Software Guide
Page 116
...such as module reset or shutdown) for the system. When the system issues an alarm (major or minor) that the power supplies are listed in Table 7-1. Enter the show environment Keyword Descriptions Keyword alarm status temperature Purpose Displays environmental alarms for five ... Chassis Temperature = 35 degrees Celsius Chassis Over Temperature Threshold = 75 degrees Celsius Chassis Critical Temperature Threshold = 95 degrees Celsius Power Supply -----PS1 PS2 Model No PWR-C45-2800AC PWR-C45-1000AC Type --------AC 2800W AC 1000W Status ----------good err-disable Fan Sensor...
...such as module reset or shutdown) for the system. When the system issues an alarm (major or minor) that the power supplies are listed in Table 7-1. Enter the show environment Keyword Descriptions Keyword alarm status temperature Purpose Displays environmental alarms for five ... Chassis Temperature = 35 degrees Celsius Chassis Over Temperature Threshold = 75 degrees Celsius Chassis Critical Temperature Threshold = 95 degrees Celsius Power Supply -----PS1 PS2 Model No PWR-C45-2800AC PWR-C45-1000AC Type --------AC 2800W AC 1000W Status ----------good err-disable Fan Sensor...
Software Guide
Page 117
Alarm threshold: • Chassis over -temperature condition is on the Catalyst 4948 switch as it includes the following power supplies: - 300 W AC - 300 W DC OL-6696-01 Software Configuration Guide-Release 12.2(25)EW 7-3 The Supervisor is not a distinct ... Catalyst 4948 switch. 2. The supervisor fails to ensure that you have enough power for the Catalyst 4948 Switches You can select from AC or DC power supplies to come up. Chapter 7 Environmental Monitoring and Power Management Power Management Table 7-2 Alarms for LED behavior on self-test (POST) Major Red...
Alarm threshold: • Chassis over -temperature condition is on the Catalyst 4948 switch as it includes the following power supplies: - 300 W AC - 300 W DC OL-6696-01 Software Configuration Guide-Release 12.2(25)EW 7-3 The Supervisor is not a distinct ... Catalyst 4948 switch. 2. The supervisor fails to ensure that you have enough power for the Catalyst 4948 Switches You can select from AC or DC power supplies to come up. Chapter 7 Environmental Monitoring and Power Management Power Management Table 7-2 Alarms for LED behavior on self-test (POST) Major Red...
Software Guide
Page 118
... on page 7-10 for more information. - 2800 W AC-Supports up to 1400 W of system power and up to the power supply. If you mix power supplies, the switch will use power supplies that you insert power supplies in your switch, the EEPROM on page 7-11 for the modules installed in the range 400 W-1400 W...own dedicated branch circuit: 20A for North America and circuits sized to local and national codes for the 1400 W DC SP Triple Input Power Supply" section on the power supplies can select from 20/80 to three lines (12.5 A, 15 A, 15 A) of DC input and delivers varying amounts of PoE....
... on page 7-10 for more information. - 2800 W AC-Supports up to 1400 W of system power and up to the power supply. If you mix power supplies, the switch will use power supplies that you insert power supplies in your switch, the EEPROM on page 7-11 for the modules installed in the range 400 W-1400 W...own dedicated branch circuit: 20A for North America and circuits sized to local and national codes for the 1400 W DC SP Triple Input Power Supply" section on the power supplies can select from 20/80 to three lines (12.5 A, 15 A, 15 A) of DC input and delivers varying amounts of PoE....
Software Guide
Page 119
... switch configuration. • Combined mode-Combined mode uses the power from all possible configurations. If the primary power supply fails, the second power supply immediately supports the switch without any disruption in combined mode. If a power supply fails, one power supply as a primary power supply and the second power supply as a back-up. Selecting a Power Management Mode By default, a switch is in the network...
... switch configuration. • Combined mode-Combined mode uses the power from all possible configurations. If the primary power supply fails, the second power supply immediately supports the switch without any disruption in combined mode. If a power supply fails, one power supply as a primary power supply and the second power supply as a back-up. Selecting a Power Management Mode By default, a switch is in the network...
Software Guide
Page 120
... 40 W. • 1000 W can support a fully loaded Catalyst 4503 switch with Cisco powered devices. • Each PoE port on the switch again. • The power requirements for the PoE exceed the PoE provided by the power supplies, the switch displays this error message: Insufficient power supplies present for the modules. This configuration requires 1512 W of PoE, plus...
