... UPS R1500 G2 NA/JPN/TWN rear panel...8 UPS R1500 G2 INTL rear panel ...9 Installation ...11 Precautions ...11 Preparing to install the hardware ...11 Tools required...11 Selecting a site ...11 Readying the equipment ...12 Installing the mounting rails ...12 Installing the UPS ...16 Connecting the batteries ...17...power...21 Connecting devices to the UPS ...21 Powering up the UPS ...22 Charging the UPS batteries ...22 UPS operations...23 Modes of operation...23 Standby mode ...23 Operate mode ...23 Battery mode ...24 Initiating a self-test ...24 Silencing an audible alarm ...24 Powering down the...
... UPS R1500 G2 NA/JPN/TWN rear panel...8 UPS R1500 G2 INTL rear panel ...9 Installation ...11 Precautions ...11 Preparing to install the hardware ...11 Tools required...11 Selecting a site ...11 Readying the equipment ...12 Installing the mounting rails ...12 Installing the UPS ...16 Connecting the batteries ...17...power...21 Connecting devices to the UPS ...21 Powering up the UPS ...22 Charging the UPS batteries ...22 UPS operations...23 Modes of operation...23 Standby mode ...23 Operate mode ...23 Battery mode ...24 Initiating a self-test ...24 Silencing an audible alarm ...24 Powering down the...
User Guide
Page 4
......36 Power protection specifications...37 Voltage specifications ...37 Output tolerance specifications ...37 Output feature specifications ...37 Battery specifications ...37 Battery runtime ...38 Environmental specifications ...38 Serial communications port pin assignment 38 Spares...40 Ordering spares...40 UPS ...information...41 Warranty information...42 Limited warranty ...42 $250,000 Computer Load Protection Guarantee 42 Pre-Failure Battery Warranty...42 Recommended duration of use...43 Regulatory compliance notices ...44 Regulatory compliance identification numbers 44 Federal ...
......36 Power protection specifications...37 Voltage specifications ...37 Output tolerance specifications ...37 Output feature specifications ...37 Battery specifications ...37 Battery runtime ...38 Environmental specifications ...38 Serial communications port pin assignment 38 Spares...40 Ordering spares...40 UPS ...information...41 Warranty information...42 Limited warranty ...42 $250,000 Computer Load Protection Guarantee 42 Pre-Failure Battery Warranty...42 Recommended duration of use...43 Regulatory compliance notices ...44 Regulatory compliance identification numbers 44 Federal ...
User Guide
Page 5
Disposal of waste equipment by users in private households in the European Union 46 Japanese notice ...47 BSMI notice ...48 Korean notice ...48 Battery replacement notice ...48 Power cord statement for Japan ...49 Electrostatic discharge ...50 Preventing electrostatic discharge ...50 Grounding methods to prevent electrostatic discharge 50 Acronyms and abbreviations...51 Index...52
Disposal of waste equipment by users in private households in the European Union 46 Japanese notice ...47 BSMI notice ...48 Korean notice ...48 Battery replacement notice ...48 Power cord statement for Japan ...49 Electrostatic discharge ...50 Preventing electrostatic discharge ...50 Grounding methods to prevent electrostatic discharge 50 Acronyms and abbreviations...51 Index...52
User Guide
Page 6
NOTE: To download the latest versions of UPS firmware and software. UPS front panel Item 1 2 Description Battery compartment Control buttons and LED display Component identification 6 Component identification UPS R1500 G2 overview The HP UPS R1500 G2 features a 1U rack-mount design and offers power protection for loads up to the latest versions of UPS firmware and software, see the HP website (http://www.hp.com/go/rackandpower). To benefit from the latest product enhancements, update to 1440 VA/1000 W (NA/TWN), 1200 VA/1000 W (JPN) or 1500 VA/1000 W (INTL).
