HP 22kVA 400 Volt IEC309 32A 3-Phase Watertight Input 12xC13/12xC19 Support and Manuals
Get Help and Manuals for this Hewlett-Packard item
This item is in your list!
View All Support Options Below
Free HP 22kVA 400 Volt IEC309 32A 3-Phase Watertight Input 12xC13/12xC19 manuals!
Problems with HP 22kVA 400 Volt IEC309 32A 3-Phase Watertight Input 12xC13/12xC19?
Ask a Question
Free HP 22kVA 400 Volt IEC309 32A 3-Phase Watertight Input 12xC13/12xC19 manuals!
Problems with HP 22kVA 400 Volt IEC309 32A 3-Phase Watertight Input 12xC13/12xC19?
Ask a Question
Popular HP 22kVA 400 Volt IEC309 32A 3-Phase Watertight Input 12xC13/12xC19 Manual Pages
HP Basic Power Distribution Unit Installation Guide - Page 4
... product you begin
Overview
This document provides installation instructions for qualified personnel for Server, Storage, Power, Networking, and Rack Products, available at the HP website (http://www.hp.com/support/Safety-Compliance-EnterpriseProducts). The total input current rating of appropriate current
rating. • Connect the input power cord into a grounded (earthed) electrical outlet...
HP Monitored Power Distribution Unit User Guide - Page 6
... Firmware and Web Pages 99 Upgrading the HP Firmware with FTP Protocol 100 Uploading the Binary File 100 Upgrade the Firmware and Web Pages 101 Active Alarms 101 Defining the Alarm or Event Condition 102 Type Code 0 or 1 (OS or System 103 Type 2 or 3 (PDU or User 104
10 SPECIFICATIONS 108 Model List 108 Weights and Dimensions 109 Electrical Input...
HP Monitored Power Distribution Unit User Guide - Page 7
... in other standard data center racks. HP Monitored PDU Installed (Bottom Entry Method)
HP Monitored PDU User's Guide P-164000281-Rev 1
1 Figure 1 shows an example of outlets vary by model. The number and location of a PDU installed in form factor height and several mounting configurations are 1Ph (single-phase) and 3Ph (three-phase) PDUs with electrical metering and monitoring...
HP Monitored Power Distribution Unit User Guide - Page 8
...) Figure 2 shows an example of communication port connectors, a reset opening, and operation buttons. All models feature an LCD window, a set of a 1U form factor PDU model.
Figure 2. 1U Example Model (D9N43A 1Ph Model)
HP Monitored PDU User's Guide P-164000281-Rev 1
2 Introduction
HP Monitored PDU Models
The Enterprise PDUs are available in 1U, 22U, 36U, and 42U form factor heights...
HP Monitored Power Distribution Unit User Guide - Page 13
... before operating the equipment and save this product must be performed by individuals who are NO USER SERVICEABLE PARTS inside the PDU. Chapter 2 Safety Warnings
IMPORTANT SAFETY INSTRUCTIONS - All repairs and service should follow during installation and operation of this manual for proper polarity and grounding. Please read all NA/JPN (except as noted previously). When using...
HP Monitored Power Distribution Unit User Guide - Page 19
... be installed using the manufacturer's instruction manual.
! Align the bracket with the top of your choice. Use the two 8-32 bracket mounting screws to attach the bracket to provide additional stability for the models when the PDU is installed in a rack and the rack is user-provided and should be connected to the country-specific power...
HP Monitored Power Distribution Unit User Guide - Page 26
... on the PDU (see Figure 13).
22U, 36U, 42U Model Front Panel
1U Model Front Panel
Figure 13.
Refer to the manufacturer's installation manual for instructions to connect the external contact inputs to the optional EMP for the EMP equipment. HP Monitored PDU User's Guide P-164000281-Rev 1
20 To install an optional EMP: 1. Use cable ties to the EMP...
HP Monitored Power Distribution Unit User Guide - Page 35
... manually...input connector plug with three phase wires, a protective earth (ground) wire, and no neutral wire. HP Monitored PDU User's Guide P-164000281-Rev 1
29
NOTE The On/Off positions are grouped by phase...most models.
