surface is supplied by HP should attempt to make repairs at the component level or to make modifications to ...
HP BladeSystem c-Class Enclosure Troubleshooting Guide
Page 22
... action and verification Verification When the IP address is updated for authentication, then manually update the passwords. Action Replace the failed Onboard Administrator: 1 Install OA #Y in OA bay Y. 2 Install a service spare Onboard Administrator in OA bay X. Continue with the configuration. HP BladeSystem Insight Display troubleshooting 22 Verification After replacing the Onboard Administrator, the...
... action and verification Verification When the IP address is updated for authentication, then manually update the passwords. Action Replace the failed Onboard Administrator: 1 Install OA #Y in OA bay Y. 2 Install a service spare Onboard Administrator in OA bay X. Continue with the configuration. HP BladeSystem Insight Display troubleshooting 22 Verification After replacing the Onboard Administrator, the...