Manual
Page 2
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Users ...13 Services ...14 IPMI ...15 Time Setting ...17 Sessions ...18 LDAP ...19 Updates ...20 Utilities ...21 Server Information ...22 Power Control ...22 Voltages ...23 Thermal ...24 Fans ...24 Temperature ...25 System Event Log ...26 Event Management...
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Users ...13 Services ...14 IPMI ...15 Time Setting ...17 Sessions ...18 LDAP ...19 Updates ...20 Utilities ...21 Server Information ...22 Power Control ...22 Voltages ...23 Thermal ...24 Fans ...24 Temperature ...25 System Event Log ...26 Event Management...
Manual
Page 12
... configure the BMC related settings through the BMC port. Shared Mode When set to Shared Mode, you can configure the BMC related settings through the NIC2 port. (Shared NIC Mode) Failover Mode When set to Dedicate Mode, you can view and modify the network settings on this screen. Dedicate Mode When set to take effect of changes. 11 Select the Network Mode from the drop-down list. Configuration Network You can configure the BMC related settings through the BMC or NIC2 port. (Backup Mode...
... configure the BMC related settings through the BMC port. Shared Mode When set to Shared Mode, you can configure the BMC related settings through the NIC2 port. (Shared NIC Mode) Failover Mode When set to Dedicate Mode, you can view and modify the network settings on this screen. Dedicate Mode When set to take effect of changes. 11 Select the Network Mode from the drop-down list. Configuration Network You can configure the BMC related settings through the BMC or NIC2 port. (Backup Mode...
Manual
Page 16
... two sections: IPMI Serial and IPMI Settings. The Connection Mode Settings allows user to select the Console redirection type and to disable individual channels, or change the behavior of the out-of-band interfaces. For example, Operator privilege does not allow the capability to manage the system from the drop-down list. Users This may be executed. Operator All BMC commands are four serial configuration in IPMI Serial: Connection Mode Settings, Baud Rate, Flow...
... two sections: IPMI Serial and IPMI Settings. The Connection Mode Settings allows user to select the Console redirection type and to disable individual channels, or change the behavior of the out-of-band interfaces. For example, Operator privilege does not allow the capability to manage the system from the drop-down list. Users This may be executed. Operator All BMC commands are four serial configuration in IPMI Serial: Connection Mode Settings, Baud Rate, Flow...
Manual
Page 10
... TFTP service application. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is ...available.) ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x20 0x0a 0x3c 0x00 0x0e 0x00 0x00 0x0a 0x01 0x1b 0x34 0x69 0x6d 0x61 0x67 0x65 0x2e 0x52 0x42 0x55 Command format: raw : 0x69 0x6d 0x61 0x67 0x65 0x2e 0x52 0x42 0x55 = image.RBU [5] Check upload status...
... TFTP service application. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is ...available.) ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x20 0x0a 0x3c 0x00 0x0e 0x00 0x00 0x0a 0x01 0x1b 0x34 0x69 0x6d 0x61 0x67 0x65 0x2e 0x52 0x42 0x55 Command format: raw : 0x69 0x6d 0x61 0x67 0x65 0x2e 0x52 0x42 0x55 = image.RBU [5] Check upload status...
Manual
Page 3
... Console (Linux 13 1-5-1 Tomcat Installation Procedure 13 1-5-2 PostgreSQL Installation Procedure 13 1-5-3 Restore dbRMCv0XX.backup 14 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IPv6 Configuration...
... Console (Linux 13 1-5-1 Tomcat Installation Procedure 13 1-5-2 PostgreSQL Installation Procedure 13 1-5-3 Restore dbRMCv0XX.backup 14 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IPv6 Configuration...
Manual
Page 38
...events fail Set IPv6 trap IP/enable destination fail Get platform events fail Get IPv6 trap IP/enable destination fail Match rack node info fail Match RMC/BMC IP fail Get FRU fail Save Event Log to log file fail Copy catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is not connected or node management related command failed too many times. Server log...