NOTE: To download the latest versions of UPS firmware and software. UPS front panel Item 1 2 Description Battery compartment Control buttons and LED display Component identification 6 Component identification UPS R1500 G2 overview The HP UPS R1500 G2 features a 1U rack-mount design and offers power protection for loads up to the latest versions of UPS firmware and software, see the HP website (http://www.hp.com/go/rackandpower). To benefit from the latest product enhancements, update to 1440 VA/1000 W (NA/TWN), 1200 VA/1000 W (JPN) or 1500 VA/1000 W (INTL).
User Guide
Page 8
UPS front panel LED indicators Item 1 2 3 4 5 6 LED description Load Segment 2 Load Segment 1 General Alarm On Battery Overload Power On For more information, see "LED and audible alarm troubleshooting (on page 33)." UPS R1500 G2 NA/JPN/TWN rear panel Component identification 8
UPS front panel LED indicators Item 1 2 3 4 5 6 LED description Load Segment 2 Load Segment 1 General Alarm On Battery Overload Power On For more information, see "LED and audible alarm troubleshooting (on page 33)." UPS R1500 G2 NA/JPN/TWN rear panel Component identification 8
User Guide
Page 9
... protection) Load segment 2 (two NEMA 5-15 output receptacles for surge and battery backup protection) Voltage configuration DIP switches Serial communications port USB communications port Input power cord with NEMA 5-15 plug (BSMI approved for TWN) UPS R1500 G2 INTL rear panel Item 1 2 3 4 5 6 7 8 Description Input circuit breaker Network Transient Protector IN jack Network...
... protection) Load segment 2 (two NEMA 5-15 output receptacles for surge and battery backup protection) Voltage configuration DIP switches Serial communications port USB communications port Input power cord with NEMA 5-15 plug (BSMI approved for TWN) UPS R1500 G2 INTL rear panel Item 1 2 3 4 5 6 7 8 Description Input circuit breaker Network Transient Protector IN jack Network...
User Guide
Page 11
...: • Elevated operating ambient temperature-If the equipment is required. Installation 11 The installation of options and routine maintenance and service of the UPS and batteries. Tools required A Philips screwdriver is installed in an environment compatible with AC power products. Be sure the necessary tools and materials ("Tools required" on page...
...: • Elevated operating ambient temperature-If the equipment is required. Installation 11 The installation of options and routine maintenance and service of the UPS and batteries. Tools required A Philips screwdriver is installed in an environment compatible with AC power products. Be sure the necessary tools and materials ("Tools required" on page...
User Guide
Page 12
...reason. Install the heaviest item first, and continue to populate the rack from the bottom to its installation location. 3. Check the battery recharge date specified on overcurrent protection and supply wiring. IMPORTANT: Do not use of rack-mounted equipment should be maintained. Installation 12...extended at a time. A rack may become unstable if more than direct connections to the branch circuit, such as the use the battery if the recharge date has passed. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. • Reliable ...
...reason. Install the heaviest item first, and continue to populate the rack from the bottom to its installation location. 3. Check the battery recharge date specified on overcurrent protection and supply wiring. IMPORTANT: Do not use of rack-mounted equipment should be maintained. Installation 12...extended at a time. A rack may become unstable if more than direct connections to the branch circuit, such as the use the battery if the recharge date has passed. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. • Reliable ...
User Guide
Page 17
...°C (104°F). Installation 17 Connecting the batteries WARNING: The unit contains sealed lead-acid battery modules. This is powered down and disconnected from the unit. • Do not disassemble, crush, or puncture the batteries. • Do not short the external contacts of the batteries. • Do not immerse the batteries in water. • Do not expose...
...°C (104°F). Installation 17 Connecting the batteries WARNING: The unit contains sealed lead-acid battery modules. This is powered down and disconnected from the unit. • Do not disassemble, crush, or puncture the batteries. • Do not short the external contacts of the batteries. • Do not immerse the batteries in water. • Do not expose...
User Guide
Page 18
Connect the battery lead to the battery terminal. Attaching the UPS front bezel Installation 18
Connect the battery lead to the battery terminal. Attaching the UPS front bezel Installation 18
User Guide
Page 21
... not plug laser printers into a grounded (earthed) electrical outlet that is installed near the equipment and is plugged in, the batteries begin to the output receptacles designated for surge and battery backup is not available until the unit is an important safety feature. • Do not use the Network Transient Protector with...
