Converting Your Rack Server to a Pedestal Server
Page 1
...32, Torx 15 screws · This data sheet Remove the Server from the Rack Enclosure To remove a rack server from its side on the frame assembly just installed. 4. v2 Printed in the document Installation Guide for Midweight Slide Kit (HP Part Number: 5064-9640) that it rests on a flat... surface. Insert the two center tubes into the sockets on its rack enclosure. · Remove any slide rail mounting attachments. · Install the server's pedestal. Assemble the Pedestal Frame to the server using three 6-32...
...32, Torx 15 screws · This data sheet Remove the Server from the Rack Enclosure To remove a rack server from its side on the frame assembly just installed. 4. v2 Printed in the document Installation Guide for Midweight Slide Kit (HP Part Number: 5064-9640) that it rests on a flat... surface. Insert the two center tubes into the sockets on its rack enclosure. · Remove any slide rail mounting attachments. · Install the server's pedestal. Assemble the Pedestal Frame to the server using three 6-32...
Converting Your Rack Server to a Pedestal Server
Page 2
Figure 1. Assembling the Pedestal Frame to power on the server detailed in the Installation Guide provided with your server. 2 of the steps required to the Server Frame Assembly Center Tubes Frame Assembly 6. Complete the rack to pedestal conversion by performing all of 2
Figure 1. Assembling the Pedestal Frame to power on the server detailed in the Installation Guide provided with your server. 2 of the steps required to the Server Frame Assembly Center Tubes Frame Assembly 6. Complete the rack to pedestal conversion by performing all of 2
Errata: Important Information about your HP Server - hp 9000 rp4440
Page 1
... for the hp 9000 rp4440 Server erroneously report the availability of server documentation and User Guides for the hp 9000 rp4440 Server can be found at this kit is not supported at http:// docs.hp.com: Shutdown after a fan failure or removal. Server operation continues normally. The correct HP P/N for this time. hp 9000 rp4440 Errata: Important Information about your HP Server Important Notes...
... for the hp 9000 rp4440 Server erroneously report the availability of server documentation and User Guides for the hp 9000 rp4440 Server can be found at this kit is not supported at http:// docs.hp.com: Shutdown after a fan failure or removal. Server operation continues normally. The correct HP P/N for this time. hp 9000 rp4440 Errata: Important Information about your HP Server Important Notes...
Read Me First, Second Edition: Before Removing or Replacing PCI/PCI-X Cards
Page 1
... add, remove, or replace a PCI/PCI-X card, read the complete instructions in the U.S.A. HP-UX Update Patches Hewlett Packard PA-8800 based servers and workstations require the December 2003 (or later) release of noncritical LPMC errors and other events.... • PHKL_30105 11.11 remove mem module and LPMC syslog msgs -Remove noncritical messages from server on different subnet. • PHKL_30100 11.11 Psets, vPar, Xserver, T600 HPMC, KRNG, early LPMC -Corrects LPMC ... LAN swinstall from dmesg buffer and syslog. v2 Printed in your hp 9000 rp4440 server.
... add, remove, or replace a PCI/PCI-X card, read the complete instructions in the U.S.A. HP-UX Update Patches Hewlett Packard PA-8800 based servers and workstations require the December 2003 (or later) release of noncritical LPMC errors and other events.... • PHKL_30105 11.11 remove mem module and LPMC syslog msgs -Remove noncritical messages from server on different subnet. • PHKL_30100 11.11 Psets, vPar, Xserver, T600 HPMC, KRNG, early LPMC -Corrects LPMC ... LAN swinstall from dmesg buffer and syslog. v2 Printed in your hp 9000 rp4440 server.
Read Me First, Second Edition: Before Removing or Replacing PCI/PCI-X Cards
Page 2
... drivers. This includes all documentation that might be in your HP Server documentation. See Table for part number identification. Initiate OLAR operation on HP-UX patches, check the HP IT Resource Center at http://itrc.hp.com. Table 1 1GHz CPU Part Numbers Product Part Number ... Replacement Example: Suspend drivers, turn off power to initiating an OLAR operation on a different slot. Your hp 9000 rp4440 Does Not Use 900MHz Processors Your hp 9000 rp4440 Server does not use 900MHz processors. Multiple, concurrent OLAR operations may result in CD format. Please disregard any ...
... drivers. This includes all documentation that might be in your HP Server documentation. See Table for part number identification. Initiate OLAR operation on HP-UX patches, check the HP IT Resource Center at http://itrc.hp.com. Table 1 1GHz CPU Part Numbers Product Part Number ... Replacement Example: Suspend drivers, turn off power to initiating an OLAR operation on a different slot. Your hp 9000 rp4440 Does Not Use 900MHz Processors Your hp 9000 rp4440 Server does not use 900MHz processors. Multiple, concurrent OLAR operations may result in CD format. Please disregard any ...
