FE 576 Users Manual
Page 8
576 Delivery Content • The unit • Getting Started • Two AA batteries • Manual on CD • Thermocouple type K probe • Windows-based software on CD • USB cable 8
576 Delivery Content • The unit • Getting Started • Two AA batteries • Manual on CD • Thermocouple type K probe • Windows-based software on CD • USB cable 8
FE 576 Users Manual
Page 14
For more accurate readings, adjust the emissivity value for the type of infrared energy radiated by an object depends on the material and its temperature. The emissivity depends on its emissivity and its surface characteristics. Reflected energy Emitted energy Transmitted energy Target EMISSIVITY 14 576 Emissivity - Explanation The amount of material being measured.
For more accurate readings, adjust the emissivity value for the type of infrared energy radiated by an object depends on the material and its temperature. The emissivity depends on its emissivity and its surface characteristics. Reflected energy Emitted energy Transmitted energy Target EMISSIVITY 14 576 Emissivity - Explanation The amount of material being measured.
FE 576 Users Manual
Page 26
thermistor TC - 576 Mode - thermocouple Thermocouple type J Thermocouple type K ON Lock C/F Buzzer Backlight Set Default Ltd. The probe temperature is located at the bottom of the display. Access Laserflash Photoflash Auto/All ... of the handle behind the rubber cover. Thermocouple Settings Open the battery compartment and set the switches ON or Off according to the desired probe type.
thermistor TC - 576 Mode - thermocouple Thermocouple type J Thermocouple type K ON Lock C/F Buzzer Backlight Set Default Ltd. The probe temperature is located at the bottom of the display. Access Laserflash Photoflash Auto/All ... of the handle behind the rubber cover. Thermocouple Settings Open the battery compartment and set the switches ON or Off according to the desired probe type.
FE 576 Users Manual
Page 32
spot size at 3.8 feet) 50:1 ( 6mm spot size at 30°C (86°F), non condensing 1 mV/°C (°F) USB 1.1 2 x 1.5 V Alkaline Type AA 240 x 170 x 50 mm (7.9 x 6.7 x 2 inches) 1/4"-20 UNC 576 Specifications Temp. spot size at 0.98 feet) ± 2°C or ± 0.75%, whichever is greater at + 25°C (77°F) ±...