Fluke 54-II-B Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 54-II-B manuals!
Problems with Fluke 54-II-B?

Ask a Question

Fluke 54-II-B Videos

Getting to know the Fluke 54-II-B Thermocouple Thermometer/Data Logger
Duration: 1:01
Total Views: 248
Pax Instruments T100-v0.1 vs Fluke 54 II B
Duration: 1:12
Total Views: 152
??? Fluke 54-II B ??????1
Duration: :59
Total Views: 28
??? Fluke 54-II B ??????2
Duration: :59
Total Views: 12

Popular Fluke 54-II-B Manual Pages

Product Manual - Page 1

53IIB/54IIB Thermometer Users Manual January 2011 © 2011 Fluke Corporation. Specifications are trademarks of their respective companies. All product names are subject to change without notice. MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664 All rights reserved.
Product Manual - Page 4

... 16 Clearing Memory...17 Viewing Logged Readings 17 Communicating with a PC 18 Maintenance ...19 Replacing the Batteries 19 Cleaning the Case and Holster 19 Calibration...19 Specifications ...19 Environmental ...19 80 PK-1 Thermocouple (supplied with thermometer 20 Electrical ...20 Replacement Parts and Accessories 21 ii MyFlukeStore Shop for Fluke products online at: www. .com 1.888...
Product Manual - Page 6

..., have the thermometer serviced. • Reflective objects result in lower than actual temperature measurements. To avoid electrical shock or personal injury, follow these guidelines: • Before using the thermometer inspect the case. Pay particular attention to the insulation around explosive gas, vapor, or dust. • Do not connect to the user. 53IIB/54IIB Users Manual Table...
Product Manual - Page 7

... of batteries. • Match the + and − polarities of the case or cover removed. 53IIB/54IIB Safety Information Table 1. Safety Information (cont.) W Warning (cont.) • Model 54: Measurement errors may damage the meter or the equipment under test. • Use the proper thermocouples, function, and range for Fluke products online at: www. .com 1.888.610.7664
Product Manual - Page 8

...• Table 5 describes the functions of the buttons. International Symbols W Refer to Models 53 and 54 unless otherwise indicated. To become familiar with the thermometer, study the following sections. 4 MyFlukeStore Shop for information about this Users Manual applies both to the manual for Fluke products online at: www. .com 1.888.610.7664 53IIB/54IIB Users Manual Table 2.
Product Manual - Page 10

... is in SETUP. Shows the INTERVAL length in progress.  Readings are displayed.  Low battery. Model 54: T1 or T2 reading.  The thermocouple type.  Time Display: 24-hour clock. Display Elements  The thermocouple measurement includes an offset. Replace the batteries.  Primary Display. 53IIB/54IIB Users Manual Display Elements...
Product Manual - Page 12

....") Press  to scroll to the Setup option you want to change . Press  to scroll to the Setup option you want to change . Press  to increase the displayed setting. 53IIB/54IIB Users Manual   Table 5. Press  to start or stop . 8 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664...
Product Manual - Page 14

... (3), 10 minutes (4), or user-defined You can select a logging interval of each logging interval. You can also set the logging interval manually (0). Each time you want appear on the display, and then press  to select. 4. 53IIB/54IIB Users Manual Changing the Logging Interval The logging interval determines how often the thermometer stores logged readings in memory. 1. Press...
Product Manual - Page 15

... selected thermocouple blinks. 3. Model 54: You can adjust the thermometer's readings to 0.0 when you change the offset setting. Press  to store the offset setting in memory. 53IIB/54IIB Changing Setup Options Changing the Offset You can store individual offsets for the errors of a specific thermocouple. Press  to indicate that you want to Adjust for Fluke products...
Product Manual - Page 16

...;. 2. Press  to set or shows 2. The left two digits blink. 3. Note Holding down  or  causes the number to store the time in MIN MAX and logging modes. 53IIB/54IIB Users Manual Enabling or Disabling Sleep Mode The thermometer enters sleep mode if no button press occurs for Fluke products online at: www. .com...
Product Manual - Page 18

... is outside the thermocouple's valid range. Hold or attach the thermocouple(s) to toggle showing the T1, T2, or T1-T2 readings in the selected display. 3. Model 54: Press  to the measurement location. The elapsed time since entering MIN MAX mode, or the time at : www. .com 1.888.610.7664 53IIB/54IIB Users Manual Displaying Temperatures 1. Press...
Product Manual - Page 20

...initial conditions when logging continuously. You can view these values by pressing  or using FlukeView Forms. The data entries are a time stamp, the T1 reading, and the T2 and T1-T2 readings (Model 54). Press  again to start logging. Set the logging interval. (See "Changing Setup Options.") 2. 53IIB/54IIB Users Manual Initial Conditions and Data Entries Logged readings include...
Product Manual - Page 22

...with FlukeView Forms. 18 MyFlukeStore Shop for Fluke products online at 1:49 P.M. The .... Note The thermometer calculates the minimum and maximum of the thermometer's memory to ...54IIB Users Manual 3. FlukeView Forms places the logged readings into standard (default) or customized forms. The forms also display user comments. Press  to the FlukeView Forms Installation Guide...
Product Manual - Page 24

53IIB/54IIB Users Manual General Weight Dimensions (without holster) Battery Certification Safety 280 g (10 oz) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) 3 AA batteries P, ) CAN/CSA C22.2 No. 61010-1-04, ANSI/UL 61010-1:2004, EN/IEC 61010-1:2001 EMC EN/IEC 61326-1:2006 CAT I OVERVOLTAGE (Installation) CATEGORY I, Pollution Degree 2 per IEC1010...
Product Manual - Page 25

...] Susceptibility: ±2 oC (±3.6 oF) for Fluke products online at: www. .com 1.888.610.7664 and 0.08 % of 1 year. Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual 1276123 FlukeView Forms FVF-SC2 21 MyFlukeStore...

Fluke 54-II-B Reviews

Do you have an experience with the Fluke 54-II-B that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 54-II-B Search Terms

The following terms are frequently used to search for Fluke 54-II-B support:

Ask a New Question
Use the box below to post a new question about Fluke 54-II-B.
Manuals / Documents
Download any of our Fluke 54-II-B manuals for free!

We have the following 1 documents available for the Fluke 54-II-B:
  • Product Manual
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 54-II-B manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 54-II-B user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.