Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 11
... RACADM commands. • Remote - Also referred as a laptop or desktop. The utility runs on the Dell OpenManage Systems Management and Documentation DVD or at support.dell.com. It is accessible by logging in to run Remote RACADM commands. You do not have to specify ...and object definitions of CMC for SSH/Telnet and Remote RACADM. The RACADM utility supports the following section describes the syntax usage for PowerEdge FX2/FX2s. RACADM Syntax Usage The following interfaces: • SSH or Telnet - Supports executing RACADM commands from the OpenManage software on the ...
... RACADM commands. • Remote - Also referred as a laptop or desktop. The utility runs on the Dell OpenManage Systems Management and Documentation DVD or at support.dell.com. It is accessible by logging in to run Remote RACADM commands. You do not have to specify ...and object definitions of CMC for SSH/Telnet and Remote RACADM. The RACADM utility supports the following section describes the syntax usage for PowerEdge FX2/FX2s. RACADM Syntax Usage The following interfaces: • SSH or Telnet - Supports executing RACADM commands from the OpenManage software on the ...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 15
... Online Help, click Help on the CMC web interface. • The Chassis Management Controller for PowerEdge FX2/FX2s User's Guide provides information about using the VRTX-related Web interface features. • The Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2/FX2s Version Release Notes provides last-minute updates to the system or documentation or advanced technical reference...
... Online Help, click Help on the CMC web interface. • The Chassis Management Controller for PowerEdge FX2/FX2s User's Guide provides information about using the VRTX-related Web interface features. • The Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2/FX2s Version Release Notes provides last-minute updates to the system or documentation or advanced technical reference...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 59
... Information: System Model System AssetTag Service Tag Express Service Code Chassis Name Chassis Location Chassis Midplane Version Power Status System ID PCIe Switch Board Type = PowerEdge FX2s = 00000 = STPST06 = 62746758870 = CMC-STPST06 = [UNDEFINED] = 1.0 = ON = 1488 = Gen 3 NOTE: In the Chassis Information output, the PCIe Switch Board Type information is displayed only for...
... Information: System Model System AssetTag Service Tag Express Service Code Chassis Name Chassis Location Chassis Midplane Version Power Status System ID PCIe Switch Board Type = PowerEdge FX2s = 00000 = STPST06 = 62746758870 = CMC-STPST06 = [UNDEFINED] = 1.0 = ON = 1488 = Gen 3 NOTE: In the Chassis Information output, the PCIe Switch Board Type information is displayed only for...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 64
... replace [-u ] [-p ] [-f ] [-1 ] [-t ] NOTE: License operations the name should be less than 56 Characters. Installs a new license. • export - File name of the license file. Password for PowerEdge FX2/FX2s Unique Identifier = License #1 Status = OK Transaction ID = 8 License Description = CMC Enterprise Evaluation License License Type = EVALUATION Entitlement ID = A2Wir6lJ1MoP8iBAtqsEKDv8 Expiration = 1982-04-07T21:00:00...
... replace [-u ] [-p ] [-f ] [-1 ] [-t ] NOTE: License operations the name should be less than 56 Characters. Installs a new license. • export - File name of the license file. Password for PowerEdge FX2/FX2s Unique Identifier = License #1 Status = OK Transaction ID = 8 License Description = CMC Enterprise Evaluation License License Type = EVALUATION Entitlement ID = A2Wir6lJ1MoP8iBAtqsEKDv8 Expiration = 1982-04-07T21:00:00...
Dell PowerEdge FN I/O Aggregator Command Line Reference Guide 9.6.(0.0)
Page 19
...unit 0 iom-mode vlt Select this mode, port 9 link, which is associated with the product, you install the Aggregator in a Dell PowerEdge FX2 server chassis. This is a low-touch mode where all configuration except VLAN membership is the default mode for customized network operation. This... mode 19 In this mode to multi-home server interfaces to different IOA modules. 2 Before You Start By following the instructions in the Dell PowerEdge FN I/O Aggregator Getting Started Guide that is shipped with LAG-127, is dedicated to VLT interconnect. To enable a new operational mode, ...
