D-Link DE-809TC Support and Manuals
Get Help and Manuals for this D-Link item
This item is in your list!
View All Support Options Below
Free D-Link DE-809TC manuals!
Problems with D-Link DE-809TC?
Ask a Question
Free D-Link DE-809TC manuals!
Problems with D-Link DE-809TC?
Ask a Question
Popular D-Link DE-809TC Manual Pages
User Guide - Page 11
10BASE-T Ethernet Mini Hubs User's Guide
1 Introduction
This User's Guide tells you how to install the following 10BASE-T Ethernet Mini Hub models: ♦ DE-809TP (9 UTP ports) ♦ DE-809TC (8 UTP ports & 1 BNC port)
Port connectors on back panel of Mini Hubs
Introduction
1
User Guide - Page 12
... cascading with nine or fewer nodes. Model DE-809TC provides eight UTP ports (eight RJ-45 connectors) and one of these ports can be part of the Mini Hubs:
♦ 9-port hubs. The BNC port on a wall.
2
Introduction The Mini Hub is a summary of the features of a larger network.
♦ Installation flexibility. one BNC port.
♦ Cascading...
User Guide - Page 19
... the AC power adapter is no power switch. There is connected to an AC power source and the hub's AC power socket.
&DXWLRQã
7R SUHYHQW GDPDJH WR \RXU KXEñ EHIRUH \RX EHJLQ ...SURGXFWV GHDOHU WR PDNH VXUH WKDW \RX XVH D SURSHU $& SRZHU DGDSWHUï
Installation
7 10BASE-T Ethernet Mini Hubs User's Guide
Connecting AC Power Adapter
The Mini Hub uses an external AC power adapter.
User Guide - Page 21
... used to a station, bridge or router. 10BASE-T Ethernet Mini Hubs User's Guide
Note that, for details).
To connect this chapter for Mini Hub model DE-809TP, UTP port labeled "9" must be in the Uplink position (see section Cascading Hubs Through UTP Cable in order to be connectable to switch between the Normal and the Uplink position. Installation
9
User Guide - Page 22
If the thin coaxial segment terminates at the hub, attach a 50-ohm terminator to the thin coaxial cable. Connect a T-connector to the BNC connector, then connect both ends of the T-connector to one end of the T-connector.
10
Installation Connecting Thin Coaxial Segment
The BNC port on Mini Hub model DE-809TC is used to connect to a thin coaxial segment.
User Guide - Page 23
.... You may also cascade the DE-809TC with any other IEEE 802.3 Ethernet standard 10BASE-T hubs equipped with BNC ports.
You may attach up to thirty nodes to cascade hubs together. Installation
11 10BASE-T Ethernet Mini Hubs User's Guide
Cascading Hubs Through Thin Coaxial Cable
The BNC port on the Mini Hub model DE-809TC can be used to a thin coaxial...
User Guide - Page 24
...trouble of crossing the UTP cable's wires. Note: Never cause a loop when you cascade hubs since this port in the Uplink position, its signal reception and transmission are connected together, the wires inside the UTP cable must be used to the port. Cascading Hubs...unpredictable results.
12
Installation See appendix A for hub cascading. This allows you use Mini Hub model DE-809TP, UTP...
User Guide - Page 26
DE-809TP
14
Installation Diagnostic LEDs & Troubleshooting
♦ Power. ◊ ON: "power good". ◊ OFF: "power bad." Check to see if the AC power adapter is properly connected, or if the correct AC power adapter is being used.
User Guide - Page 27
...). ◊ ON: Data link between (1) Mini Hub's UTP port and (2) node's or cascaded hub's UTP port is successful. ◊ OFF: (1) No data link or (2) cable disconnected. 10BASE-T Ethernet Mini Hubs User's Guide
DE-809TC
Diagnostic LEDs on front panel of the connection. For cascaded hubs, check to see if UTP cable contains crossed-over wires.
Check for service. ◊ Blinking...
User Guide - Page 28
..., or (5) unterminated segment. Note that the UTP cable between a hub port and a non-repeater node must contain straight-through wires).
16
Installation If segment is not terminated, terminate both ends with 50-ohm terminators...ON: The UTP port is being partitioned off due to (1) no problem.
♦ Partition (for BNC port). ◊ ON: The BNC port is being partitioned off due to ...
User Guide - Page 29
10BASE-T Ethernet Mini Hubs User's Guide
A
Cables, Connectors & AC Power Adapters
10BASE-T Unshielded Twisted-Pair (UTP) Cable
♦ Cable characteristics: 0.4 - 0.6 mm (22 - 26 AWG) 8-wire (only 4 wires used for 10BASE-T)
♦ ...
User Guide - Page 30
... your area. AC Power Adapters
The following lists the specifications of the AC power adapters supplied by D-Link for use an AC power adapter supplied by yourself, make sure that it complies with the Mini Hub. standard ⇒ Safety standard: BSI
AC power adapter model AD-071AB ⇒ Input power: AC 220 volts, 50...
User Guide - Page 31
10BASE-T Ethernet Mini Hubs User's Guide
⇒ Plug: German standard ⇒ Safety standard: VDE
AC Power adapter model AD-071AJ ⇒ Input power: AC 100 volts, 50-60Hz ⇒ Output power: DC 7.5 volts unregulated, 1 A ⇒ Maximum power consumption: 7.5 watts ⇒ Safety standard: Japan T-mark
Cables, Connectors & AC Power Adapters
19
User Guide - Page 32
B
Technical Specifications
DE-809TP
♦ Standard: IEEE 802.3 10BASE-T. ♦ Medium support: UTP. ♦ Number of UTP ports: 9. ♦ Number of connectors: 9 RJ-45. ♦ Cascading: Switchable straight-through/cross-wired UTP port
... Weight: 300 ±10 grams (AC power adapter excluded) ♦ Safety: UL/CSA. ♦ EMI: FCC-B, CE-B, VCCI-A, C-Tick, BCIQ
20
Technical Specifications
User Guide - Page 36
...title at installation site? †1 employee †2-9 †10-49 †50-99 †100-499 †500-999 †1000 or more
3. Would you recommend your D-Link product to support your product...;TCP/IP †DECnet †Other
4. Registration Card
Print, type or use ? †D-Link LANsmart †Novell NetWare †NetWare Lite †SCO Unix/Xenix †PC NFS †...
D-Link DE-809TC Reviews
Do you have an experience with the D-Link DE-809TC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for D-Link yet.
Earn 750 points for your review!