Information Update - Intel Xeon 5600 Series Processors
Page 1
...130 W Intel Xeon 5600 series processors. R610 - NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of the Intel Xeon 5600 series processor. • The following new Dell PowerEdge systems marked with the Roman Numeral II on the chassis support the complete feature ... - R510 - NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor (less than 130 W). December 2010 You can download the BIOS and iDRAC firmware for the Intel Xeon 5600 series processor at support.dell.com. Intel Xeon 5600 Series...
...130 W Intel Xeon 5600 series processors. R610 - NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of the Intel Xeon 5600 series processor. • The following new Dell PowerEdge systems marked with the Roman Numeral II on the chassis support the complete feature ... - R510 - NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor (less than 130 W). December 2010 You can download the BIOS and iDRAC firmware for the Intel Xeon 5600 series processor at support.dell.com. Intel Xeon 5600 Series...
Information Update
Page 11
... • Default configuration files Use the Firmware Update page to update the CMC firmware to your local system. CMC Firmware Requirements PowerEdge M905 and M805 blades require CMC firmware version 1.2 or later. Updating the CMC Firmware Downloading the CMC Firmware Before beginning the firmware update, download the latest firmware version from the support.dell.com website, and save it to...
... • Default configuration files Use the Firmware Update page to update the CMC firmware to your local system. CMC Firmware Requirements PowerEdge M905 and M805 blades require CMC firmware version 1.2 or later. Updating the CMC Firmware Downloading the CMC Firmware Before beginning the firmware update, download the latest firmware version from the support.dell.com website, and save it to...
Information Update
Page 12
... be solid blue on the primary or active CMC module and off on the standby or secondary CMC. 2 Update the firmware on the active or primary CMC. Updating the CMC Firmware Using the Web-based Interface 1 Log in to the CMC Using the Web-Based Interface" in your M1000e Configuration Guide...using the RACADM getsysinfo command, or by using the getsysinfo command or through the Web-based interface. 4 After the standby CMC has rebooted, update the firmware on the standby CMC first. Use the following procedure for the standby CMC to reset the CMC in the Web-based interface. Failure to do...
... be solid blue on the primary or active CMC module and off on the standby or secondary CMC. 2 Update the firmware on the active or primary CMC. Updating the CMC Firmware Using the Web-based Interface 1 Log in to the CMC Using the Web-Based Interface" in your M1000e Configuration Guide...using the RACADM getsysinfo command, or by using the getsysinfo command or through the Web-based interface. 4 After the standby CMC has rebooted, update the firmware on the standby CMC first. Use the following procedure for the standby CMC to reset the CMC in the Web-based interface. Failure to do...
Information Update
Page 13
...Click Yes to continue. Keep different firmware revisions separated as the file name will need to refresh the User Interface page to log in . 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on your ...to navigate to the file location. Updating the CMC Firmware Using RACADM 1 Open a CMC command line console and log in again. PowerEdge M805 Memory sparing is supported if 24 identical memory modules (DIMMs) are installed. PowerEdge M905 Memory sparing is supported if 16 identical memory...
...Click Yes to continue. Keep different firmware revisions separated as the file name will need to refresh the User Interface page to log in . 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on your ...to navigate to the file location. Updating the CMC Firmware Using RACADM 1 Open a CMC command line console and log in again. PowerEdge M805 Memory sparing is supported if 24 identical memory modules (DIMMs) are installed. PowerEdge M905 Memory sparing is supported if 16 identical memory...
Information Update
Page 14
... module • Brocade M5424 FC8 switch module • Mellanox M3601Q QDR Infiniband switch module NOTE: CMC firmware version 1.3 is required to support FC8 mezzanine cards and I/O modules. 14 Information Update For detailed information on support.dell.com. See "Configuration Matrix for Quad-Port Mezzanine Card" on page 8 for the support matrix. •...
... module • Brocade M5424 FC8 switch module • Mellanox M3601Q QDR Infiniband switch module NOTE: CMC firmware version 1.3 is required to support FC8 mezzanine cards and I/O modules. 14 Information Update For detailed information on support.dell.com. See "Configuration Matrix for Quad-Port Mezzanine Card" on page 8 for the support matrix. •...
