LITUHC22_Universal_HC_Series_Sell_Sheet_DIGITAL_2103
Page 1
We Build Better.® Universal HC Series Duel-Fuel Technology Gas Heater INDUSTRY'S SMALLEST FOOTPRINT HEATER* ® ONLY FROM POOL PROS 3+ YEAR PARTS & LABOR WARRANTIES** *Among leading competitive brands. **When sold by a Totally Hayward® Partner. visit hayward.com/expert for details. Exclusions, other terms and conditions may apply -
We Build Better.® Universal HC Series Duel-Fuel Technology Gas Heater INDUSTRY'S SMALLEST FOOTPRINT HEATER* ® ONLY FROM POOL PROS 3+ YEAR PARTS & LABOR WARRANTIES** *Among leading competitive brands. **When sold by a Totally Hayward® Partner. visit hayward.com/expert for details. Exclusions, other terms and conditions may apply -
HDF400 User Manual
Page 1
do not use gasoline or other flammable vapors or liquids in pool/spa heater installation. If you cannot reach your gas supplier, call your building. Immediately call the fire department. Installation and...35 WATER CHEMISTRY 35 WINTERIZATION 36 SPRING START-UP 35 TROUBLESHOOTING 41 SERVICE PARTS 44 SAVE THESE INSTRUCTIONS ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 1 51300803801 REV B IN GROUND POOL/SPA GAS HEATERS INSTALLATION & OPERATIONS MANUAL FOR YOUR SAFETY WARNING: If the information in these instructions is not followed exactly, a fire...
do not use gasoline or other flammable vapors or liquids in pool/spa heater installation. If you cannot reach your gas supplier, call your building. Immediately call the fire department. Installation and...35 WATER CHEMISTRY 35 WINTERIZATION 36 SPRING START-UP 35 TROUBLESHOOTING 41 SERVICE PARTS 44 SAVE THESE INSTRUCTIONS ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 1 51300803801 REV B IN GROUND POOL/SPA GAS HEATERS INSTALLATION & OPERATIONS MANUAL FOR YOUR SAFETY WARNING: If the information in these instructions is not followed exactly, a fire...
HDF400 User Manual
Page 2
...DIRECTED TO PRODUCT TURN ON ELECTRIC POWER AND GAS AS REQUIRED. 51300803801 REV B GETTING STARTED WHAT TO EXPECT WHEN OPERATING YOUR POOL HEATER This flow chart provides guidance to water piping. CONNECT WATER PIPING TO PRODUCT, BYPASS TO OPEN POSITION IS HEATING/COOLING NEEDED ... USE OR SPRING STARTUP Check all pool / spa water piping. INSTALLATION Verify that a pool professional perform this manual. TURN OFF ELECTRIC NO POWER AND GAS AS REQUIRED 2 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS Do not connect product to protect pool users and product by maintaining good ...
...DIRECTED TO PRODUCT TURN ON ELECTRIC POWER AND GAS AS REQUIRED. 51300803801 REV B GETTING STARTED WHAT TO EXPECT WHEN OPERATING YOUR POOL HEATER This flow chart provides guidance to water piping. CONNECT WATER PIPING TO PRODUCT, BYPASS TO OPEN POSITION IS HEATING/COOLING NEEDED ... USE OR SPRING STARTUP Check all pool / spa water piping. INSTALLATION Verify that a pool professional perform this manual. TURN OFF ELECTRIC NO POWER AND GAS AS REQUIRED 2 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS Do not connect product to protect pool users and product by maintaining good ...
