Hardware Owners Manual
Page 3
... 26 LAN Indicator Codes 28 Power and System Board Indicator Codes 30 Power Supply Indicator Codes 31 1400W Power Supply 31 1200W Power Supply 32 BMC Heart Beat LED 33 Post Error Code 34 Collecting System Event Log (SEL) for Investigation 34 System Event Log 38 Processor Error 38 Memory ECC...
... 26 LAN Indicator Codes 28 Power and System Board Indicator Codes 30 Power Supply Indicator Codes 31 1400W Power Supply 31 1200W Power Supply 32 BMC Heart Beat LED 33 Post Error Code 34 Collecting System Event Log (SEL) for Investigation 34 System Event Log 38 Processor Error 38 Memory ECC...
Hardware Owners Manual
Page 5
... 90 ISCSI Remote Boot 92 Active State Power Management Configuration 93 PCI Slot Configuration 94 USB Configuration 95 Security Menu 96 Server Menu...98 Set BMC LAN Configuration 100 Remote Access Configuration 101 Boot Menu ...103 Exit Menu...104 Command Line Interfaces for Setup options 105 3 Installing System Components 137 Safety...
... 90 ISCSI Remote Boot 92 Active State Power Management Configuration 93 PCI Slot Configuration 94 USB Configuration 95 Security Menu 96 Server Menu...98 Set BMC LAN Configuration 100 Remote Access Configuration 101 Boot Menu ...103 Exit Menu...104 Command Line Interfaces for Setup options 105 3 Installing System Components 137 Safety...
Hardware Owners Manual
Page 30
... Amber Solid Off Off Blinking Green Off Amber Blinking System identification indicator Steady Blue Blinking Blue Off Condition Power On (S0) BMC critical condition event in Power Off mode (S4/S5) BMC critical condition event in Power On mode (S0) IPMI via Chassis Identify Command On or ID Button Press ID On...
... Amber Solid Off Off Blinking Green Off Amber Blinking System identification indicator Steady Blue Blinking Blue Off Condition Power On (S0) BMC critical condition event in Power Off mode (S4/S5) BMC critical condition event in Power On mode (S0) IPMI via Chassis Identify Command On or ID Button Press ID On...
Hardware Owners Manual
Page 33
BMC Heart Beat LED The system board provides BMC heart beat LED (LED17) for BMC debugs. When the system AC power is green. Figure 1-26. The BMC heart beat LED is connected, the LED lights. BMC Heart Beat LED on the System Board C6220 II Figure 1-27. When BMC firmware is ready, the BMC heart beat LED blinks. BMC Heart Beat LED on the C6220 System Board 1 BMC heart beat LED 2 system board About Your System | 33
BMC Heart Beat LED The system board provides BMC heart beat LED (LED17) for BMC debugs. When the system AC power is green. Figure 1-26. The BMC heart beat LED is connected, the LED lights. BMC Heart Beat LED on the System Board C6220 II Figure 1-27. When BMC firmware is ready, the BMC heart beat LED blinks. BMC Heart Beat LED on the C6220 System Board 1 BMC heart beat LED 2 system board About Your System | 33
Hardware Owners Manual
Page 46
... 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 Event Data2 10 Event Data3 SEL Generator ID Generator ID BIOS BMC ME Windows 2008 Value AXh XXh FFh Description 01h: OEM BIOS recovery Event 01h:Start Recovery 02h:Recovery Success 03h:Load Image Fail 04h:Signed...
... 4 Event Message Format Version 5 Sensor Type 6 Sensor Number 7 Event Direction Event Type 8 Event Data1 9 Event Data2 10 Event Data3 SEL Generator ID Generator ID BIOS BMC ME Windows 2008 Value AXh XXh FFh Description 01h: OEM BIOS recovery Event 01h:Start Recovery 02h:Recovery Success 03h:Load Image Fail 04h:Signed...