...unit 0 iom-mode vlt Select this mode, port 9 link, which is associated with the product, you install the Aggregator in a Dell PowerEdge FX2 server chassis. This is a low-touch mode where all configuration except VLAN membership is the default mode for customized network operation. This... mode 19 In this mode to multi-home server interfaces to different IOA modules. 2 Before You Start By following the instructions in the Dell PowerEdge FN I/O Aggregator Getting Started Guide that is shipped with LAG-127, is dedicated to VLT interconnect. To enable a new operational mode, ...
Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0.0)
Page 13
... Keywords and parameters separated by a bar require you to choose any or all of the options. Tasks supported by using either the Dell command line or the chassis management controller (CMC) graphical interface. Keyword parameter {X} [X] x|y x||y Keywords are in Courier (a monospaced ...some of the supported RFCs and management information base files (MIBs). Parameters are optional. The instructions in a Dell PowerEdge FX2 server chassis. 1 About this Guide This guide describes the supported protocols and software features, and provides configuration instructions and examples, ...
... Keywords and parameters separated by a bar require you to choose any or all of the options. Tasks supported by using either the Dell command line or the chassis management controller (CMC) graphical interface. Keyword parameter {X} [X] x|y x||y Keywords are in Courier (a monospaced ...some of the supported RFCs and management information base files (MIBs). Parameters are optional. The instructions in a Dell PowerEdge FX2 server chassis. 1 About this Guide This guide describes the supported protocols and software features, and provides configuration instructions and examples, ...
Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0.0)
Page 15
... fully automated zero-touch mode that is shipped with the product. Standalone mode stack-unit unit iom-mode standalone CONFIGURATION mode Dell(conf)#stack-unit 0 iom-mode standalone This is automated. Select the operational mode that are automatically configured at the server... default mode for customized network operation, use the instructions in the Dell PowerEdge FN I /O Aggregator (also known as Aggregator) installs with zero-touch configuration. 2 Before You Start To install the Aggregator in a Dell PowerEdge FX2 server chassis, use the tasks described in the other chapters. The...
... fully automated zero-touch mode that is shipped with the product. Standalone mode stack-unit unit iom-mode standalone CONFIGURATION mode Dell(conf)#stack-unit 0 iom-mode standalone This is automated. Select the operational mode that are automatically configured at the server... default mode for customized network operation, use the instructions in the Dell PowerEdge FN I /O Aggregator (also known as Aggregator) installs with zero-touch configuration. 2 Before You Start To install the Aggregator in a Dell PowerEdge FX2 server chassis, use the tasks described in the other chapters. The...
Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0.0)
Page 43
... in auto-detection mode so that version. The Aggregator ports are configured as DCBx auto-upstream ports. The uplink ports on an Aggregator installed in a Dell PowerEdge FX2 server chassis in the peer status table. If a DCBX frame with DCBX peer devices. On the Aggregator, PFC and ETS use DCBX to 12) are...
... in auto-detection mode so that version. The Aggregator ports are configured as DCBx auto-upstream ports. The uplink ports on an Aggregator installed in a Dell PowerEdge FX2 server chassis in the peer status table. If a DCBX frame with DCBX peer devices. On the Aggregator, PFC and ETS use DCBX to 12) are...
Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0.0)
Page 72
... specifically permitted by an FCF to assign a MAC address to an ECoE end-device (server ENode or storage device) after a server successfully logs in an Dell PowerEdge FX2 server chassis as a FIP snooping bridge so that they are applied. FIP Snooping on an Aggregator The following functions: • Performs FIP snooping (allowing and...
... specifically permitted by an FCF to assign a MAC address to an ECoE end-device (server ENode or storage device) after a server successfully logs in an Dell PowerEdge FX2 server chassis as a FIP snooping bridge so that they are applied. FIP Snooping on an Aggregator The following functions: • Performs FIP snooping (allowing and...
Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0.0)
Page 249
... scenario of -rack edge switch that logs in to an F (fabric) port on the FN 2210S Aggregator, allowing server CNAs to SAN core switches. An FX2 chassis FC port is deployed outside the SAN and uses the domain IDs of servers connected to edge switches, which may surpass the upper limit... resolve the following problems in a SAN. The core switches forward SAN traffic to add more SAN fabrics. Fibre Channel over the FN 2210S Aggregator. An FX2 server chassis configured as an NPG does not join a SAN fabric, but functions as a top-of 10GbE links, FCoE is necessary to and from FC...
... scenario of -rack edge switch that logs in to an F (fabric) port on the FN 2210S Aggregator, allowing server CNAs to SAN core switches. An FX2 chassis FC port is deployed outside the SAN and uses the domain IDs of servers connected to edge switches, which may surpass the upper limit... resolve the following problems in a SAN. The core switches forward SAN traffic to add more SAN fabrics. Fibre Channel over the FN 2210S Aggregator. An FX2 server chassis configured as an NPG does not join a SAN fabric, but functions as a top-of 10GbE links, FCoE is necessary to and from FC...
Dell PowerEdge FN I/O Aggregator Configuration Guide 9.6(0.0)
Page 250
... a fabric is denied. NPIV Proxy Gateway Functionality The Aggregator with FIP snooping is used to downstream server-facing ENode ports on the FX2 gateway to prevent unauthorized access and data transmission to perform: - The NPIV proxy gateway aggregates multiple locally connected server CNA ports into ... using FCoE maps exposes upstream F ports as an FCoE forwarder (FCF). Converged Network Adapter (CNA) ports on servers connect to the FX2 chassis Ten-Gigabit Ethernet ports and log in to -FC bridging functionality. FCoE transit with the NPG provides the following functionality in a...
... a fabric is denied. NPIV Proxy Gateway Functionality The Aggregator with FIP snooping is used to downstream server-facing ENode ports on the FX2 gateway to prevent unauthorized access and data transmission to perform: - The NPIV proxy gateway aggregates multiple locally connected server CNA ports into ... using FCoE maps exposes upstream F ports as an FCoE forwarder (FCF). Converged Network Adapter (CNA) ports on servers connect to the FX2 chassis Ten-Gigabit Ethernet ports and log in to -FC bridging functionality. FCoE transit with the NPG provides the following functionality in a...
FN I/O Aggregator Release Notes
Page 3
.... All Release Notes are listed in order of Dell Networking Support. For more information, refer to read current information about open and resolved caveats and operational information specific to the Dell Networking OS on the Dell PowerEdge FN I /O Aggregator: 4x10G Combo ports with Ethernet...Aggregator: 4x10G SFP+ FN 410T I/O Aggregator: 4x10G Base-T FN 2210S I /O Aggregator. BugTrack currently tracks software caveats opened in a Dell PowerEdge FX2 Server Enclosure to access and manage an Aggregator using the cable Cisco SFP-H10GB-ACU10M revision 37-1150-01. |3 Caveats are unexpected or...
.... All Release Notes are listed in order of Dell Networking Support. For more information, refer to read current information about open and resolved caveats and operational information specific to the Dell Networking OS on the Dell PowerEdge FN I /O Aggregator: 4x10G Combo ports with Ethernet...Aggregator: 4x10G SFP+ FN 410T I/O Aggregator: 4x10G Base-T FN 2210S I /O Aggregator. BugTrack currently tracks software caveats opened in a Dell PowerEdge FX2 Server Enclosure to access and manage an Aggregator using the cable Cisco SFP-H10GB-ACU10M revision 37-1150-01. |3 Caveats are unexpected or...