...events fail Set IPv6 trap IP/enable destination fail Get platform events fail Get IPv6 trap IP/enable destination fail Match rack node info fail Match RMC/BMC IP fail Get FRU fail Save Event Log to log file fail Copy catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is not connected or node management related command failed too many times. Server log...
Manual
Page 4
...2-1 Removing Chassis Cover 16 2-2 Removing and Installing the Fan Duct 17 2-3 Installing the CPU 18 2-4 Installing the Heat Sink 19 2-5 Installing the Memory 21 2-5-1 Triple Channel Memory Configuration 21 2-5-2 Installing a Memory 22 2-6 Installing the PCI Expansion Card 23 2-6-1 Installing Add-on Card (MNXE2/MEZZ_2/Optional 28 2-6-2 Installing Add-on Card (MLIZS/MEZZ_2/Optional 29 2-7 Installing the Hard Disk Drive 31 2-8 Replacing the FAN Assemblly 32 2-9 Replacing the Power Supply 37 Chapter 3 System Appearance 38 3-1 Front View...38 3-2 Rear View...39 3-3 Front Panel LED and...
...2-1 Removing Chassis Cover 16 2-2 Removing and Installing the Fan Duct 17 2-3 Installing the CPU 18 2-4 Installing the Heat Sink 19 2-5 Installing the Memory 21 2-5-1 Triple Channel Memory Configuration 21 2-5-2 Installing a Memory 22 2-6 Installing the PCI Expansion Card 23 2-6-1 Installing Add-on Card (MNXE2/MEZZ_2/Optional 28 2-6-2 Installing Add-on Card (MLIZS/MEZZ_2/Optional 29 2-7 Installing the Hard Disk Drive 31 2-8 Replacing the FAN Assemblly 32 2-9 Replacing the Power Supply 37 Chapter 3 System Appearance 38 3-1 Front View...38 3-2 Rear View...39 3-3 Front Panel LED and...
Manual
Page 8
Retain all safety and operating instructions for future use this product near water or a heat source.* Set up your computer has a voltage selector switch, make adjustments, or perform procedures on a laser device other than those specified in the documentation before opening a product enclosure, touching or installing internalcompo- The equipment grounding should be operated only from the type of power source indicated on the rating label...
Retain all safety and operating instructions for future use this product near water or a heat source.* Set up your computer has a voltage selector switch, make adjustments, or perform procedures on a laser device other than those specified in the documentation before opening a product enclosure, touching or installing internalcompo- The equipment grounding should be operated only from the type of power source indicated on the rating label...
Manual
Page 12
...; 1 x PCI Express x8 slot, running at x8 (Gen3/MEZZ_2/Proprietary slot) ASPEED® AST2400 supports 16MB DDR3 VRAM 8 x 2.5" Hot-Swap SATA HDDs Support for Intel IRSTe SATA RAID 0, RAID 1, RAID 5, RAID 10 System Fans USB Internal Connectors 8 x 80x80x38mm 15000rpm Up to 4 USB 3.0 ports (2 on the back panel, 2 additional ports via the USB brackets connected to the internal USB headers) 1 x 18-pin main power connector ...
...; 1 x PCI Express x8 slot, running at x8 (Gen3/MEZZ_2/Proprietary slot) ASPEED® AST2400 supports 16MB DDR3 VRAM 8 x 2.5" Hot-Swap SATA HDDs Support for Intel IRSTe SATA RAID 0, RAID 1, RAID 5, RAID 10 System Fans USB Internal Connectors 8 x 80x80x38mm 15000rpm Up to 4 USB 3.0 ports (2 on the back panel, 2 additional ports via the USB brackets connected to the internal USB headers) 1 x 18-pin main power connector ...
Manual
Page 13
Hardware Installation - 13 - Rear Panel I/O Front Panel LED/Buttons I/O Controller Hardware Monitor BIOS Environment Ambient Temperature 2 x USB 2.0/3.0 ports 2 x 10G SFP+ LAN ports 1 x 10/100/1000 dedicated management LAN port 1 x Serial port 1 x VGA port 1 x Power switch button 1 x ID switch button 1 x Reset button 1 x NMI button 1 x System status LED 2 x LAN Link/Active LED/1G/10G Speed LED (LAN1/LAN2) 1 x Power button/LED ...
