Diagnostics and Troubleshooting Guide (.pdf)
Page 11
... 2 Messages and Codes 2-1 System Messages 2-1 System Beep Codes 2-9 Warning Messages 2-13 Diagnostics Messages 2-13 Chapter 3 Finding Software Solutions 3-1 Installing and Configuring Software 3-1 Expanded and Extended Memory 3-1 Using Software 3-2 Error Messages 3-2 Input Errors 3-2 Memory-Resident Programs 3-2 Program Conflicts 3-3 Checking for Memory Address Conflicts 3-3 Avoiding Interrupt Assignment Conflicts 3-3 xi
... 2 Messages and Codes 2-1 System Messages 2-1 System Beep Codes 2-9 Warning Messages 2-13 Diagnostics Messages 2-13 Chapter 3 Finding Software Solutions 3-1 Installing and Configuring Software 3-1 Expanded and Extended Memory 3-1 Using Software 3-2 Error Messages 3-2 Input Errors 3-2 Memory-Resident Programs 3-2 Program Conflicts 3-3 Checking for Memory Address Conflicts 3-3 Avoiding Interrupt Assignment Conflicts 3-3 xi
Diagnostics and Troubleshooting Guide (.pdf)
Page 14
... and Replacing the Computer Cover 6-1 Troubleshooting a Wet Computer 6-2 Troubleshooting a Damaged Computer 6-2 Troubleshooting the Battery 6-3 Troubleshooting Expansion Cards 6-4 Troubleshooting System Memory 6-5 Troubleshooting the Video Subsystem 6-6 Troubleshooting the System Board 6-8 Troubleshooting the Diskette/Tape Drive Subsystem 6-9 Checking the Diskette/Tape Drive Subsystem 6-9 Troubleshooting ... SCSI Backplane Board 6-17 Chapter 7 Getting Help 7-1 Technical Assistance 7-1 Help Tools 7-2 Frequently Asked Questions Cards 7-3 Dell Q&A 7-3 System Documentation 7-3 xiv
... and Replacing the Computer Cover 6-1 Troubleshooting a Wet Computer 6-2 Troubleshooting a Damaged Computer 6-2 Troubleshooting the Battery 6-3 Troubleshooting Expansion Cards 6-4 Troubleshooting System Memory 6-5 Troubleshooting the Video Subsystem 6-6 Troubleshooting the System Board 6-8 Troubleshooting the Diskette/Tape Drive Subsystem 6-9 Checking the Diskette/Tape Drive Subsystem 6-9 Troubleshooting ... SCSI Backplane Board 6-17 Chapter 7 Getting Help 7-1 Technical Assistance 7-1 Help Tools 7-2 Frequently Asked Questions Cards 7-3 Dell Q&A 7-3 System Documentation 7-3 xiv
Diagnostics and Troubleshooting Guide (.pdf)
Page 15
... Order-Status System 7-4 Technical Support Service 7-4 Problems With Your Order 7-5 Product Information 7-5 Returning Items for Warranty Repair or Credit 7-5 Before You Call 7-5 Dell Contact Numbers 7-8 Appendix A Diagnostic Video Tests A-1 Video Memory Test A-1 Video Hardware Test A-1 Text Mode Character Test A-1 Character Attributes Subtest (80 x 25 A-2 Character Set Subtest (80 x 25 A-3 Video Scan Alignment...
... Order-Status System 7-4 Technical Support Service 7-4 Problems With Your Order 7-5 Product Information 7-5 Returning Items for Warranty Repair or Credit 7-5 Before You Call 7-5 Dell Contact Numbers 7-8 Appendix A Diagnostic Video Tests A-1 Video Memory Test A-1 Video Hardware Test A-1 Text Mode Character Test A-1 Character Attributes Subtest (80 x 25 A-2 Character Set Subtest (80 x 25 A-3 Video Scan Alignment...
