Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Page 1
...kg Three Year Warranty Recommended Accessories 11080-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. ... 54 II J,K,T,E,N,R,S Dual Time of Day ● Fluke 51 II Fluke 52 II Fluke 53 II Included Accessories Impact absorbing holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer ...
...kg Three Year Warranty Recommended Accessories 11080-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. ... 54 II J,K,T,E,N,R,S Dual Time of Day ● Fluke 51 II Fluke 52 II Fluke 53 II Included Accessories Impact absorbing holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer ...
FE 51 & 52 II Users Manual
Page 1
Users Manual Printed in USA All product names are trademarks of their respective companies. ® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved.
Users Manual Printed in USA All product names are trademarks of their respective companies. ® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved.
FE 51 & 52 II Users Manual
Page 4
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual
Page 5
... 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to : Fluke Corporation P.O. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www.fluke.com To register your product, visit www.fluke-...P.O. Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Contacting Fluke To order accessories, receive assistance, or locate the nearest Fluke distributor or Service Center, call: 1-888-99-FLUKE (1-888-993-5853) in USA 1-800-36-FLUKE (1-800-363-5853) in Canada +31-402...
... 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to : Fluke Corporation P.O. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www.fluke.com To register your product, visit www.fluke-...P.O. Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Contacting Fluke To order accessories, receive assistance, or locate the nearest Fluke distributor or Service Center, call: 1-888-99-FLUKE (1-888-993-5853) in USA 1-800-36-FLUKE (1-800-363-5853) in Canada +31-402...
FE 51 & 52 II Users Manual
Page 6
...: • Before using the thermometer inspect the case. The possibility of false readings can lead to the user. Look for cracks or missing plastic. 51 & 52 Series II Users Manual Table 1. Safety Information WWarning A Warning identifies conditions and actions that pose hazards to personal injury. • Do not use the thermometer if it...
...: • Before using the thermometer inspect the case. The possibility of false readings can lead to the user. Look for cracks or missing plastic. 51 & 52 Series II Users Manual Table 1. Safety Information WWarning A Warning identifies conditions and actions that pose hazards to personal injury. • Do not use the thermometer if it...
FE 51 & 52 II Users Manual
Page 7
When potential differences are anticipated between the two thermocouples. Safety Information (cont.) WWarning (cont.) • Model 52: Measurement errors may damage the meter or the equipment under test. • Use the proper thermocouples, function, and range for your thermometer. • Do not ... servicing the thermometer, use only specified replacement parts. • Do not use the thermometer with any part of the battery with the battery case. 3 51 & 52 Series II Introduction Table 1.
When potential differences are anticipated between the two thermocouples. Safety Information (cont.) WWarning (cont.) • Model 52: Measurement errors may damage the meter or the equipment under test. • Use the proper thermocouples, function, and range for your thermometer. • Do not ... servicing the thermometer, use only specified replacement parts. • Do not use the thermometer with any part of the battery with the battery case. 3 51 & 52 Series II Introduction Table 1.
FE 51 & 52 II Users Manual
Page 8
... Symbols W M Refer to Models 51 and 52 unless otherwise indicated. Then read the following : • Figure 1 and Table 3 describe the components. • Figure 2 and Table 4 describe the display. • Table 5 describes the functions of the buttons. To become familiar with the thermometer, study the following sections. 4 Battery. 51 & 52 Series II Users Manual Table 2.
... Symbols W M Refer to Models 51 and 52 unless otherwise indicated. Then read the following : • Figure 1 and Table 3 describe the components. • Figure 2 and Table 4 describe the display. • Table 5 describes the functions of the buttons. To become familiar with the thermometer, study the following sections. 4 Battery. 51 & 52 Series II Users Manual Table 2.
FE 51 & 52 II Users Manual
Page 9
Components A Thermocouple T1 input B Model 52: Thermocouple T2 input C Holster D Display E Buttons F Battery door G Batteries Figure 1. Components aas01f.eps 5 Components 3 4 5 6 7 xx 2 1 51 & 52 Series II Getting Started Table 3.
