Fluke 718Ex-100G Support and Manuals
Get Help and Manuals for this Fluke item
This item is in your list!
View All Support Options Below
Free Fluke 718Ex-100G manuals!
Problems with Fluke 718Ex-100G?
Ask a Question
Free Fluke 718Ex-100G manuals!
Problems with Fluke 718Ex-100G?
Ask a Question
Most Recent Fluke 718Ex-100G Questions
Calibration Adjustment Of Pressure
Hi, i Want To Adjust Pressure,how To Do In 718ex 100g Pressure Calibratore
Hi, i Want To Adjust Pressure,how To Do In 718ex 100g Pressure Calibratore
(Posted by SHAHEERCTCL 10 years ago)
Popular Fluke 718Ex-100G Manual Pages
Fluke 717 and 718 Pressure Calibrator Datasheet - Page 1
... to service the pump without disassembly.
• Pressure Source and Milliamp Measurement to
calibrate and maintain almost any pressure device
• Integrated pump is about a third of the size of ownership and repairs - Fluke Pressure
Calibrators
Technical Data
Fluke 718 Pressure Calibrator
The complete solution to pressure calibration The Fluke 718 pressure calibrator family (4 models...
Fluke 717 and 718 Pressure Calibrator Datasheet - Page 2
... of tension. Replace if
needed .
8.
Set aside the valve assemblies in the field. Pump valve assembly cleaning instructions 1. The new pump design uses protective check valves that the o-rings seat properly. These two check valves allow air to at least 50 % its rated pressure.
11.
Seal the output of the Calibrator and pump up...
Fluke 717 and 718 Pressure Calibrator Datasheet - Page 3
...per pressure module specs
For additional detail on the 718, see the application note "Pressure calibration with the 718." Over pressure per pressure module specs
Resolution:
Per pressure module specs
Accuracy:
To 0.025 % of full span, per pressure module specs
Functions:
Zero, Min, Max, Hold, Damp, error calculation
Note: Media compatibility per pressure module specs
Fluke 718 series...
Fluke 718ex Users Manual - Page 1
Users Manual All rights reserved. All product names are trademarks of their respective companies. ®
718Ex 30G/100G Pressure Calibrator
May 2004
© 2004 Fluke Corporation.
Printed in U.S.A.
Fluke 718ex Users Manual - Page 4
718Ex 30G/100G Users Manual
Calibration ...21 Replacing the Battery 22 Approved Batteries...23 Parts and Accessories 24 Specifications...25 Pressure Sensor Input, 718Ex 30G 25 Pressure Sensor Input, 718Ex 100G 25 Pressure Sensor Range and Resolution 25 Pressure Module Input, 718Ex 30G and 718Ex 100G 26 DC mA Input, 718Ex 30G and 718Ex 100G 26 General Specifications 27 Product Compliance ...
Fluke 718ex Users Manual - Page 9
The Fluke Model 718Ex 30G and 718Ex 100G Pressure Calibrators (hereafter called "Calibrator") can be
1
"OL" appears at least 15 psi must be made in psi, kPa, and inHg units. 718Ex 30G/100G Pressure Calibrator
Introduction
XWWarning
Read "Safety Information" before using the Calibrator.
The Calibrator makes 5-digit pressure readings in
2
inH2O units.
To avoid display overflow, ...
Fluke 718ex Users Manual - Page 12
Replace damaged test
leads. • When using the Calibrator.
4 Do not use it if it can no longer be impaired. • Inspect the Calibrator before the COM probe. • Never use the Calibrator with the red holster removed. • Never open the Calibrator case. 718Ex 30G/100G Users Manual
XW Warning
To avoid electric shock, injury, or damage to...
Fluke 718ex Users Manual - Page 13
...; When using the Calibrator's internal pressure sensor, do not connect a pressure module at 50 % of pressure in the circuit. Pressure Calibrator Safety Information
• Replace the battery as soon as 2 µs rise time with the circuit.
• When servicing the Calibrator, use only specified replacement parts. If both a pressure module and the internal pressure sensor are defined in...
Fluke 718ex Users Manual - Page 14
718Ex 30G/100G Users Manual
• To avoid overpressure damage, do not apply pressure to the internal pressure sensor input that the Pressure/Vacuum Release Control is in the closed position (fully clockwise) and the Pressure/Vacuum switch is in the "+" position (fully clockwise). • If the Calibrator has been dropped or subjected to rough handling, remove the Calibrator to...
Fluke 718ex Users Manual - Page 15
... translation and/or printing errors, refer to the original English users manual. Hold in fixed position
Pressure Calibrator Safety Information
Faults and Damage
Applying a voltage greater than 30 V to the input of the Calibrator invalidates its Ex Approval and may impair its safe operation in an Exhazardous area. Fully observe all instructions, warnings, and cautions contained...
Fluke 718ex Users Manual - Page 21
... in Figure 4, where the Calibrator displays pressure measured with an external pump.
XW Warning
If both a pressure module and the internal sensor are identified in the "+" position (fully clockwise).
The internal pump can provide 30 psi (2.0685 bar) for Model 718Ex 30G or 100 psi (6.895 bar) for Model 718Ex 100G. When measuring the pressure of potentially hazardous gases...
Fluke 718ex Users Manual - Page 25
... Calibrator. To develop higher pressure or vacuum, use an external pump.
Use a Fluke 700PEx Pressure Module connected to setup and operating instructions included with the pressure module and pump.
17 Pressure modules are listed in Figure 6. Recommended Pressure Modules
Pressure Module
700P01Ex 700P24Ex 700P05Ex 700P06Ex 700P27Ex 700P09Ex 700PA4Ex 700P29Ex
External Pump 718Ex
30G/100G...
Fluke 718ex Users Manual - Page 29
..., test leads, pressure module, and pressure tubing. do not use abrasives or solvents. Calibration
Fluke recommends that the Calibrator be repaired and returned for a fixed fee. In other countries, contact a Fluke Service Center.
21 Follow replacement and connection instructions properly.
• Review this manual, or if the Calibrator needs repair, contact a Fluke Service Center.
Fluke 718ex Users Manual - Page 33
... and apply for temperature ranges -10 °C to 18 °C and 28 °C to 55 °C
Pressure Calibrator Specifications
Pressure Sensor Range and Resolution
Displayed Pressure
Units
Model 718Ex 30G Range and Resolution
Model 718Ex 100G Range and Resolution
psi inH2O at 4°C inH2O at 20°C cmH2O at 4°C cmH2O at 20°C bar mbar kPa inHg mmHg
kg...
Fluke 718ex Users Manual - Page 34
718Ex 30G/100G Users Manual
Pressure Module Input, 718Ex 30G and 718Ex 100G
Range
Resolution
Accuracy
(determined by Pressure Module)
DC mA Input, 718Ex 30G and 718Ex 100G
Range
Resolution
Accuracy, ±(% of Reading + Counts)
24 mA
0.001 mA
.02 + 2
Temperature coefficient: 0.005 % of range per °C for temperature ranges -10 °C to 18 °C and 28 °C to 55 °C
26
Fluke 718Ex-100G Reviews
Do you have an experience with the Fluke 718Ex-100G that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!