Diagnostics and Troubleshooting Guide (.pdf)
Page 21
... see if the problem recurs. Go to step 5. The power to your computer system was faulty, or the connections to safeguard your troubleshooting with Dell's Program Diskette Maker utility. No. Perform the steps in "Look and Listen" found later in this chapter. Go to Chapter 6, "Checking Inside...4. If you receive a system message or beep code? No. Backing Up Your Files You can also direct you to load its files into memory from the bootup sector on using the msbackup command. If you are using an operating system other than MS-DOS, see the documentation that appendix...
... see if the problem recurs. Go to step 5. The power to your computer system was faulty, or the connections to safeguard your troubleshooting with Dell's Program Diskette Maker utility. No. Perform the steps in "Look and Listen" found later in this chapter. Go to Chapter 6, "Checking Inside...4. If you receive a system message or beep code? No. Backing Up Your Files You can also direct you to load its files into memory from the bootup sector on using the msbackup command. If you are using an operating system other than MS-DOS, see the documentation that appendix...
Diagnostics and Troubleshooting Guide (.pdf)
Page 22
... for your keyboard operating properly? No. Go to step 8. Complete the following procedure to save new system information into EISA configuration memory as the monitor, keyboard, printer, external drives, scanners, or plotters). If your computer's external connections and switches. Go to ... does not function. Yes. The system configuration information was incorrect. Go to step 7. Go to Chapter 4, "Running the Dell Diagnostics." Go to step 9. Make sure that you have fixed the problem. The EISA configuration information and the system configuration information...
... for your keyboard operating properly? No. Go to step 8. Complete the following procedure to save new system information into EISA configuration memory as the monitor, keyboard, printer, external drives, scanners, or plotters). If your computer's external connections and switches. Go to ... does not function. Yes. The system configuration information was incorrect. Go to step 7. Go to Chapter 4, "Running the Dell Diagnostics." Go to step 9. Make sure that you have fixed the problem. The EISA configuration information and the system configuration information...
Diagnostics and Troubleshooting Guide (.pdf)
Page 24
...using the EISA Configuration Utility you do not have not resolved the problem, see Chapter 4, "Running the Dell Diagnostics." The System Setup Program You can easily correct certain system problems by the System Setup program and the... EISA Configuration Utility. If you have an EISA system, see Chapter 4, "Running the Dell Diagnostics." 1-4 Diagnostics and Troubleshooting Guide If after checking the settings in the System Setup program you have a ... Setup program, the change is not recorded into EISA configuration memory until you changed your system.
...using the EISA Configuration Utility you do not have not resolved the problem, see Chapter 4, "Running the Dell Diagnostics." The System Setup Program You can easily correct certain system problems by the System Setup program and the... EISA Configuration Utility. If you have an EISA system, see Chapter 4, "Running the Dell Diagnostics." 1-4 Diagnostics and Troubleshooting Guide If after checking the settings in the System Setup program you have a ... Setup program, the change is not recorded into EISA configuration memory until you changed your system.
Diagnostics and Troubleshooting Guide (.pdf)
Page 26
...table, see the abbreviation and acronym list that precedes the Index. 2-2 Diagnostics and Troubleshooting Guide See Chapter 4, "Running the Dell Diagnostics." Make sure you are using another operating system, run the appropriate utility to check the file structure of an abbreviation or... acronym used the correct pathname. Diskette subsystem reset failed The diskette drive controller may See "Troubleshooting System Memory" in the proper location, and used in Chapter 6. The opera- Drive not ready No diskette is in Chapter 6. See...
...table, see the abbreviation and acronym list that precedes the Index. 2-2 Diagnostics and Troubleshooting Guide See Chapter 4, "Running the Dell Diagnostics." Make sure you are using another operating system, run the appropriate utility to check the file structure of an abbreviation or... acronym used the correct pathname. Diskette subsystem reset failed The diskette drive controller may See "Troubleshooting System Memory" in the proper location, and used in Chapter 6. The opera- Drive not ready No diskette is in Chapter 6. See...
