User Manual
Page 1
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AS07GS1ERA AS09GS1ERA AS12GS1ERA Contents PARTS AND FUNCTIONS 2 OPERATION 3 INDOOR UNIT INSTALLAION 5 MAINTENANCE 9 CAUTIONS 10 TROUBLE SHOOTING 11 ●Please read this operation manual for future reference. 0010535380 Keep this operation manual before using the air conditioner.
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AS07GS1ERA AS09GS1ERA AS12GS1ERA Contents PARTS AND FUNCTIONS 2 OPERATION 3 INDOOR UNIT INSTALLAION 5 MAINTENANCE 9 CAUTIONS 10 TROUBLE SHOOTING 11 ●Please read this operation manual for future reference. 0010535380 Keep this operation manual before using the air conditioner.
User Manual
Page 2
...and timer setting. FAN SPEED display AUTO LO MED HI 4. TIMER OFF display 8. MODE button 13. SET / LIGHT button 20. If there is kept pressed,time will increase or decrease 1min. Parts and Functions Indoor Unit Remote controller 1 8 2 3 4 5 6 7 1 Inlet 6 Display board 2 Inlet grille 7 Emergency Switch 3 Outlet 4 Vertical blade 8 Air Purifying Filter (inside) (adjust left and right air flow) 5 Horizontal flap (adjust up .Please change batteries. Mode display Operation mode AUTO COOL DRY HEAT FAN Remote controller 2. TIMER ON display 9. POWER ON/OFF button...
...and timer setting. FAN SPEED display AUTO LO MED HI 4. TIMER OFF display 8. MODE button 13. SET / LIGHT button 20. If there is kept pressed,time will increase or decrease 1min. Parts and Functions Indoor Unit Remote controller 1 8 2 3 4 5 6 7 1 Inlet 6 Display board 2 Inlet grille 7 Emergency Switch 3 Outlet 4 Vertical blade 8 Air Purifying Filter (inside) (adjust left and right air flow) 5 Horizontal flap (adjust up .Please change batteries. Mode display Operation mode AUTO COOL DRY HEAT FAN Remote controller 2. TIMER ON display 9. POWER ON/OFF button...
User Manual
Page 3
... following modes: Room Designated Timer Fan Operation temperature temperature mode speed mode Above 23oC Below 23oC 26oC 23oC No AUTO COOL No AUTO HEAT emergency operation switch Pi It is set swing position. 3 For each press, fan speed changes as follows: Remote controller: AUTO LO MED HI Air conditioner is not available in COOLor DRY mode , otherwise, condensate water might occur at LOW speed regardless of auto operation, air conditioner will run automatically for a while. And temp. Under this operation. Operation Mode AUTO COOL DRY HEAT FAN Remote Controller...
... following modes: Room Designated Timer Fan Operation temperature temperature mode speed mode Above 23oC Below 23oC 26oC 23oC No AUTO COOL No AUTO HEAT emergency operation switch Pi It is set swing position. 3 For each press, fan speed changes as follows: Remote controller: AUTO LO MED HI Air conditioner is not available in COOLor DRY mode , otherwise, condensate water might occur at LOW speed regardless of auto operation, air conditioner will run automatically for a while. And temp. Under this operation. Operation Mode AUTO COOL DRY HEAT FAN Remote Controller...
User Manual
Page 4
... 1OC SLEEP operation starts SLEEP operation stops In HEAT mode 4 3. setting so that room temperature won 't be adjusted and time being set. Temp.setting Unit stop In COOL, DRY mode 2. When TIMER function is set up, if user resets TIMER function, the sleeping function will be cancelled; After the sleeping function is set , the quiet sleeping function can't be set up. In HEAT mode, fan speed automatically takes medium speed of AUTO fan mode. (2) SOFT Operation You can use this function after SLEEP mode starts,temp will become 1OC higher than temp.setting...
... 1OC SLEEP operation starts SLEEP operation stops In HEAT mode 4 3. setting so that room temperature won 't be adjusted and time being set. Temp.setting Unit stop In COOL, DRY mode 2. When TIMER function is set up, if user resets TIMER function, the sleeping function will be cancelled; After the sleeping function is set , the quiet sleeping function can't be set up. In HEAT mode, fan speed automatically takes medium speed of AUTO fan mode. (2) SOFT Operation You can use this function after SLEEP mode starts,temp will become 1OC higher than temp.setting...
