Fluke 179/EFSP Support and Manuals
Get Help and Manuals for this Fluke item
This item is in your list!
View All Support Options Below
Free Fluke 179/EFSP manuals!
Problems with Fluke 179/EFSP?
Ask a Question
Free Fluke 179/EFSP manuals!
Problems with Fluke 179/EFSP?
Ask a Question
Popular Fluke 179/EFSP Manual Pages
Manual - Page 1
Models 175, 177 & 179
True RMS Multimeters
Users Manual
May 2003 Rev. 1, 10/08 © 2003-2008 Fluke Corporation. Printed in USA. All product names are subject to change without notice. Specifications are trademarks of their respective companies. All rights reserved.
Manual - Page 3
... AC and DC Voltage 6 Measuring Resistance ...6 Measuring Capacitance...6 Testing for Continuity...7 Measuring Temperature (Model 179 Only 7 Testing Diodes...7 Measuring AC or DC Current 8 Understanding AC Zero Input Behavior of True RMS Meters 8 Measuring Frequency...9 Using the Bar Graph ...9 Cleaning...10 Testing the Fuses ...10 Replacing the Battery and Fuses 10 Specifications...11
i
Manual - Page 4
... door. These voltages pose a shock hazard.
⇒ Replace the battery as soon as specified in doubt, have the
Meter serviced. ⇒ Always use the proper terminals, switch position...European Union directives $ Canadian Standards Association
T Double insulated
W Important Information; XW Warning. see manual
b s
Battery (Low battery when shown on the Meter, between the terminals or between ...
Manual - Page 5
... in Singapore +1-425-446-5500 from the primary supply level (overhead or underground utility service). Register your Meter at www.fluke.com.
The Fluke Model 175, Model 177, and Model 179 are in fixed-equipment installations at the distribution level; All figures show the Model 179.
A "Caution" identifies conditions and actions that could cause bodily harm or death. CAT IV...
Manual - Page 6
...9999 μF. Input terminal for voltage, continuity, resistance, diode, capacitance, frequency, and temperature (Model 179 only) measurements.
E
Farads from 2 Hz to 30 kHz.
G
Diode test.
Hz Frequency of...display flashes.
>20 A, OL is displayed.
Displays OL above 2.4 V.
Models 175, 177 & 179 Users Manual
Battery Saver ("Sleep Mode")
The Meter enters the "Sleep mode" and ...
Manual - Page 7
...No. Manual Range ...
MIN MAX AVG enabled.
bAtt
diSC
EEPr Err CAL Err OPEn
Error Messages Replace the battery immediately. Invalid calibration data. MAX, MIN, AVG Maximum, minimum... is interrupted.
Symbol
Meaning
7
nμ F, °F, °C
Measurement units. Replace battery.
10 610000mV
All possible ranges.
11 Bar graph
Analog display.
12 Auto Range...
Manual - Page 8
Models 175, 177 & 179 Users Manual
MIN MAX AVG Recording Mode
The MIN MAX AVG recording mode captures the minimum and maximum input values, ...all readings. When a new high or low is displayed. In the AutoHOLD mode, the Meter holds the reading on a rotary switch setting, e.g., to step through the low (MIN), average (AVG), and present readings.
⇒ To pause MIN MAX AVG recording without erasing ...
Manual - Page 9
... change the range in the MIN MAX AVG, or Display HOLD modes.
L switch position displays the software version number.
S
Disables automatic 2-minute backlight timeout.
(LoFF) (Model 177 and 179 Only)
5 Note
You cannot manually change .
3.
Manual - Page 10
...
HOLD MINMAX RANGE
Measuring Capacitance
HOLD MINMAX RANGE
+
_
+
_
AIK03F.EPS
+
_
+
6
AIK04F.EPS AIK05F.EPS when removing the test leads, remove the live lead; Models 175, 177 & 179 Users Manual
Making Basic Measurements
The figures on the following pages show how to the Meter, disconnect circuit power and discharge all high-voltage capacitors before...
Manual - Page 12
... Fuses".) • Use the proper terminals, switch position, and range for your measurement. • Never place the probes in series, turn power on. Models 175, 177 & 179 Users Manual
Measuring AC or DC Current
XW Warning
To avoid personal injury or damage to the Meter: • Never attempt to make a measurement. They do...
Manual - Page 14
Dirt or moisture in the terminals can affect readings. Testing the Fuses
XW Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse.
Test fuses as shown below. HOLD MINMAX RANGE
440 mA
11 A Models 175, 177 & 179 Users Manual
Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
Manual - Page 16
... crest factor ≤ 1.5 at > 250 Ω; For non-sinusoidal waveforms, add -(2% reading + 2% full scale) typical, for all models. 5. Models 175, 177 & 179 Users Manual
Function
Range 1
Resolution
Accuracy ±( [ % of Reading ] + [ Counts ] )
Model 175
Model 177
Model 179
AC Volts 2, 3
600.0 mV 6.000 V 60.00 V 600.0 V 1000 V
0.1 mV 0.001 V 0.01 V 0.1 V 1 V
1.0 % + 3 (45 Hz to 500...
Manual - Page 18
Models 175, 177 & 179 Users Manual
Function
Volts AC Volts DC mV/T
Overload Protection 1
1000 V RMS 1000 V RMS 1000 V RMS2
Input Impedance (Nominal)
> 10 MΩ < 100 pF > 10 MΩ < 100 pF
> ...
Datasheet - Page 1
...Specifications ©2000 Fluke Corporation Rev. A-11/2000
Fluke 170 Series True-rms Digital Multimeter
Extended Specifications
Model Differences
(all other specifications are the same for each model)
Feature
Backlight Temperature Measurement Basic dc voltage accuracy
175 0.15%
Model 177
•
0.09%
179... when making measurements
Battery replacement without voiding calibration
Integrated...
Datasheet - Page 3
Crest factor of Reading ] + [ Counts ] )
Resolution Model 175
Model 177
Model 179
AC Volts 2
DC mV DC Volts
600.0 mV 6.000V...up and running.
detects opens or shorts of 3, Document #2155 170 Series True-rms DMMs Extended Specifications ©2000 Fluke Corporation Rev. All rights reserved. Fluke. Page 3 of 250 ms or longer. All AC voltage and AC current ranges are not specified...