Diagnostics and Troubleshooting Guide (.pdf)
Page 27
... board microprocessor. The operating system is Remove the diskette from drive A and move the activated. One or more SIMMs or DIMMs may See "Troubleshooting System Memory" in Chapter 6. This message is installed. See "Troubleshooting Hard-Disk Drives" in be rebooted until an appropriate hardware change has been made. If you need...
... board microprocessor. The operating system is Remove the diskette from drive A and move the activated. One or more SIMMs or DIMMs may See "Troubleshooting System Memory" in Chapter 6. This message is installed. See "Troubleshooting Hard-Disk Drives" in be rebooted until an appropriate hardware change has been made. If you need...
Diagnostics and Troubleshooting Guide (.pdf)
Page 28
... Table 2-1. See your system documentation for a dualprocessor system if both processors do not have the same-size level-2 cache. Memory allocation error The software you need technical assistance, see the abbreviation and acronym list that precedes the Index. 2-4 Diagnostics and .... System Messages (continued) Cause Action This message appears for instructions. Keyboard data line failure Keyboard failure Keyboard stuck key failure Memory address line failure at address, read value expecting value One or more SIMMs may be faulty or improperly seated. NOTE: This...
... Table 2-1. See your system documentation for a dualprocessor system if both processors do not have the same-size level-2 cache. Memory allocation error The software you need technical assistance, see the abbreviation and acronym list that precedes the Index. 2-4 Diagnostics and .... System Messages (continued) Cause Action This message appears for instructions. Keyboard data line failure Keyboard failure Keyboard stuck key failure Memory address line failure at address, read value expecting value One or more SIMMs may be faulty or improperly seated. NOTE: This...
Diagnostics and Troubleshooting Guide (.pdf)
Page 29
... value expecting value Table 2-1. NOTE: For the full name of memory recorded in the system configuration information does not match the memory installed in be faulty or improperly seated. Messages and Codes 2-5 Chapter 6. Memory tests terminated by keystroke The memory test did not complete. Memory double word logic failure at address, read value expecting value...
... value expecting value Table 2-1. NOTE: For the full name of memory recorded in the system configuration information does not match the memory installed in be faulty or improperly seated. Messages and Codes 2-5 Chapter 6. Memory tests terminated by keystroke The memory test did not complete. Memory double word logic failure at address, read value expecting value...
Diagnostics and Troubleshooting Guide (.pdf)
Page 33
...acronym used in Chapter 7, "Getting Help," and then look it . Messages and Codes 2-9 At system start -up in nonvolatile random-access memory (NVRAM). Write fault Write fault on the monitor, your computer may emit a series of the beep code, use the system, but ... more serious cause. After displaying this table, see Chapter 7, "Getting Help." If you are overheated. You can continue to use the Dell Diagnostics to read the data in Table 2-2. System Messages (continued) Message Cause Action Warning Thermal Probes failed. Subsystem" in thermocouple that one...
...acronym used in Chapter 7, "Getting Help," and then look it . Messages and Codes 2-9 At system start -up in nonvolatile random-access memory (NVRAM). Write fault Write fault on the monitor, your computer may emit a series of the beep code, use the system, but ... more serious cause. After displaying this table, see Chapter 7, "Getting Help." If you are overheated. You can continue to use the Dell Diagnostics to read the data in Table 2-2. System Messages (continued) Message Cause Action Warning Thermal Probes failed. Subsystem" in thermocouple that one...
Diagnostics and Troubleshooting Guide (.pdf)
Page 34
... power loss Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 1-2-1 Programmable interval timer Run the System Set Test Group in Chapter 7. ning the Dell Diagnostics." 1-3-1 through 2-4-4 SIMMs or DIMMs not being See "Troubleshooting System Memory" in the Dell Diagnostics, if possible. Otherwise, see the abbreviation and acronym...
... power loss Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 1-2-1 Programmable interval timer Run the System Set Test Group in Chapter 7. ning the Dell Diagnostics." 1-3-1 through 2-4-4 SIMMs or DIMMs not being See "Troubleshooting System Memory" in the Dell Diagnostics, if possible. Otherwise, see the abbreviation and acronym...
