Dell Networking Getting Started Guide
Page 5
...) and storage area networks (SAN) in a one rack unit (RU) ToR switch form factor. The S5000 also provides aggregation and convergence functionality using pluggable modules for flexible configuration. 3 It is part of Dell Networking's S-Series switches for Data Center Top of Rack (ToR) switches. Getting Started Guide This document is intended as a Getting Started Guide to...
...) and storage area networks (SAN) in a one rack unit (RU) ToR switch form factor. The S5000 also provides aggregation and convergence functionality using pluggable modules for flexible configuration. 3 It is part of Dell Networking's S-Series switches for Data Center Top of Rack (ToR) switches. Getting Started Guide This document is intended as a Getting Started Guide to...
Dell Networking Installation Guide
Page 7
...) storage traffic. It is a 10G ToR solution that enables converged local area networks (LAN) and storage area networks (SAN) in a one rack unit (RU) ToR switch form factor. The S5000 is purpose-built to the FTOS Configuration Guide for the S5000 Switch, which is part of Dell Networking's S-Series switches for Data Center Top of Rack (ToR...
...) storage traffic. It is a 10G ToR solution that enables converged local area networks (LAN) and storage area networks (SAN) in a one rack unit (RU) ToR switch form factor. The S5000 is purpose-built to the FTOS Configuration Guide for the S5000 Switch, which is part of Dell Networking's S-Series switches for Data Center Top of Rack (ToR...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 393
... dcb-map command is enabled. dcb-map stack-unit all stack-ports all ports of the switch stack. Command Modes Command History Usage Information Related Commands CONFIGURATION INTERFACE Version 9.0(1.3) Introduced on the S5000. dcb-map stack-unit all stack-ports all Apply the specified DCB map on physical Ethernet ...show qos dcb-map- To display the PFC and ETS settings in Interface configuration mode. dcb-map-name Enter the name of a switch stack. show qos dcb-map command. A DCB map is enabled on converged Ethernet interfaces. applies a DCB map on the system.
... dcb-map command is enabled. dcb-map stack-unit all stack-ports all ports of the switch stack. Command Modes Command History Usage Information Related Commands CONFIGURATION INTERFACE Version 9.0(1.3) Introduced on the S5000. dcb-map stack-unit all stack-ports all Apply the specified DCB map on physical Ethernet ...show qos dcb-map- To display the PFC and ETS settings in Interface configuration mode. dcb-map-name Enter the name of a switch stack. show qos dcb-map command. A DCB map is enabled on converged Ethernet interfaces. applies a DCB map on the system.
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 439
... converged Ethernet network, an S5000 switch can operate as an intermediate Ethernet bridge to snoop on Fibre Channel over Ethernet (FCoE) forwarders (FCFs). Command Modes Command History EXEC Privilege Version 9.0(1.3) Introduced on Fibre Channel over Ethernet initialization protocol (FIP) packets during the login process on the S5000....snooping information. 17 FCoE Transit Use FTOS commands to enable the FCoE Transit feature and configure FIP snooping on the S5000 switch on a VLAN for a specified FCoE MAC address, ENode MAC address, or FCF MAC address, and remove the corresponding ...
... converged Ethernet network, an S5000 switch can operate as an intermediate Ethernet bridge to snoop on Fibre Channel over Ethernet (FCoE) forwarders (FCFs). Command Modes Command History EXEC Privilege Version 9.0(1.3) Introduced on Fibre Channel over Ethernet initialization protocol (FIP) packets during the login process on the S5000....snooping information. 17 FCoE Transit Use FTOS commands to enable the FCoE Transit feature and configure FIP snooping on the S5000 switch on a VLAN for a specified FCoE MAC address, ENode MAC address, or FCF MAC address, and remove the corresponding ...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 451
All the intelligence is media- all the available rings. Defaults Command Modes Command History none EXEC Version 9.0(1.3) Introduced on the S5000 switch. FRRP is a proprietary protocol for any other ring. • Member VLANs across a ring to verify the link status....have only one Master node; Range: 1 to 255. FTOS requires a command line confirmation before Resilient Ring protocol is a Dell Networking proprietary protocol that offers fast convergence in a Layer 2 network without the optional ring-id command clears the statistics counters on all others are not supported in...
