FE 192,196,199 C Users Manual
Page 7
Contents (continued) Triggering on Video Signals 59 Triggering on Pulses ...61 6 Using Memory, PC and Printer 65 Saving and Recalling ...65 Documenting Screens...69 7 Tips ...73 Using the Standard Accessories ...
Contents (continued) Triggering on Video Signals 59 Triggering on Pulses ...61 6 Using Memory, PC and Printer 65 Saving and Recalling ...65 Documenting Screens...69 7 Tips ...73 Using the Standard Accessories ...
FE 192,196,199 C Users Manual
Page 51
... Intermittents Automatically When you use External Triggering to trigger and capture 100 intermittent glitches or you can also replay the stored screens continuously, like playing a video tape. For triggering, see Chapter 5: "Triggering on Waveforms". 43 Wait until the screen with the capability of capturing 100 screens for later replay, you could...
... Intermittents Automatically When you use External Triggering to trigger and capture 100 intermittent glitches or you can also replay the stored screens continuously, like playing a video tape. For triggering, see Chapter 5: "Triggering on Waveforms". 43 Wait until the screen with the capability of capturing 100 screens for later replay, you could...
FE 192,196,199 C Users Manual
Page 59
... About this Chapter This chapter provides an introduction to the trigger functions of the four manual trigger functions: • Edge triggering • External triggering • Video triggering • Pulse Width triggering 51 Triggering tells the test tool when to begin displaying the waveform.
... About this Chapter This chapter provides an introduction to the trigger functions of the four manual trigger functions: • Edge triggering • External triggering • Video triggering • Pulse Width triggering 51 Triggering tells the test tool when to begin displaying the waveform.
FE 192,196,199 C Users Manual
Page 67
.... Trigger level and slope are going sync pulses. 59 Measuring Interlaced Video Signals 6 4 Select Video on Video menu. Observe that the key labels at the bottom of specific video trigger settings: 5 Select positive signal polarity for video signals with negative going to measure: 1 Apply a video signal to allow further selection of the screen have been changed...
.... Trigger level and slope are going sync pulses. 59 Measuring Interlaced Video Signals 6 4 Select Video on Video menu. Observe that the key labels at the bottom of specific video trigger settings: 5 Select positive signal polarity for video signals with negative going to measure: 1 Apply a video signal to allow further selection of the screen have been changed...
FE 192,196,199 C Users Manual
Page 68
...8 Select number 123. The signal of the next line immediately after the test tool triggers on the horizontal synchronization pulse. To view a specific video line in more detail, you can select the line number. The signal of the even field is updated with the signal of the frame, ...horizontal synchronization). 7 Choose ALL LINES. The screen is continuously updated with the signal of one line is displayed on the screen. Fluke 192B - 196B/C - 199B/C Users Manual Triggering on Video Frames Use FIELD 1 or FIELD 2 to trigger either on the first half of the frame (odd) or on the second ...
...8 Select number 123. The signal of the next line immediately after the test tool triggers on the horizontal synchronization pulse. To view a specific video line in more detail, you can select the line number. The signal of the even field is updated with the signal of the frame, ...horizontal synchronization). 7 Choose ALL LINES. The screen is continuously updated with the signal of one line is displayed on the screen. Fluke 192B - 196B/C - 199B/C Users Manual Triggering on Video Frames Use FIELD 1 or FIELD 2 to trigger either on the first half of the frame (odd) or on the second ...
FE 192,196,199 C Users Manual
Page 69
... 4 Select Pulse Width on A... Detecting Narrow Pulses To set the test tool to trigger on narrow positive pulses shorter than 5 ms, do the following: 1 Apply a video signal to isolate and display specific pulses that you can qualify by time, such as glitches, missing pulses, bursts or signal dropouts.
... 4 Select Pulse Width on A... Detecting Narrow Pulses To set the test tool to trigger on narrow positive pulses shorter than 5 ms, do the following: 1 Apply a video signal to isolate and display specific pulses that you can qualify by time, such as glitches, missing pulses, bursts or signal dropouts.
FE 192,196,199 C Users Manual
Page 105
... MHz at 2 mV/div and 5 mV/div ...........1 division 200 MHz (FLUKE 199B/C 1 division 250 MHz (FLUKE 199B/C 2 divisions 100 MHz (FLUKE 196B/C 1 division 150 MHz (FLUKE 196B/C 2 divisions 60 MHz (FLUKE 192B 1 division 100 MHz (FLUKE 192B 2 divisions Isolated External Trigger Bandwidth 10 kHz Modes Automatic, Edge Trigger ...Glitch Capture Mode 300 min/max pairs on each input Glitch Detection 5 µs to 120 s/div......... FLUKE 192B: 10 ns to 2 µs /div up to 10 kHz 120 mV, 1.2 V Video Trigger Standards PAL, PAL+, NTSC, SECAM Modes Lines, Line Select, Field 1 or Field 2 Source...