Hardware Owners Manual
Page 69
... the screen by pressing the . Using the System Setup Program | 69 Internal Serial Connector as Serial Over LAN (SOL). 3 BMC SOL. Enabling and Configuring Console Redirection External Serial Port To enable SOL feature in the external serial port mode, perform the following ... the system board, see "Remote Access Configuration" on the back panel, see Figure 1-14 item 8. 2 Enter the server BIOS setup screen. 3 Enter Set BMC LAN Configuration screen and verify the following settings: Remote Access: enabled Serial port number: COM1 Serial Port Mode: 115200 8, n,...
... the screen by pressing the . Using the System Setup Program | 69 Internal Serial Connector as Serial Over LAN (SOL). 3 BMC SOL. Enabling and Configuring Console Redirection External Serial Port To enable SOL feature in the external serial port mode, perform the following ... the system board, see "Remote Access Configuration" on the back panel, see Figure 1-14 item 8. 2 Enter the server BIOS setup screen. 3 Enter Set BMC LAN Configuration screen and verify the following settings: Remote Access: enabled Serial port number: COM1 Serial Port Mode: 115200 8, n,...
Hardware Owners Manual
Page 70
... None Redirection After BIOS POST: Always Terminal Type: VT100 To do this , see "Remote Access Configuration" on page 101. BMC Serial Over LAN There are two modes of management port on the back panel, see "Remote Access Configuration" on page 101. To enable SOL feature...NIC, perform the following steps show setup process about the LAN connection and BIOS setup settings for Dedicated-NIC and Shared-NIC. 3 Enter Set BMC LAN Configuration screen and verify the following settings: Remote Access: enabled Serial port number: COM2 as SOL Serial Port...
... None Redirection After BIOS POST: Always Terminal Type: VT100 To do this , see "Remote Access Configuration" on page 101. BMC Serial Over LAN There are two modes of management port on the back panel, see "Remote Access Configuration" on page 101. To enable SOL feature...NIC, perform the following steps show setup process about the LAN connection and BIOS setup settings for Dedicated-NIC and Shared-NIC. 3 Enter Set BMC LAN Configuration screen and verify the following settings: Remote Access: enabled Serial port number: COM2 as SOL Serial Port...
Hardware Owners Manual
Page 71
...100. Note that the host and client need to sync with the host and client. 4 Enter LAN Configuration screen and verify the following settings: BMC LAN Port Configuration: Shared-NIC DHCP Enabled: Disabled or Enabled (Enabled if DHCP server support) IP Address: 192.168.001.003 ... in the mode of NIC connector 1 on the back panel, see Figure 1-14 item 5. 2 Enter the server BIOS setup screen. 3 Enter Set BMC LAN Configuration screen and verify the following steps: 1 Connect the LAN cable to have the same network section. For location of Shared-NIC, perform the...
...100. Note that the host and client need to sync with the host and client. 4 Enter LAN Configuration screen and verify the following settings: BMC LAN Port Configuration: Shared-NIC DHCP Enabled: Disabled or Enabled (Enabled if DHCP server support) IP Address: 192.168.001.003 ... in the mode of NIC connector 1 on the back panel, see Figure 1-14 item 5. 2 Enter the server BIOS setup screen. 3 Enter Set BMC LAN Configuration screen and verify the following steps: 1 Connect the LAN cable to have the same network section. For location of Shared-NIC, perform the...