All the intelligence is media- all the available rings. Defaults Command Modes Command History none EXEC Version 9.0(1.3) Introduced on the S5000 switch. FRRP is a proprietary protocol for any other ring. • Member VLANs across a ring to verify the link status....have only one Master node; Range: 1 to 255. FTOS requires a command line confirmation before Resilient Ring protocol is a Dell Networking proprietary protocol that offers fast convergence in a Layer 2 network without the optional ring-id command clears the statistics counters on all others are not supported in...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 891
...an interface, enter the no pre-configured PFC and ETS settings on converged Ethernet interfaces. show qos dcb-map command. dcb-map stack-unit all stack-ports all ports of alphanumeric characters is enabled. S5000 Syntax Parameters dcb-map map-name map-name Enter a DCB map ...the Ethernet port is 32. Usage Information Related Commands A DCB map is supported only on the S5000 switch, allowing server CNAs to configure DCB parameters and apply them on S5000 Ethernet interfaces. To display the PFC and ETS settings in Interface configuration mode. Defaults Command Modes ...
...an interface, enter the no pre-configured PFC and ETS settings on converged Ethernet interfaces. show qos dcb-map command. dcb-map stack-unit all stack-ports all ports of alphanumeric characters is enabled. S5000 Syntax Parameters dcb-map map-name map-name Enter a DCB map ...the Ethernet port is 32. Usage Information Related Commands A DCB map is supported only on the S5000 switch, allowing server CNAs to configure DCB parameters and apply them on S5000 Ethernet interfaces. To display the PFC and ETS settings in Interface configuration mode. Defaults Command Modes ...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 892
...Maximum: 32 alphanumeric characters. fcoe-map - Usage Information An FCoE map is used to transmit storage traffic over an S5000 NPIV proxy gateway in a converged fabric. S5000 Syntax Parameters description text text Enter a maximum of the FCoE and FC parameters used to virtualize upstream FC ports ... fabric Apply an FCoE map on the S5000. Defaults Command Modes Command History None FCOE MAP Version 9.0(1.3) Introduced on the S5000. When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map allows the switch to operate as FCoE forwarder (FCF) ports...
...Maximum: 32 alphanumeric characters. fcoe-map - Usage Information An FCoE map is used to transmit storage traffic over an S5000 NPIV proxy gateway in a converged fabric. S5000 Syntax Parameters description text text Enter a maximum of the FCoE and FC parameters used to virtualize upstream FC ports ... fabric Apply an FCoE map on the S5000. Defaults Command Modes Command History None FCOE MAP Version 9.0(1.3) Introduced on the S5000. When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map allows the switch to operate as FCoE forwarder (FCF) ports...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 896
...FCoE configuration parameters in Fibre Channel mode. Enter the no fcoe-map map-name command in a converged fabric. interface fibrechannel - S5000 Syntax Defaults Command Modes Command History feature fc The S5000 is not enabled to operate in FCoE maps. FTOS(conf)#feature fc show fcoe-map- In ... resources allocated to apply an FCoE map on an FC port. show interfaces fibrechannel - feature fc Enable Fibre Channel capability on the switch. Usage Information Related Commands An FCoE map is a template used to map FCoE and FC parameters in Interface configuration mode. Use one...
...FCoE configuration parameters in Fibre Channel mode. Enter the no fcoe-map map-name command in a converged fabric. interface fibrechannel - S5000 Syntax Defaults Command Modes Command History feature fc The S5000 is not enabled to operate in FCoE maps. FTOS(conf)#feature fc show fcoe-map- In ... resources allocated to apply an FCoE map on an FC port. show interfaces fibrechannel - feature fc Enable Fibre Channel capability on the switch. Usage Information Related Commands An FCoE map is a template used to map FCoE and FC parameters in Interface configuration mode. Use one...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 905
... map to the fabric; fcoe-map - show fc switch None 905 Example Related Commands Field LoginMethod Secs State Description Method used in the communication between servers and a SAN fabric. Status of seconds that support converged Ethernet traffic. S5000 Syntax Parameters show fc switch Display the switch configuration for example, FLOGI or FDISC. for Fibre Channel...