Read Me First: Before Installing Your A6150B Graphics Card
Page 1
... activate graphics capability. USB capability is NOT supported. HP Server Documentation For complete instructions on installing PCI cards into your HP Server. it is already incorporated into a hp 9000 rp4440 Server, you need only install the graphics card to : http://docs.hp.com v1 Printed in the U.S.A. READ ME FIRST ...Graphics Card If you ordered this A6150B graphics card kit for installation into your hp 9000 rp4440 Server and the USB ports are located on the Documentation CD that was included with your HP Server, see the Operation and Maintenance Guide on the rear panel. DO NOT ...
... activate graphics capability. USB capability is NOT supported. HP Server Documentation For complete instructions on installing PCI cards into your HP Server. it is already incorporated into a hp 9000 rp4440 Server, you need only install the graphics card to : http://docs.hp.com v1 Printed in the U.S.A. READ ME FIRST ...Graphics Card If you ordered this A6150B graphics card kit for installation into your hp 9000 rp4440 Server and the USB ports are located on the Documentation CD that was included with your HP Server, see the Operation and Maintenance Guide on the rear panel. DO NOT ...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 5
Airflow Through HP 9000 rp4410 and HP 9000 rp4440 Server 20 Figure 2-1. Raised Floor Metal Strip Ground System 28 Figure 2-2. Delivery Survey (Part 1 46 Figure 2-3. Delivery Survey (Part 2 47 5 HP 9000 rp4410 and HP 9000 rp4440 Server 11 Figure 1-2. Figures Figure 1-1.
Airflow Through HP 9000 rp4410 and HP 9000 rp4440 Server 20 Figure 2-1. Raised Floor Metal Strip Ground System 28 Figure 2-2. Delivery Survey (Part 1 46 Figure 2-3. Delivery Survey (Part 2 47 5 HP 9000 rp4410 and HP 9000 rp4440 Server 11 Figure 1-2. Figures Figure 1-1.
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 8
... System Information You can find information about administration of the Microsoft® Windows® operating system at the http://docs.hp.com/hpux/diag/ Web site. Server Hardware Information: http://docs.hp.com/hpux/hw/ The http://docs.hp.com/hpux/hw/ Web site is at the following publications. Please address your feedback on...
... System Information You can find information about administration of the Microsoft® Windows® operating system at the http://docs.hp.com/hpux/diag/ Web site. Server Hardware Information: http://docs.hp.com/hpux/hw/ The http://docs.hp.com/hpux/hw/ Web site is at the following publications. Please address your feedback on...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 11
A single CPU or all installed CPUs are available with 32 MB or 64 MB L2 cache. Table 1-1 Minimum/Maximum Configuration Component Microprocessors rp4410 rp4440 One or two dual processor modules, each containing two PA RISC 800 MHz/1.5 MB cache or 1 GHz/1.5 MB cache. The CPUs... (2, 4, 6, or 8) are available with 32 MB or 64 MB L2 cache. The CPUs are activated Chapter 1 11 1 System Specifications System Configuration Figure 1-1 HP 9000 rp4410 and HP 9000 rp4440 Server The following table describes the component options for the HP 9000 rp4410 and HP 9000 rp4440 servers.
A single CPU or all installed CPUs are available with 32 MB or 64 MB L2 cache. Table 1-1 Minimum/Maximum Configuration Component Microprocessors rp4410 rp4440 One or two dual processor modules, each containing two PA RISC 800 MHz/1.5 MB cache or 1 GHz/1.5 MB cache. The CPUs... (2, 4, 6, or 8) are available with 32 MB or 64 MB L2 cache. The CPUs are activated Chapter 1 11 1 System Specifications System Configuration Figure 1-1 HP 9000 rp4410 and HP 9000 rp4440 Server The following table describes the component options for the HP 9000 rp4410 and HP 9000 rp4440 servers.
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 13
... Table 1-2 Server Component Dimensions Dimension Height-inches (centimeters) Rack configuration Stand-mounted Width-inches (centimeters) Rack configuration Stand-mounted Depth-inches (centimeters) Rack configuration Stand-mounted Weight-pounds (kilograms) Rack configuration rp4410 minimum configuration rp4410 maximum configuration Stand-mounted rp4410 minimum configuration rp4410 maximum configuration Rack...4U Chapter 1 13 System Specifications Dimensions and Weights Dimensions and Weights This section provides dimensions and weights of HP 9000 rp4410 and HP 9000 rp4440 servers.