User Manual
Page 5
..., display changes as previous one. Please contact the installer or local authority for charging 5 Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC ROHS The products are in the field and • 1+2 the total refrigerant charge on the remote controller stops flashing. 5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED...
..., display changes as previous one. Please contact the installer or local authority for charging 5 Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC ROHS The products are in the field and • 1+2 the total refrigerant charge on the remote controller stops flashing. 5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED...
User Manual
Page 6
Remote controller (1) R-03 dry battery (2) Mounting plate (1) Drain hose (1) Plastic cap (4) Ø4X25 Screw (4) Air purifying filter(Optional) (1) Selection of Pipe FOR 07K 09K 12K Drawing for the installation of indoor units The models adopt HFC free refrigerant R410A more than 15 cm Attention must be more than 10cm Arrangement of piping directions Rear left . ƽ In the case of fixing the remote controller on a wall, place where the indoor unit can...
Remote controller (1) R-03 dry battery (2) Mounting plate (1) Drain hose (1) Plastic cap (4) Ø4X25 Screw (4) Air purifying filter(Optional) (1) Selection of Pipe FOR 07K 09K 12K Drawing for the installation of indoor units The models adopt HFC free refrigerant R410A more than 15 cm Attention must be more than 10cm Arrangement of piping directions Rear left . ƽ In the case of fixing the remote controller on a wall, place where the indoor unit can...
User Manual
Page 7
...; Remove terminal cover at right bottom corner of indoor unit, then take off with adhesive tape Indoor/outdoor electric cable Lid for right piping Lid for under piping pipe Heat insulation material Lid for left -rear piping which is first fixed ", for the plate to the heat insulation of wall hole. Insert the drain hose into the dent of heat insulation materials of the wall Hole When the mounting...
...; Remove terminal cover at right bottom corner of indoor unit, then take off with adhesive tape Indoor/outdoor electric cable Lid for right piping Lid for under piping pipe Heat insulation material Lid for left -rear piping which is first fixed ", for the plate to the heat insulation of wall hole. Insert the drain hose into the dent of heat insulation materials of the wall Hole When the mounting...
User Manual
Page 8
...;xed? The type of indoor and outdoor units carefully. Check Items for air conditioner. ƽ In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. ƽ For installation in other places, use a circuit breaker as far as shown below. ƽ Insert the cable from a ditch ƽPlease pour water in the drain pan of the wall hole, in a room, please apply heat insulation to...
...;xed? The type of indoor and outdoor units carefully. Check Items for air conditioner. ƽ In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. ƽ For installation in other places, use a circuit breaker as far as shown below. ƽ Insert the cable from a ditch ƽPlease pour water in the drain pan of the wall hole, in a room, please apply heat insulation to...
User Manual
Page 9
... stopper, and remove the filter downward. Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Do not block the air inlet or outlet Remote Controller Indoor Body Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used for a long time,no need for replacement. Attach the filter. Use the louvers...
... stopper, and remove the filter downward. Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Do not block the air inlet or outlet Remote Controller Indoor Body Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used for a long time,no need for replacement. Attach the filter. Use the louvers...
User Manual
Page 10
... at infants or the aged. Do not attempt to damage the power supply cord. STRICT ENFORCEMENT Take care not to install the air conditioner by yourself. PROHIBITION Do not start or stop the operation button and contact sales shop. earthing Do not operate the switch with a circuit breaker Check proper installation of food, art work, precise equipment, breeding, or cultivation. Do not try to the...
... at infants or the aged. Do not attempt to damage the power supply cord. STRICT ENFORCEMENT Take care not to install the air conditioner by yourself. PROHIBITION Do not start or stop the operation button and contact sales shop. earthing Do not operate the switch with a circuit breaker Check proper installation of food, art work, precise equipment, breeding, or cultivation. Do not try to the...
User Manual
Page 11
... first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in line with the appliance. 9. Is the air filter dirty? Are there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in unit operation, air filter may blow out mist. Is temperature set correctly? Trouble shooting Before asking for service, check the following...
... first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in line with the appliance. 9. Is the air filter dirty? Are there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in unit operation, air filter may blow out mist. Is temperature set correctly? Trouble shooting Before asking for service, check the following...