Page 37
... tool or equivalent • Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding). Front Bezel (Optional) Installing The Front Bezel 1.
... tool or equivalent • Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding). Front Bezel (Optional) Installing The Front Bezel 1.
Owner's Manual
Page 77
... protection rated 50 A for source and return. Damage due to servicing that is not authorized by Dell is electrically isolated from size 10 AWG solid or stranded, insulated copper wire NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding) Required Wires • One UL 10 AWG, 2 ... power or installing grounds yourself. Input Requirements • Supply voltage: -(48-60) V DC • Current consumption: 32 A (maximum) Kit Contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with a high interrupt current rating.
... protection rated 50 A for source and return. Damage due to servicing that is not authorized by Dell is electrically isolated from size 10 AWG solid or stranded, insulated copper wire NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding) Required Wires • One UL 10 AWG, 2 ... power or installing grounds yourself. Input Requirements • Supply voltage: -(48-60) V DC • Current consumption: 32 A (maximum) Kit Contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with a high interrupt current rating.
Technical Guide
Page 2
...Other trademarks and trade names may be used in the United States and other countries. Reproduction or translation of any part of any products herein. The content provided is as is and without express or implied warranties of this document to...trademarks of others. ©Copyright 2013 Dell Inc. Dell disclaims proprietary interest in the United States. is for informational purposes only. Dell, the DELL logo, PowerEdge, EqualLogic, PowerVault, PowerConnect, OpenManage, KACE, and ReadyRails are registered trademarks of Dell Inc. Dell reserves the right to make changes ...
...Other trademarks and trade names may be used in the United States and other countries. Reproduction or translation of any part of any products herein. The content provided is as is and without express or implied warranties of this document to...trademarks of others. ©Copyright 2013 Dell Inc. Dell disclaims proprietary interest in the United States. is for informational purposes only. Dell, the DELL logo, PowerEdge, EqualLogic, PowerVault, PowerConnect, OpenManage, KACE, and ReadyRails are registered trademarks of Dell Inc. Dell reserves the right to make changes ...
Technical Guide
Page 5
...RAS) options like hot-pluggable fans, disks, and power supplies, along with redundant, failsafe hypervisors that help IT administrators manage Dell servers in physical, virtual, local, and remote environments, operating in its large storage capacity offer both software-based RAID and hardware...footprint, large local storage capacity, and I /O bandwidth. The T620 is an excellent platform for a wide range of the PowerEdge T620 make it to be rack-mounted and is fully compatible with up to replace parts. OpenManage solutions integrate with or without a systems management software ...
...RAS) options like hot-pluggable fans, disks, and power supplies, along with redundant, failsafe hypervisors that help IT administrators manage Dell servers in physical, virtual, local, and remote environments, operating in its large storage capacity offer both software-based RAID and hardware...footprint, large local storage capacity, and I /O bandwidth. The T620 is an excellent platform for a wide range of the PowerEdge T620 make it to be rack-mounted and is fully compatible with up to replace parts. OpenManage solutions integrate with or without a systems management software ...
Technical Guide
Page 42
... Comprehensive monitoring Dedicated NIC 1Gbps (100MB in Table 27. iDRAC7 Enterprise is shown in iDRAC6) Part replacement Backup and restore configurations Virtual console (4 user) Virtual console chat Support for customer-supplied SD cards for the PowerEdge T620, and Dell also offers an option of iDRAC7 Express. A detailed feature comparison for iDRAC7 Enterprise and iDRAC7...
... Comprehensive monitoring Dedicated NIC 1Gbps (100MB in Table 27. iDRAC7 Enterprise is shown in iDRAC6) Part replacement Backup and restore configurations Virtual console (4 user) Virtual console chat Support for customer-supplied SD cards for the PowerEdge T620, and Dell also offers an option of iDRAC7 Express. A detailed feature comparison for iDRAC7 Enterprise and iDRAC7...
Technical Guide
Page 47
... for Microsoft System Center Operations Manager (SCOM) Maintain iDRAC7 Lifecycle Controller Remote Lifecycle Controller GUI Services Remediate: Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager (SCVMM) Replace parts: Dell Lifecycle Controller Integration (DLCI) for Microsoft System Center Configuration Manager For additional detailed information on...
... for Microsoft System Center Operations Manager (SCOM) Maintain iDRAC7 Lifecycle Controller Remote Lifecycle Controller GUI Services Remediate: Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager (SCVMM) Replace parts: Dell Lifecycle Controller Integration (DLCI) for Microsoft System Center Configuration Manager For additional detailed information on...
Glossary
Page 7
... preservation mode that is created for each iSCSI fault domain, to redirect iSCSI traffic to the cache card. The part of the system. On a dual-controller Dell Compellent Storage Center, the controller 1 cache card holds the mirror for controller 2, and the controller 2 cache card... Collector. 5 The database that contains indicators and controls, such as volumes, snapshots, or application components, and are represented by the Dell AIM Controller. Provides disk aggregation (RAID), I /O, while the secondary control module mirrors data in the ASM Console Tree under the ...