HDF400 User Manual
Page 8
...floor or wall), must be installed a minimum of three feet (3') [1 meter] apart, as listed in TABLE 1: SPECIFICATIONS. Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. Replace damaged, broken, cracked, ..., and Local codes. Installation of a vacuum release or vent system, which is recommended. 8 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS The heater installation must be installed. Read, Understand, and Follow all instructions in the same plane (i.e. Limb Entrapment -
...floor or wall), must be installed a minimum of three feet (3') [1 meter] apart, as listed in TABLE 1: SPECIFICATIONS. Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. Replace damaged, broken, cracked, ..., and Local codes. Installation of a vacuum release or vent system, which is recommended. 8 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS The heater installation must be installed. Read, Understand, and Follow all instructions in the same plane (i.e. Limb Entrapment -
HDF400 User Manual
Page 9
...receptacle. WARNING - Risk of access to anyone nearby. Such a GFCI should be in open position. Push reset button. ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 9 WARNING - Before starting system pump, all electrical equipment before using them as to bond all times. Failure to follow safety ... filter manual air relief valve. Do not operate pool and spa circulation system if a system component is defective. Failure to remove pressure test plugs and/or plugs used as the filtration system, pumps, and heaters must be restored. Reference NEC codes for suction ...
...receptacle. WARNING - Risk of access to anyone nearby. Such a GFCI should be in open position. Push reset button. ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 9 WARNING - Before starting system pump, all electrical equipment before using them as to bond all times. Failure to follow safety ... filter manual air relief valve. Do not operate pool and spa circulation system if a system component is defective. Failure to remove pressure test plugs and/or plugs used as the filtration system, pumps, and heaters must be restored. Reference NEC codes for suction ...
HDF400 User Manual
Page 10
... pool is constructed so that might exceed healthful temperature limits and cause injury. Consumer Product Safety Commission. 1. Pregnant women beware! Pregnant women should check the water temperature with gas or air pressure measurements (1.0 inHg = .49 PSI = 13.5inwc) 10 ONLY USE GENUINE HAYWARD ...damage in pregnant women. Unconsciousness resulting in the birth of alcoholic beverages before entering the pool/spa to flow or not flow through the heater. Drinking of a brain-damaged or deformed child). Before entering the spa or hot tub, users should ...
... pool is constructed so that might exceed healthful temperature limits and cause injury. Consumer Product Safety Commission. 1. Pregnant women beware! Pregnant women should check the water temperature with gas or air pressure measurements (1.0 inHg = .49 PSI = 13.5inwc) 10 ONLY USE GENUINE HAYWARD ...damage in pregnant women. Unconsciousness resulting in the birth of alcoholic beverages before entering the pool/spa to flow or not flow through the heater. Drinking of a brain-damaged or deformed child). Before entering the spa or hot tub, users should ...
HDF400 User Manual
Page 11
... may provide a valuable safety feature EQUIPMENT INSPECTION: On receipt of the swimming pool/spa/hot tub heaters. Figure 3: Pallet Screw Locations SPRINKLER HEADS: The heater is designed to separate the heater from the carton inspect it and advise the carrier of rain and high humidity...or into the unit from the heater. 1. If this type of the four corners. (4) screws total ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 11 NOTICE: Damage from the heater. You may damage the heater. THE USE OF A POOL COVER IS RECOMMENDED. UNCRATING THE HEATER: Follow these steps to a well...
... may provide a valuable safety feature EQUIPMENT INSPECTION: On receipt of the swimming pool/spa/hot tub heaters. Figure 3: Pallet Screw Locations SPRINKLER HEADS: The heater is designed to separate the heater from the carton inspect it and advise the carrier of rain and high humidity...or into the unit from the heater. 1. If this type of the four corners. (4) screws total ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 11 NOTICE: Damage from the heater. You may damage the heater. THE USE OF A POOL COVER IS RECOMMENDED. UNCRATING THE HEATER: Follow these steps to a well...
HDF400 User Manual
Page 12
... to the structure. For minimum exhaust vent clearances for non‐binding removal of the top access panels. 12 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS OUTDOOR AND INDOOR INSTALLATION AND SERVICE CLEARANCES: For both outdoors and indoors installations, the installation clearances from the top of ...the appliance. 51300803801 REV B LOCATING THE HEATER: Locate the pool/spa heater in an area where leakage of the heat exchanger or connections will not result in damage to the area adjacent to the...
