Command Reference
Page 7
... mld snooping vlan 2-195 ipv6 traffic-filter 2-197 l2protocol-tunnel 2-199 l2protocol-tunnel cos 2-202 lacp port-priority 2-203 lacp system-priority 2-205 logging event power-inline-status 2-207 logging file 2-208 mac access-group 2-210 mac access-list extended 2-212 mac address-table aging-time 2-214 mac address-table move...
... mld snooping vlan 2-195 ipv6 traffic-filter 2-197 l2protocol-tunnel 2-199 l2protocol-tunnel cos 2-202 lacp port-priority 2-203 lacp system-priority 2-205 logging event power-inline-status 2-207 logging file 2-208 mac access-group 2-210 mac access-list extended 2-212 mac address-table aging-time 2-214 mac address-table move...
Command Reference
Page 8
... (IPv6 access-list configuration) 2-292 permit (MAC access-list configuration) 2-298 police 2-301 police aggregate 2-303 policy-map 2-305 port-channel load-balance 2-308 power inline 2-310 power inline consumption 2-313 priority-queue 2-315 private-vlan 2-317 private-vlan mapping 2-320 queue-set 2-322 rcommand 2-323 remote-span 2-325 Catalyst 3560 Switch...
... (IPv6 access-list configuration) 2-292 permit (MAC access-list configuration) 2-298 police 2-301 police aggregate 2-303 policy-map 2-305 port-channel load-balance 2-308 power inline 2-310 power inline consumption 2-313 priority-queue 2-315 private-vlan 2-317 private-vlan mapping 2-320 queue-set 2-322 rcommand 2-323 remote-span 2-325 Catalyst 3560 Switch...
Command Reference
Page 9
...-map 2-359 show cluster 2-360 show cluster candidates 2-362 show cluster members 2-364 show controllers cpu-interface 2-366 show controllers ethernet-controller 2-368 show controllers power inline 2-375 show controllers tcam 2-377 show controllers utilization 2-379 show dot1q-tunnel 2-381 show dot1x 2-382 show dtp 2-386 show env 2-388 show errdisable...
...-map 2-359 show cluster 2-360 show cluster candidates 2-362 show cluster members 2-364 show controllers cpu-interface 2-366 show controllers ethernet-controller 2-368 show controllers power inline 2-375 show controllers tcam 2-377 show controllers utilization 2-379 show dot1q-tunnel 2-381 show dot1x 2-382 show dtp 2-386 show env 2-388 show errdisable...
Command Reference
Page 11
... 2-496 show mvr interface 2-498 show mvr members 2-500 show pagp 2-502 show parser macro 2-504 show policy-map 2-507 show port-security 2-509 show power inline 2-512 show sdm prefer 2-514 show setup express 2-518 show spanning-tree 2-519 show storm-control 2-526 show system mtu 2-528 show udld 2-529...
... 2-496 show mvr interface 2-498 show mvr members 2-500 show pagp 2-502 show parser macro 2-504 show policy-map 2-507 show port-security 2-509 show power inline 2-512 show sdm prefer 2-514 show setup express 2-518 show spanning-tree 2-519 show storm-control 2-526 show system mtu 2-528 show udld 2-529...
Command Reference
Page 21
... and other technical resources. Preface Obtaining Documentation • For cluster requirements, see the Release Notes for Cisco Network Assistant (not orderable but available on Cisco.com) • Cisco RPS 300 Redundant Power System Hardware Installation Guide (order number DOC-7810372=) • Cisco RPS 675 Redundant Power System Hardware Installation Guide (order number DOC-7815201=) Obtaining Documentation...
... and other technical resources. Preface Obtaining Documentation • For cluster requirements, see the Release Notes for Cisco Network Assistant (not orderable but available on Cisco.com) • Cisco RPS 300 Redundant Power System Hardware Installation Guide (order number DOC-7810372=) • Cisco RPS 675 Redundant Power System Hardware Installation Guide (order number DOC-7815201=) Obtaining Documentation...
Command Reference
Page 239
... introduced. Use the no form of this command does not disable PoE error events. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands logging event power-inline-status logging event power-inline-status Use the logging event power-inline-status interface configuration command to disable the logging of PoE status events; Displays the values in the...