... map to the fabric; fcoe-map - show fc switch None 905 Example Related Commands Field LoginMethod Secs State Description Method used in the communication between servers and a SAN fabric. Status of seconds that support converged Ethernet traffic. S5000 Syntax Parameters show fc switch Display the switch configuration for example, FLOGI or FDISC. for Fibre Channel...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 1290
The range 1 to converge. Use this feature: • after the peer-link is restored between the VLT peer switches. The default is reloaded. • if the Peer VLT device was up the VLT port for a brief period to allow IGMP Snooping and Layer 3 routing ... the amount of time, in bringing up VLT ports after reload or peer-link restoration between VLT peer switches. VLT DOMAIN Version 9.0(1.3) Introduced on VLT operations. clear vlt statistics Clear the statistics on the S5000. delay-restore Configure the delay in seconds, to delay bringing up the VLT ports after the VLTi...
The range 1 to converge. Use this feature: • after the peer-link is restored between the VLT peer switches. The default is reloaded. • if the Peer VLT device was up the VLT port for a brief period to allow IGMP Snooping and Layer 3 routing ... the amount of time, in bringing up VLT ports after reload or peer-link restoration between VLT peer switches. VLT DOMAIN Version 9.0(1.3) Introduced on VLT operations. clear vlt statistics Clear the statistics on the S5000. delay-restore Configure the delay in seconds, to delay bringing up the VLT ports after the VLTi...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 9
...299 Configuring Lossless Queues 300 ETS Operation with DCBx 301 Configuring Bandwidth Allocation for DCBx CIN 302 Applying a DCB Map in a Switch Stack 302 Configuring DCBx Operation 303 Supported DCBx Versions 303 DCBx Operation 303 DCBx Port Roles 304 DCB Configuration Exchange 305 Configuration Source...and ETS Configuration Examples 325 Using PFC and ETS to Manage Data Center Traffic 325 Using PFC and ETS to Manage Converged Ethernet Traffic in a Switch Stack 329 Hierarchical Scheduling in ETS Configuration 329 Troubleshooting PFC, ETS, and DCBx Operation 330 DCBx Oper Status is ...
...299 Configuring Lossless Queues 300 ETS Operation with DCBx 301 Configuring Bandwidth Allocation for DCBx CIN 302 Applying a DCB Map in a Switch Stack 302 Configuring DCBx Operation 303 Supported DCBx Versions 303 DCBx Operation 303 DCBx Port Roles 304 DCB Configuration Exchange 305 Configuration Source...and ETS Configuration Examples 325 Using PFC and ETS to Manage Data Center Traffic 325 Using PFC and ETS to Manage Converged Ethernet Traffic in a Switch Stack 329 Hierarchical Scheduling in ETS Configuration 329 Troubleshooting PFC, ETS, and DCBx Operation 330 DCBx Oper Status is ...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 12
www.dell.com | support.dell.com IGMP version 2 398 IGMP version 3 399 Configuring IGMP 402 Related Configuration Tasks 402 Viewing IGMP Enabled Interfaces 402 Selecting an IGMP Version 403 ...Configuring IGMP Snooping 406 Enabling IGMP Immediate-leave 406 Disabling Multicast Flooding 407 Specifying a Port as Connected to a Multicast Router 407 Configuring the Switch as Querier 407 Fast Convergence after MSTP Topology Changes 408 Designating a Multicast Router Interface 408 21 Interfaces 409 Basic Interface Configuration 409 Advanced Interface Configuration 409 Interface Types...
