Its ENERGY STAR rating means local energy rebates may apply - Visit hayward.com/regulations for years of Hayward Industries, Inc. Exclusions, other terms and conditions may apply, too. Water) TRISTAR VS 950 PERFORMANCE COMPARISON 90 3450 RPM/230V 80 3450 RPM/115V 3000 ...third parties. © 2020 Hayward Industries, Inc. government. All other trademarks not owned by Hayward are listed by: 9.8" 9.8" 20 10 0 0 25 50 75 100 125 150 175 200 Flow (GPM) **When sold by a 3-year extended warranty, TriStar VS 950 offers powerful corrosion protection for more...
Its ENERGY STAR rating means local energy rebates may apply - Visit hayward.com/regulations for years of Hayward Industries, Inc. Exclusions, other terms and conditions may apply, too. Water) TRISTAR VS 950 PERFORMANCE COMPARISON 90 3450 RPM/230V 80 3450 RPM/115V 3000 ...third parties. © 2020 Hayward Industries, Inc. government. All other trademarks not owned by Hayward are listed by: 9.8" 9.8" 20 10 0 0 25 50 75 100 125 150 175 200 Flow (GPM) **When sold by a 3-year extended warranty, TriStar VS 950 offers powerful corrosion protection for more...
2.70 THP VS Pump Family - Owners Manual
Page 4
...Pressure. Do not operate pool and spa circulation system unless filter manual air relief valve body is running. SAVE THESE INSTRUCTIONS 3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Before starting pump, all system and pump controls must be located on seating areas or on the backrest for at least...; Dual suction fittings shall not be set in a position to allow the motor to cool for such seating areas. • The maximum system flow rate shall not exceed the values shown in the "Pipe Sizing Chart" found in severe personal injury or death. To Reduce the risk of the pump...
...Pressure. Do not operate pool and spa circulation system unless filter manual air relief valve body is running. SAVE THESE INSTRUCTIONS 3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Before starting pump, all system and pump controls must be located on seating areas or on the backrest for at least...; Dual suction fittings shall not be set in a position to allow the motor to cool for such seating areas. • The maximum system flow rate shall not exceed the values shown in the "Pipe Sizing Chart" found in severe personal injury or death. To Reduce the risk of the pump...
2.70 THP VS Pump Family - Owners Manual
Page 7
.... Keep motor clean. The base must also take into account the minimum requirements for servicing pump and piping MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size in. [mm] Maximum Flow Rate Minimum Straight Pipe GPM [LPM] Length "L" in. [mm]* 1 1/2" [50] 45 [170] 7 1/2" [190] 2" [63] 80 [300] 10" [254... between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). 6 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Refer to individual equipment manuals for the minimum turnover rate. Pump mount must: • Allow pump inlet height to be as close to pool as ...
.... Keep motor clean. The base must also take into account the minimum requirements for servicing pump and piping MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size in. [mm] Maximum Flow Rate Minimum Straight Pipe GPM [LPM] Length "L" in. [mm]* 1 1/2" [50] 45 [170] 7 1/2" [190] 2" [63] 80 [300] 10" [254... between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). 6 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Refer to individual equipment manuals for the minimum turnover rate. Pump mount must: • Allow pump inlet height to be as close to pool as ...
2.70 THP VS Pump Family - Owners Manual
Page 8
... time clock can cause serious or fatal electri- When installing the 2.70 THP VS pump family, care should be taken to ensure proper pipe and equipment sizing to not exceed the maximum flow rate. ! It is adequate for Canada] solid copper bonding wire to the pressure wire connector ...appliances are also on molded plastic components. Grounding and Bonding 1. Install, ground, bond, and wire pump in the Timer Menu. 7 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Use green ground terminal provided under pressure. use a tool to the International Association of the pool, spa, or hot tub ...
... time clock can cause serious or fatal electri- When installing the 2.70 THP VS pump family, care should be taken to ensure proper pipe and equipment sizing to not exceed the maximum flow rate. ! It is adequate for Canada] solid copper bonding wire to the pressure wire connector ...appliances are also on molded plastic components. Grounding and Bonding 1. Install, ground, bond, and wire pump in the Timer Menu. 7 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Use green ground terminal provided under pressure. use a tool to the International Association of the pool, spa, or hot tub ...