All product names are subject to change without notice. All rights reserved. Specifications are trademarks of their respective companies. Ti200, Ti300, Ti400, Ti450 Thermal Imagers Users Manual September 2013, Rev. 2, 3/16 © 2013-2016 Fluke Corporation.
All product names are subject to change without notice. All rights reserved. Specifications are trademarks of their respective companies. Ti200, Ti300, Ti400, Ti450 Thermal Imagers Users Manual September 2013, Rev. 2, 3/16 © 2013-2016 Fluke Corporation.
User Manual
Page 4
...Distance 40 Zoom (Ti450 41 Camera Menu 42 LaserSharp Auto Focus System 42 Backlight 43 Torch 43 Video 43 Auto Capture 44 Wireless 45 Memory Menu 49 Review Image Files 49 Delete Image Files 49 Fluke Connect Wireless System 50 Fluke Connect App 50 Fluke Connect Tools 51 ...Settings 56 Streaming Video (Remote Display 57 Stream Live to a PC 57 Stream Live with Fluke Connect Software 58 Stream Live to an HDMI Device 58 Remote Control (Ti400 and Ti450 59 Maintenance 59 How to Clean the Case 60 Battery Care 60 General Specifications 61 Detailed ...
...Distance 40 Zoom (Ti450 41 Camera Menu 42 LaserSharp Auto Focus System 42 Backlight 43 Torch 43 Video 43 Auto Capture 44 Wireless 45 Memory Menu 49 Review Image Files 49 Delete Image Files 49 Fluke Connect Wireless System 50 Fluke Connect App 50 Fluke Connect Tools 51 ...Settings 56 Streaming Video (Remote Display 57 Stream Live to a PC 57 Stream Live with Fluke Connect Software 58 Stream Live to an HDMI Device 58 Remote Control (Ti400 and Ti450 59 Maintenance 59 How to Clean the Case 60 Battery Care 60 General Specifications 61 Detailed ...
User Manual
Page 5
...troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development. The Imager includes SmartView software. All Imagers have the Fluke LaserSharp Auto Focus System, as well as advanced manual focus capabilities. A rugged, rechargeable lithium-ion smart battery provides power to... and functions associated with IR-Fusion® technology with the included AC power adapter. Introduction The Fluke Ti200, Ti300, Ti400, and Ti450 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use on mobile devices. The...
...troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development. The Imager includes SmartView software. All Imagers have the Fluke LaserSharp Auto Focus System, as well as advanced manual focus capabilities. A rugged, rechargeable lithium-ion smart battery provides power to... and functions associated with IR-Fusion® technology with the included AC power adapter. Introduction The Fluke Ti200, Ti300, Ti400, and Ti450 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use on mobile devices. The...
User Manual
Page 6
...WiFi connectivity • Streaming video • Remote control and operation (Ti400 and Ti450 only) How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • USA: 1-800-760-4523 • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • ...-3-6714-3114 • Singapore: +65-6799-5566 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 To register your Product, visit http://register...
...WiFi connectivity • Streaming video • Remote control and operation (Ti400 and Ti450 only) How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • USA: 1-800-760-4523 • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • ...-3-6714-3114 • Singapore: +65-6799-5566 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 To register your Product, visit http://register...
User Manual
Page 10
Ti200, Ti300, Ti400,Ti450 Users Manual Radio Frequency Data See Imager Information for instructions on the Imager. Accessories Model Description FLK-TI-SBP3 Smart Battery Pack FLK-TI-SBC3B ... on how to install a lens. 6 See Figures 2 and 3 for your infrared inspection work. To view the Radio Frequency Data Class B Instruction Sheet, visit http://us.fluke.com/usen/support/manuals and search for PN 4409209.
Ti200, Ti300, Ti400,Ti450 Users Manual Radio Frequency Data See Imager Information for instructions on the Imager. Accessories Model Description FLK-TI-SBP3 Smart Battery Pack FLK-TI-SBC3B ... on how to install a lens. 6 See Figures 2 and 3 for your infrared inspection work. To view the Radio Frequency Data Class B Instruction Sheet, visit http://us.fluke.com/usen/support/manuals and search for PN 4409209.
User Manual
Page 16
... Imager and appears on the Imager. 2. Enable the Radio In countries with the Imager. Go to http://fluke.com/register/ti. 3. Go to Fluke Connect on the SmartView software toolbar menu. 3. Select Yes. 4. Ti200, Ti300, Ti400,Ti450 Users Manual Download Firmware 1. Open SmartView software on the Imager. Connect the USB A connector end of...
... Imager and appears on the Imager. 2. Enable the Radio In countries with the Imager. Go to http://fluke.com/register/ti. 3. Go to Fluke Connect on the SmartView software toolbar menu. 3. Select Yes. 4. Ti200, Ti300, Ti400,Ti450 Users Manual Download Firmware 1. Open SmartView software on the Imager. Connect the USB A connector end of...