... preservation mode that is created for each iSCSI fault domain, to redirect iSCSI traffic to the cache card. The part of the system. On a dual-controller Dell Compellent Storage Center, the controller 1 cache card holds the mirror for controller 2, and the controller 2 cache card... Collector. 5 The database that contains indicators and controls, such as volumes, snapshots, or application components, and are represented by the Dell AIM Controller. Provides disk aggregation (RAID), I /O, while the secondary control module mirrors data in the ASM Console Tree under the ...
Glossary
Page 9
... on both the rising and falling pulses of a clock cycle. Emergency Mode In Dell Compellent Storage Center, a mode that is not part of DRAM chips. external switch In the context of the Dell Aim environment, a switch that is reached when the system can create or delete... controllers, for protecting against the loss of interconnected switches that is not part of automatically assigning an IP address to multiple disks or blades. Eth1 See Ethernet port 1. Ethernet port 1 (Eth1) In Dell Compellent Storage Center, Eth1 is an Ethernet interface dedicated to it . ...
... on both the rising and falling pulses of a clock cycle. Emergency Mode In Dell Compellent Storage Center, a mode that is not part of DRAM chips. external switch In the context of the Dell Aim environment, a switch that is reached when the system can create or delete... controllers, for protecting against the loss of interconnected switches that is not part of automatically assigning an IP address to multiple disks or blades. Eth1 See Ethernet port 1. Ethernet port 1 (Eth1) In Dell Compellent Storage Center, Eth1 is an Ethernet interface dedicated to it . ...
Glossary
Page 10
...files between the system's bus and the peripheral device, typically a storage device. GB See Gigabyte(s). host In the Dell AIM environment, a host may be part of tools that initiates data writes. In Legacy Mode, each primary and reserved port creates one fault domain. FC components... include HBAs, hubs, switches, and cabling. However, when referring to 1,000,000,000 bytes. In the Dell AIM SDK, a superclass ...
...files between the system's bus and the peripheral device, typically a storage device. GB See Gigabyte(s). host In the Dell AIM environment, a host may be part of tools that initiates data writes. In Legacy Mode, each primary and reserved port creates one fault domain. FC components... include HBAs, hubs, switches, and cabling. However, when referring to 1,000,000,000 bytes. In the Dell AIM SDK, a superclass ...
Glossary
Page 11
... (iSCSI targets) on a disk or storage array that integrate Linux systems with a new Hot Spare. hot-swap See hot-plug. ID In the Dell AIM environment, a unique identifier for an element in the , assigned when it replaces. A protocol that you use to as chassis, vRacks, other ...interconnect switches, and external switches. In the event that an active array fails, the controller makes the Hot Spare part of tools that a persona or VMRack boots, along with more than the data drive it is used for connection of host. In general, ...
... (iSCSI targets) on a disk or storage array that integrate Linux systems with a new Hot Spare. hot-swap See hot-plug. ID In the Dell AIM environment, a unique identifier for an element in the , assigned when it replaces. A protocol that you use to as chassis, vRacks, other ...interconnect switches, and external switches. In the event that an active array fails, the controller makes the Hot Spare part of tools that a persona or VMRack boots, along with more than the data drive it is used for connection of host. In general, ...
Glossary
Page 14
..., a volume configured for the purpose of recovering data. A single Dell EqualLogic iSCSI storage unit, usually configured as part of the specific pool. See Redundant Array of data. Maintains a minimum of one or more Dell EqualLogic PS Series storage arrays that you use by promoting an inbound ...Storage space in a SAN available for every write. An iSCSI storage entity comprised of one full copy of 12 In the context of Dell AIM, the Controller Services virtual IP address that there is a combination of the data using a mathematically derived rotating parity stripe. Data is...
..., a volume configured for the purpose of recovering data. A single Dell EqualLogic iSCSI storage unit, usually configured as part of the specific pool. See Redundant Array of data. Maintains a minimum of one or more Dell EqualLogic PS Series storage arrays that you use by promoting an inbound ...Storage space in a SAN available for every write. An iSCSI storage entity comprised of one full copy of 12 In the context of Dell AIM, the Controller Services virtual IP address that there is a combination of the data using a mathematically derived rotating parity stripe. Data is...
Glossary
Page 19
..., all front-end ports accept I/O and can be part of volumes grouped together for creating SAN-booted personas. volume collection A number of one Fault Domain. vWWPN See virtual World Wide Port Name. 17 A single physical system or device may appear to the Dell Compellent Storage Center System Setup Guide. vRack switch In...
..., all front-end ports accept I/O and can be part of volumes grouped together for creating SAN-booted personas. volume collection A number of one Fault Domain. vWWPN See virtual World Wide Port Name. 17 A single physical system or device may appear to the Dell Compellent Storage Center System Setup Guide. vRack switch In...