Manual/User Guide
Page 4
... Commands-2 Standards Institute (SPC-2) (ANSI) American National Standard for American National Information Systems-Small Computer Standards Institute System Interface - 2(SCSI-2) (ANSI) COMMON COMMAND SET (CCS) of products covered by this manual comply with the following standards. ANSI X3.131-1986 ANSI X3....131-1994 X3T9.2/85-52 Rev 4.B X3T9.2/855D Rev 12 T10/1236-D Rev 12 ANSI NCITS 306-199x X3T10/994D Rev 18 T10/1302D Rev 11 Name Enacting Organization American National Standard for American National Information Systems-Small Computer Standards Institute System Interface...
... Commands-2 Standards Institute (SPC-2) (ANSI) American National Standard for American National Information Systems-Small Computer Standards Institute System Interface - 2(SCSI-2) (ANSI) COMMON COMMAND SET (CCS) of products covered by this manual comply with the following standards. ANSI X3.131-1986 ANSI X3....131-1994 X3T9.2/85-52 Rev 4.B X3T9.2/855D Rev 12 T10/1236-D Rev 12 ANSI NCITS 306-199x X3T10/994D Rev 18 T10/1302D Rev 11 Name Enacting Organization American National Standard for American National Information Systems-Small Computer Standards Institute System Interface...
Manual/User Guide
Page 5
..., and maintenance of the disk, the address method, and what to install MAN series disk drives. PREFACE This manual describes the MAN3735MC/MP, MAN3367MC/MP, MAN3184MC/MP (hereafter, MAN series), 3.5 type fixed disk drives with an embedded SCSI controller. The need arises, use in details how collect the information for setting device number and...
..., and maintenance of the disk, the address method, and what to install MAN series disk drives. PREFACE This manual describes the MAN3735MC/MP, MAN3367MC/MP, MAN3184MC/MP (hereafter, MAN series), 3.5 type fixed disk drives with an embedded SCSI controller. The need arises, use in details how collect the information for setting device number and...
Manual/User Guide
Page 6
... setting terminals and connectors, a list of setting items, the signal assignments of interface connectors, lists of the SCSI interface between host system and disk drive, the data formatted at the factory and device type. CAUTION CAUTION indicates that describes the electrical requirements of model... names and product numbers, and SCSI interface functions. WARNING WARNING indicates that personal injury will occur if the user...
... setting terminals and connectors, a list of setting items, the signal assignments of interface connectors, lists of the SCSI interface between host system and disk drive, the data formatted at the factory and device type. CAUTION CAUTION indicates that describes the electrical requirements of model... names and product numbers, and SCSI interface functions. WARNING WARNING indicates that personal injury will occur if the user...
Manual/User Guide
Page 7
Fujitsu is . These disk drives may be called intelligent disk drives (IDD), drives, or devices in this manual. The suffix of the model name of the disk drive varies depending on the electrical requirements, capacity, and data format at factory shipment of the SCSI, i.e., the interface for drive failures caused by misuse by the user, poor environmental conditions...
Fujitsu is . These disk drives may be called intelligent disk drives (IDD), drives, or devices in this manual. The suffix of the model name of the disk drive varies depending on the electrical requirements, capacity, and data format at factory shipment of the SCSI, i.e., the interface for drive failures caused by misuse by the user, poor environmental conditions...
Manual/User Guide
Page 8
...also indicates that system power is turned on .(except MC model) Damage 1. Hot temperature To prevent injury, do not handle the drive until after the device has 5-1 cooled sufficiently after turning off the power. Be careful of the insertion orientation of terminals except ... during operation and remain hot immediately after turning off before connecting or 5-11 disconnecting cables. 2. Do not change the setting of the SCSI connectors. 5-11 With the system in minor or moderate personal injury if the user does not perform the procedure correctly. Damage 1. However...
...also indicates that system power is turned on .(except MC model) Damage 1. Hot temperature To prevent injury, do not handle the drive until after the device has 5-1 cooled sufficiently after turning off the power. Be careful of the insertion orientation of terminals except ... during operation and remain hot immediately after turning off before connecting or 5-11 disconnecting cables. 2. Do not change the setting of the SCSI connectors. 5-11 With the system in minor or moderate personal injury if the user does not perform the procedure correctly. Damage 1. However...
