User Manual - Page 1
Please keep this manual carefully. ROOM AIR CONDITIONER
OUTDOOR UNIT INSTALLATION INSTRUCTIONS
AU142AEEAA AU182AEEAA
CONTENTS
Name of Parts 1 Safety Cautions 2-3 Installation Procedure---------4-13
AU242AGEAA
AU282AHEAA AU28NAHEAA
AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA
No.0010577959
Before using the air conditioner,please read this manual properly for future use.
User Manual - Page 3
... using the conditioner will damage the conditioner, and may...air-conditioner the base should be at hand so that they can ensure the correct operation of death or serious injuries. When need maintenance and repairment, call dealer to the new user. Incorrect operations may cause electrical shock or fire hazard. INSTRUCTIONS... beings. Incorrect maintenance and repairment may fall down and cause...
User Manual - Page 4
... to air-conditioner may cause fire hazard. Connect earthing wire. May not use correctly-typed fuse. No goods or nobody is deinstalled or reinstalleddealer should not be installed in case of goods and people may cause faults or fire accidents. The falling of refrigerant leakage.
Earthing
Only use wire or any other materials replacing fuse...
User Manual - Page 5
... air inlet and air outlet . Mount guide-louvers to avoid short circuiting.
(1) Open space requirement around the unit
Air inlet L3
L2
500
Air
(Servicing
inlet
space)
Air outlet
L1
Note :
(1). When installing... parts with strong winds.
Place where noise and hot air may not be kept from other heat sources. Install the unit so that the air outlet section of installation ...
User Manual - Page 6
... Fix the unit in a proper way according to the following . Note: (1) Place the concrete foundation deep enough. Install the unit so that the angle of inclination must be less than 3 degrees.
(2) Installation sketch of outdoor unit
3.
Installation Procedure
Installation of outdoor unit
AU142AEEAA AU182AEEAA
780
Power Wiring Terminal
640 25
Power Wiring Distribution Hole
5
User Manual - Page 7
Installation Procedure
Installation of outdoor unit
270
500
AU242AGEAA
810
Power Wiring Terminal
Power Wiring Distribution Hole
680
580
315
288
AU282AHEAA AU28NAHEAA
948
Power Wiring Terminal
Power Wiring Distribution Hole
580
380 840
25
340
6
User Manual - Page 8
Refrigerant piping
(1) Outline piping
AU142AEEAA AU182AEEAA AU242AGEAA AU282AHEAA AU28NAHEAA AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA
Flare connection
Gas pipe
3-way stop valve
Indoor unit
Liquid pipe Flare connection
Outdoor unit
3-way stop valve
7 Installation Procedure
Installation of outdoor unit
AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA
948 Power wiring Terminal
380 1250
25 ...
User Manual - Page 9
...refrigerant oil at half union as possible. Be careful not to let foreign matters, such as possible not to crush the pipe. Model
AU142AEEAA
AU182AEEAA... for one way piping length and vertical height difference.
Installation Procedure
(2) Piping size
Refrigerant piping
AU142AEEAA AU182AEEAA
AU242AGEAA AU282AHEAA AU28NAHEAA
AU36NAIEAA AU48NAIEAA AU52ANIEAA AU60NAIEAA
Liquid pipe Gas...
User Manual - Page 10
...BRING BRAZED
LINE PRESSURE GAUGE
SWEAT JOINT
LARGE SLIP-ON CONNECTOR
SERVICE HOUSE
CYLINDER PRESSURE GAUGE
CYLINDER OF NITROGEN
Check if the ...air tightness test adopts nitrogen tank to give pressure according to 24 hours later, each joint use sense of outdoor unit, tighten the valve rod before giving pressure (both gas
and liquid valve rods).
Installation Procedure
Refrigerant...
User Manual - Page 11
... time depends on the meter separator and stop vacuumizing. 1 hour later to charge the refrigerant.
7. When vacuumizing, it shall charge Mg additional refrigerant per meter. If after 3 hours vacuumizing, it is any leaking point and repair the them. Piping and indoor unit vacuumizing
Use vacuum pump to charge additional refrigerant. Installation Procedure
Refrigerant piping
6.
User Manual - Page 12
Installation...air conditioner should be no less 3 mm. and the distance between its two contacts should be replaced by the manufacturer or its service...Model
Circuit breaker
Power source Earth leakage breaker
wire size
Phase Switch breaker Overcurrent protector (minimum) Switch
Leak
(A)
rated capacity (A) (mm2) breaker(A) current(mA)
AU142AEEAA AU182AEEAA... and instruction manual.
11...
User Manual - Page 13
Installation Procedure
For: AU142AEEAA, AU182AEEAA
To Indoor Unit
Electric wiring
OUTDOOR UNIT
1 2 3
TERMINAL BLOCK
Y/G
FIG.1
For :, AU242AGEAA, ... WIRES MUST BE WIRED ACCORDING TO FIG.1 FIG.2 FIG.3.INCORRECT WIRING CAUSE EQUIPMENT DAMAGE.
(3) Wiring procedure
1) Remove set screws on the side before taking off the front panel toward the direction shown in figure.
2) Connect wires to the...
User Manual - Page 14
... the unit continuously for all Heat pump models)
Confirm whether the power source breaker ... ELECTRIC POWER IS DISCONNECTED FOR SERVICING. Suction pressure at check joint... malfunction between return air and supply air for gas pipe. Trouble display
Failure description
...Installation Procedure
Electric wiring
6. sensor abnormal Indoor coil temp. sensor abnormal
Code on wired Flash times of...