Hardware Installation - 13 - Rear Panel I/O Front Panel LED/Buttons I/O Controller Hardware Monitor BIOS Environment Ambient Temperature 2 x USB 2.0/3.0 ports 2 x 10G SFP+ LAN ports 1 x 10/100/1000 dedicated management LAN port 1 x Serial port 1 x VGA port 1 x Power switch button 1 x ID switch button 1 x Reset button 1 x NMI button 1 x System status LED 2 x LAN Link/Active LED/1G/10G Speed LED (LAN1/LAN2) 1 x Power button/LED ...
Manual
Page 42
.../Utility Spec. (*2) Blink cycle depend on Back Panel) RAID configuration (via HBA, PCH) Disk LED (LED on Back Panel) Removed HDD Slot (LED on HDD's activity signal. (*3) If HDD is pulled out during rebuilding, Disk status of this HDD is regarded as fault. (*4) Blink frequncy about : 2 Hz - 42 - HDD Present (No Access) Off Off ----Off Off ----- Hardware Installation 3-5 Hard Disk Drive LEDs LED RAID No RAID configuration (via HW RAID Card or SW RAID Card) Disk LED Removed HDD Slot (Back Panel) Color Green Amber Green Amber Green Amber Green Amber Locate...
.../Utility Spec. (*2) Blink cycle depend on Back Panel) RAID configuration (via HBA, PCH) Disk LED (LED on Back Panel) Removed HDD Slot (LED on HDD's activity signal. (*3) If HDD is pulled out during rebuilding, Disk status of this HDD is regarded as fault. (*4) Blink frequncy about : 2 Hz - 42 - HDD Present (No Access) Off Off ----Off Off ----- Hardware Installation 3-5 Hard Disk Drive LEDs LED RAID No RAID configuration (via HW RAID Card or SW RAID Card) Disk LED Removed HDD Slot (Back Panel) Color Green Amber Green Amber Green Amber Green Amber Locate...
Manual
Page 45
... Front serial port header IPMB connector Rear serial port Power button/LED ID switch button Mezzine slot 2 (x8 slot/Proprietary/Running at x8) Reset button (top)/NMI button (buttom) System status LED LAN1 Active/Link (top)/Speed (buttom)LEDs Dual SFP+ LAN ports 13 LED_LAN2 LAN2 Active/Link (top)/Speed (buttom)LEDs 14 USB3_MLAN 15 SSATA_SGP 16 SSATA0/1/2/3 17 FP_1 18 SATA_SGP 19 SATA0/1/2/3/4/5 20 ATX1_2 21 F_USB3 22 ATX1_1 23 DIMM_P0_A0 24 DIMM_P0_A1 25 DIMM_P0_A2 BMC management LAN port (top)/USB 3.0 ports (buttom...
... Front serial port header IPMB connector Rear serial port Power button/LED ID switch button Mezzine slot 2 (x8 slot/Proprietary/Running at x8) Reset button (top)/NMI button (buttom) System status LED LAN1 Active/Link (top)/Speed (buttom)LEDs Dual SFP+ LAN ports 13 LED_LAN2 LAN2 Active/Link (top)/Speed (buttom)LEDs 14 USB3_MLAN 15 SSATA_SGP 16 SSATA0/1/2/3 17 FP_1 18 SATA_SGP 19 SATA0/1/2/3/4/5 20 ATX1_2 21 F_USB3 22 ATX1_1 23 DIMM_P0_A0 24 DIMM_P0_A1 25 DIMM_P0_A2 BMC management LAN port (top)/USB 3.0 ports (buttom...