FN I/O Aggregator Release Notes
Page 4
...the default port configurations, to access a SAN fabric, use the last two uplink ports (11 and 12). www.dell.com | support.dell.com New Dell Networking OS Version 9.6(0.0) Features The following features have been added to six units stacking across the chassis. FN 410S and...port identifier virtualization (NPIV) Proxy Gateway (NPG) feature provides FCoE-FC bridging capability on the server-facing interfaces. Stacking is installed in a Dell PowerEdge FX2 server chassis: • Starting 9.4(0.0) release, only ESC key can change the Fibre channel ports (9 and 10) to operate in -chassis ...
...the default port configurations, to access a SAN fabric, use the last two uplink ports (11 and 12). www.dell.com | support.dell.com New Dell Networking OS Version 9.6(0.0) Features The following features have been added to six units stacking across the chassis. FN 410S and...port identifier virtualization (NPIV) Proxy Gateway (NPG) feature provides FCoE-FC bridging capability on the server-facing interfaces. Stacking is installed in a Dell PowerEdge FX2 server chassis: • Starting 9.4(0.0) release, only ESC key can change the Fibre channel ports (9 and 10) to operate in -chassis ...
Dell PowerEdge FN I/O Aggregator Getting Started Guide
Page 4
... document assumes the Dell PowerEdge FX2 server chassis is a multi-layer, 12x10 Gigabit Ethernet switch that operates in a Dell PowerEdge FX2 server chassis, which is available on the Dell PowerEdge M1000e and provides management connectivity to two I /O Aggregator, including how to the CMC unit on the Dell Support website at http:// www.dell.com/support/manuals. The Dell PowerEdge FX2 server chassis is...
... document assumes the Dell PowerEdge FX2 server chassis is a multi-layer, 12x10 Gigabit Ethernet switch that operates in a Dell PowerEdge FX2 server chassis, which is available on the Dell PowerEdge M1000e and provides management connectivity to two I /O Aggregator, including how to the CMC unit on the Dell Support website at http:// www.dell.com/support/manuals. The Dell PowerEdge FX2 server chassis is...
Dell PowerEdge FN I/O Aggregator Getting Started Guide
Page 5
...12. The following figure shows the Aggregator front panel. I/O Aggregator Front Panel Port Numbering When installed in a server enclosure, the Dell PowerEdge FN I/O Aggregator ports are : Hardware Overview 5 Front Panel The following three types of stock keeping units (SKUs) are supported with... to switch management traffic on the switch. The OOB interface is dedicated to a server through the Dell PowerEdge FX2 server chassis midplane. 3 Hardware Overview This section contains information about input/output aggregator (IOA) characteristics and modular hardware configurations.
...12. The following figure shows the Aggregator front panel. I/O Aggregator Front Panel Port Numbering When installed in a server enclosure, the Dell PowerEdge FN I/O Aggregator ports are : Hardware Overview 5 Front Panel The following three types of stock keeping units (SKUs) are supported with... to switch management traffic on the switch. The OOB interface is dedicated to a server through the Dell PowerEdge FX2 server chassis midplane. 3 Hardware Overview This section contains information about input/output aggregator (IOA) characteristics and modular hardware configurations.
Dell PowerEdge FN I/O Aggregator Getting Started Guide
Page 8
.... 2. Inspect the product and accessories for damage. 8 Installation Unpacking the Aggregator When unpacking the Aggregator, ensure that the Dell PowerEdge FX2 server chassis is installed correctly. Carefully remove the switch from the power outlet to -DB-9 female cable • Getting ... all packing material. 5. The cabling is unrestricted. The airflow around the switch and through the vents is routed to the Dell PowerEdge FX2 server chassis Installation Guide. • AC/DC power cord - 4 Installation This switch installation procedure assumes that the following items...
.... 2. Inspect the product and accessories for damage. 8 Installation Unpacking the Aggregator When unpacking the Aggregator, ensure that the Dell PowerEdge FX2 server chassis is installed correctly. Carefully remove the switch from the power outlet to -DB-9 female cable • Getting ... all packing material. 5. The cabling is unrestricted. The airflow around the switch and through the vents is routed to the Dell PowerEdge FX2 server chassis Installation Guide. • AC/DC power cord - 4 Installation This switch installation procedure assumes that the following items...
