Fluke 190-502 Support and Manuals
Get Help and Manuals for this Fluke item
This item is in your list!
View All Support Options Below
Free Fluke 190-502 manuals!
Problems with Fluke 190-502?
Ask a Question
Free Fluke 190-502 manuals!
Problems with Fluke 190-502?
Ask a Question
Popular Fluke 190-502 Manual Pages
Manual - Page 12
Fluke 190-xxx /S versions include also the following items (SCC290 kit):
# Description
14 FlukeView ScopeMeter Software for Windows activation key...black) d) Ground Spring for Fluke products online at: www.
.com 1.877.766.5412 Fluke 190 Series II Users Manual
The Fluke 190-502 includes also:
# Description
11 Voltage Probe Set (red)
12 Voltage Probe Set (blue)
Each set includes: a) 10:1 Voltage ...
Manual - Page 16
...Fluke 190-502: The BNC jacks can independently be connected to a voltage above earth ground.
8
MyFlukeStore Shop for Fluke... above earth ground. Fluke 190-062, 190-102, 190-104, 190-202, 190-204: The BNC...manual to indicate a measurement in which is connected to the overhead or underground utility service... fixed installation circuits inside a building. Fluke 190 Series II Users Manual
Voltage ...
Manual - Page 26
... illumination is off. AUTO appears at the top right of
the screen, as shown in MANUAL mode, do the following:
1 MANUAL Perform an Auto Set. The waveform identifier (A) is in Figure 7. Figure 7.
The input A zero icon at : www.
.com 1.877.766.5412 Fluke 190 Series II Users Manual
Displaying an Unknown Signal with Connect-and-View™
The...
Manual - Page 34
...of a reference signal to decrease
V
the sensitivity. ENTER
6
F4
Exit the menu.
Fluke 190 Series II Users Manual
Variable Input Sensitivity
The variable input sensitivity allows you start adjusting the variable sensitivity (the ... is displayed. x and Spectrum).
26
MyFlukeStore Shop for example to set the amplitude of the screen the text A Var is not available in the 10 mV/div ...
Manual - Page 84
Highlight DELETE ,
5
ENTER
Accept your choice and jump to the
filename field
6
F2
Select the file to be recalled,
7
ENTER
Recall the selected screen+setup. Fluke 190 series II Users Manual
Deleting Screens with Associated Setups
To recall a screen+setup, do the following :
1
Display the SAVE key labels. Observe that the recalled waveform is displayed and that HOLD appears on the...
Manual - Page 112
...
104
MyFlukeStore Shop for voltage/CAT ratings. See the VPS510 instruction sheet for Fluke products online at: www.
.com 1.877.766.5412 See the VPS510 instruction sheet for Probe Tip (black) • Ground Lead with the Fluke 190-502 test tool.
Fluke 190 Series II Users Manual
Replacement Parts (continued)
Voltage Probe Set, designed for use with Mini Alligator Clip (black) •...
Manual - Page 113
... 4-mm Test Probe for Probe Tip (black) • 1x Industrial Alligator for Fluke products online at: www.
.com 1.877.766.5412
105 Replacement Parts (continued)
BNC Feedthrough 50 Ohm terminator (set of two pieces, black) Li-ion battery (26 Wh, not recommended for models 190-xx4) Li-ion battery (52 Wh) Hangstrap
7 Maintaining the Test Tool...
Manual - Page 118
... detailed specifications, see section '10:1 Probe' on BNC DC Coupled 1 MΩ (±1 %)//14 pF (±2 pF)
Max. Fluke 190 Series II Users Manual
Oscilloscope
Isolated Inputs A,B, C and D (Vertical)
Number of Channels Fluke 190-xx2 2 (A, B) Fluke 190-xx4 4 (A,B,C,D)
Bandwidth, DC Coupled FLUKE 190-502 500 MHz (-3 dB) FLUKE 190-2xx 200 MHz (-3 dB) FLUKE 190-1xx 100 MHz (-3 dB) FLUKE 190...