... MHz at 2 mV/div and 5 mV/div ...........1 division 200 MHz (FLUKE 199B/C 1 division 250 MHz (FLUKE 199B/C 2 divisions 100 MHz (FLUKE 196B/C 1 division 150 MHz (FLUKE 196B/C 2 divisions 60 MHz (FLUKE 192B 1 division 100 MHz (FLUKE 192B 2 divisions Isolated External Trigger Bandwidth 10 kHz Modes Automatic, Edge Trigger ...Glitch Capture Mode 300 min/max pairs on each input Glitch Detection 5 µs to 120 s/div......... FLUKE 192B: 10 ns to 2 µs /div up to 10 kHz 120 mV, 1.2 V Video Trigger Standards PAL, PAL+, NTSC, SECAM Modes Lines, Line Select, Field 1 or Field 2 Source...
FE 192,196,199 C Users Manual
Page 122
X-Y mode, 20 -Z- Waveform comparing, 23 Waveform Options, 15 Waveform storage, 66 -X- Vertical Accuracy, 96 Vertical Cursors, 47 Vibration, 107 Video Frames, 60 Video Lines, 60 Video Trigger, 59, 97 Viewing Stored Screens, 69 Voltage Probes, 3, 86, 89 VP200 Voltage Probe, 89 VP200 Voltage Probe Set, 3 -W- Unpacking,...Automatic, 54, 97 Dual Slope, 52 External, 58 N-Cycle, 57 On Edges, 55 On Pulses, 61 On Video, 59 On Waveforms, 51 Troubleshooting, 93 TV Triggering, 59 -U- Fluke 192B - 196B/C - 199B/C Users Manual Scope Record, 104 Scope Record, 37 Screen Contrast, 78 Screen Without ...
X-Y mode, 20 -Z- Waveform comparing, 23 Waveform Options, 15 Waveform storage, 66 -X- Vertical Accuracy, 96 Vertical Cursors, 47 Vibration, 107 Video Frames, 60 Video Lines, 60 Video Trigger, 59, 97 Viewing Stored Screens, 69 Voltage Probes, 3, 86, 89 VP200 Voltage Probe, 89 VP200 Voltage Probe Set, 3 -W- Unpacking,...Automatic, 54, 97 Dual Slope, 52 External, 58 N-Cycle, 57 On Edges, 55 On Pulses, 61 On Video, 59 On Waveforms, 51 Troubleshooting, 93 TV Triggering, 59 -U- Fluke 192B - 196B/C - 199B/C Users Manual Scope Record, 104 Scope Record, 37 Screen Contrast, 78 Screen Without ...
Fluke ScopeMeter Product Datasheet
Page 2
...also allow as many as a trigger event and initiate a new waveform acquisition, a most useful capability when making adjustments to www.fluke.com/scopemeter High sampling rates give you isolate the phenomena of pulses. On-screen color labels, measurements and warnings are clearly linked.... N-cycle triggering ensures you 're looking at the display of vibration, signal interference or crosstalk. Manual modes include edge, delay, video and pulse width triggering. A fully isolated external trigger input is also handy for example, in a signal. Frequency spectrum analysis All 190C...
...also allow as many as a trigger event and initiate a new waveform acquisition, a most useful capability when making adjustments to www.fluke.com/scopemeter High sampling rates give you isolate the phenomena of pulses. On-screen color labels, measurements and warnings are clearly linked.... N-cycle triggering ensures you 're looking at the display of vibration, signal interference or crosstalk. Manual modes include edge, delay, video and pulse width triggering. A fully isolated external trigger input is also handy for example, in a signal. Frequency spectrum analysis All 190C...
Fluke ScopeMeter Product Datasheet
Page 5
...- Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 ...Fluke Europe B.V. Selection Table 120 and 190 Series ScopeMeter® Test Tools Bandwidth Max. record length (per input) Number of inputs Input sensitivity Independently floating isolated inputs Display and Display Modes Display Persistence Envelop Mode Waveform compare FFT Pass/Fail testing Triggering Connect-and-View™ Triggering Edge, single, free run Video Video...
...- Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 ...Fluke Europe B.V. Selection Table 120 and 190 Series ScopeMeter® Test Tools Bandwidth Max. record length (per input) Number of inputs Input sensitivity Independently floating isolated inputs Display and Display Modes Display Persistence Envelop Mode Waveform compare FFT Pass/Fail testing Triggering Connect-and-View™ Triggering Edge, single, free run Video Video...