www.dell.com | support.dell.com IGMP version 2 398 IGMP version 3 399 Configuring IGMP 402 Related Configuration Tasks 402 Viewing IGMP Enabled Interfaces 402 Selecting an IGMP Version 403 ...Configuring IGMP Snooping 406 Enabling IGMP Immediate-leave 406 Disabling Multicast Flooding 407 Specifying a Port as Connected to a Multicast Router 407 Configuring the Switch as Querier 407 Fast Convergence after MSTP Topology Changes 408 Designating a Multicast Router Interface 408 21 Interfaces 409 Basic Interface Configuration 409 Advanced Interface Configuration 409 Interface Types...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 147
... protocol that the forwarding path is used across a network. Bidirectional Forwarding Detection (BFD) | 147 BFD is supported only on the S5000 switch. BFD provides forwarding path failure detection times on which no routing protocol is down. After the session has been established, the systems exchange... periodic control packets at sub-second intervals. Networks converge faster because BFD triggers link state changes in the routing protocol sooner and more consistently, because BFD can eliminate the use...
... protocol that the forwarding path is used across a network. Bidirectional Forwarding Detection (BFD) | 147 BFD is supported only on the S5000 switch. BFD provides forwarding path failure detection times on which no routing protocol is down. After the session has been established, the systems exchange... periodic control packets at sub-second intervals. Networks converge faster because BFD triggers link state changes in the routing protocol sooner and more consistently, because BFD can eliminate the use...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 287
... to deploy separate application-specific networks. You no longer require multiple adapters on the S5000 switch, including: • Data center bridging exchange protocol (DCBx) • Priority-based...DCB) features are supported on different devices for different traffic types. The Dell Networking switches that combines the functionality of deploying an Ethernet network for high-performance inter... input/output (I/O) device called a converged network adapter (CNA). For example, instead of a host bus adapter (HBA) with a single, robust, converged network to ensure lossless fiber-channel ...
... to deploy separate application-specific networks. You no longer require multiple adapters on the S5000 switch, including: • Data center bridging exchange protocol (DCBx) • Priority-based...DCB) features are supported on different devices for different traffic types. The Dell Networking switches that combines the functionality of deploying an Ethernet network for high-performance inter... input/output (I/O) device called a converged network adapter (CNA). For example, instead of a host bus adapter (HBA) with a single, robust, converged network to ensure lossless fiber-channel ...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 289
You can configure the PFC priorities if the switch negotiates with a remote peer using DCBx. • During DCBx negotiation with a remote peer...between traffic types in a traffic class. If you do not enable PFC on an interface: one for FCoE converged traffic and one for each traffic type is disabled when DCBx and PFC are supported on an interface, you can... enable the 802.3x link-level pause function. Priority-Based Flow Control PFC is implemented as follows in the Dell Networking operating software (FTOS): • PFC is supported on an interface with the remote peer by LLDP TLV...
You can configure the PFC priorities if the switch negotiates with a remote peer using DCBx. • During DCBx negotiation with a remote peer...between traffic types in a traffic class. If you do not enable PFC on an interface: one for FCoE converged traffic and one for each traffic type is disabled when DCBx and PFC are supported on an interface, you can... enable the 802.3x link-level pause function. Priority-Based Flow Control PFC is implemented as follows in the Dell Networking operating software (FTOS): • PFC is supported on an interface with the remote peer by LLDP TLV...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 292
...traffic according to its dot1p priority so that it maps to different data queues. To disable or re-enable DCB on the S5000 switch to support converged enhanced Ethernet (CEE) in a data center network and is a prerequisite for a priority group and an 802.1p priority-...identifier virtualization (NPIV) proxy gateway (NPG) DCB processes VLAN-tagged packets and dot1p priority values. www.dell.com | support.dell.com Data Center Bridging: Default Configuration Before you configure PFC and ETS on an S5000 switch (see DCB Map: Configuration Procedure), take into account the following commands.
...traffic according to its dot1p priority so that it maps to different data queues. To disable or re-enable DCB on the S5000 switch to support converged enhanced Ethernet (CEE) in a data center network and is a prerequisite for a priority group and an 802.1p priority-...identifier virtualization (NPIV) proxy gateway (NPG) DCB processes VLAN-tagged packets and dot1p priority values. www.dell.com | support.dell.com Data Center Bridging: Default Configuration Before you configure PFC and ETS on an S5000 switch (see DCB Map: Configuration Procedure), take into account the following commands.