For more ... ports Serial Service and Communication ...a four-wire input connector plug with three phase wires, a... and D9N46A models have detachable input power cords...
HP Monitored Power Distribution Unit User Guide - Page 36
...) 3W + N + PE
L1
L2
G
L3
Alignment Tab
Figure 19.
The outlets are watertight, splashproof, and dust tight.
Outlet Groups and Circuit Breakers
HP Monitored PDU User's Guide P-164000281-Rev 1
30 Example 3Ph Pin Positions
N
L1 L2
G L3
Environmental Protection
The input connector plugs have corresponding labels (see Figure 20). l Waterproof plugs are IP-rated...
HP Monitored Power Distribution Unit User Guide - Page 37
... on your PDU model.
For example, selecting PDU from the Meter submenu and then selecting Total Input from the PDU Meter submenu displays total input values for more ...Status Display When the screensaver is activated, it displays a set of all settings is available through the remote interfaces. HP Monitored PDU User's Guide P-164000281-Rev 1
31
Figure 21 illustrates the highlighted ...
HP Monitored Power Distribution Unit User Guide - Page 38
...Scroll Button
HP Monitored PDU User's Guide P-164000281-Rev 1
32
Although the button and port position varies, you can recognize the same button and port design from model to model (see...Service or Serial Port (Settings/Sensor)
2
Yellow Serial Service Port LED: RS-232 Operation and Activity Status
OFF: Normal operation
FLASHING: Communicating with EMP (if installed)
3
Green Serial Service...
HP Monitored Power Distribution Unit User Guide - Page 44
... current. LCD Interface Operation
HP
AACCTITVIVEE ALAALRAMRSMS
ALARMS HISTORY
AlaArlmarm1 t1otNo N
Alarm 1 to N
PDU
METER SECTIONS
NOTE 1
ENVIRONMENT
Input Phases
Total Input
NOTE 3 NOTE 4
Voltage...
DAISY CHAIN
IPv4
FACTORY
Contrast Orientation
Settings
DHCP
Discovery
IP address
NOTE 2 Subnet Mask
Model Part number
Serial Number Firmware Version
MAC address IPv4 address
IPv6 ...
HP Monitored Power Distribution Unit User Guide - Page 56
..., or retrieve system or network configuration settings. You can be accessed using DHCP ...password in use. The data fields include information about the PDU, including a model description, part number, serial number and the current PDU firmware...HP Monitored PDU User's Guide P-164000281-Rev 1
50 NOTE 3 The Web interface supports Microsoft Internet Explorer 8.0 and greater, Firefox (installed...
HP Monitored Power Distribution Unit User Guide - Page 116
... PDU User's Guide P-164000281-Rev 1
110 D9N55A
3P
60309 16A 5-wire
18
3
-
- Specifications
Table 16. Electrical Input and Output (By Model) (Continued)
Model
Phases
Plug/Inlet
C13 Outlets
C19 Outlets
5-20R Outlets
RF-203P-HP (LS26) Outlets
D9N46A
1P
C20 SEE NOTE
12
-
-
- D9N47A
1P
L6-30
20
4
-
- D9N48A
1P
60309 32A 3-wire
20
4
-
- D9N50A
1P
60309 32A 3-wire...
HP Monitored Power Distribution Unit User Guide - Page 120
... QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go /ilo/docs). HP Monitored PDU User's Guide P-164000281-Rev 1
114 l If you call HP:
l Active Health System log (HP ProLiant Gen8 or later products) Download and have purchased a Care Pack (service upgrade), see the Support & Drivers website (http:// www8.hp.com/us improve the documentation, send any errors, suggestions, or...