Manual/User Guide
Page 9
...in the field because it is required to the disk drive, turn off before connecting or disconnecting a cable, connector, or plug. 3. Caution 6-5 1. Connect the ribbon cable to a cable connector with a colored line. Fujitsu does not assume responsibility if data is not provided. Caution... supplier may be blown or the cable may cause the damage to ground before handling. To connect SCSI devices, be burnt if overcurrent protection is destroyed during disk drive operation. 3. Data loss 6-4 When the SEND DIAGNOSTIC command terminates with a wrist strap connected to ...
...in the field because it is required to the disk drive, turn off before connecting or disconnecting a cable, connector, or plug. 3. Caution 6-5 1. Connect the ribbon cable to a cable connector with a colored line. Fujitsu does not assume responsibility if data is not provided. Caution... supplier may be blown or the cable may cause the damage to ground before handling. To connect SCSI devices, be burnt if overcurrent protection is destroyed during disk drive operation. 3. Data loss 6-4 When the SEND DIAGNOSTIC command terminates with a wrist strap connected to ...
Manual/User Guide
Page 10
Data Format 4. Diagnostics and Maintenance 7. SCSI Bus 2. SCSI Bus Error Recovery Processing SCSI Logical Interface Specifications 1. MANUAL ORGANIZATION PRODUCT/ MAINTENANCE MANUAL (This manual) 1. SCSI Message 3. Sense Data and error Recovery Procedure 5. Error Analysis 8. Data Buffer Management 3. Command Processing 2. General Description 2. Specifications 3. Installation Requirements 5. Installation 6. Principle of Operation SCSI Physical Interface Specifications 1. Command Specification 4. Disk Medium Management viii C141-E128-01EN
Data Format 4. Diagnostics and Maintenance 7. SCSI Bus 2. SCSI Bus Error Recovery Processing SCSI Logical Interface Specifications 1. MANUAL ORGANIZATION PRODUCT/ MAINTENANCE MANUAL (This manual) 1. SCSI Message 3. Sense Data and error Recovery Procedure 5. Error Analysis 8. Data Buffer Management 3. Command Processing 2. General Description 2. Specifications 3. Installation Requirements 5. Installation 6. Principle of Operation SCSI Physical Interface Specifications 1. Command Specification 4. Disk Medium Management viii C141-E128-01EN
Manual/User Guide
Page 11
...Standard Features ...1-2 1.2 Hardware Structure...1-5 1.3 System Configuration ...1-8 CHAPTER 2 SPECIFICATIONS 2-1 2.1 Hardware Specifications 2-1 2.1.1 Model name and part number 2-1 2.1.2 Function specifications ...2-2 2.1.3 Environmental specifications 2-4 2.1.4 Error rate...2-5 2.1.5 Reliability ...2-5 2.2 SCSI Function Specifications 2-7 CHAPTER 3 DATA FORMAT 3-1 3.1 Data Space ...3-1 3.1.1 Cylinder configuration...3-1 3.1.2 Alternate spare area ...3-4 3.1.3 Track format ...3-5 3.1.4 Sector format ...3-7 3.1.5 Format capacity ...3-9 3.2 Logical Data Block Addressing 3-10 3.3 Defect...
...Standard Features ...1-2 1.2 Hardware Structure...1-5 1.3 System Configuration ...1-8 CHAPTER 2 SPECIFICATIONS 2-1 2.1 Hardware Specifications 2-1 2.1.1 Model name and part number 2-1 2.1.2 Function specifications ...2-2 2.1.3 Environmental specifications 2-4 2.1.4 Error rate...2-5 2.1.5 Reliability ...2-5 2.2 SCSI Function Specifications 2-7 CHAPTER 3 DATA FORMAT 3-1 3.1 Data Space ...3-1 3.1.1 Cylinder configuration...3-1 3.1.2 Alternate spare area ...3-4 3.1.3 Track format ...3-5 3.1.4 Sector format ...3-7 3.1.5 Format capacity ...3-9 3.2 Logical Data Block Addressing 3-10 3.3 Defect...