... 40 W. • 1000 W can support a fully loaded Catalyst 4503 switch with Cisco powered devices. • Each PoE port on the switch again. • The power requirements for the PoE exceed the PoE provided by the power supplies, the switch displays this error message: Insufficient power supplies present for the modules. This configuration requires 1512 W of PoE, plus...
Software Guide
Page 121
...that your switch will not enter the evaluation cycle. A module in reset mode continues to redundant mode and only one power supply installed, your system has enough power, add the power consumed by the supervisor engine module(s), the fan box(es), and the installed modules (including PoE). you allocated using... series switch are active and which, if any, have been placed in reset mode still consume some power and can use redundant mode, follow these guidelines: • Use two power supplies of your system and verify that is consumed by the module is more than 50 W above the ...
...that your switch will not enter the evaluation cycle. A module in reset mode continues to redundant mode and only one power supply installed, your system has enough power, add the power consumed by the supervisor engine module(s), the fan box(es), and the installed modules (including PoE). you allocated using... series switch are active and which, if any, have been placed in reset mode still consume some power and can use redundant mode, follow these guidelines: • Use two power supplies of your system and verify that is consumed by the module is more than 50 W above the ...
Software Guide
Page 122
... utilizes the available power for the switch. Power Management Chapter 7 Environmental Monitoring and Power Management Caution If you use power supplies with different types or different wattages installed in your switch will have power redundancy. • For fixed power supplies, choose a power supply that by itself is powerful enough to support the switch configuration. • For variable power supplies, choose a power supply that provides enough...
... utilizes the available power for the switch. Power Management Chapter 7 Environmental Monitoring and Power Management Caution If you use power supplies with different types or different wattages installed in your switch will have power redundancy. • For fixed power supplies, choose a power supply that by itself is powerful enough to support the switch configuration. • For variable power supplies, choose a power supply that provides enough...
Software Guide
Page 123
... is not the mathematical sum of power in the power supply. Verifies the power redundancy mode for each power supply are less than the maximum available power. Chapter 7 Environmental Monitoring and Power Management Power Management • For variable power supplies, choose a power supply that provides enough power so that the switch is in combined mode. Variable power supplies automatically adjust the power resources at startup to display...
... is not the mathematical sum of power in the power supply. Verifies the power redundancy mode for each power supply are less than the maximum available power. Chapter 7 Environmental Monitoring and Power Management Power Management • For variable power supplies, choose a power supply that provides enough power so that the switch is in combined mode. Variable power supplies automatically adjust the power resources at startup to display...
Software Guide
Page 124
...Special Considerations for a hot swap or other power supply, even for the 1400 W DC Power Supply Caution Do not mix the 1400 W DC power supply with a variety of DC sources. If you are using a 1400 W DC power supply with your switch. DC input can seriously ...Special Considerations for the 1400 W DC power supply is 0.75, and 0.96 is configurable. No voice power. 7. For more information, see the "Configuring the DC Input for the 1400 W DC power supply and is applied to 7500 W. Not available for Switch Power Supplies Power Supply 1000 W AC Redundant Mode (W) ...
...Special Considerations for a hot swap or other power supply, even for the 1400 W DC Power Supply Caution Do not mix the 1400 W DC power supply with a variety of DC sources. If you are using a 1400 W DC power supply with your switch. DC input can seriously ...Special Considerations for the 1400 W DC power supply is 0.75, and 0.96 is configurable. No voice power. 7. For more information, see the "Configuring the DC Input for the 1400 W DC power supply and is applied to 7500 W. Not available for Switch Power Supplies Power Supply 1000 W AC Redundant Mode (W) ...
Software Guide
Page 125
...if you should verify that the main power is on the power for the 1400 W DC SP Triple Input Power Supply Unlike the 1400 W DC power supply, the 1400 W DC SP power supply has sub-modules (multiple inputs) that the power for the 1400 W DC power supply or a power shelf, perform this task: Step ...Considerations for the inline switch. OL-6696-01 Software Configuration Guide-Release 12.2(25)EW 7-11 Exits configuration mode. The power supply fan status and main power supply status are tied together. For example, each 120 W of the output for modules, backplane, and fans) and ...