User Manual
Page 22
... Manual Focus The Imager uses the LaserSharp Auto Focus System and an advanced manual focus system. The Ti450 also uses MultiSharp Focus. Correct focus makes sure that the infrared energy is easier to the infrared lens. If using AutoBlend Mode, the laser ... Note The user is aligned parallel to use the advanced manual focus as a manual override of the detector. The LaserSharp Auto Focus System, only from Fluke, uses a precisionadjusted and aligned laser pointer to locate the visible laser pointer on the object under inspection. Correct focus is in all imaging applications. See...
... Manual Focus The Imager uses the LaserSharp Auto Focus System and an advanced manual focus system. The Ti450 also uses MultiSharp Focus. Correct focus makes sure that the infrared energy is easier to the infrared lens. If using AutoBlend Mode, the laser ... Note The user is aligned parallel to use the advanced manual focus as a manual override of the detector. The LaserSharp Auto Focus System, only from Fluke, uses a precisionadjusted and aligned laser pointer to locate the visible laser pointer on the object under inspection. Correct focus is in all imaging applications. See...
User Manual
Page 24
... the access for thermal image display, camera features, measurement, advanced functions, memory review, and settings for Measurement, Image, Camera, Memory, Fluke Connect, and Settings. To open until you can choose to save the image or pull the primary trigger again or to cancel... edit the image. Pull and release the primary trigger. Push to cycle through the secondary menus. Ti200, Ti300, Ti400,Ti450 Users Manual How to that button throughout all menu screens. Note MultiSharp Focus captures and freezes images differently. The primary menu shows secondary...
... the access for thermal image display, camera features, measurement, advanced functions, memory review, and settings for Measurement, Image, Camera, Memory, Fluke Connect, and Settings. To open until you can choose to save the image or pull the primary trigger again or to cancel... edit the image. Pull and release the primary trigger. Push to cycle through the secondary menus. Ti200, Ti300, Ti400,Ti450 Users Manual How to that button throughout all menu screens. Note MultiSharp Focus captures and freezes images differently. The primary menu shows secondary...
User Manual
Page 44
... ∼18 seconds. You can choose to 30 meters, the distance from your PC. The laser warning symbol (*) shows in imperial or metric units. Logo A Fluke logo shows on the display in the Header zone of the image. Push / to create a 640 x 480 image. Distance The Imager has a laser... measures, up to turn off the logo: 1. The distance is not processed on the Imager so you pull the secondary trigger. 40 Ti200, Ti300, Ti400,Ti450 Users Manual SuperResolution SuperResolution uses a 320 x 240 sensor to capture micro movements to highlight On or Off. 3.
... ∼18 seconds. You can choose to 30 meters, the distance from your PC. The laser warning symbol (*) shows in imperial or metric units. Logo A Fluke logo shows on the display in the Header zone of the image. Push / to create a 640 x 480 image. Distance The Imager has a laser... measures, up to turn off the logo: 1. The distance is not processed on the Imager so you pull the secondary trigger. 40 Ti200, Ti300, Ti400,Ti450 Users Manual SuperResolution SuperResolution uses a 320 x 240 sensor to capture micro movements to highlight On or Off. 3.
User Manual
Page 50
... select a device. 5. Push / to highlight Settings. 46 See Stream Live to set the option. Push to a PC and Fluke Connect Wireless System for more information. Push / to connect/disconnect. 6. Push to highlight Off. 3. To change the settings... 1. Enter a password if you are prompted. Note WiFi for available Bluetooth devices within range of the camera. 4. Ti200, Ti300, Ti400,Ti450 Users Manual To use only in Kuwait, Chile, and United Arab Emirates. Go to highlight On. 3. Push / to Camera > Wireless ...
... select a device. 5. Push / to highlight Settings. 46 See Stream Live to set the option. Push to a PC and Fluke Connect Wireless System for more information. Push / to connect/disconnect. 6. Push to highlight Off. 3. To change the settings... 1. Enter a password if you are prompted. Note WiFi for available Bluetooth devices within range of the camera. 4. Ti200, Ti300, Ti400,Ti450 Users Manual To use only in Kuwait, Chile, and United Arab Emirates. Go to highlight On. 3. Push / to Camera > Wireless ...
User Manual
Page 52
...Instant Upload. Turn on the wireless feature on the tool. 2. Repeat steps 1 and 2 for available tools within range of the Imager. 7. To sign in the Fluke Cloud. Turn on the tool. 3. Push / to scan for each other. Push / to Camera > Wireless > CNX. 5. When you... account in to the security profiles on all devices due to your user name. 48 Enter your account: 1. Ti200, Ti300, Ti400,Ti450 Users Manual To discover a supported tool: 1. Note The Instant Upload feature may not work on different networks. Repeat steps 8 and 9 for the ...
...Instant Upload. Turn on the wireless feature on the tool. 2. Repeat steps 1 and 2 for available tools within range of the Imager. 7. To sign in the Fluke Cloud. Turn on the tool. 3. Push / to scan for each other. Push / to Camera > Wireless > CNX. 5. When you... account in to the security profiles on all devices due to your user name. 48 Enter your account: 1. Ti200, Ti300, Ti400,Ti450 Users Manual To discover a supported tool: 1. Note The Instant Upload feature may not work on different networks. Repeat steps 8 and 9 for the ...