Manual/User Guide
Page 12
... Mounting procedures...5-10 5.5 Connecting Cables...5-11 5.6 Confirming Operations after Installation and Preparation for use 5-12 5.6.1 Confirming initial operations 5-12 5.6.2 Checking SCSI connection 5-13 5.6.3 Formatting ...5-16 5.6.4 Setting parameters ...5-18 5.7 Dismounting Drives...5-22 5.8 Spare Disk Drive ...5-22 CHAPTER 6 DIAGNOSTICS AND MAINTENANCE 6-1 6.1 Diagnostics ...6-1 6.1.1 Self-diagnostics ...6-1 6.1.2 Test programs ...6-4 6.2 Maintenance Information 6-5 6.2.1 Precautions ...6-5 6.2.2 Maintenance requirements 6-6 6.2.3 Maintenance levels ...6-8 6.2.4 Revision numbers...
... Mounting procedures...5-10 5.5 Connecting Cables...5-11 5.6 Confirming Operations after Installation and Preparation for use 5-12 5.6.1 Confirming initial operations 5-12 5.6.2 Checking SCSI connection 5-13 5.6.3 Formatting ...5-16 5.6.4 Setting parameters ...5-18 5.7 Dismounting Drives...5-22 5.8 Spare Disk Drive ...5-22 CHAPTER 6 DIAGNOSTICS AND MAINTENANCE 6-1 6.1 Diagnostics ...6-1 6.1.1 Self-diagnostics ...6-1 6.1.2 Test programs ...6-4 6.2 Maintenance Information 6-5 6.2.1 Precautions ...6-5 6.2.2 Maintenance requirements 6-6 6.2.3 Maintenance levels ...6-8 6.2.4 Revision numbers...
Manual/User Guide
Page 13
......6-12 Diagnostic test ...6-12 Troubleshooting Procedures 6-13 Outline of troubleshooting procedures 6-13 Troubleshooting with disk drive replacement in the field 6-13 Troubleshooting at the repair site 6-15 Troubleshooting with parts replacement in... (5-2x-xx), (5-3D-00), (5-90-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00): SCSI interface error 7-4 CHAPTER 8 PRINCIPLE OF OPERATION 8-1 8.1 Outline ...8-1 8.2 Disk Drive Configuration 8-1 8.2.1 Disks ...8-2 8.2.2 Heads ...8-2 8.2.3 Spindle mechanism...8-2 8.2.4 Actuator ...8-2 8.2.5 Air filters ...8-2 8.3 Circuit Configuration...8-3...
......6-12 Diagnostic test ...6-12 Troubleshooting Procedures 6-13 Outline of troubleshooting procedures 6-13 Troubleshooting with disk drive replacement in the field 6-13 Troubleshooting at the repair site 6-15 Troubleshooting with parts replacement in... (5-2x-xx), (5-3D-00), (5-90-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00): SCSI interface error 7-4 CHAPTER 8 PRINCIPLE OF OPERATION 8-1 8.1 Outline ...8-1 8.2 Disk Drive Configuration 8-1 8.2.1 Disks ...8-2 8.2.2 Heads ...8-2 8.2.3 Spindle mechanism...8-2 8.2.4 Actuator ...8-2 8.2.5 Air filters ...8-2 8.3 Circuit Configuration...8-3...
Manual/User Guide
Page 14
... Setting Terminals (MAN series MP model A-3 APPENDIX B SETTING TERMINALS B-1 B.1 Setting Terminals (MP model only B-2 APPENDIX C CONNECTOR SIGNAL ALLOCATION C-1 C.1 SCSI Connector Signal Allocation: SCA2 type LVD 16-bit SCSI C-2 C.2 SCSI Connector Signal Allocation: 68 pin type LVD 16-bit SCSI C-3 APPENDIX D MODEL NAMES AND PRODUCT NUMBERS D-1 D.1 Model Names and Product Numbers D-2 xii C141-E128-01EN
... Setting Terminals (MAN series MP model A-3 APPENDIX B SETTING TERMINALS B-1 B.1 Setting Terminals (MP model only B-2 APPENDIX C CONNECTOR SIGNAL ALLOCATION C-1 C.1 SCSI Connector Signal Allocation: SCA2 type LVD 16-bit SCSI C-2 C.2 SCSI Connector Signal Allocation: 68 pin type LVD 16-bit SCSI C-3 APPENDIX D MODEL NAMES AND PRODUCT NUMBERS D-1 D.1 Model Names and Product Numbers D-2 xii C141-E128-01EN
Manual/User Guide
Page 15
...noise filter (recommended 4-10 Figure 4.13 Connectors and terminals location (MP model 4-11 Figure 4.14 16-bit SCSI interface connector 4-11 Figure 4.15 Power supply connector (16-bit SCSI model 4-12 Figure 4.16 External operator panel connector (CN1 4-13 Figure 4.17 External operator panel connector (...CN2 4-14 Figure 4.18 16-bit SCSI ID external input 4-15 Figure 4.19 Output signal for external LED 4-17 Figure 4.20 SCSI cables connection...4-18 Figure 4.21 ...