Hardware Owners Manual
Page 72
Serial Port Connection List Setup Option Signal Type Remote Access Serial Port Serial Port Address Number Serial Enabled COM1 3F8h/2F8h Console Redirection Enabled COM1 2F8h/3F8h Enabled COM2 as 3F8h/2F8h BMC Serial SOL Over LAN Enabled COM2 as 2F8h/3F8h SOL Scorpion Enabled COM2 as 3F8h/2F8h Serial Over SOL LAN Enabled COM2 as 2F8h/3F8h SOL OS Setting ttyS0 ttyS1 ttyS1 ttyS0 ttyS1 ttyS0 Output Serial Port Management Port Internal Serial Connector 72 | Using the System Setup Program
Serial Port Connection List Setup Option Signal Type Remote Access Serial Port Serial Port Address Number Serial Enabled COM1 3F8h/2F8h Console Redirection Enabled COM1 2F8h/3F8h Enabled COM2 as 3F8h/2F8h BMC Serial SOL Over LAN Enabled COM2 as 2F8h/3F8h SOL Scorpion Enabled COM2 as 3F8h/2F8h Serial Over SOL LAN Enabled COM2 as 2F8h/3F8h SOL OS Setting ttyS0 ttyS1 ttyS1 ttyS0 ttyS1 ttyS0 Output Serial Port Management Port Internal Serial Connector 72 | Using the System Setup Program
Hardware Owners Manual
Page 74
.... Displays the Build date. Displays the BIOS version. Displays the asset tag of the product. Displays the eppid of the product. Note: BMC version will not present if not detected. Displays the current fan control board firmware version. Displays the processor speed. Displays total memory voltage....Displays the MAC address of the node. Option Product Name BIOS Version BIOS Build Date Service Tag Asset Tag MRC Version ME Version BMC Version VBIOS Version Fan Control Board FW ePPID NIC1 MAC Address NIC2 MAC Address Description Displays the product name. Note: Fan Control...
.... Displays the Build date. Displays the BIOS version. Displays the asset tag of the product. Displays the eppid of the product. Note: BMC version will not present if not detected. Displays the current fan control board firmware version. Displays the processor speed. Displays total memory voltage....Displays the MAC address of the node. Option Product Name BIOS Version BIOS Build Date Service Tag Asset Tag MRC Version ME Version BMC Version VBIOS Version Fan Control Board FW ePPID NIC1 MAC Address NIC2 MAC Address Description Displays the product name. Note: Fan Control...
Hardware Owners Manual
Page 95
... USB port. USB Configuration Scroll to this item and press Enter to view the following screen: Option Embedded USB Controller (Enabled default) USB Port with BMC (Enabled default) External USB Port1 (Enabled default) External USB Port2 (Enabled default) Internal USB Connector (Enabled default) Description Causes the BIOS to electrically disable / enable... users to electrically disable / enable the internal USB port which contacts to electrically disable/ enable the external USB port 2. This feature allows the users to BMC.
... USB port. USB Configuration Scroll to this item and press Enter to view the following screen: Option Embedded USB Controller (Enabled default) USB Port with BMC (Enabled default) External USB Port1 (Enabled default) External USB Port2 (Enabled default) Internal USB Connector (Enabled default) Description Causes the BIOS to electrically disable / enable... users to electrically disable / enable the internal USB port which contacts to electrically disable/ enable the external USB port 2. This feature allows the users to BMC.
Hardware Owners Manual
Page 99
...to the state which is restored, the system will power on AC Power Loss (Power On default) Power Off - BMC NIC MAC Address Displays the MAC address for BMC ROM update. Enabled - Last State - Disabled - Disables Power Button to immediate/Random/User Defined mode. NIC1 MAC Address... time to turn off system. IPMI Specification Version Displays the IPMI specification version. NIC2 MAC Address Displays the NIC2 MAC address. Set BMC LAN Configuration Inputs for IPMI driver installation. After an AC power loss, when AC power is when power was lost. ACPI SPMI Table...
...to the state which is restored, the system will power on AC Power Loss (Power On default) Power Off - BMC NIC MAC Address Displays the MAC address for BMC ROM update. Enabled - Last State - Disabled - Disables Power Button to immediate/Random/User Defined mode. NIC1 MAC Address... time to turn off system. IPMI Specification Version Displays the IPMI specification version. NIC2 MAC Address Displays the NIC2 MAC address. Set BMC LAN Configuration Inputs for IPMI driver installation. After an AC power loss, when AC power is when power was lost. ACPI SPMI Table...
