Installation & Operation Manual Central Air Conditioner 10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR No.0010572324 K The information contained in this booklet is subject to change without notice.
User Manual - Page 2

...and periodic maintenance requirements. Failure to follow these regulations may result in improper installation, adjustment, service or maintenance possibly resulting in a fire or an electric shock due to the imposition of any codes or regulations. While the instructions are addressed primarily to the installer, useful maintenance information is not attached securely, it could result in...
User Manual - Page 3

...12 9.Miscellaneous 12 9.1.Replacement parts 12 9.2.Troubleshooting guide 12 9.3.Wiring diagram 12 1.INTRODUCTION This manual contains the installation and operating instructions for Model Number 1 3.Specification 2 4.Unit Inspection 5 5.Equipment Protection From Environment 5 6.Installation 5 6.1. The owner should retain this manual and any instructions packaged with separate equipment...
User Manual - Page 4

...-60A1VAR/S 2 MODEL: HC18A1VAR HC24A1VAR HC30A1VAR HC36A1VAS HC42A1VAR HC48A1VAR HC60A1VAR Unit Supply Voltage 208/230-1-60 Normal Voltage Range Compressor Brand Minimum Circuit Amps 10.1 Max Fuse or Max CKT. Lbs (kg) 141[64] 143 [65] 158[72] 165[75] 231[105] 222[101] 231[105] 222[101] 246[112] 242[110] 3.SPECIFICATION The...
User Manual - Page 5

Physical and electrical specifications are illustrated in Table 3 for 12 SEER systems respectively. Lbs (kg) ... are provided in Figure 1. Table 3: Model:HC18-60C1VAR MODEL: Unit Supply Voltage Normal Voltage Range HC18C1VAR HC24C1VAR HC30C1VAR HC36C1VAR 208/230-1-60 197 - 253 HC42C1VAR HC48C1VAR HC60C1VAR Bristol Compressor Brand Bristol H29A H20J H29A H23R H20R H23R...
User Manual - Page 6

....11[5550] Net Dimensions - Table 5: Model:HC18-60D1VAR MODEL: HC18D1VAR HC24D1VAR HC30D1VAR HC36D1VAR HC42D1VAR HC48D1VAR HC60D1VAR Unit Supply Voltage 208/230-1-60 Normal Voltage Range Compressor Brand 197 - 253 Bristol Minimum Circuit Amps 8.6 11.6 12.4 15.9 17.7 21.8 33.3 Max Fuse or Max CKT. Physical and electrical specifications are provided in Table 5 for the...
User Manual - Page 7

...The metal parts of the...code authorities at the time the first installation... a problem, special attention should be installed in ...servicing. WARNING - Avoid having lawn sprinkler heads spray directly on the unit. Frequent washing of supporting members. Location where external water drainage cannot collect around the unit. If damage is to be given to the unit before attempting any installation...
User Manual - Page 8

... For rooftop application, make sure the building construction can support the weight and that proper consideration is also a consideration...installed in Figure 2. Service Access 18" Min. 10" Min. 10" 10" Figure 2 The minimum clearances for youngsters to run around the unit with connection side facing the wall. Condenser air enters from back wall with subsequent damage to the compressor...
User Manual - Page 9

... an undesirable heat transfer resulting in order to be adequately supported. Generally 3/8" wall thickness of line. Liquid line does ...-grade copper piping (dehydrated and sealed) should not be installed in place and the connections are exposed to keep tubing ... toward the compressor, approximately 1/2" for the liquid line to prevent liquid refrigerant flashing to the compressor, it is...
User Manual - Page 11

...wet rag to charging the system. Repair any leaks found , repair it stops. The indoor conditions ... quench with refrigerant. Evacuation All new installations must be cut square. Proper evacuation assures... be an approved match per the unit specification. It is the recommended evacuation procedure: ...that both liquid and suction valve service ports. 2.Evacuate the interconnecting tubing...
User Manual - Page 12

...wiring within special tybe be sure to this instruction). Do not use the waterproof tube when installation the outdoor unit power supply wiring.(See the...codes and regulations. If the capacity of good contact 75 5 10 17 25 29 between thermometer and line. Ground the unit. Be sure of the power circuit is insufficient or there is incomplete electrical work according to the installation manual...
User Manual - Page 13

.... 4.Turn fan switch to "AUTO". Turn system switch to see Instructions under "Charging the System"). 7.Replace service port caps. The condensing unit rating plate and the tables of "Physical and Electrical Specifications / Outdoor Units" (Table 1 and 2) provide pertinent data necessary for disconnecting power service to the unit. Leave this application and the proper procedure for...
User Manual - Page 14

... to the troubleshooting guide (Table 10) included in this manual.(P14) Table 10:Troubleshooting Guide ! Disconnect power to the appropriate wiring diagram included in this overload to the unit before condemning the compressor. 9.MISCELLANEOUS 9.1. To do so may be moved to stop on an automatic open overload device or blow a fuse. Poor electrical service can take up...
User Manual - Page 15

...setting Set thermostat correctly No cooling Defective contactor Check for blockage. Recover refrigerant, evacuate & recharge 13 Check and tighten all connections. Blocked outdoor coil Clear away leaves and other debris Correct system charge Repair or replace...At compressor terminals, voltage must be 400CFM/Ton Incorrect refrigerant charge Charge correctly per instruction. replace air...
User Manual - Page 16

... w ithout optional electr ic heater ki t. REPLACEMENT WIRE MUST BE THE SAME GAGE AND INSULATION ...COMPRESSOR CONTACT OR CCH - RUN CAPA CITOR COMPRESSOR RVS - BLUE GY - GRAY BR - Opti onal com ponents m ay be field or factory installed... OLENOID STCAP - TRANSFORMER 230/208 SELECTA BLE COLOR CODES BK - GREEN OR - ORANGE PU - WHITE ... er ki t inst allation instructions for syst em to operate...

Haier HC60C1VAR Reviews

Do you have an experience with the Haier HC60C1VAR that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.

Popular Haier HC60C1VAR Search Terms

The following terms are frequently used to search for Haier HC60C1VAR support:

Ask a New Question
Use the box below to post a new question about Haier HC60C1VAR.
Manuals / Documents
Download any of our Haier HC60C1VAR manuals for free!

We have the following 1 documents available for the Haier HC60C1VAR:
  • User Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HC60C1VAR manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier HC60C1VAR user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.