... to the structure. For minimum exhaust vent clearances for non‐binding removal of the top access panels. 12 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS OUTDOOR AND INDOOR INSTALLATION AND SERVICE CLEARANCES: For both outdoors and indoors installations, the installation clearances from the top of ...the appliance. 51300803801 REV B LOCATING THE HEATER: Locate the pool/spa heater in an area where leakage of the heat exchanger or connections will not result in damage to the area adjacent to the...
HDF400 User Manual
Page 14
... also been molded into the design of Hayward's HDF series pool heater to allow any moisture in the packaging ... of the unit. 51300803801 REV B CONDENSATE MANAGEMENT: In certain running conditions, any pool heater can produce condensate while it is running or sweat during combustion will be done using...HAYWARD REPLACEMENT PARTS If a longer length is disconnected from the overflow port, the drain hose is created by the unit will increase the life and reliability of the unit. The formation of moisture on the heat exchanger depends on the bottom of the exhaust side of your new pool heater...
... also been molded into the design of Hayward's HDF series pool heater to allow any moisture in the packaging ... of the unit. 51300803801 REV B CONDENSATE MANAGEMENT: In certain running conditions, any pool heater can produce condensate while it is running or sweat during combustion will be done using...HAYWARD REPLACEMENT PARTS If a longer length is disconnected from the overflow port, the drain hose is created by the unit will increase the life and reliability of the unit. The formation of moisture on the heat exchanger depends on the bottom of the exhaust side of your new pool heater...
HDF400 User Manual
Page 15
... are supplied in the consumer kit shipped with your application requires the use with the HDF gas pool heaters from the factory ready to be followed to convert the heater from it 90° clockwise. Verify manifold pressure after converting the unit to operate with the ... provincial authorities having jurisdiction. Only two components, a molded fuel/air mixer and the appropriate field conversion label, are shipped from Hayward. All HDF heaters are needed to convert the unit to the unit. 2. The installation is not proper and complete until the operation of the ...
... are supplied in the consumer kit shipped with your application requires the use with the HDF gas pool heaters from the factory ready to be followed to convert the heater from it 90° clockwise. Verify manifold pressure after converting the unit to operate with the ... provincial authorities having jurisdiction. Only two components, a molded fuel/air mixer and the appropriate field conversion label, are shipped from Hayward. All HDF heaters are needed to convert the unit to the unit. 2. The installation is not proper and complete until the operation of the ...
HDF400 User Manual
Page 19
...the manufacturer, or one of 90° Elbows Maximum Vent Pipe Length, Horizontal & Ver cal ( .) 0 45 1 45 2 35 3 25 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 19 charge Opening (ft.) (m) Flat to 6/12 1.0 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over...Roof for Vent Cap POSITIVE PRESSURE (HORIZONTAL OR VERTICAL, CATIII) VENTING: When installed according to the following instructions, heaters meet the criteria for use with this pool heater. VENT SIZING: Vent pipe diameter must be used in Table 8. The vent pipe must be either horizontal or vertical...
...the manufacturer, or one of 90° Elbows Maximum Vent Pipe Length, Horizontal & Ver cal ( .) 0 45 1 45 2 35 3 25 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 19 charge Opening (ft.) (m) Flat to 6/12 1.0 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over...Roof for Vent Cap POSITIVE PRESSURE (HORIZONTAL OR VERTICAL, CATIII) VENTING: When installed according to the following instructions, heaters meet the criteria for use with this pool heater. VENT SIZING: Vent pipe diameter must be used in Table 8. The vent pipe must be either horizontal or vertical...
HDF400 User Manual
Page 22
...expert for assistance. Follow local gas codes for 400,000 Btu/hr Gas Appliance Regulation Type Fuel Type Gas Line Material 0 to the pool heater and any other gas appliances if they are on the left side of the gas manifold assembly during service. It is VERY IMPORTANT when ... in the cabinet side. NATURAL GAS: The gas meter must have sufficient capacity to provide adequate vaporization for the heater, refer to 10 N/A N/A 3/4 3/4 7/8 22 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS If the propane gas tank is not responsible for the proper gas line size. Propane tanks must have...
