User Guide
Page 30
...MIBs: The library's Management Information Base (MIB) contains units of information that specifically describe an aspect of each drive in the library, firmware level, serial... single port v 6GB/s Serial Attached SCSI (SAS) - Download the SNMP MIB file for this library from http://www.support.dell.com. dual port Ultrium 4 Full Height drives v 4...v Compressed: 75.2 TB (2:1 compression) 1-8 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Maximum Library Storage Capacity and Data Transfer Rate Maximum library storage capacity and maximum data transfer rates are ...
...MIBs: The library's Management Information Base (MIB) contains units of information that specifically describe an aspect of each drive in the library, firmware level, serial... single port v 6GB/s Serial Attached SCSI (SAS) - Download the SNMP MIB file for this library from http://www.support.dell.com. dual port Ultrium 4 Full Height drives v 4...v Compressed: 75.2 TB (2:1 compression) 1-8 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Maximum Library Storage Capacity and Data Transfer Rate Maximum library storage capacity and maximum data transfer rates are ...
User Guide
Page 74
... Interface. b. Browse to run the latest level of library and drive firmware currently installed on your library host. 3. Enter secure for instructions. 4-18 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Log out of library and drive firmware, proceed to your library by completing the following steps: a. Update library and drive firmware on your library, if necessary. Install the MIB file on your...
... Interface. b. Browse to run the latest level of library and drive firmware currently installed on your library host. 3. Enter secure for instructions. 4-18 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Log out of library and drive firmware, proceed to your library by completing the following steps: a. Update library and drive firmware on your library, if necessary. Install the MIB file on your...
User Guide
Page 156
... Key Path Diagnostics page 4. EKM Server Settings, on your library, wait for the library or drive you have downloaded from the web site for all LME drives to be downloaded to the host then uploaded to initiate the file transfer and firmware update. 5-62 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Quiesce all drives, then unload all installed...
... Key Path Diagnostics page 4. EKM Server Settings, on your library, wait for the library or drive you have downloaded from the web site for all LME drives to be downloaded to the host then uploaded to initiate the file transfer and firmware update. 5-62 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Quiesce all drives, then unload all installed...
User Guide
Page 171
... the most likely based on the "Procedures for Isolating CRU Problems" on page 5-30. To download the latest library firmware, visit http://www.support.dell.com. After correcting the problem, run Library Verify before resuming normal library operations. Chapter 7. Troubleshooting v The library consists of replacement parts required. Power Supply - The following CRUs (Customer Replaceable Units): - If possible...
... the most likely based on the "Procedures for Isolating CRU Problems" on page 5-30. To download the latest library firmware, visit http://www.support.dell.com. After correcting the problem, run Library Verify before resuming normal library operations. Chapter 7. Troubleshooting v The library consists of replacement parts required. Power Supply - The following CRUs (Customer Replaceable Units): - If possible...
User Guide
Page 175
..."Unknown", run Library Verify (Service → Library Verify). Use an Ultra160 SCSI bus and high-quality cabling with library firmware level greater than...Tape library performance: The library is reported as "Chk Media/Rsvd Slot?" on the library after changing the ID. 3. Troubleshooting 7-5 Web: Manage Library → Perform Inventory). Library Enclosure (Service Spare) See "Isolating a Library Controller Card vs. If necessary, visit http://support.dell...backing up data over a network, consider comparing to download the latest levels of adapter device driver v Your ...
..."Unknown", run Library Verify (Service → Library Verify). Use an Ultra160 SCSI bus and high-quality cabling with library firmware level greater than...Tape library performance: The library is reported as "Chk Media/Rsvd Slot?" on the library after changing the ID. 3. Troubleshooting 7-5 Web: Manage Library → Perform Inventory). Library Enclosure (Service Spare) See "Isolating a Library Controller Card vs. If necessary, visit http://support.dell...backing up data over a network, consider comparing to download the latest levels of adapter device driver v Your ...