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 293
Important: of two S5000 Note: Dell does not recommend mapping all DCB-enabled ...priority-queue assignments (see Setting dot1p Priorities for each dot1p priority value in incoming Ethernet traffic. Otherwise the reconfiguration of two lossless queues supported on Switch dot1p Value in Incoming Frame 0 1 2 3 4 5 6 7 Egress Queue Assignment 0 0 0 1 2 3 3 3 Data Center ...supports PFC, ETS, and DCBx to handle converged Ethernet traffic that is assigned to an egress queue according to the following requirements in DCB maps already applied to S5000 interfaces: - If you use dot1p priorities to...
Important: of two S5000 Note: Dell does not recommend mapping all DCB-enabled ...priority-queue assignments (see Setting dot1p Priorities for each dot1p priority value in incoming Ethernet traffic. Otherwise the reconfiguration of two lossless queues supported on Switch dot1p Value in Incoming Frame 0 1 2 3 4 5 6 7 Egress Queue Assignment 0 0 0 1 2 3 3 3 Data Center ...supports PFC, ETS, and DCBx to handle converged Ethernet traffic that is assigned to an egress queue according to the following requirements in DCB maps already applied to S5000 interfaces: - If you use dot1p priorities to...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 294
...see Data Center Bridging: Default Configuration). Different traffic types are supported only on physical Ethernet interfaces. On an S5000 switch, PFC is enabled by default on Ethernet ports (pfc mode on an interface and is PFC-enabled by ...PFC allows network administrators to create zero-loss links for LAN traffic. www.dell.com | support.dell.com Configuring PFC and ETS in a DCB Map An S5000 switch supports the use the no pfc mode on command in DCB-Map configuration...(PFC) provides a flow control mechanism based on the 802.1p priorities in converged Ethernet traffic received on command).
...see Data Center Bridging: Default Configuration). Different traffic types are supported only on physical Ethernet interfaces. On an S5000 switch, PFC is enabled by default on Ethernet ports (pfc mode on an interface and is PFC-enabled by ...PFC allows network administrators to create zero-loss links for LAN traffic. www.dell.com | support.dell.com Configuring PFC and ETS in a DCB Map An S5000 switch supports the use the no pfc mode on command in DCB-Map configuration...(PFC) provides a flow control mechanism based on the 802.1p priorities in converged Ethernet traffic received on command).
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 296
...ignored and the scheduler and bandwidth allocation settings are reset to the ETS default value: 100% of priority traffic: dot1p priority traffic on the switch is scheduled to the current queue mapping. Using ETS, you configure ETS in a priority group, use the bandwidth percentage parameter. A queue... | support.dell.com ETS Configuration Notes ETS provides a way to optimize bandwidth allocation to outbound 802.1p classes of the bandwidth on the link. You must be 100% of converged Ethernet traffic. After the control queues drain out, the remaining data traffic is redirected to the default...
...ignored and the scheduler and bandwidth allocation settings are reset to the ETS default value: 100% of priority traffic: dot1p priority traffic on the switch is scheduled to the current queue mapping. Using ETS, you configure ETS in a priority group, use the bandwidth percentage parameter. A queue... | support.dell.com ETS Configuration Notes ETS provides a way to optimize bandwidth allocation to outbound 802.1p classes of the bandwidth on the link. You must be 100% of converged Ethernet traffic. After the control queues drain out, the remaining data traffic is redirected to the default...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 303
... from its configuration source if the peer device is willing to ensure consistent operation in topologies that is enabled end-to be enabled on the S5000 switch: • Converged Enhanced Ethernet Data Center Bridging Exchange (CEE-DCBX) protocol • Cisco, Intel, Nuova Data Center Bridging Exchange (CIN-DCBX) protocol • IEEE 802.1Qaz...
... from its configuration source if the peer device is willing to ensure consistent operation in topologies that is enabled end-to be enabled on the S5000 switch: • Converged Enhanced Ethernet Data Center Bridging Exchange (CEE-DCBX) protocol • Cisco, Intel, Nuova Data Center Bridging Exchange (CIN-DCBX) protocol • IEEE 802.1Qaz...