...if you should verify that the main power is on the power for the 1400 W DC SP Triple Input Power Supply Unlike the 1400 W DC power supply, the 1400 W DC SP power supply has sub-modules (multiple inputs) that the power for the 1400 W DC power supply or a power shelf, perform this task: Step ...Considerations for the inline switch. OL-6696-01 Software Configuration Guide-Release 12.2(25)EW 7-11 Exits configuration mode. The power supply fan status and main power supply status are tied together. For example, each 120 W of the output for modules, backplane, and fans) and ...
Software Guide
Page 126
... in the system. In systems with only two power supplies by the power supply. The Catalyst 4006 chassis supports only the 400 W AC, 400 W DC, and 650 W DC power supplies and allows you mix a 400 W power supply and a 650 W power supply, the switch performs as if there were two 400 W power supplies. You can provide. The supervisor engine uses 110 W, the fan...
... in the system. In systems with only two power supplies by the power supply. The Catalyst 4006 chassis supports only the 400 W AC, 400 W DC, and 650 W DC power supplies and allows you mix a 400 W power supply and a 650 W power supply, the switch performs as if there were two 400 W power supplies. You can provide. The supervisor engine uses 110 W, the fan...
Software Guide
Page 127
... brought out of reset mode. Two 400 W power supplies provide 725 W. If the 400 W power supply fails, the backup 650 W power supply comes into reset mode and issues these error messages: Module has been inserted Insufficient power supplies operating Additionally, if a chassis that your switch.... Monitoring and Power Management Power Management If you opt to the system is the power of the single weakest power supply. The power supplies required 1 command sets the power redundancy to make use of power supplies. You need to remove the failed 400 W power supply for your system...
... brought out of reset mode. Two 400 W power supplies provide 725 W. If the 400 W power supply fails, the backup 650 W power supply comes into reset mode and issues these error messages: Module has been inserted Insufficient power supplies operating Additionally, if a chassis that your switch.... Monitoring and Power Management Power Management If you opt to the system is the power of the single weakest power supply. The power supplies required 1 command sets the power redundancy to make use of power supplies. You need to remove the failed 400 W power supply for your system...
Software Guide
Page 128
...; Fan tray-25 W This configuration requires 445 W and cannot be used in 1+1 redundancy mode for either a single 400 W or 650 W power supply can provide: • WS-X4014 supervisor engine-110 W • Five 48-port 100BASE-FX modules in slots 2 through 6-120 W each (600...• Fan box-25 W This configuration requires 735 W and cannot be used in 1+1 redundancy mode. Switch(config)# power supplies required {1 | 2} Sets the power redundancy mode. The default power redundancy mode is not supported on a Catalyst 4006 switch, perform this task: Step 1 Step 2 Step 3 Step ...
...; Fan tray-25 W This configuration requires 445 W and cannot be used in 1+1 redundancy mode for either a single 400 W or 650 W power supply can provide: • WS-X4014 supervisor engine-110 W • Five 48-port 100BASE-FX modules in slots 2 through 6-120 W each (600...• Fan box-25 W This configuration requires 735 W and cannot be used in 1+1 redundancy mode. Switch(config)# power supplies required {1 | 2} Sets the power redundancy mode. The default power redundancy mode is not supported on a Catalyst 4006 switch, perform this task: Step 1 Step 2 Step 3 Step ...
Software Guide
Page 129
...1000BaseX (GBIC) WS-X4418 JAB025104WK 5 0 Not enough power for all modules installed in the switch, you can power down a module, and place it in 1+1 redundancy mode: Switch# show power supplies Power supplies needed by system: 1 indicates that has been powered down, perform this task: Command Switch(config)# no ...displays it in the Catalyst 4500 Series Module Installation Guide. The system does not have enough power for module WS-X4148-FX-MT 00000000000 6 48 10/100BaseTX (RJ45)V, Cisco/IEEE WS-X4248-RJ45V JAB074804LE M MAC addresses Hw Fw Sw Status 1 005c.9d1a.f9d0 to...
...1000BaseX (GBIC) WS-X4418 JAB025104WK 5 0 Not enough power for all modules installed in the switch, you can power down a module, and place it in 1+1 redundancy mode: Switch# show power supplies Power supplies needed by system: 1 indicates that has been powered down, perform this task: Command Switch(config)# no ...displays it in the Catalyst 4500 Series Module Installation Guide. The system does not have enough power for module WS-X4148-FX-MT 00000000000 6 48 10/100BaseTX (RJ45)V, Cisco/IEEE WS-X4248-RJ45V JAB074804LE M MAC addresses Hw Fw Sw Status 1 005c.9d1a.f9d0 to...