Manual - Page 120
...MHz (FLUKE 190-502 2 divisions 200 MHz (FLUKE 190-2xx 1 division 250 MHz (FLUKE 190-2xx 2 divisions 100 MHz (FLUKE 190-1xx 1 division 150 MHz (FLUKE 190-1xx 2 divisions 60 MHz (FLUKE 190-062 1 division 100 MHz (FLUKE 190-062 2 divisions
Isolated External Trigger (190-xx2)
Bandwidth 3 kHz
Modes Automatic, Edge
Trigger Levels (DC to +1200 div Max. Fluke 190 Series II Users Manual
Trigger...
Manual - Page 126
...Fluke 190-202, -102, -062 1000 V CAT III
600 V CAT IV (For detailed specifications, see "Safety")
Meter Functions
Ranging Auto, Manual
Modes Normal, Relative
General
DC Common Mode Rejection (CMRR 100 dB AC Common Mode Rejection at : www.
.com 1.877.766.5412 Fluke 190 Series II Users Manual
Meter Measurements for Fluke...Fluke 190-502 1000 V CAT II
600 V CAT III (For detailed specifications...
Manual - Page 132
Fluke 190 Series II Users Manual
Environmental
Environmental MIL-PRF-28800F, Class 2
Temperature Operating: battery installed 0 to 40 °C (32 to 104 °F) no battery installed 0 to 50 °C...;F noncondensing
Altitude Operating, Fluke 190-2xx, -1xx, -062: CATIII 600V, CATII 1000V 3 km (10 000 feet) CATIV 600V, CATIII 1000V 2 km (6 600 feet) Operating, Fluke 190-502: CATIII 300V, CATII...
Manual - Page 133
... Voltage FLUKE 190-xx4, -102, -202, -062 (test tool or test tool + VPS410)
From any terminal to earth ground ......... 1000 V CAT III 600 V CAT IV
Between any terminal 1000 V CAT III 600 V CAT IV
FLUKE 190-502 (test...1000 V CAT III 600 V CAT IV
FLUKE 190-502
300 V CAT III
1000 V CAT II 600 V CAT III 300 V CAT III 1000 V CAT II 600 V CAT III
8 Specifications Safety
Max. They should be read as Vac...
Manual - Page 142
... Variations, 42 Smoothing waveforms, 21, 24 Software, 105 Software Version, 101 Specifications, 109 Spectrum, 28 Spike Capture, 23 Stand, 86 Storing, 95 Subtract waveforms, 27 SW90W Software, 3, 4, 80, 105
-T- ScopeMeter 190 Series II
Users Manual
Probe Accessory Extension Set, 105
Probe Calibration, 99, 122 Probe Replacement Set, 103, 104 Probe Tip to BNC Adapter, 4 Probe Type, 16, 33...
Manual - Page 148
... there is not required to search the Windows Update Web site on the internet for Fluke products online at: www.
.com 1.877.766.5412 To install drivers from the CD-ROM or from a location on . Fluke 190 Series II Users Manual
Installing the USB Drivers
To install the USB drivers, do the following:
1 Connect the Fluke 190 Series II instrument to select "Yes" and...
Datasheet - Page 8
...-series probes Probe Accessory Replacement Set for VPS400-series probes Probe Accessory Replacement Set for VPS500-series probes
Fluke.
MyFlukeStore www. 8SFhluokepCfoorprorFatliuonke SpcoropedMuetcerts190oSnelriineseIIat:
.com 1.877.766.5412 Ordering information
Models Fluke 190-502 Color ScopeMeter, 500 MHz, 2 channels plus DMM/Ext.input Fluke 190-502/S Color ScopeMeter, 500 MHz, 2 channels...
Fluke 190-502 Reviews
Do you have an experience with the Fluke 190-502 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!