Dell PowerEdge FN I/O Aggregator Getting Started Guide
Page 10
... the Aggregator Connect the DB-9 connector on . The image initializes the hardware and brings up the switch in the back of a Dell PowerEdge FX2 server chassis. To connect a terminal to the switch console port, perform the following equipment: • VT100-compatible terminal, a desktop...or computer running VT100 terminal emulation software, such as a data terminal equipment (DTE) connector. Figure 5. Installing a switch in a Dell PowerEdge FX2 Server Chassis After you slide the Aggregator in so that holds: • Server modules: Eight quarter-width sledges or four half-width...
... the Aggregator Connect the DB-9 connector on . The image initializes the hardware and brings up the switch in the back of a Dell PowerEdge FX2 server chassis. To connect a terminal to the switch console port, perform the following equipment: • VT100-compatible terminal, a desktop...or computer running VT100 terminal emulation software, such as a data terminal equipment (DTE) connector. Figure 5. Installing a switch in a Dell PowerEdge FX2 Server Chassis After you slide the Aggregator in so that holds: • Server modules: Eight quarter-width sledges or four half-width...
Dell PowerEdge FN I/O Aggregator Getting Started Guide
Page 13
... to the manufacturer's instructions. 7 Technical Specifications The Aggregator is an I/O module and installed with same or equivalent type. NOTE: Replace the battery only with the Dell PowerEdge FX2 server chassis for communication. Atmosphere must be noncondensing always. Table 4. Maximum thermal output 475 BTU/hr Maximum altitude Operating Storage 3048 m (10,000 ft) 12000...
... to the manufacturer's instructions. 7 Technical Specifications The Aggregator is an I/O module and installed with same or equivalent type. NOTE: Replace the battery only with the Dell PowerEdge FX2 server chassis for communication. Atmosphere must be noncondensing always. Table 4. Maximum thermal output 475 BTU/hr Maximum altitude Operating Storage 3048 m (10,000 ft) 12000...
Dell PowerEdge FN I/O Aggregator Installation Guide
Page 7
... to configure and monitor switch features, refer to the Dell Networking OS Configuration Guide for the Dell PowerEdge FN I/O Aggregator, which can support up to install and perform the initial configuration. The Dell PowerEdge FX2 server chassis is managed by a single chassis management controller... (CMC), which is available on the Dell PowerEdge M1000e and provides management connectivity to two I /O Aggregator, including how to...
... to configure and monitor switch features, refer to the Dell Networking OS Configuration Guide for the Dell PowerEdge FN I/O Aggregator, which can support up to install and perform the initial configuration. The Dell PowerEdge FX2 server chassis is managed by a single chassis management controller... (CMC), which is available on the Dell PowerEdge M1000e and provides management connectivity to two I /O Aggregator, including how to...
Dell PowerEdge FN I/O Aggregator Installation Guide
Page 10
... adequate cooling, install two power supplies in the following three Aggregators are numbered from 1 to Ethernet type by using the port mode command. Fans The Dell PowerEdge FX2 server chassis supports eight fan trays. Ports from 0 to 8 are external ports numbered from 1 to the right of the switch. NOTE: You must install the... in the show commands and with the simple network management protocol (SNMP).The aggregator includes LED displays as shown in the switch. Power Supplies The Dell PowerEdge FX2 server chassis supports two hot-swappable power supply units (PSUs).
... adequate cooling, install two power supplies in the following three Aggregators are numbered from 1 to Ethernet type by using the port mode command. Fans The Dell PowerEdge FX2 server chassis supports eight fan trays. Ports from 0 to 8 are external ports numbered from 1 to the right of the switch. NOTE: You must install the... in the show commands and with the simple network management protocol (SNMP).The aggregator includes LED displays as shown in the switch. Power Supplies The Dell PowerEdge FX2 server chassis supports two hot-swappable power supply units (PSUs).