... Table 1-2 Server Component Dimensions Dimension Height-inches (centimeters) Rack configuration Stand-mounted Width-inches (centimeters) Rack configuration Stand-mounted Depth-inches (centimeters) Rack configuration Stand-mounted Weight-pounds (kilograms) Rack configuration rp4410 minimum configuration rp4410 maximum configuration Stand-mounted rp4410 minimum configuration rp4410 maximum configuration Rack...4U Chapter 1 13 System Specifications Dimensions and Weights Dimensions and Weights This section provides dimensions and weights of HP 9000 rp4410 and HP 9000 rp4440 servers.
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 15
... cord Country S. America Circuit Breaker The marked electrical for North America. The recommended circuit breaker size is 12 amps per line cord (2 maximum) for the HP server is eight amps. For countries outside North America, consult the local electrical authority that has jurisdiction for your system. Africa UK & HK & Singapore Australia Europe... provides electrical specifications for the recommended circuit breaker size. Chapter 1 15 AC Power Cords Table 1-3 lists the various power cables available for use with the HP 9000 rp4410 and HP 9000 rp4440 servers.
... cord Country S. America Circuit Breaker The marked electrical for North America. The recommended circuit breaker size is 12 amps per line cord (2 maximum) for the HP server is eight amps. For countries outside North America, consult the local electrical authority that has jurisdiction for your system. Africa UK & HK & Singapore Australia Europe... provides electrical specifications for the recommended circuit breaker size. Chapter 1 15 AC Power Cords Table 1-3 lists the various power cables available for use with the HP 9000 rp4410 and HP 9000 rp4440 servers.
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 16
... carry through time at minimum line voltage Power factor correction Ground leakage current 200 - 240 VAC 180 VAC 264 VAC 50 - 60 Hz Value 1 8 A RMS rp4410: 100A (peak), 55A (average) 0 msec - 1 msec 55A (peak), 33A (average) 1 msec - 2 msec 5A (peak), 22A (average) 2 msec - 10 sec 25A...all loads of 90% - 100% of supply rating >0.75 at all loads of 50% - 90% of AC power needed for the server. Table 1-4 System Power Specifications Specification Nominal input voltage Minimum operating voltage Maximum operating voltage Frequency range (minimum - The following tables provide information to...
... carry through time at minimum line voltage Power factor correction Ground leakage current 200 - 240 VAC 180 VAC 264 VAC 50 - 60 Hz Value 1 8 A RMS rp4410: 100A (peak), 55A (average) 0 msec - 1 msec 55A (peak), 33A (average) 1 msec - 2 msec 5A (peak), 22A (average) 2 msec - 10 sec 25A...all loads of 90% - 100% of supply rating >0.75 at all loads of 50% - 90% of AC power needed for the server. Table 1-4 System Power Specifications Specification Nominal input voltage Minimum operating voltage Maximum operating voltage Frequency range (minimum - The following tables provide information to...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 17
... and cooling values are generally lower than maximum power numbers because all the subsystems in your HP server rarely draw maximum power simultaneously and for the configurations shown. The table lists power and cooling values associated with... for your computer room. System Specifications Electrical Specifications Table 1-5 list maximum and typical power requirements for HP 9000 rp4410 and HP 9000 rp4440 servers are listed in your HP 9000 rp4410 or HP 9000 rp4440 server. Power and Cooling Typical power consumption and cooling values for the HP 9000 rp4410 and HP 9000 rp4440 servers.
... and cooling values are generally lower than maximum power numbers because all the subsystems in your HP server rarely draw maximum power simultaneously and for the configurations shown. The table lists power and cooling values associated with... for your computer room. System Specifications Electrical Specifications Table 1-5 list maximum and typical power requirements for HP 9000 rp4410 and HP 9000 rp4440 servers are listed in your HP 9000 rp4410 or HP 9000 rp4440 server. Power and Cooling Typical power consumption and cooling values for the HP 9000 rp4410 and HP 9000 rp4440 servers.
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 19
...system overtemp shutdown. Operating Environment The system is driven by smart fan control circuits that monitor input air temperature and server operating temperatures. Data from the sensor is often different from ambient room temperature; The fan status LED is designed...through the processor and memory section, and push air through the HDD backplane. Bulk Power Supply Cooling Cooling for the HP server. System Specifications Environmental Specifications Environmental Specifications This section provides the temperature and humidity requirements, noise emission, and air flow ...
...system overtemp shutdown. Operating Environment The system is driven by smart fan control circuits that monitor input air temperature and server operating temperatures. Data from the sensor is often different from ambient room temperature; The fan status LED is designed...through the processor and memory section, and push air through the HDD backplane. Bulk Power Supply Cooling Cooling for the HP server. System Specifications Environmental Specifications Environmental Specifications This section provides the temperature and humidity requirements, noise emission, and air flow ...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 20
... the processor and memory extender boards and into the cell airflow plenum. The fans are not blocked or covered after installation. Figure 1-2 Airflow Through HP 9000 rp4410 and HP 9000 rp4440 Server 20 Chapter 1 System Specifications Environmental Specifications Air flows out of the rear of the chassis with minimal leakage into the PCI section. NOTE A power...