Components A Thermocouple T1 input B Model 52: Thermocouple T2 input C Holster D Display E Buttons F Battery door G Batteries Figure 1. Components aas01f.eps 5 Components 3 4 5 6 7 xx 2 1 51 & 52 Series II Getting Started Table 3.
FE 51 & 52 II Users Manual
Page 10
..., or offset. Display Elements A The thermocouple measurement includes an offset. B The displayed readings do not change. E Low battery. G The temperature unit. I The thermocouple type. 51 & 52 Series II Users Manual Display Elements 23 4 1 10 9 Figure 2. Display Elements xx 5 6 7 8 aas02f.eps Table 4. C A shift function is in progress. F Primary Display. Replace the batteries. See "Changing...
..., or offset. Display Elements A The thermocouple measurement includes an offset. B The displayed readings do not change. E Low battery. G The temperature unit. I The thermocouple type. 51 & 52 Series II Users Manual Display Elements 23 4 1 10 9 Figure 2. Display Elements xx 5 6 7 8 aas02f.eps Table 4. C A shift function is in progress. F Primary Display. Replace the batteries. See "Changing...
FE 51 & 52 II Users Manual
Page 11
... readings. Press G, M (CANCEL) to switch between Celsius (oC), Fahrenheit (oF), and Kelvin (K). Model 52: Press T to freeze or unfreeze the displayed readings. Press h to toggle showing the T1, T2, and T1-T2 (differential temperature measurement) in the secondary display. 51 & 52 Series II Getting Started Buttons A G (Shift function) Q M C h T Table 5. Press M to test the display...
... readings. Press G, M (CANCEL) to switch between Celsius (oC), Fahrenheit (oF), and Kelvin (K). Model 52: Press T to freeze or unfreeze the displayed readings. Press h to toggle showing the T1, T2, and T1-T2 (differential temperature measurement) in the secondary display. 51 & 52 Series II Getting Started Buttons A G (Shift function) Q M C h T Table 5. Press M to test the display...
FE 51 & 52 II Users Manual
Page 12
Buttons (cont.) Press D to start or exit Setup. (See "Changing Setup Options.") Press K to scroll to the Setup option you want to change . Press E to decrease the displayed setting. Press N to enter a Setup option. Press K to store the displayed setting in memory. 8 Press N to scroll to the Setup option you want to change . Press E again to increase the displayed setting. 51 & 52 Series II Users Manual D K N E Table 5.
Buttons (cont.) Press D to start or exit Setup. (See "Changing Setup Options.") Press K to scroll to the Setup option you want to change . Press E to decrease the displayed setting. Press N to enter a Setup option. Press K to store the displayed setting in memory. 8 Press N to scroll to the Setup option you want to change . Press E again to increase the displayed setting. 51 & 52 Series II Users Manual D K N E Table 5.
FE 51 & 52 II Users Manual
Page 13
... Hz) 9 If no thermocouple is plugged into the input connector(s). 2. Setup settings reset only when the batteries are removed for more than 2 minutes. 51 & 52 Series II Using the Thermometer Entering or Exiting Setup When the thermometer is "open," the display shows "- - - -" Changing Setup Options Use Setup to change the thermocouple type...input or the thermocouple is in its memory. Setup Options Option Menu Item Settings Thermocouple Type TYPE J, K, T, or E Offset O T1 or T2 (Model 52) Sleep Mode SLP on (sleep mode on the thermometer. Press A to start or exit Setup.
... Hz) 9 If no thermocouple is plugged into the input connector(s). 2. Setup settings reset only when the batteries are removed for more than 2 minutes. 51 & 52 Series II Using the Thermometer Entering or Exiting Setup When the thermometer is "open," the display shows "- - - -" Changing Setup Options Use Setup to change the thermocouple type...input or the thermocouple is in its memory. Setup Options Option Menu Item Settings Thermocouple Type TYPE J, K, T, or E Offset O T1 or T2 (Model 52) Sleep Mode SLP on (sleep mode on the thermometer. Press A to start or exit Setup.