Information Update
Page 18
... ports operate at 8 Gb/sec, 4 Gb/sec, or 2 Gb/sec. To ensure proper functionality, use only SFPs provided with an RJ-45 connector. NOTE: CMC firmware version 1.3 is occurring No logical link to support FC8 mezzanine cards and I /O module includes eight external autosensing Fibre Channel ports (four ports are enabled in...
... ports operate at 8 Gb/sec, 4 Gb/sec, or 2 Gb/sec. To ensure proper functionality, use only SFPs provided with an RJ-45 connector. NOTE: CMC firmware version 1.3 is occurring No logical link to support FC8 mezzanine cards and I /O module includes eight external autosensing Fibre Channel ports (four ports are enabled in...
Information Update
Page 37
...; CMC 6 CMC cmcchangeover CMC CMC。 Web CMC 固件 1 Web M1000e Web CMC" 。 2 Chassis 3 单击 Update Updatable Components 4 在 Updatable Components CMC Firmware Update 5 在 Value Browse CMC firmimg.cmc 信息更新 37
...; CMC 6 CMC cmcchangeover CMC CMC。 Web CMC 固件 1 Web M1000e Web CMC" 。 2 Chassis 3 单击 Update Updatable Components 4 在 Updatable Components CMC Firmware Update 5 在 Value Browse CMC firmimg.cmc 信息更新 37
Information Update
Page 38
6 单击 Update 7 单击 Yes "Firmware Update in Progress CMC CMC User Interface 使用 RACADM 更新 CMC 固件 1 打开 CMC 2 键入: racadm fwupdate -g -u -a -d m 请参阅 support.dell.com Dell CMC PowerEdge M905 和 M805 PowerEdge M905 24 DIMM PowerEdge M805 16 38 信息更新
6 单击 Update 7 单击 Yes "Firmware Update in Progress CMC CMC User Interface 使用 RACADM 更新 CMC 固件 1 打开 CMC 2 键入: racadm fwupdate -g -u -a -d m 请参阅 support.dell.com Dell CMC PowerEdge M905 和 M805 PowerEdge M905 24 DIMM PowerEdge M805 16 38 信息更新
Dell PowerEdge M1000e Configuration Guide
Page 4
... . . 34 Configuring and Managing Power 35 Installing or Updating the CMC Firmware . . . . . 35 Configuring the Optional iKVM Switch Module . . . . 38 Enabling iKVM Access to the Dell CMC Console 38 Updating the iKVM Firmware 38 Tiering the Avocent iKVM Switch From an Analog KVM Switch 39 Tiering...52 Network Information 52 Switch Modules 52 Configuring a Switch Module Network Ethernet Port Using the Web-Based Interface 52 Dell PowerConnect-KR 8024-k Switch 53 Dell M8428-k 10 Gb Converged Network Switch 55 Mellanox M2401G DDR Infiniband Switch I/O Module 57 Mellanox M3601Q QDR Infiniband...
... . . 34 Configuring and Managing Power 35 Installing or Updating the CMC Firmware . . . . . 35 Configuring the Optional iKVM Switch Module . . . . 38 Enabling iKVM Access to the Dell CMC Console 38 Updating the iKVM Firmware 38 Tiering the Avocent iKVM Switch From an Analog KVM Switch 39 Tiering...52 Network Information 52 Switch Modules 52 Configuring a Switch Module Network Ethernet Port Using the Web-Based Interface 52 Dell PowerConnect-KR 8024-k Switch 53 Dell M8428-k 10 Gb Converged Network Switch 55 Mellanox M2401G DDR Infiniband Switch I/O Module 57 Mellanox M3601Q QDR Infiniband...
Dell PowerEdge M1000e Configuration Guide
Page 35
...The Power Budget Status page is normal for redundant CMC deployments. Failure to do so may cause unexpected behavior during CMC or iDRAC firmware updates on the various power management options, see "Power Management" in the enclosure and your needs. 6 Click Apply to save your... The Budget/Redundancy Configuration page is displayed. 5 Configure the power budget and redundancy settings based on the demand. Installing or Updating the CMC Firmware NOTE: It is displayed. 4 Click the Configuration sub-tab. For detailed information on a server. Use the following sections. NOTE: To ...