Manual
Page 48
... to Stop FRB Timer Jumper) 1-2 Close: Normal operation (Default setting) 2-3 Close: Force to BMC. (Default setting) 2. ME_RCVR (ME Recovery Jumper) 1-2 Close: Normal operation (Default setting) 2-3 Close: ME recovery mode. ME_UPDATE (ME recovery Jumper) 1-2 Close: ME recovery mode. 2-3 Close: Normal operation. (Default setting) Hardware Installation - 48 - CLR_CMOS 1-2 Close: Normal operation (Default setting) (Clearing CMOS Jumper) 2-3 Close: Clear CMOS data 3. Jumper Code PMBUS_SEL 1. (PMBus Power Select Jumper) Jumper Setting 1-2 Close: PMBus connects to PCH. 2-3 Close...
... to Stop FRB Timer Jumper) 1-2 Close: Normal operation (Default setting) 2-3 Close: Force to BMC. (Default setting) 2. ME_RCVR (ME Recovery Jumper) 1-2 Close: Normal operation (Default setting) 2-3 Close: ME recovery mode. ME_UPDATE (ME recovery Jumper) 1-2 Close: ME recovery mode. 2-3 Close: Normal operation. (Default setting) Hardware Installation - 48 - CLR_CMOS 1-2 Close: Normal operation (Default setting) (Clearing CMOS Jumper) 2-3 Close: Clear CMOS data 3. Jumper Code PMBUS_SEL 1. (PMBus Power Select Jumper) Jumper Setting 1-2 Close: PMBus connects to PCH. 2-3 Close...
Manual
Page 50
... the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) Intel RC Setup This setup page includes all the submenu options for configuration of processor, network, North Bridge, South Bridge, and System event logs. Server Management Server additional features enabled/disabled setup menus. Security Change, set, or disable supervisor and user password. Configuration supervisor password allows you to make changes. Boot This setup page provides items for...
... the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) Intel RC Setup This setup page includes all the submenu options for configuration of processor, network, North Bridge, South Bridge, and System event logs. Server Management Server additional features enabled/disabled setup menus. Security Change, set, or disable supervisor and user password. Configuration supervisor password allows you to make changes. Boot This setup page provides items for...
Manual
Page 76
...Disabled. Options available: Enabled/Disabled. Default setting is Disabled. Options available: Enabled/Disabled. BIOS Setup - 76 - Options available: Enabled/Disabled. Execute Disable Bit When enabled, the processor prevents the execution of next L1 Data line based upon multiple loads in pairs. Enable Intel TXT Support Enable/Disable Intel Trusted Execution Technology support function. Options available: Enabled/Disabled. Options available: Enabled/Disabled. DCU IP Prefetch Enable prefetch of code in any memory area. Default setting is enabled, multi-threaded software...
...Disabled. Options available: Enabled/Disabled. Default setting is Disabled. Options available: Enabled/Disabled. BIOS Setup - 76 - Options available: Enabled/Disabled. Execute Disable Bit When enabled, the processor prevents the execution of next L1 Data line based upon multiple loads in pairs. Enable Intel TXT Support Enable/Disable Intel Trusted Execution Technology support function. Options available: Enabled/Disabled. Options available: Enabled/Disabled. DCU IP Prefetch Enable prefetch of code in any memory area. Default setting is enabled, multi-threaded software...
Manual
Page 87
.../Disabled/Enabled. Default setting is Enabled. BIOS Setup 5-3-5 Memory Configuration Integrated Memory Controller (iMC) Enforce POR Enable to enforce POR restrictions for configuration of advanced items. Memory Map Press [Enter] for DDR4 frequency and voltage programming. Memory Topology Press [Enter] for configuration of advanced items. Memory Thermal Press [Enter] for configuration of advanced items. - 87 - Options available: Auto/1333/1400/1600/1800/1867/2000/2133. Default setting is Auto. ECC Support Options...
.../Disabled/Enabled. Default setting is Enabled. BIOS Setup 5-3-5 Memory Configuration Integrated Memory Controller (iMC) Enforce POR Enable to enforce POR restrictions for configuration of advanced items. Memory Map Press [Enter] for DDR4 frequency and voltage programming. Memory Topology Press [Enter] for configuration of advanced items. Memory Thermal Press [Enter] for configuration of advanced items. - 87 - Options available: Auto/1333/1400/1600/1800/1867/2000/2133. Default setting is Auto. ECC Support Options...