... introduced. Use the no form of this command does not disable PoE error events. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands logging event power-inline-status logging event power-inline-status Use the logging event power-inline-status interface configuration command to disable the logging of PoE status events; Displays the values in the...
Command Reference
Page 342
... port. The range is configured for a port before the switch discovers the powered device. power inline {auto [max max-wattage] | never | static [max max-wattage]} no form of this configuration, when the powered device sends Cisco Discovery Protocol (CDP) messages requesting more power than 15.4 W. 2-310 Catalyst 3560 Switch Command Reference 78-16405-05 Note...
... port. The range is configured for a port before the switch discovers the powered device. power inline {auto [max max-wattage] | never | static [max max-wattage]} no form of this configuration, when the powered device sends Cisco Discovery Protocol (CDP) messages requesting more power than 15.4 W. 2-310 Catalyst 3560 Switch Command Reference 78-16405-05 Note...
Command Reference
Page 343
...settings. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands power inline If the switch denies power to a powered device (the powered device requests more than Cisco IOS Release 12.2(20)SE1, power was sometimes still applied to a PoE port even after a powered device was later connected to that ... learns through the IEEE class or by using the power inline auto or the power inline static interface configuration command, the port autonegotiates by CDP messages from the powered device. If a port has a Cisco powered device connected to a nonpowered device when it is configured...
...settings. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands power inline If the switch denies power to a powered device (the powered device requests more than Cisco IOS Release 12.2(20)SE1, power was sometimes still applied to a PoE port even after a powered device was later connected to that ... learns through the IEEE class or by using the power inline auto or the power inline static interface configuration command, the port autonegotiates by CDP messages from the powered device. If a port has a Cisco powered device connected to a nonpowered device when it is configured...
Command Reference
Page 344
power inline Chapter 2 Catalyst 3560 Switch Cisco IOS Commands Related Commands Command logging event power-inline-status show controllers power inline show power inline Description Enables the logging of the specified PoE controller. Displays the values in the registers of PoE events. Displays the PoE status for the specified PoE port or for all PoE ports. 2-312 Catalyst 3560 Switch Command Reference 78-16405-05
power inline Chapter 2 Catalyst 3560 Switch Cisco IOS Commands Related Commands Command logging event power-inline-status show controllers power inline show power inline Description Enables the logging of the specified PoE controller. Displays the values in the registers of PoE events. Displays the PoE status for the specified PoE port or for all PoE ports. 2-312 Catalyst 3560 Switch Command Reference 78-16405-05
Command Reference
Page 345
... reports a higher class than its actual consumption or does not support power classification (defaults to the default power setting. Usage Guidelines When Cisco powered devices are connected to PoE ports, the switch uses Cisco Discovery Protocol (CDP) to determine the actual power consumption of power specified by the IEEE classification for the device, regardless of the actual...
... reports a higher class than its actual consumption or does not support power classification (defaults to the default power setting. Usage Guidelines When Cisco powered devices are connected to PoE ports, the switch uses Cisco Discovery Protocol (CDP) to determine the actual power consumption of power specified by the IEEE classification for the device, regardless of the actual...
Command Reference
Page 346
...PoE status for the specified PoE port or for this release. power inline consumption Chapter 2 Catalyst 3560 Switch Cisco IOS Commands When you enter the power inline consumption default wattage or the no power inline consumption default command, this caution message appears: %CAUTION:... Interface interface-id: Misconfiguring the 'power inline consumption/allocation' command may ...
...PoE status for the specified PoE port or for this release. power inline consumption Chapter 2 Catalyst 3560 Switch Cisco IOS Commands When you enter the power inline consumption default wattage or the no power inline consumption default command, this caution message appears: %CAUTION:... Interface interface-id: Misconfiguring the 'power inline consumption/allocation' command may ...
Command Reference
Page 365
.... To use the no service password-recovery command to disable some of the functionality of the password-recovery functionality. When the button is powering up and for a second or two after the LED above port 1X turns off. Usage Guidelines As a system administrator, you agree ...point. If you like to reset the system back to enable the password-recovery mechanism (the default). Chapter 2 Catalyst 3560 Switch Cisco IOS Commands service password-recovery service password-recovery Use the service password-recovery global configuration command to the default configuration (y/n)?