... not plug laser printers into a grounded (earthed) electrical outlet that is installed near the equipment and is plugged in, the batteries begin to the output receptacles designated for surge and battery backup is not available until the unit is an important safety feature. • Do not use the Network Transient Protector with...
User Guide
Page 22
...selected output voltage to : • 90% of their capacity within 4 hours • 100% of their capacity within 24 hours Installation 22 Charging the UPS batteries With the UPS in amps, multiply the number of amps by checking that the ratings of the devices do not exceed the UPS capacity. Before...receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- • Connect devices to the output receptacles on page 23), allow the batteries to charge before supplying backup power to devices. The Power On, Load 1 and Load 2 LEDs illuminate, indicating that power is listed in Standby mode ...
...selected output voltage to : • 90% of their capacity within 4 hours • 100% of their capacity within 24 hours Installation 22 Charging the UPS batteries With the UPS in amps, multiply the number of amps by checking that the ratings of the devices do not exceed the UPS capacity. Before...receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- • Connect devices to the output receptacles on page 23), allow the batteries to charge before supplying backup power to devices. The Power On, Load 1 and Load 2 LEDs illuminate, indicating that power is listed in Standby mode ...
User Guide
Page 23
... of operation: • Standby mode (on page 23) • Operate mode (on page 23) • Battery mode (on page 24) Standby mode In Standby mode: • No power is available at the UPS output receptacles.... • The UPS charges the batteries as necessary. To place the UPS in Standby mode (on page 23). • The UPS is powered...placed in Standby mode when the UPS is in Standby mode, the UPS maintains the charge on the batteries, but no utility power is available. To place the UPS in Standby mode until an alternate mode...
... of operation: • Standby mode (on page 23) • Operate mode (on page 23) • Battery mode (on page 24) Standby mode In Standby mode: • No power is available at the UPS output receptacles.... • The UPS charges the batteries as necessary. To place the UPS in Standby mode (on page 23). • The UPS is powered...placed in Standby mode when the UPS is in Standby mode, the UPS maintains the charge on the batteries, but no utility power is available. To place the UPS in Standby mode until an alternate mode...
User Guide
Page 24
... General Alarm LED illuminates red), the alarm silences after power is restored. Powering down all connected load devices. 2. Power to discharge. Battery mode In Battery mode, the UPS supplies power without using utility power, press and hold the Test/Alarm Reset button ("UPS front panel controls" on...problem, see "LED and audible alarm troubleshooting (on page 33)." Because a portion of the self-test requires battery power, the self-test cannot be initiated if the batteries are less than 90 percent charged. Silencing an audible alarm To silence an alarm, press the Test/Alarm Reset ...
... General Alarm LED illuminates red), the alarm silences after power is restored. Powering down all connected load devices. 2. Power to discharge. Battery mode In Battery mode, the UPS supplies power without using utility power, press and hold the Test/Alarm Reset button ("UPS front panel controls" on...problem, see "LED and audible alarm troubleshooting (on page 33)." Because a portion of the self-test requires battery power, the self-test cannot be initiated if the batteries are less than 90 percent charged. Silencing an audible alarm To silence an alarm, press the Test/Alarm Reset ...
User Guide
Page 27
...batteries To replace the batteries: 1. Important battery safety information WARNING: The unit contains sealed lead-acid battery modules. Battery care and storage guidelines CAUTION: Because of the short shelf life of the batteries. • Do not immerse the batteries in water. • Do not expose to keep these batteries...: Only one will result in storage is implemented. To prevent fire or chemical burns: • Do not attempt to recharge batteries after removal from hazardous energy: • Remove watches, rings, or other metal objects. • Use tools with insulated handles...
