Popular Fluke 902 FC Manual Pages
User Manual - Page 5
Introduction
The Fluke 902 FC is a hand-held battery-operated HVAC True-rms Clamp Meter (the Product) that measures: • AC current • DC current (up...;C) and Fahrenheit (°F) The Product comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated Temperature Probe (the Probe) •...
User Manual - Page 6
To register your product, visit http://register.fluke.com. 902 FC Users Manual
How to Contact Fluke
To contact Fluke: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-03-6714-3114 • Singapore...
User Manual - Page 8
...a Product, probe, or accessory.
• Comply with local and national safety codes. Examine the test leads for loose or weakened components. Also look for damaged ...where hazardous live conductors are damaged. 902 FC Users Manual
• Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of the clamp housing or output cable insulation. Carefully...
User Manual - Page 10
902 FC Users Manual
• When batteries are changed, ensure that the calibration seal in CAT III or CAT IV environments without the protective cap installed. If damaged, the Product may not be safe to use in the battery compartment is not damaged. Return the Product to The protective cap decreases the exposed probe metal to Fluke for replacement of the seal.
• Do not use .
User Manual - Page 12
....
Certified by TÜV SÜD Product Service. Do not dispose of the building's low-voltage MAINS installation.
Conforms to North American safety standards.
Conforms to the distribution part of this product is applicable to test and measuring circuits connected to relevant Australian EMC standards.
902 FC Users Manual
Symbol
P
...
User Manual - Page 14
902 FC Users Manual
Item
Table 2. Product Features
Description
Fluke Connect
Jaw release
Tactile barrier
Jaws
Hold button
Rotary switch:
AC and DC voltage
Resistance and continuity
DC microamps
Degrees Fahrenheit / ...
User Manual - Page 16
...
Beeper Display Hold is active Volts Fluke Connect is enabled Degrees (Farenheit or Celcius) Amps
Ohms Microamps Microfarads DC Direct Current AC Alternating Current
Use the Product
Measure AC and DC Voltage
1. 902 FC Users Manual
Table 3. Push to .
3. Turn the rotary switch...
User Manual - Page 18
Read the measured resistance on the display. Measure the resistance by touching the probes to the desired test points of the circuit.
4. Note
If the resistance is 902 FC Users Manual
3.
User Manual - Page 20
.... To measure temperature (see Figure 3): 1. 902 FC Users Manual
Measure Temperature
The Product measures temperature in either Celsius (°C) or Fahrenheit (°F). Turn the rotary switch to select °C or °F. Push to .
3.
Note To meet stated accuracy, the Product and plug of the probe.
2. Read the measured temperature on the display...
User Manual - Page 22
... Figure 4).
18 Turn the rotary switch to the circuit. 2. Turn the rotary switch to .
4. Center the wire within the clamp jaws below the horizontal line located on the clamp (see Figure 4). 902 FC Users Manual
Measure Capacitance
1. If the capacitor requires more discharging, diSC shows while the capacitor discharges.
Disconnect and discharge the capacitor.
...
User Manual - Page 24
When a new high or low is detected, the Product beeps. 902 FC Users Manual
Backlight
Push to toggle the backlight on and off after 2 minutes. The backlight automatically turns off . Turn the rotary switch to step through the minimum (MIN) and present readings. 4. Push to the desired measurement function. 2. Push . To pause...
User Manual - Page 26
... detergent.
22 Clean the Product
XW Warning To prevent possible electrical shock, fire, or personal injury, remove the input signals before you clean the Product.
902 FC Users Manual
Maintenance
XW Warning To prevent possible electrical shock, fire, or personal injury: • Have an approved technician repair the Product. • Use only specified replacement parts.
User Manual - Page 28
902 FC Users Manual
To replace the batteries (see Figure 5): 1. Remove the batteries. 5. Battery Replacement
iad12.eps
24 Turn the rotary switch to the case bottom and tighten the
fastener.
3
1
2
Figure 5. Replace the batteries with two new AA batteries. 6. Reattach the battery door to OFF. 2. Loosen the battery door fastener and remove the door from the terminals. 3. ...
User Manual - Page 30
902 FC Users Manual
Specifications
Electrical Specifications
Function
Voltage DC Voltage AC (True-rms)
Range 600 V 600 V
Current AC (True-rms)
600 A
Current DC Resistance Continuity Temperature Capacitance
200 μA 600 Ω 6000 Ω 60 kΩ 2 1.0 % ±5 counts
1.0 % ±5 counts
--
0.1 °C
1.0 % ±8 counts
0.1 μF 1 μF
1.0 % ±4 counts
26
User Manual - Page 32
There may be potential difficulties in ensuring electromagnetic
compatibility in all establishments other environments due to conducted and radiated disturbances. 902 FC Users Manual
Power Requirements
Two AA Batteries, IEC LR6
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Portable Electromagnetic Environment; Emissions that exceed the levels required by CISPR 11 ...