...noise filter (recommended 4-10 Figure 4.13 Connectors and terminals location (MP model 4-11 Figure 4.14 16-bit SCSI interface connector 4-11 Figure 4.15 Power supply connector (16-bit SCSI model 4-12 Figure 4.16 External operator panel connector (CN1 4-13 Figure 4.17 External operator panel connector (...CN2 4-14 Figure 4.18 16-bit SCSI ID external input 4-15 Figure 4.19 Output signal for external LED 4-17 Figure 4.20 SCSI cables connection...4-18 Figure 4.21 ...
Manual/User Guide
Page 16
... connections (2 of 2 5-4 Figure 5.2 IDD setting terminals position 5-5 Figure 5.3 Setting terminals (CN2 MP model only 5-6 Figure 5.4 Checking the SCSI connection (A 5-14 Figure 5.5 Checking the SCSI connection (B 5-15 Figure 6.1 Revision label...6-9 Figure 6.2 Indicating revision numbers 6-10 Figure 6.3 Test flowchart ...6-11 Figure 7.1 Format of extended sense data 7-2 Figure 8.1 Circuit configuration ...8-4 Figure 8.2 IDD ...
... connections (2 of 2 5-4 Figure 5.2 IDD setting terminals position 5-5 Figure 5.3 Setting terminals (CN2 MP model only 5-6 Figure 5.4 Checking the SCSI connection (A 5-14 Figure 5.5 Checking the SCSI connection (B 5-15 Figure 6.1 Revision label...6-9 Figure 6.2 Indicating revision numbers 6-10 Figure 6.3 Test flowchart ...6-11 Figure 7.1 Format of extended sense data 7-2 Figure 8.1 Circuit configuration ...8-4 Figure 8.2 IDD ...
Manual/User Guide
Page 17
... 6.1 Self-diagnostic functions...6-1 Table 6.2 System-level field troubleshooting 6-14 Table 6.3 Disk drive troubleshooting...6-15 Table 7.1 Definition of sense data...7-3 Table B.1 Setting terminal: CN2 ...B-2 Table C.1 SCSI connector (SCA2 type LVD 16-bit SCSI): CN1 C-2 Table C.2 SCSI connector (68 pin type LVD 16-bit SCSI): CN1 C-3 Table D.1 MAN series model names and product numbers D-2 C141-E128-01EN...
... 6.1 Self-diagnostic functions...6-1 Table 6.2 System-level field troubleshooting 6-14 Table 6.3 Disk drive troubleshooting...6-15 Table 7.1 Definition of sense data...7-3 Table B.1 Setting terminal: CN2 ...B-2 Table C.1 SCSI connector (SCA2 type LVD 16-bit SCSI): CN1 C-2 Table C.2 SCSI connector (68 pin type LVD 16-bit SCSI): CN1 C-3 Table D.1 MAN series model names and product numbers D-2 C141-E128-01EN...
Manual/User Guide
Page 19
... describes the feature and configuration of the IDD, allow the user to SCSI Logical Interface Specifications for details. IDDs are high performance large capacity 3.5 type fixed disk drives with large storage capacity. C141-E128-01EN 1 - 1 The flexibility and expandability of the SCSI, as well as the powerful command set of the intelligent disk...
... describes the feature and configuration of the IDD, allow the user to SCSI Logical Interface Specifications for details. IDDs are high performance large capacity 3.5 type fixed disk drives with large storage capacity. C141-E128-01EN 1 - 1 The flexibility and expandability of the SCSI, as well as the powerful command set of the intelligent disk...