.... To use the no service password-recovery command to disable some of the functionality of the password-recovery functionality. When the button is powering up and for a second or two after the LED above port 1X turns off. Usage Guidelines As a system administrator, you agree ...point. If you like to reset the system back to enable the password-recovery mechanism (the default). Chapter 2 Catalyst 3560 Switch Cisco IOS Commands service password-recovery service password-recovery Use the service password-recovery global configuration command to the default configuration (y/n)?
Command Reference
Page 407
See the "Usage Guidelines" section for Cisco technical support representatives troubleshooting the switch. The output provides information that match the specified expression. Expression in the registers of the specified Power over Ethernet (PoE) controller. For the Catalyst 3560-24PS ...appear, but the lines that contain output do not support PoE. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show controllers power inline show controllers power inline Use the show controllers power inline [instance] [ | {begin | exclude | include} expression] Syntax Description instance | ...
See the "Usage Guidelines" section for Cisco technical support representatives troubleshooting the switch. The output provides information that match the specified expression. Expression in the registers of the specified Power over Ethernet (PoE) controller. For the Catalyst 3560-24PS ...appear, but the lines that contain output do not support PoE. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show controllers power inline show controllers power inline Use the show controllers power inline [instance] [ | {begin | exclude | include} expression] Syntax Description instance | ...
Command Reference
Page 408
... or for all PoE ports. 2-376 Catalyst 3560 Switch Command Reference 78-16405-05 show controllers power inline Chapter 2 Catalyst 3560 Switch Cisco IOS Commands Examples This is an example of output from the show controllers power inline command on a switch other than a Catalyst 3560G-48PS or 3560G-24PS switch: Switch> show controllers...
... or for all PoE ports. 2-376 Catalyst 3560 Switch Command Reference 78-16405-05 show controllers power inline Chapter 2 Catalyst 3560 Switch Cisco IOS Commands Examples This is an example of output from the show controllers power inline command on a switch other than a Catalyst 3560G-48PS or 3560G-24PS switch: Switch> show controllers...
Command Reference
Page 420
...OK and the red state as a reference point. For example, if you enter this command on the Catalyst3560G-48TS, 3560G-48PS, 3560G-24TS, and 3560G-24PS switches. (Optional) Display begins with the line that matches the expression. (Optional) Display excludes lines that match the ...that contain Output are case sensitive. show env {all | fan | power | rps| temperature [status]} [ | {begin | exclude | include expression Display both fan and temperature environmental status. show env Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show env Use the show env temperature command to display the ...
...OK and the red state as a reference point. For example, if you enter this command on the Catalyst3560G-48TS, 3560G-48PS, 3560G-24TS, and 3560G-24PS switches. (Optional) Display begins with the line that matches the expression. (Optional) Display excludes lines that match the ...that contain Output are case sensitive. show env {all | fan | power | rps| temperature [status]} [ | {begin | exclude | include expression Display both fan and temperature environmental status. show env Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show env Use the show env temperature command to display the ...
Command Reference
Page 421
... the temperature is in the critical range. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show env Examples This is an example of output from the show env all command: Switch> show env all FAN is OK TEMPERATURE is OK POWER is OK RPS is AVAILABLE This is an example of output from...
... the temperature is in the critical range. Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show env Examples This is an example of output from the show env all command: Switch> show env all FAN is OK TEMPERATURE is OK POWER is OK RPS is AVAILABLE This is an example of output from...
Command Reference
Page 433
...) Display calibration properties, including high and low numbers and any alarm information. • properties-(Optional) Display speed, duplex, and inline power settings on an interface. 78-16405-05 Catalyst 3560 Switch Command Reference 2-401 The range is not available for the interface. (Optional)...private-VLAN mapping information for the specified interface or all interfaces or the specified interface, including the features and options that a non-Cisco small form-factor pluggable (SFP) module is inserted in the module slot. (Optional) Display interfaces in the command line help, ...
...) Display calibration properties, including high and low numbers and any alarm information. • properties-(Optional) Display speed, duplex, and inline power settings on an interface. 78-16405-05 Catalyst 3560 Switch Command Reference 2-401 The range is not available for the interface. (Optional)...private-VLAN mapping information for the specified interface or all interfaces or the specified interface, including the features and options that a non-Cisco small form-factor pluggable (SFP) module is inserted in the module slot. (Optional) Display interfaces in the command line help, ...