FE 51 & 52 II Users Manual
Page 14
...want to change this setting. 3. Offset: The primary display shows the temperature plus the offset and the secondary display shows the offset. Model 52: You can store individual offsets for the local line frequency. 10 Line frequency: For optimum rejection of line noise, the thermometer must be ...and returns it is disabled in MIN MAX mode. Press E to 0.0 when it to store the new setting in MIN MAX mode. 51 & 52 Series II Users Manual Changing a Setup Option 1. Sleep mode: The thermometer enters sleep mode if no longer needed. Sleep mode becomes enabled each time you want...
...want to change this setting. 3. Offset: The primary display shows the temperature plus the offset and the secondary display shows the offset. Model 52: You can store individual offsets for the local line frequency. 10 Line frequency: For optimum rejection of line noise, the thermometer must be ...and returns it is disabled in MIN MAX mode. Press E to 0.0 when it to store the new setting in MIN MAX mode. 51 & 52 Series II Users Manual Changing a Setup Option 1. Sleep mode: The thermometer enters sleep mode if no longer needed. Sleep mode becomes enabled each time you want...
FE 51 & 52 II Users Manual
Page 15
... correct thermocouple type. The temperature reading appears in the primary display. 11 Model 52: Press to toggle between showing the T1, T2, and T1-T2 readings in the primary or secondary display. 51 & 52 Series II Measuring Temperatures Notes The display shows "- - - -" when a thermocouple is ...connected, the T2 reading appears in the primary display. Model 52: If only thermocouple T2 is not connected. Hold or attach the thermocouple...
... correct thermocouple type. The temperature reading appears in the primary display. 11 Model 52: Press to toggle between showing the T1, T2, and T1-T2 readings in the primary or secondary display. 51 & 52 Series II Measuring Temperatures Notes The display shows "- - - -" when a thermocouple is ...connected, the T2 reading appears in the primary display. Model 52: If only thermocouple T2 is not connected. Hold or attach the thermocouple...
FE 51 & 52 II Users Manual
Page 16
51 & 52 Series II Users Manual Holding the Displayed Readings 1. Press h to turn off the HOLD function. Press h again to freeze the readings on the display. 2. Press M to stabilize. 4. ... maximum occurred, appears on the display. Using the Offset to Adjust for the errors of a specific thermocouple. Plug the thermocouple into the input connector. 2. Model 52: Press T to toggle showing the T1, T2, or T1-T2 readings in Setup to adjust the thermometer's readings to exit MIN MAX mode. Viewing the...
51 & 52 Series II Users Manual Holding the Displayed Readings 1. Press h to turn off the HOLD function. Press h again to freeze the readings on the display. 2. Press M to stabilize. 4. ... maximum occurred, appears on the display. Using the Offset to Adjust for the errors of a specific thermocouple. Plug the thermocouple into the input connector. 2. Model 52: Press T to toggle showing the T1, T2, or T1-T2 readings in Setup to adjust the thermometer's readings to exit MIN MAX mode. Viewing the...
FE 51 & 52 II Users Manual
Page 17
... Temperature (14 oF to 122 oF) Storage −40 oC to +60 oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that the thermometer performs to +140 oF) Humidity Non condensing Turn off the thermometer if necessary. 2. Loosen the screw and remove... door and tighten the screw. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that you or follow the calibration procedure ...
... Temperature (14 oF to 122 oF) Storage −40 oC to +60 oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that the thermometer performs to +140 oF) Humidity Non condensing Turn off the thermometer if necessary. 2. Loosen the screw and remove... door and tighten the screw. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that you or follow the calibration procedure ...
FE 51 & 52 II Users Manual
Page 18
... to +752 oF) E-type: −150 oC to +1000 oC (−238 oF to +1832 oF) 0.1 oC / oF / K < 1000o 1.0 oC / oF / K ≥ 1000o 14 51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery Certification 3 AA batteries...
... to +752 oF) E-type: −150 oC to +1000 oC (−238 oF to +1832 oF) 0.1 oC / oF / K < 1000o 1.0 oC / oF / K ≥ 1000o 14 51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery Certification 3 AA batteries...
FE 51 & 52 II Users Manual
Page 19
...-t(y0p.5e:o±F[)0] .05 % of [below −100 oC (−148 oF): add 0.15 % of 1 year. The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756...
...-t(y0p.5e:o±F[)0] .05 % of [below −100 oC (−148 oF): add 0.15 % of 1 year. The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756...