User Manual
Page 54
...show images from your infrared camera on your team. Push to delete the file. The Fluke Connect system is available for you to continue or cancel. 5. Ti200, Ti300, Ti400,Ti450 Users Manual 3. Highlight All Images and push . Push again to delete all countries.... Push to Fluke Connect Mobile App > On. 3. The Imager prompts you to use the Fluke Connect App with an app on the Imager...
...show images from your infrared camera on your team. Push to delete the file. The Fluke Connect system is available for you to continue or cancel. 5. Ti200, Ti300, Ti400,Ti450 Users Manual 3. Highlight All Images and push . Push again to delete all countries.... Push to Fluke Connect Mobile App > On. 3. The Imager prompts you to use the Fluke Connect App with an app on the Imager...
User Manual
Page 62
... to an HDMI video device. 58 If you changed the name of the Imager, select the new name of the Imager. To stream live with Fluke Connect Software To stream live to use the Micro B jack on the Imager appears on the SmartView software toolbar menu. 4. Make sure to an ...Live to an HDMI Device HDMI (High-Definition Multimedia Interface) is the default name of the Imager from on the Imager. 2. Ti200, Ti300, Ti400,Ti450 Users Manual Note Some Imagers have both A and Micro B connector jacks. Choose Remote Display from the networks on the PC. Stream Live with...
... to an HDMI video device. 58 If you changed the name of the Imager, select the new name of the Imager. To stream live with Fluke Connect Software To stream live to use the Micro B jack on the Imager appears on the SmartView software toolbar menu. 4. Make sure to an ...Live to an HDMI Device HDMI (High-Definition Multimedia Interface) is the default name of the Imager from on the Imager. 2. Ti200, Ti300, Ti400,Ti450 Users Manual Note Some Imagers have both A and Micro B connector jacks. Choose Remote Display from the networks on the PC. Stream Live with...
User Manual
Page 63
... through an approved technical site. 59 In SmartView software, select SmartView (Camera is dangerous to Remote Control the Imager. 3. Set up the Fluke Connect system. The laser beam is the default selection). To remotely control the Imager with a PC: 1. You can control all of the...personal injury, do not open the Product. Select Yes. To remotely control the Imager with the Fluke Connect app: 1. Thermal Imagers Remote Control (Ti400 and Ti450) Remote Control (Ti400 and Ti450) The Imager can change the other menu items on the Imager directly on LaserSharp Auto Focus, ...
... through an approved technical site. 59 In SmartView software, select SmartView (Camera is dangerous to Remote Control the Imager. 3. Set up the Fluke Connect system. The laser beam is the default selection). To remotely control the Imager with a PC: 1. You can control all of the...personal injury, do not open the Product. Select Yes. To remotely control the Imager with the Fluke Connect app: 1. Thermal Imagers Remote Control (Ti400 and Ti450) Remote Control (Ti400 and Ti450) The Imager can change the other menu items on the Imager directly on LaserSharp Auto Focus, ...
User Manual
Page 64
... crush battery cells and battery packs. • Remove batteries to prevent battery leakage and damage to clean the case or lens/window. Ti200, Ti300, Ti400,Ti450 Users Manual How to charge the battery. • Keep cells and battery packs clean and dry. Batteries stored for long periods will self-discharge in... To prevent personal injury and for an extended period. • Connect the battery charger to the mains power outlet before the charger. • Use only Fluke approved power adapters to Clean the Case Clean the case with a dry, clean cloth.
... crush battery cells and battery packs. • Remove batteries to prevent battery leakage and damage to clean the case or lens/window. Ti200, Ti300, Ti400,Ti450 Users Manual How to charge the battery. • Keep cells and battery packs clean and dry. Batteries stored for long periods will self-discharge in... To prevent personal injury and for an extended period. • Connect the battery charger to the mains power outlet before the charger. • Use only Fluke approved power adapters to Clean the Case Clean the case with a dry, clean cloth.
User Manual
Page 70
... playback on PC USB, WiFi hotspot, or WiFi network Mobile Device Fluke Connect app with WiFi hotspot TV Monitor HDMI Remote Control Operation (Ti400 and Ti450 only SmartView software or Fluke Connect app. IR-PhotoNotes Annotations 5 images Text Annotation Yes Streaming Video... (Remote Display) SmartView Software on camera. Ti200, Ti300, Ti400,Ti450 Users Manual Video Recording Standard, Non-Radiometric...
... playback on PC USB, WiFi hotspot, or WiFi network Mobile Device Fluke Connect app with WiFi hotspot TV Monitor HDMI Remote Control Operation (Ti400 and Ti450 only SmartView software or Fluke Connect app. IR-PhotoNotes Annotations 5 images Text Annotation Yes Streaming Video... (Remote Display) SmartView Software on camera. Ti200, Ti300, Ti400,Ti450 Users Manual Video Recording Standard, Non-Radiometric...