Hardware Owners Manual
Page 100
... system events to view the following submenu: Option Channel Number Channel Number Status BMC LAN Port Configuration Description Displays the channel number. Set BMC LAN Configuration Select Set BMC LAN Configuration to BMC, errors include ECC/ PCI/ PCI-E/ HT...etc. Sets BMC LAN Port to generate NMI when PCI-E uncorrectable errors occur. Disables/Enables BIOS...
... system events to view the following submenu: Option Channel Number Channel Number Status BMC LAN Port Configuration Description Displays the channel number. Set BMC LAN Configuration Select Set BMC LAN Configuration to BMC, errors include ECC/ PCI/ PCI-E/ HT...etc. Sets BMC LAN Port to generate NMI when PCI-E uncorrectable errors occur. Disables/Enables BIOS...
Hardware Owners Manual
Page 101
Remote Access Configuration Select Remote Access Configuration to get LAN IP from Static/ DHCP mode. Enables or disables IPv6 internet protocol support. Sets BMC LAN Gateway address. Option (Shared-NIC default) BMC NIC IP Source (DHCP default) IP Address Subnet Mask Gateway Address IPv6 Mode (Disabled default) Description Sets BMC LAN to view the following submenu: Using the System Setup Program | 101 Sets BMC LAN subnet mask. Sets BMC LAN IP address.
Remote Access Configuration Select Remote Access Configuration to get LAN IP from Static/ DHCP mode. Enables or disables IPv6 internet protocol support. Sets BMC LAN Gateway address. Option (Shared-NIC default) BMC NIC IP Source (DHCP default) IP Address Subnet Mask Gateway Address IPv6 Mode (Disabled default) Description Sets BMC LAN to view the following submenu: Using the System Setup Program | 101 Sets BMC LAN subnet mask. Sets BMC LAN IP address.
Hardware Owners Manual
Page 106
... disk, RAID, Network (if the devices are available) 0054 N/A For the next system boot, set IP address of BMC LAN port as 10.106.42.120) Table 2-1. To change the SETUP option thru BMC memory directly: ./ipmitool raw (Example: ./ipmitool raw 0xc 1 1 3 10 106 42 120 to set the IPL priority...
... disk, RAID, Network (if the devices are available) 0054 N/A For the next system boot, set IP address of BMC LAN port as 10.106.42.120) Table 2-1. To change the SETUP option thru BMC memory directly: ./ipmitool raw (Example: ./ipmitool raw 0xc 1 1 3 10 106 42 120 to set the IPL priority...
Hardware Owners Manual
Page 122
... WOL Enables the ROW, Reboot on LAN (WOL) signal to reboot the motherboard. PCI-E Slot1 This feature will allow the users to BMC. USB PORT with BMC USB PORT with BMC Force PXE Boot only This feature will allow the users to electrically disable the internal USB port which contacts to electrically enable... S0/S3 state, when a WOL packet is a feature (ROW) which contacts to electrically disable Mezzanine Slot. Mezzanine Slot This feature will allow the users to BMC. Disables PXE to boot from PXE device.
... WOL Enables the ROW, Reboot on LAN (WOL) signal to reboot the motherboard. PCI-E Slot1 This feature will allow the users to BMC. USB PORT with BMC USB PORT with BMC Force PXE Boot only This feature will allow the users to electrically disable the internal USB port which contacts to electrically enable... S0/S3 state, when a WOL packet is a feature (ROW) which contacts to electrically disable Mezzanine Slot. Mezzanine Slot This feature will allow the users to BMC. Disables PXE to boot from PXE device.
Hardware Owners Manual
Page 123
... device. 5th Boot Device ACPI SPMI Table ACPI SPMI Table Sets CD/DVD ROM as 5th boot device. Configuration Using the System Setup Program | 123 BMC LAN Port Sets BMC LAN Port to Dedicated-NIC. Disables the ACPI SPMI Table for IPMI driver installation. Enables the ACPI SPMI Table for...
... device. 5th Boot Device ACPI SPMI Table ACPI SPMI Table Sets CD/DVD ROM as 5th boot device. Configuration Using the System Setup Program | 123 BMC LAN Port Sets BMC LAN Port to Dedicated-NIC. Disables the ACPI SPMI Table for IPMI driver installation. Enables the ACPI SPMI Table for...