User Guide
Page 182
...that indicates a piece of the inventory table. 2. If the amber LED is bad, marginal, or invalid. See "Using the ITDT Firmware Update, Dump Retrieval and Drive Test Tool " on page 7-7. 1. Remove cartridge. If ITDT cannot successfully locate the LTO drive, ...12 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide b. Using the OCP, select Control → Open I /O Station. See "Isolating a Power Supply Problem" on , check the power supply or the power supply fans. To remove the cartridge from the web. 2. Refer to download the tool from the library: a....
...that indicates a piece of the inventory table. 2. If the amber LED is bad, marginal, or invalid. See "Using the ITDT Firmware Update, Dump Retrieval and Drive Test Tool " on page 7-7. 1. Remove cartridge. If ITDT cannot successfully locate the LTO drive, ...12 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide b. Using the OCP, select Control → Open I /O Station. See "Isolating a Power Supply Problem" on , check the power supply or the power supply fans. To remove the cartridge from the web. 2. Refer to download the tool from the library: a....
User Guide
Page 200
... drive through the library to load and unload a test cartridge thereby exercising some library functions. To download the ITDT tool and instructions for diagnostics. See note below regarding library firmware update. v Tests the performance of "Unexpected Data" if you attempt to downlevel the library firmware. Before using the tool, visit http://support.dell.com. 9-4 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide
... drive through the library to load and unload a test cartridge thereby exercising some library functions. To download the ITDT tool and instructions for diagnostics. See note below regarding library firmware update. v Tests the performance of "Unexpected Data" if you attempt to downlevel the library firmware. Before using the tool, visit http://support.dell.com. 9-4 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide
User Guide
Page 208
...then refer to "Configure Library: Drives" on page 10-5) back underneath the library. Push the black tab ( 8 in a 2U or 4U library Note: The small gray markers show where conductive tape should be placed to download the latest firmware for additional instructions. ...tab will be visible. 8. v If the test passes: - Run the Library Verify test. (Operator Control Panel: Service → Library Verify). Upgrade library firmware and drive firmware to Dell. 10-8 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide v If the test fails, an error code will be ...
...then refer to "Configure Library: Drives" on page 10-5) back underneath the library. Push the black tab ( 8 in a 2U or 4U library Note: The small gray markers show where conductive tape should be placed to download the latest firmware for additional instructions. ...tab will be visible. 8. v If the test passes: - Run the Library Verify test. (Operator Control Panel: Service → Library Verify). Upgrade library firmware and drive firmware to Dell. 10-8 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide v If the test fails, an error code will be ...
User Guide
Page 224
... the lock in the slot located in you being charged for shipping. 2. Important: Failure to Dell will secure the library accessor for any missing components. 10-24 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Visit http://www.support.dell.com/ to download the latest levels of these components to return all cables to the latest version. Place...
... the lock in the slot located in you being charged for shipping. 2. Important: Failure to Dell will secure the library accessor for any missing components. 10-24 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide Visit http://www.support.dell.com/ to download the latest levels of these components to return all cables to the latest version. Place...
User Guide
Page 246
...or Write operation because the cartridge is a vendor specific code indicating the failing component. Code Download - Reported LUNs data has changed 3F 0E - Write Protect - Mode Parameters Changed - ... Message has been received at the drive at an unexpected location 3B 0C - The firmware in the drive is a known format. The xx (ASCQ) is a suspicious WORM...3F 0F - Unknown Format - Cleaning Failure - WORM overwrite attempted. C-8 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide An operation could not be executed because it 29 04 -...
...or Write operation because the cartridge is a vendor specific code indicating the failing component. Code Download - Reported LUNs data has changed 3F 0E - Write Protect - Mode Parameters Changed - ... Message has been received at the drive at an unexpected location 3B 0C - The firmware in the drive is a known format. The xx (ASCQ) is a suspicious WORM...3F 0F - Unknown Format - Cleaning Failure - WORM overwrite attempted. C-8 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide An operation could not be executed because it 29 04 -...