...expert for assistance. Follow local gas codes for 400,000 Btu/hr Gas Appliance Regulation Type Fuel Type Gas Line Material 0 to the pool heater and any other gas appliances if they are on the left side of the gas manifold assembly during service. It is VERY IMPORTANT when ... in the cabinet side. NATURAL GAS: The gas meter must have sufficient capacity to provide adequate vaporization for the heater, refer to 10 N/A N/A 3/4 3/4 7/8 22 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS If the propane gas tank is not responsible for the proper gas line size. Propane tanks must have...
HDF400 User Manual
Page 23
...on the ribbon cable attached to have water connection on the left side. Do not install any restriction in the water pipe between the heater outlet and the pool/spa with right-side water connections. To complete this alteration, follow the instructions below and reference Figures 1 and Figure 13 as needed... for use with pool and spa/hot tub water furnished by installing the screw removed in Step 1 in the new location. Lift the front lip of life. ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 23 With the front of the top access panel elevated, slide the panel toward the rear ...
...on the ribbon cable attached to have water connection on the left side. Do not install any restriction in the water pipe between the heater outlet and the pool/spa with right-side water connections. To complete this alteration, follow the instructions below and reference Figures 1 and Figure 13 as needed... for use with pool and spa/hot tub water furnished by installing the screw removed in Step 1 in the new location. Lift the front lip of life. ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 23 With the front of the top access panel elevated, slide the panel toward the rear ...
HDF400 User Manual
Page 30
... IGNITER WARM‐UP 20 SEC. MAX FLAME SENSED, IGNITION SUCCESSFUL ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 30 The full lighting and shutdown instructions are included in this mode, the heater will accept a mode change from "STANDBY" to indicate the progression of the unit's... the blower. It is equipped with the set point cannot be displayed again. CONTROL SETUP This pool heater is normal for high return water temperature (maximum of heater components and their locations. The control energizes the igniter during any user panel input. 3. Figure 23...
... IGNITER WARM‐UP 20 SEC. MAX FLAME SENSED, IGNITION SUCCESSFUL ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 30 The full lighting and shutdown instructions are included in this mode, the heater will accept a mode change from "STANDBY" to indicate the progression of the unit's... the blower. It is equipped with the set point cannot be displayed again. CONTROL SETUP This pool heater is normal for high return water temperature (maximum of heater components and their locations. The control energizes the igniter during any user panel input. 3. Figure 23...
HDF400 User Manual
Page 31
... original operating mode ("SPA" or "POOL"). 31 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS TEMPERATURE MAXIMUM SET POINT: The digital thermostat in adjustment mode. 5. After 3 seconds, the thermostat enters maximum temperature lock adjustment mode. 4. Both the "SPA" indicator light and the numeric display flashes rapidly when in this pool heater allows the user to the...
... original operating mode ("SPA" or "POOL"). 31 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS TEMPERATURE MAXIMUM SET POINT: The digital thermostat in adjustment mode. 5. After 3 seconds, the thermostat enters maximum temperature lock adjustment mode. 4. Both the "SPA" indicator light and the numeric display flashes rapidly when in this pool heater allows the user to the...
HDF400 User Manual
Page 36
...that soot up due to improper gas level in the tank resulting in pool heater design and manufacture. WATER CHEMISTRY: WARNING: WATER CHEMISTRY Failure to or failure of your pool heater is made from around the heater. 4. Check that the pump is operating and the system is filled ... water chemistry: ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 36 The following factors are to be performed by qualified service personnel is recommended to keep the pool/spa safe and sanitary and will not be responsible for heaters that was under water. The heater's venting areas (the louvered top...
...that soot up due to improper gas level in the tank resulting in pool heater design and manufacture. WATER CHEMISTRY: WARNING: WATER CHEMISTRY Failure to or failure of your pool heater is made from around the heater. 4. Check that the pump is operating and the system is filled ... water chemistry: ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 36 The following factors are to be performed by qualified service personnel is recommended to keep the pool/spa safe and sanitary and will not be responsible for heaters that was under water. The heater's venting areas (the louvered top...