Hardware Owners Manual
Page 124
... uncorrectable errors occur. 124 | Using the System Setup Program IPv6 Mode Disables IPv6 internet protocol support. Disables BIOS to BMC, errors include ECC/PCI/PCI-E/HT...etc. Sets BMC LAN to get LAN IP from Static mode. Remote access flow controls by none. Remote access flow controls by software.... IPv6 AutoConfig Enables IPv6 auto configuration. Sets BMC LAN to Shared-NIC. Token 48A3 48A4 48A5 48A6 48A7 48A8 48A9 48AA 48AB 48AC 48AD 48AE 48AF 48B0 48B1 48B2 48B3 Setup option...
... uncorrectable errors occur. 124 | Using the System Setup Program IPv6 Mode Disables IPv6 internet protocol support. Disables BIOS to BMC, errors include ECC/PCI/PCI-E/HT...etc. Sets BMC LAN to get LAN IP from Static mode. Remote access flow controls by none. Remote access flow controls by software.... IPv6 AutoConfig Enables IPv6 auto configuration. Sets BMC LAN to Shared-NIC. Token 48A3 48A4 48A5 48A6 48A7 48A8 48A9 48AA 48AB 48AC 48AD 48AE 48AF 48B0 48B1 48B2 48B3 Setup option...
Hardware Owners Manual
Page 130
...-function Enables Get OEM NetFn IANA Support BMC Watchdog Timer Commands Reset Watchdog Timer Set Watchdog Timer Get Watchdog Timer BMC Device and Messaging Commands Set BMC Global Enables Get BMC Global Enables Clear Message Flags Get Message ... (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) Code IPMI2.0 BMC 0x01 M Y 0x01 M Y 0x02 O Y 0x03 O 0x04 M Y 0x05 O Y 0x06 O Y 0x07 O Y 0x08 O Y 0x09 O Y 0x0A O Y 0x0B O Y 0x0C O Y 0x0D O Y 0x60 0x61 0x62 0x63 0x64 O Y O Y O Y...
...-function Enables Get OEM NetFn IANA Support BMC Watchdog Timer Commands Reset Watchdog Timer Set Watchdog Timer Get Watchdog Timer BMC Device and Messaging Commands Set BMC Global Enables Get BMC Global Enables Clear Message Flags Get Message ... (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) App (0x06) Code IPMI2.0 BMC 0x01 M Y 0x01 M Y 0x02 O Y 0x03 O 0x04 M Y 0x05 O Y 0x06 O Y 0x07 O Y 0x08 O Y 0x09 O Y 0x0A O Y 0x0B O Y 0x0C O Y 0x0D O Y 0x60 0x61 0x62 0x63 0x64 O Y O Y O Y...
Hardware Owners Manual
Page 134
...) 0x49 M Y Storage (0x0A) 0x5A O Storage (0x0A) 0x5B O Storage (0x0A) 0x5C O Storage (0x0A) 0x5D O LAN Device Commands Set LAN Configuration Parameters Get LAN Configuration Parameters Suspend BMC ARPs Get IP/UDP/RMCP Statistics Transport (0x0C) Transport (0x0C) Transport (0x0C) Transport (0x0C) 0x01 0x02 0x03 0x04 M Y M Y O O Serial/Modem Device Commands Set Serial/Modem...
...) 0x49 M Y Storage (0x0A) 0x5A O Storage (0x0A) 0x5B O Storage (0x0A) 0x5C O Storage (0x0A) 0x5D O LAN Device Commands Set LAN Configuration Parameters Get LAN Configuration Parameters Suspend BMC ARPs Get IP/UDP/RMCP Statistics Transport (0x0C) Transport (0x0C) Transport (0x0C) Transport (0x0C) 0x01 0x02 0x03 0x04 M Y M Y O O Serial/Modem Device Commands Set Serial/Modem...