Diagnostics and Troubleshooting Guide (.pdf)
Page 35
... Serial/Infrared Port Test Group and the Parallel Port Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 4-4-2 Failure to shadowed memory. See Chapter 4, "Running the Dell Diagnostics." 4-4-4 Cache test failure Run the System Set Test Group in the Dell Diagnostics, if possible. System Beep Codes (continued) Code Cause Action 3-3-2 NVRAM configuration...
... Serial/Infrared Port Test Group and the Parallel Port Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 4-4-2 Failure to shadowed memory. See Chapter 4, "Running the Dell Diagnostics." 4-4-4 Cache test failure Run the System Set Test Group in the Dell Diagnostics, if possible. System Beep Codes (continued) Code Cause Action 3-3-2 NVRAM configuration...
Diagnostics and Troubleshooting Guide (.pdf)
Page 36
... execution error Run the System Set Test Group in the Dell Diagnostics. NOTE: For the full name of an abbreviation or acronym used in the Dell Diagnostics. If the problem is installed, disconnect the video ...Dell Diagnostics." 6-1-3 Keyboard controller failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-2-1 BIOS shadowing failure Run the System Set Test Group in the Dell Diagnostics. Table 2-2. See Chapter 4, "Running the Dell Diagnostics." 6-2-3 No SIMM or DIMM installed See "Troubleshooting System Memory...
... execution error Run the System Set Test Group in the Dell Diagnostics. NOTE: For the full name of an abbreviation or acronym used in the Dell Diagnostics. If the problem is installed, disconnect the video ...Dell Diagnostics." 6-1-3 Keyboard controller failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-2-1 BIOS shadowing failure Run the System Set Test Group in the Dell Diagnostics. Table 2-2. See Chapter 4, "Running the Dell Diagnostics." 6-2-3 No SIMM or DIMM installed See "Troubleshooting System Memory...
Diagnostics and Troubleshooting Guide (.pdf)
Page 39
...files, such as described in Chapter 4, "Running the Dell Diagnostics." Viruses, which Dell computer you have, the system memory can be expanded by installing additional single in-line memory modules (SIMMs) or dual in-line memory modules (DIMMs) or by exchanging installed SIMMs or ...modify start-up files automatically. Software problems can confirm that a computer problem is configured, what its program diskettes. Expanded and Extended Memory Depending on the hard-disk drive, and permanently affect the performance of a program • Input errors • Device drivers ...
...files, such as described in Chapter 4, "Running the Dell Diagnostics." Viruses, which Dell computer you have, the system memory can be expanded by installing additional single in-line memory modules (SIMMs) or dual in-line memory modules (DIMMs) or by exchanging installed SIMMs or ...modify start-up files automatically. Software problems can confirm that a computer problem is configured, what its program diskettes. Expanded and Extended Memory Depending on the hard-disk drive, and permanently affect the performance of a program • Input errors • Device drivers ...
Diagnostics and Troubleshooting Guide (.pdf)
Page 40
... your operating system or application program documentation. Some, but not all Dell computers have more information about these TSR programs is set of the TSR programs probably created the conflict. Improper use of extended memory. Make sure the operating environment is causing a memory conflict, remove the commands that start -up files (such as...
... your operating system or application program documentation. Some, but not all Dell computers have more information about these TSR programs is set of the TSR programs probably created the conflict. Improper use of extended memory. Make sure the operating environment is causing a memory conflict, remove the commands that start -up files (such as...
Diagnostics and Troubleshooting Guide (.pdf)
Page 41
... refer to help you with your system documentation. If you are installing a Plug and Play card in the range of addresses, a memory address conflict arises. As a result, other programs cannot run the ISA Configuration Utility provided with Plug and Play capabilities, the default settings ... 3-1. There are available. Checking for one of the available IRQ lines. Then consult Table 3-1 to configure the card for Memory Address Conflicts Memory address conflicts occur when two or more devices try to find an available IRQ line. For instructions, see the abbreviation and acronym...
