...Hold to capture changing measurements • Switch test feature for transmitters, gauges and switches. Fluke Pressure Calibrators Technical Data Fluke 718 Pressure Calibrator The complete solution to pressure calibration The Fluke 718 pressure calibrator family (4 models) provide a total pressure calibration solution for quicker and more accurate...52 mm (7.93 in x 3.86 in x 2.06 in) 600 g (21 oz) Size/weight (718 with holster): 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in Fluke 718) Display: LCD, 5 digit pressure and current simultaneous Accuracy: 0.05 % Note: For use with non-...
...Hold to capture changing measurements • Switch test feature for transmitters, gauges and switches. Fluke Pressure Calibrators Technical Data Fluke 718 Pressure Calibrator The complete solution to pressure calibration The Fluke 718 pressure calibrator family (4 models) provide a total pressure calibration solution for quicker and more accurate...52 mm (7.93 in x 3.86 in x 2.06 in) 600 g (21 oz) Size/weight (718 with holster): 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in Fluke 718) Display: LCD, 5 digit pressure and current simultaneous Accuracy: 0.05 % Note: For use with non-...
Fluke 717 and 718 Pressure Calibrator Datasheet
Page 2
... -12 PSI to 30 PSI, (-850 mbar to 2 bar, -85 to 206.84 kPa) 718 100G -12 PSI to 100 PSI, (-850 mbar to 6.895 bar, -85 to 689.48 kPa) 718 300G -12 PSI to 300 PSI, (-850 mbar to 20.68 bar, -85 to 2068.42 kPa ) 717 1G -1 PSI to...). 4. The Calibrator is quick, easy and only requires a tighten the cap. Pump valve assembly cleaning instructions 1. Seal the output of tension. The New 718 Calibrator Pump The new Fluke 718 is no remaining sign of residue. 5. Inspect the springs for any cuts, nicks, or wear. Repeat this , they may often still be approximately...
... -12 PSI to 30 PSI, (-850 mbar to 2 bar, -85 to 206.84 kPa) 718 100G -12 PSI to 100 PSI, (-850 mbar to 6.895 bar, -85 to 689.48 kPa) 718 300G -12 PSI to 300 PSI, (-850 mbar to 20.68 bar, -85 to 2068.42 kPa ) 717 1G -1 PSI to...). 4. The Calibrator is quick, easy and only requires a tighten the cap. Pump valve assembly cleaning instructions 1. Seal the output of tension. The New 718 Calibrator Pump The new Fluke 718 is no remaining sign of residue. 5. Inspect the springs for any cuts, nicks, or wear. Repeat this , they may often still be approximately...
Fluke 717 and 718 Pressure Calibrator Datasheet
Page 3
...0.025 % of full span, per pressure module specs Functions: Zero, Min, Max, Hold, Damp, error calculation Note: Media compatibility per pressure module specs Fluke 718 series via built in U.S.A. 2/2006 2577864 D-EN-N Rev A Printed in pump Range: Loop Power: -12 PSI or -850 mbar to full scale, ...Supported Pressure Units; Fluke 718 series via using optional Pressure Modules Range: 29 pressure modules, 0 - 1 in H20 to 10,000 psi, 2.5 mbar to 700 bar. PO Box 1186...
...0.025 % of full span, per pressure module specs Functions: Zero, Min, Max, Hold, Damp, error calculation Note: Media compatibility per pressure module specs Fluke 718 series via built in U.S.A. 2/2006 2577864 D-EN-N Rev A Printed in pump Range: Loop Power: -12 PSI or -850 mbar to full scale, ...Supported Pressure Units; Fluke 718 series via using optional Pressure Modules Range: 29 pressure modules, 0 - 1 in H20 to 10,000 psi, 2.5 mbar to 700 bar. PO Box 1186...