Command Reference
Page 436
...interfaces etherchannel command when port channels are configured on per port basis),tx-(4q2t) CoS rewrite: yes ToS rewrite: yes UDLD: yes Inline power: no SPAN: source/destination PortSecure: yes Dot1x: yes This is an example of ports = 0 GC = 0x00000000 HotStandBy port = ...3560 Switch Command Reference 78-16405-05 show interfaces Chapter 2 Catalyst 3560 Switch Cisco IOS Commands This is an example of output from the show interfaces gigabitethernet0/2 capabilities GigabitEthernet0/2 Model: WS-C3560-24PS Type: 10/100/1000BaseTX Speed: 10,100,1000,auto Duplex: ...
...interfaces etherchannel command when port channels are configured on per port basis),tx-(4q2t) CoS rewrite: yes ToS rewrite: yes UDLD: yes Inline power: no SPAN: source/destination PortSecure: yes Dot1x: yes This is an example of ports = 0 GC = 0x00000000 HotStandBy port = ...3560 Switch Command Reference 78-16405-05 show interfaces Chapter 2 Catalyst 3560 Switch Cisco IOS Commands This is an example of output from the show interfaces gigabitethernet0/2 capabilities GigabitEthernet0/2 Model: WS-C3560-24PS Type: 10/100/1000BaseTX Speed: 10,100,1000,auto Duplex: ...
Command Reference
Page 440
show interfaces Chapter 2 Catalyst 3560 Switch Cisco IOS Commands This is an example of output from the show interfaces interface-id pruning command: Switch# show interfaces gigibitethernet0/2 pruning Port Vlans pruned ...1-4 This is an example of output from the show interfaces gigabitethernet0/1 transceiver properties Name : Gi0/1 Administrative Speed: auto Operational Speed: auto Administrative Duplex: auto Administrative Power Inline: enable Operational Duplex: auto Administrative Auto-MDIX: off Operational Auto-MDIX: off 2-408 Catalyst 3560 Switch Command Reference 78-16405-05
show interfaces Chapter 2 Catalyst 3560 Switch Cisco IOS Commands This is an example of output from the show interfaces interface-id pruning command: Switch# show interfaces gigibitethernet0/2 pruning Port Vlans pruned ...1-4 This is an example of output from the show interfaces gigabitethernet0/1 transceiver properties Name : Gi0/1 Administrative Speed: auto Operational Speed: auto Administrative Duplex: auto Administrative Power Inline: enable Operational Duplex: auto Administrative Auto-MDIX: off Operational Auto-MDIX: off 2-408 Catalyst 3560 Switch Command Reference 78-16405-05
Command Reference
Page 441
... Low Alarm Threshold (dBm) ---------0.0 78-16405-05 Catalyst 3560 Switch Command Reference 2-409 Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show interfaces This is an example of output from the show interfaces interface-id transceiver detail command: Switch# ... Threshold (mA) --------70.0 Low Warn Threshold (mA) --------4.0 Low Alarm Threshold (mA) --------2.0 Port ------Gi0/3 Optical Transmit Power (dBm 0.0 ( -0.0) High Alarm Threshold (dBm) ----------0.0 High Warn Threshold (dBm) ---------0.0 Low Warn Threshold (dBm) ---------0.0 Low Alarm Threshold (dBm) ...
... Low Alarm Threshold (dBm) ---------0.0 78-16405-05 Catalyst 3560 Switch Command Reference 2-409 Chapter 2 Catalyst 3560 Switch Cisco IOS Commands show interfaces This is an example of output from the show interfaces interface-id transceiver detail command: Switch# ... Threshold (mA) --------70.0 Low Warn Threshold (mA) --------4.0 Low Alarm Threshold (mA) --------2.0 Port ------Gi0/3 Optical Transmit Power (dBm 0.0 ( -0.0) High Alarm Threshold (dBm) ----------0.0 High Warn Threshold (dBm) ---------0.0 Low Warn Threshold (dBm) ---------0.0 Low Alarm Threshold (dBm) ...