HDF400 User Manual
Page 37
...chlorine or bromine Tablets in high chemical concentrations flowing through the heater is recommended as part of the heater, and a check valve must either partially drain the pool, or isolate the pool heater from the heater. 8. Make sure your piping arrangement meets the chlorinator installation requirements... from the water path when not heating. Re-install drain plug. 37 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS Set the heater to drain from the pool using the keypad. 2. Care must run continuously. CHLORINATOR INSTALLATION: Chlorinators must be installed downstream...
...chlorine or bromine Tablets in high chemical concentrations flowing through the heater is recommended as part of the heater, and a check valve must either partially drain the pool, or isolate the pool heater from the heater. 8. Make sure your piping arrangement meets the chlorinator installation requirements... from the water path when not heating. Re-install drain plug. 37 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS Set the heater to drain from the pool using the keypad. 2. Care must run continuously. CHLORINATOR INSTALLATION: Chlorinators must be installed downstream...
HDF400 User Manual
Page 41
...board is corrected and resume operation. WARNING: Pool heaters are not for the use of qualified personnel trained and experienced in the installation and servicing of the heater with the pump shut off could cause heater overheating and fire. The heater can be displayed. If there is off... can be purchased from manufacturer in the heater. After the pump has primed, this situation, when the pump shuts down the heater will automatically reset when an error condition is keyed to fire. ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 41 These instructions and procedures ...
...board is corrected and resume operation. WARNING: Pool heaters are not for the use of qualified personnel trained and experienced in the installation and servicing of the heater with the pump shut off could cause heater overheating and fire. The heater can be displayed. If there is off... can be purchased from manufacturer in the heater. After the pump has primed, this situation, when the pump shuts down the heater will automatically reset when an error condition is keyed to fire. ONLY USE GENUINE HAYWARD REPLACEMENT PARTS 41 These instructions and procedures ...
HDF400 User Manual
Page 44
... & Burner Gasket Kit Silicone Tubes for Pressure Switch and Valve Reference Header O-Ring Kit 44 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS CABINET PARTS Control Access Panel Cabinet Top Header Controls Cover Water Side Trim Panels Cabinet Base ELECTRONIC CONTROLS...LIST The following repair parts are available from Hayward and through your local distributor. When ordering parts, include the complete pool heater model number listed on the unit's rating plate, located near the junction boxes on the exhaust side of the heater. (Example: HDF400) All service must be performed by a qualified...
... & Burner Gasket Kit Silicone Tubes for Pressure Switch and Valve Reference Header O-Ring Kit 44 ONLY USE GENUINE HAYWARD REPLACEMENT PARTS CABINET PARTS Control Access Panel Cabinet Top Header Controls Cover Water Side Trim Panels Cabinet Base ELECTRONIC CONTROLS...LIST The following repair parts are available from Hayward and through your local distributor. When ordering parts, include the complete pool heater model number listed on the unit's rating plate, located near the junction boxes on the exhaust side of the heater. (Example: HDF400) All service must be performed by a qualified...
Energy Guide Label
Page 1
Government Federal law prohibits removal of Similar Models 96.0 Most Efficient • Efficiency range based only on models fueled by natural gas. • For more information, visit www.ftc.gov/energy. 51300052801 REV C Models H250FD, SW250DH, H400FD, SW400DH, HDF275, HDF400, HDF400BH, W3H250FD, W3H400FD Thermal Efficiency 84.0 82.0 Least Efficient Efficiency Range of this label before consumer purchase. Pool Heater Natural or Propane Gas Hayward Industries, Inc. S. U.
Government Federal law prohibits removal of Similar Models 96.0 Most Efficient • Efficiency range based only on models fueled by natural gas. • For more information, visit www.ftc.gov/energy. 51300052801 REV C Models H250FD, SW250DH, H400FD, SW400DH, HDF275, HDF400, HDF400BH, W3H250FD, W3H400FD Thermal Efficiency 84.0 82.0 Least Efficient Efficiency Range of this label before consumer purchase. Pool Heater Natural or Propane Gas Hayward Industries, Inc. S. U.