...The Power Budget Status page is normal for redundant CMC deployments. Failure to do so may cause unexpected behavior during CMC or iDRAC firmware updates on the various power management options, see "Power Management" in the enclosure and your needs. 6 Click Apply to save your... The Budget/Redundancy Configuration page is displayed. 5 Configure the power budget and redundancy settings based on the demand. Installing or Updating the CMC Firmware NOTE: It is displayed. 4 Click the Configuration sub-tab. For detailed information on a server. Use the following sections. NOTE: To ...
Dell PowerEdge M1000e Configuration Guide
Page 36
...-based interface. 4 After the standby CMC has rebooted, update the firmware on the active or primary CMC. Downloading the CMC Firmware Before beginning the firmware update, download the latest firmware version from support.dell.com, and save it to your CMC firmware package: • Compiled CMC firmware code and data • Web-based interface, JPEG, and other...
...-based interface. 4 After the standby CMC has rebooted, update the firmware on the active or primary CMC. Downloading the CMC Firmware Before beginning the firmware update, download the latest firmware version from support.dell.com, and save it to your CMC firmware package: • Compiled CMC firmware code and data • Web-based interface, JPEG, and other...
Dell PowerEdge M1000e Configuration Guide
Page 37
... in to the file location. Updating the CMC Firmware Using RACADM 1 Open a CMC command line console and log in. 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions on your management station... or shared network where the firmware image file resides, or click Browse to navigate to the CMC Using the ...
... in to the file location. Updating the CMC Firmware Using RACADM 1 Open a CMC command line console and log in. 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions on your management station... or shared network where the firmware image file resides, or click Browse to navigate to the CMC Using the ...
Dell PowerEdge M1000e Configuration Guide
Page 38
...displayed. 3 Click the Setup tab. The Firmware Update page is displayed. 4 Select Allow .... 4 Click the iKVM name. NOTE: The default iKVM firmware image name is complete, the iKVM resets. 38 Initial System...: 1 Log in the system tree. However, the iKVM firmware image name can be renamed. When the update is ikvm...path on your management station or shared network where the firmware image file resides, or click Browse to navigate to the... Console option. Updating the iKVM Firmware NOTE: The iKVM resets and becomes temporarily unavailable after the firmware has been uploaded successfully. 1...
...displayed. 3 Click the Setup tab. The Firmware Update page is displayed. 4 Select Allow .... 4 Click the iKVM name. NOTE: The default iKVM firmware image name is complete, the iKVM resets. 38 Initial System...: 1 Log in the system tree. However, the iKVM firmware image name can be renamed. When the update is ikvm...path on your management station or shared network where the firmware image file resides, or click Browse to navigate to the... Console option. Updating the iKVM Firmware NOTE: The iKVM resets and becomes temporarily unavailable after the firmware has been uploaded successfully. 1...
Dell PowerEdge M1000e Configuration Guide
Page 44
... accidently modifying any of 208. Broadcom M5708t Boot code firmware 4.4.1 or later iSCSI boot firmware 2.7.11 or later PXE firmware 4.4.3 or later FC mezzanine card - BIOS 3.03a3 and firmware 2.72A2 or M4 later Server Module BIOS (PowerEdge M600) BIOS 2.02 or later (PowerEdge M605) BIOS 2.03 or later PowerEdge M600/M605 LAN on a Secure Digital (SD) card...
... accidently modifying any of 208. Broadcom M5708t Boot code firmware 4.4.1 or later iSCSI boot firmware 2.7.11 or later PXE firmware 4.4.3 or later FC mezzanine card - BIOS 3.03a3 and firmware 2.72A2 or M4 later Server Module BIOS (PowerEdge M600) BIOS 2.02 or later (PowerEdge M605) BIOS 2.03 or later PowerEdge M600/M605 LAN on a Secure Digital (SD) card...
Dell PowerEdge M1000e Configuration Guide
Page 45
Component Server Module BIOS iDRAC CMC Minimum required version PowerEdge M710HD Version 3.0 or later Version 3.0 or later For more information... see the following resources: • The CMC Secure Digital (SD) Card Technical Specification document at support.dell.com. • The Help link in the CMC Web interface. • The "Using FlexAddress" chapter in ...the table below include, BIOS, iDRAC, and CMC firmware. Activating FlexAddress Plus FlexAddress Plus is activated, you can use FlexAddress Plus. The updates, which are not ...