... refer to help you with your system documentation. If you are installing a Plug and Play card in the range of addresses, a memory address conflict arises. As a result, other programs cannot run the ISA Configuration Utility provided with Plug and Play capabilities, the default settings ... 3-1. There are available. Checking for one of the available IRQ lines. Then consult Table 3-1 to configure the card for Memory Address Conflicts Memory address conflicts occur when two or more devices try to find an available IRQ line. For instructions, see the abbreviation and acronym...
Diagnostics and Troubleshooting Guide (.pdf)
Page 46
... outgoing information and where to look for the diagnostics: • The system configuration information settings (stored in nonvolatile random-access memory [NVRAM]) that you selected while using the System Setup program • Identification tests of the microprocessor, the video controller, the... Corporation Dell System Diagnostics Version X.XX Available Test Groups RAM System Set Video Keyboard Mouse Diskette Drives Hard-Disk Drives (Non-SCSI) IDE CD ROM Drives Serial/Infrared Ports Parallel Ports SCSI Devices Network Interface Audio Other System Configuration Memory 4 MB Secondary ...
... outgoing information and where to look for the diagnostics: • The system configuration information settings (stored in nonvolatile random-access memory [NVRAM]) that you selected while using the System Setup program • Identification tests of the microprocessor, the video controller, the... Corporation Dell System Diagnostics Version X.XX Available Test Groups RAM System Set Video Keyboard Mouse Diskette Drives Hard-Disk Drives (Non-SCSI) IDE CD ROM Drives Serial/Infrared Ports Parallel Ports SCSI Devices Network Interface Audio Other System Configuration Memory 4 MB Secondary ...
Diagnostics and Troubleshooting Guide (.pdf)
Page 50
... when prompted. The result file is automatically created on your diagnostics diskette from drive A and reboot the computer. Test Limits NOTE: The Dell Diagnostics sets default limits on all error messages appear only on the hard-disk drive. After you are added at the end of messages ...all the subtests in addition to set of key controls available for the Serial/ Infrared Ports Test Group, you have selected. For example, memory address limits specified for Error Messages Ordinarily, all tests. Output Device for the RAM Test Group are added to increase or decrease the ...
... when prompted. The result file is automatically created on your diagnostics diskette from drive A and reboot the computer. Test Limits NOTE: The Dell Diagnostics sets default limits on all error messages appear only on the hard-disk drive. After you are added at the end of messages ...all the subtests in addition to set of key controls available for the Serial/ Infrared Ports Test Group, you have selected. For example, memory address limits specified for Error Messages Ordinarily, all tests. Output Device for the RAM Test Group are added to increase or decrease the ...
Diagnostics and Troubleshooting Guide (.pdf)
Page 51
...chips, DMA controller, computer timer, NVRAM, speaker controller, cache, and EISA configuration RAM chip, as appropriate. USB Memory Structure Test Monitors the ability of the USB interface. The diagnostics exercises the functional components and devices of these tests ...a USB controller to the microprocessor. Dell Diagnostics Tests Test Groups Subtests Description RAM Quick Memory Test Comprehensive Memory Test Secondary Cache Memory Test Tests the RAM and cache. (Some computers include expanded or extended memory; Tests in the Dell Diagnostics To troubleshoot components or devices...
...chips, DMA controller, computer timer, NVRAM, speaker controller, cache, and EISA configuration RAM chip, as appropriate. USB Memory Structure Test Monitors the ability of the USB interface. The diagnostics exercises the functional components and devices of these tests ...a USB controller to the microprocessor. Dell Diagnostics Tests Test Groups Subtests Description RAM Quick Memory Test Comprehensive Memory Test Secondary Cache Memory Test Tests the RAM and cache. (Some computers include expanded or extended memory; Tests in the Dell Diagnostics To troubleshoot components or devices...