Manual
Page 91
5-3-5-3 Memory Map Socket Interleave Below 4GB Splits the 0-4GB address space between two sockets, so that both sockets get a chunk of local memory below 4GB. BIOS Setup Default setting is Disabled. Rank Interleaving Options available: Auto/1-way Interleave/2-way Interleave/4-way Interleave/8-way Interleave. Default setting is Auto. - 91 - Default setting is Auto. Channel Interleaving Options available: Auto/1-way Interleave/2-way Interleave/3-way Interleave/4-way Interleave. Options available: Disabled/Enabled.
5-3-5-3 Memory Map Socket Interleave Below 4GB Splits the 0-4GB address space between two sockets, so that both sockets get a chunk of local memory below 4GB. BIOS Setup Default setting is Disabled. Rank Interleaving Options available: Auto/1-way Interleave/2-way Interleave/4-way Interleave/8-way Interleave. Default setting is Auto. - 91 - Default setting is Auto. Channel Interleaving Options available: Auto/1-way Interleave/2-way Interleave/3-way Interleave/4-way Interleave. Options available: Disabled/Enabled.
Manual
Page 92
When this item is Disabled. Default setting is set to increase or decrease the desired values. Default setting is Disabled. Default setting is Disabled. Correctable Error Threshold Press / keys to enabled, Sparing will be selected. BIOS Setup - 92 - Enabling Sparing and Mirroring is not supported. Lockstep Rank Sparing Options available: Auto/Disabled/Enabled. 5-3-5-4 Memory RAS Configuration RAS Mode Enable/Disable RAS modes. Options available: Disable/Mirror/Lockstep Mode. Lockstep x4 DIMMs Options available: Auto/Disabled/Enabled.
When this item is Disabled. Default setting is set to increase or decrease the desired values. Default setting is Disabled. Default setting is Disabled. Correctable Error Threshold Press / keys to enabled, Sparing will be selected. BIOS Setup - 92 - Enabling Sparing and Mirroring is not supported. Lockstep Rank Sparing Options available: Auto/Disabled/Enabled. 5-3-5-4 Memory RAS Configuration RAS Mode Enable/Disable RAS modes. Options available: Disable/Mirror/Lockstep Mode. Lockstep x4 DIMMs Options available: Auto/Disabled/Enabled.
Manual
Page 111
S/W Error Injection Support Enable/Disable software injection error logging function. Options available: Enabled/Disabled. Options available: Enabled/Disabled. Whea Settings Press [Enter] for configuration of advanced items. Memory Error Enabling Press [Enter] for configuration of advanced items. PCI/PCI Error Enabling Press [Enter] for configuration of advanced items. BIOS Setup - 111 - Default setting is Enabled. 5-3-10 Runtime Error Logging Runtime Error Logging System Errors Enable/Disable system error logging function. Default setting is Enabled.
S/W Error Injection Support Enable/Disable software injection error logging function. Options available: Enabled/Disabled. Options available: Enabled/Disabled. Whea Settings Press [Enter] for configuration of advanced items. Memory Error Enabling Press [Enter] for configuration of advanced items. PCI/PCI Error Enabling Press [Enter] for configuration of advanced items. BIOS Setup - 111 - Default setting is Enabled. 5-3-10 Runtime Error Logging Runtime Error Logging System Errors Enable/Disable system error logging function. Default setting is Enabled.
Manual
Page 112
BIOS Setup 5-3-10-1 Whea Setting WHEA Support (Windows Hardware Error Architecture) Enable/Disable WHEA Support. Options available: Enabled/Disabled. Default setting is Enabled. - 112 -
BIOS Setup 5-3-10-1 Whea Setting WHEA Support (Windows Hardware Error Architecture) Enable/Disable WHEA Support. Options available: Enabled/Disabled. Default setting is Enabled. - 112 -