Component Server Module BIOS iDRAC CMC Minimum required version PowerEdge M710HD Version 3.0 or later Version 3.0 or later For more information... see the following resources: • The CMC Secure Digital (SD) Card Technical Specification document at support.dell.com. • The Help link in the CMC Web interface. • The "Using FlexAddress" chapter in ...the table below include, BIOS, iDRAC, and CMC firmware. Activating FlexAddress Plus FlexAddress Plus is activated, you can use FlexAddress Plus. The updates, which are not ...
Dell PowerEdge M1000e Configuration Guide
Page 71
... standard configuration and four additional ports may be enabled as an optional upgrade), 16 internal ports, and one serial port with this module. NOTE: CMC firmware version 1.3 is required to support FC8 mezzanine cards and I /O Modules 71 The external Fibre Channel ports operate at 8 Gb/sec, 4 Gb/sec, or 2 Gb/sec...
... standard configuration and four additional ports may be enabled as an optional upgrade), 16 internal ports, and one serial port with this module. NOTE: CMC firmware version 1.3 is required to support FC8 mezzanine cards and I /O Modules 71 The external Fibre Channel ports operate at 8 Gb/sec, 4 Gb/sec, or 2 Gb/sec...
Dell PowerEdge M1000e Configuration Guide
Page 73
...Wave Small Form Factor Pluggable (SFP) optical transceivers. To ensure proper functionality, use only SFPs provided with an RJ-45 connector. Dell 8/4 Gbps FC SAN Module The Dell 8/4 Gbps FC SAN module (see Figure 3-15) includes 24 total autosensing Fibre Channel ports (12 ports are enabled in the... standard configuration and 12 additional ports may be enabled as an optional upgrade) and one serial port with this module. NOTE: CMC firmware version 1.3 ...
...Wave Small Form Factor Pluggable (SFP) optical transceivers. To ensure proper functionality, use only SFPs provided with an RJ-45 connector. Dell 8/4 Gbps FC SAN Module The Dell 8/4 Gbps FC SAN module (see Figure 3-15) includes 24 total autosensing Fibre Channel ports (12 ports are enabled in the... standard configuration and 12 additional ports may be enabled as an optional upgrade) and one serial port with this module. NOTE: CMC firmware version 1.3 ...
Hardware Owner's Manual
Page 39
.... Table 1-7. The ACI is being sent or received. Allows a keyboard and mouse to be connected to the external switch. Data is not being identified. Firmware upgrade in progress iKVM module is not connected to a Dell console switch with an Analog Rack Interface (ARI) port, such as an external digital or analog switch.
.... Table 1-7. The ACI is being sent or received. Allows a keyboard and mouse to be connected to the external switch. Data is not being identified. Firmware upgrade in progress iKVM module is not connected to a Dell console switch with an Analog Rack Interface (ARI) port, such as an external digital or analog switch.
Hardware Owner's Manual
Page 45
... that the CMC can enable or place power supplies in progress. Blue (solid) This CMC is operating normally. Amber blinking A fault has occurred. Green blinking Firmware update in standby dynamically depending on load and redundancy requirements to improve power efficiency. - Fault indicator Off The CMC is the primary CMC. The CMC...
... that the CMC can enable or place power supplies in progress. Blue (solid) This CMC is operating normally. Amber blinking A fault has occurred. Green blinking Firmware update in standby dynamically depending on load and redundancy requirements to improve power efficiency. - Fault indicator Off The CMC is the primary CMC. The CMC...
Hardware Owner's Manual
Page 49
... Fabric B slots. Fabric B Fabric B is a dual port, 1 to 10 Gb/sec , quad-lane redundant fabric, supporting I /O module slots C1 and C2. NOTE: LOM firmware updates are applied only to the enabled ports on the type of IO module installed. Modules designed for Fabric A may also be installed in Quad...-Port Network Daughter Card (M710HD Only) Systems installed with a 48-port switch module (32 internal ports) for Fabric A may also be active. NOTE: A quad-port Network Daughter ...
... Fabric B slots. Fabric B Fabric B is a dual port, 1 to 10 Gb/sec , quad-lane redundant fabric, supporting I /O module slots C1 and C2. NOTE: LOM firmware updates are applied only to the enabled ports on the type of IO module installed. Modules designed for Fabric A may also be installed in Quad...-Port Network Daughter Card (M710HD Only) Systems installed with a 48-port switch module (32 internal ports) for Fabric A may also be active. NOTE: A quad-port Network Daughter ...