Manual/User Guide
Page 20
...manipulate data through logical block addressing regardless of the physical characteristics of the disk drive. For the ultra SCSI model, number of the host system. (2) SCSI/CCS standard The IDD provides not only SCSI basic functions but also the following features: • Arbitration • Disconnection/.... (3) 8-bit SCSI/16-bit SCSI The IDD has 16-bit data bus width (16-bit SCSI), which meets the logical specification of the SCSI CCS (Common Command Set for SCSI-2. This is also available as follows. • 8-bit SCSI: 8 drives max. • 16-bit SCSI: 16 drives max. (4) High...
...manipulate data through logical block addressing regardless of the physical characteristics of the disk drive. For the ultra SCSI model, number of the host system. (2) SCSI/CCS standard The IDD provides not only SCSI basic functions but also the following features: • Arbitration • Disconnection/.... (3) 8-bit SCSI/16-bit SCSI The IDD has 16-bit data bus width (16-bit SCSI), which meets the logical specification of the SCSI CCS (Common Command Set for SCSI-2. This is also available as follows. • 8-bit SCSI: 8 drives max. • 16-bit SCSI: 16 drives max. (4) High...
Manual/User Guide
Page 21
... the data buffer, the initiator can perform the effective input/output operations with utilizing high data transfer capability of the SCSI bus regardless of actual data transfer rate of the disk drive. (7) Read-ahead cache feature After executing the READ command, the IDD reads automatically and stores (prefetches) the subsequent data blocks...
... the data buffer, the initiator can perform the effective input/output operations with utilizing high data transfer capability of the SCSI bus regardless of actual data transfer rate of the disk drive. (7) Read-ahead cache feature After executing the READ command, the IDD reads automatically and stores (prefetches) the subsequent data blocks...
Manual/User Guide
Page 22
... slipping the defective data block at initializing with large capacity can be obtained from errors in SCSI bus or the disk drive using its alternate data block. (12) Programmable data block length Data can be accessed in fixed-block length units. The data block...logical data block can start and stop the spindle motor. (17) Diagnosis The IDD has a diagnostic capability which checks internal controller functions and drive operations to the initiator after being corrected in a physical sequence by dividing all cylinders into several partitions and changing the recording density on each ...
... slipping the defective data block at initializing with large capacity can be obtained from errors in SCSI bus or the disk drive using its alternate data block. (12) Programmable data block length Data can be accessed in fixed-block length units. The data block...logical data block can start and stop the spindle motor. (17) Diagnosis The IDD has a diagnostic capability which checks internal controller functions and drive operations to the initiator after being corrected in a physical sequence by dividing all cylinders into several partitions and changing the recording density on each ...
Manual/User Guide
Page 26
... Controller circuit The controller circuit uses LSIs to increase the reliability and uses a high speed microprocessing unit (MPU) to the SCSI bus of the SCSI controller. 1.3 System Configuration Figure 1.4 shows the system configuration. SCSI bus Figure 1.4 System configuration 1 - 8 C141-E128-01EN The IDDs are connected to increase the performance of host systems and... transmission and an MEEPR4ML (Modified Enhanced Extended Partial Response Class 4 Maximum Likelihood) modulation/demodulation circuit in order to prevent errors being triggered by SCSI devices which operate as target.
... Controller circuit The controller circuit uses LSIs to increase the reliability and uses a high speed microprocessing unit (MPU) to the SCSI bus of the SCSI controller. 1.3 System Configuration Figure 1.4 shows the system configuration. SCSI bus Figure 1.4 System configuration 1 - 8 C141-E128-01EN The IDDs are connected to increase the performance of host systems and... transmission and an MEEPR4ML (Modified Enhanced Extended Partial Response Class 4 Maximum Likelihood) modulation/demodulation circuit in order to prevent errors being triggered by SCSI devices which operate as target.
Manual/User Guide
Page 27
...the LUN to select the peripheral device for input/output operation. The initiator selects one SCSI device by specifying that operates as target is a single logical unit, the selectable number of disk drive is addressed in unit called as logical unit. For example, the system can be ...configured as multi-host system on the bus has its own unique address (SCSI ID:#n in Figure 1.4). A unique address (LUN: logical unit ...
...the LUN to select the peripheral device for input/output operation. The initiator selects one SCSI device by specifying that operates as target is a single logical unit, the selectable number of disk drive is addressed in unit called as logical unit. For example, the system can be ...configured as multi-host system on the bus has its own unique address (SCSI ID:#n in Figure 1.4). A unique address (LUN: logical unit ...