...batteries To replace the batteries: 1. Important battery safety information WARNING: The unit contains sealed lead-acid battery modules. Battery care and storage guidelines CAUTION: Because of the short shelf life of the batteries. • Do not immerse the batteries in water. • Do not expose to keep these batteries...: Only one will result in storage is implemented. To prevent fire or chemical burns: • Do not attempt to recharge batteries after removal from hazardous energy: • Remove watches, rings, or other metal objects. • Use tools with insulated handles...
User Guide
Page 28
... a UPS for an extended period, recharge the batteries ("Charging the UPS batteries" on page 26). 3. Disconnect the battery leads. 4. Remove the UPS front bezel ("Removing the UPS front bezel" on page 22) every 6 months, and then update the battery recharge date label. Remove the UPS battery modules. UPS battery replacement procedure This component is hot-swappable and...
... a UPS for an extended period, recharge the batteries ("Charging the UPS batteries" on page 26). 3. Disconnect the battery leads. 4. Remove the UPS front bezel ("Removing the UPS front bezel" on page 22) every 6 months, and then update the battery recharge date label. Remove the UPS battery modules. UPS battery replacement procedure This component is hot-swappable and...
User Guide
Page 29
...batteries are 90 percent charged. If the installation has not been successful, the alarm beeps, the On Battery LED illuminates and the General Alarm LED flashes. IMPORTANT: Charge the batteries... for at least 24 hours before supplying backup power to devices. The batteries...within 24 hours Testing the new battery module After installing the new battery module, press the Test/Alarm Reset... in "Replacing the batteries (on page 27)," and check the battery terminal connections. The batteries charge to : ...
...batteries are 90 percent charged. If the installation has not been successful, the alarm beeps, the On Battery LED illuminates and the General Alarm LED flashes. IMPORTANT: Charge the batteries... for at least 24 hours before supplying backup power to devices. The batteries...within 24 hours Testing the new battery module After installing the new battery module, press the Test/Alarm Reset... in "Replacing the batteries (on page 27)," and check the battery terminal connections. The batteries charge to : ...
User Guide
Page 30
.... 8. The driver can be required to successfully install the converter. The System Properties screen appears. 3. Click the Port Settings tab. 2. Remove the UPS battery modules. 9. To configure a USB port to the COM 1 port on the Windows® XP Professional and Windows Server® 2003 operating systems using the HP ...
.... 8. The driver can be required to successfully install the converter. The System Properties screen appears. 3. Click the Port Settings tab. 2. Remove the UPS battery modules. 9. To configure a USB port to the COM 1 port on the Windows® XP Professional and Windows Server® 2003 operating systems using the HP ...
User Guide
Page 32
..., a chemical face shield, chemical splash goggles, and acid-resistant gloves. Properly dispose of unneutralized acid to 1 gallon of ignition. 3. Maintenance 32 Remove combustible materials and all sources of water. 5. Neutralize spilled battery acid with the special solutions contained in a drum or other suitable container. 6. Cleaning battery spills 1. WARNING: Battery acid can severely damage your eyes and skin. 2.
..., a chemical face shield, chemical splash goggles, and acid-resistant gloves. Properly dispose of unneutralized acid to 1 gallon of ignition. 3. Maintenance 32 Remove combustible materials and all sources of water. 5. Neutralize spilled battery acid with the special solutions contained in a drum or other suitable container. 6. Cleaning battery spills 1. WARNING: Battery acid can severely damage your eyes and skin. 2.
User Guide
Page 33
...No beep Troubleshooting 33 Low battery (no utility power) Low battery (no utility power) Online-UPS power capacity exceeded Overload timeout On battery-Input voltage is out of range On battery-No utility power On battery-Battery voltage condition On battery- Troubleshooting LED and audible... alarm troubleshooting Condition Power On LED (green) On Battery LED (yellow) UPS operating from utility...
...No beep Troubleshooting 33 Low battery (no utility power) Low battery (no utility power) Online-UPS power capacity exceeded Overload timeout On battery-Input voltage is out of range On battery-No utility power On battery-Battery voltage condition On battery- Troubleshooting LED and audible... alarm troubleshooting Condition Power On LED (green) On Battery LED (yellow) UPS operating from utility...