... the processor and memory extender boards and into the cell airflow plenum. The fans are not blocked or covered after installation. Figure 1-2 Airflow Through HP 9000 rp4410 and HP 9000 rp4440 Server 20 Chapter 1 System Specifications Environmental Specifications Air flows out of the rear of the chassis with minimal leakage into the PCI section. NOTE A power...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 21
System Specifications Environmental Specifications Acoustic Noise Specification The acoustic noise specification for the HP 9000 rp4410 or HP 9000 rp4440 servers is as follows: • 53 db LpA (sound pressure level at bystander position in a dedicated computer room environment temperature of
System Specifications Environmental Specifications Acoustic Noise Specification The acoustic noise specification for the HP 9000 rp4410 or HP 9000 rp4440 servers is as follows: • 53 db LpA (sound pressure level at bystander position in a dedicated computer room environment temperature of
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 23
... system design and installation must have a thorough knowledge and understanding of appropriate electrical codes and the limitations of an HP 9000 rp4410 or HP 9000 rp4440 server. Those responsible for this section are: • Computer room safety • Power consumption • Electrical load ... room, fire protection and adequate lighting (for equipment servicing) are based on safety monitoring equipment for an HP 9000 rp4410 or HP 9000 rp4440 server requires specialized skills. A good design, when coupled with yellow stripes. However, electrical factors relating to region...
... system design and installation must have a thorough knowledge and understanding of appropriate electrical codes and the limitations of an HP 9000 rp4410 or HP 9000 rp4440 server. Those responsible for this section are: • Computer room safety • Power consumption • Electrical load ... room, fire protection and adequate lighting (for equipment servicing) are based on safety monitoring equipment for an HP 9000 rp4410 or HP 9000 rp4440 server requires specialized skills. A good design, when coupled with yellow stripes. However, electrical factors relating to region...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 24
... location, such as a later update. The work space shall permit at the front, side, or rear of their RMS current ratings Power Quality The HP 9000 rp4410 and HP 9000 rp4440 servers are exceeded. Refer to the applicable documentation for Equipment Servicing Adequate lighting and utility outlets in a computer room reduce the possibility of accidents during...
... location, such as a later update. The work space shall permit at the front, side, or rear of their RMS current ratings Power Quality The HP 9000 rp4410 and HP 9000 rp4440 servers are exceeded. Refer to the applicable documentation for Equipment Servicing Adequate lighting and utility outlets in a computer room reduce the possibility of accidents during...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 25
...)-Keeps input voltage to work loose, overheat, and fail. Common sources of this difference, aluminum conductors can protect the HP 9000 rp4410 and HP 9000 rp4440 servers from other metals used in the facility • Missing-phase and low-voltage detectors-Shuts equipment down automatically when a .... However, testing cannot conclusively rule out loss of aluminum; Refer to qualified contractors or consultants for HP computer equipment: • Dedicated power source-Isolates the server power distribution system from the sources of many of less than one -half cycle or more are...
...)-Keeps input voltage to work loose, overheat, and fail. Common sources of this difference, aluminum conductors can protect the HP 9000 rp4410 and HP 9000 rp4440 servers from other metals used in the facility • Missing-phase and low-voltage detectors-Shuts equipment down automatically when a .... However, testing cannot conclusively rule out loss of aluminum; Refer to qualified contractors or consultants for HP computer equipment: • Dedicated power source-Isolates the server power distribution system from the sources of many of less than one -half cycle or more are...
Site Preparation Guide, Third Edition - HP 9000 rp4410/rp4440
Page 26
...system (an AC distribution system having no direct connection to earth according to provide a continuous grounding system. The HP 9000 rp4410 and HP 9000 rp4440 servers require two methods of grounding: • Power distribution safety grounding • High frequency intercabinet grounding Power Distribution... Guidelines Electrical Factors Raceway Systems (Electrical Conduits) (LAHJ) Raceways (electrical conduits) form part of several parts. HP recommends that these ground connections tied to metal chassis parts that is securely connected together or bonded to earth ground...
...system (an AC distribution system having no direct connection to earth according to provide a continuous grounding system. The HP 9000 rp4410 and HP 9000 rp4440 servers require two methods of grounding: • Power distribution safety grounding • High frequency intercabinet grounding Power Distribution... Guidelines Electrical Factors Raceway Systems (Electrical Conduits) (LAHJ) Raceways (electrical conduits) form part of several parts. HP recommends that these ground connections tied to metal chassis parts that is securely connected together or bonded to earth ground...