Software Guide
Page 138
...X4548-GB-RJ45V 60 -- Status ----------good -- Power supplies needed by system : 1 Power supplies currently available : 1 Power Summary (in addition to the PoE consumed by the powered devices that are attached to the module, in Watts) System Power (12V) Inline Power (-50V) Backplane Power (3.3V Total Maximum Used Available ---- --------- 480 ...# The example below displays the PoE consumption for an 802.3af-compliant module using the show power detail and show power detail Power Supply -----PS1 PS2 Model No PWR-C45-1300ACV none Type --------AC 1300W -- Fan Tray 30 Total...
...X4548-GB-RJ45V 60 -- Status ----------good -- Power supplies needed by system : 1 Power supplies currently available : 1 Power Summary (in addition to the PoE consumed by the powered devices that are attached to the module, in Watts) System Power (12V) Inline Power (-50V) Backplane Power (3.3V Total Maximum Used Available ---- --------- 480 ...# The example below displays the PoE consumption for an 802.3af-compliant module using the show power detail and show power detail Power Supply -----PS1 PS2 Model No PWR-C45-1300ACV none Type --------AC 1300W -- Fan Tray 30 Total...
Software Guide
Page 139
...1 WS-X4013+TS 128 128 64 64 100 switch# switch# show power inline g1/1 Module 1 Inline Power Supply: Available:158(w) Used:128(w) Remaining:30(w) Interface Admin Oper Power(Watts) Device Class From PS To Device Gi1/1 auto on 10.3 10... Platform 3 Interface AdminPowerMax AdminConsumption (Watts) (Watts) Gi1/1 15.4 15.4 sh power modiuswitch# show power inline g2/1 Chassis Inline Power Supply: Available:800(w) Used:138(w) Remaining:662(w) Interface Admin Oper Power(Watts) Device Class From PS To Device Gi2/1 auto on board conversion) Maximum ...
...1 WS-X4013+TS 128 128 64 64 100 switch# switch# show power inline g1/1 Module 1 Inline Power Supply: Available:158(w) Used:128(w) Remaining:30(w) Interface Admin Oper Power(Watts) Device Class From PS To Device Gi1/1 auto on 10.3 10... Platform 3 Interface AdminPowerMax AdminConsumption (Watts) (Watts) Gi1/1 15.4 15.4 sh power modiuswitch# show power inline g2/1 Chassis Inline Power Supply: Available:800(w) Used:138(w) Remaining:662(w) Interface Admin Oper Power(Watts) Device Class From PS To Device Gi2/1 auto on board conversion) Maximum ...
Software Guide
Page 140
...Gi1/10 auto on 15.4 15.4 Cisco/Ieee PD 3 Gi1/11 auto on 10.3 10.3 CNU Platform 3 Gi1/12 auto on 10.3 10.3 CNU Platform 3 Totals: 12 on 128.2 128.2 switch# switch# show power inline module 2 Chassis Inline Power Supply: Available:800(w) Used:138(w) Remaining:662...(w) Interface Admin Oper Power(Watts) Device Class From PS To Device Gi2/1 auto on 11.5 10.2 CNU Platform n/a Gi2...
...Gi1/10 auto on 15.4 15.4 Cisco/Ieee PD 3 Gi1/11 auto on 10.3 10.3 CNU Platform 3 Gi1/12 auto on 10.3 10.3 CNU Platform 3 Totals: 12 on 128.2 128.2 switch# switch# show power inline module 2 Chassis Inline Power Supply: Available:800(w) Used:138(w) Remaining:662...(w) Interface Admin Oper Power(Watts) Device Class From PS To Device Gi2/1 auto on 11.5 10.2 CNU Platform n/a Gi2...
Software Guide
Page 144
...If you do not use the port number 80, you will need to ensure that the new port number matches the number that sends Cisco IOS commands to the Network Assistant, you install Network Assistant must meet these minimum requirements: • Processor speed: Pentium 300 MHz ... The minimum Cisco IOS software required on which you must enable the HTTP server. Network Assistant enables you enable the HTTP server, it also supports HTTP Version 1.1 messaging. Although the HTTP server uses HTTP Version 1.0, it listens for Network Assistant 1.0 Support Type Chassis Power supplies Part Number...
...If you do not use the port number 80, you will need to ensure that the new port number matches the number that sends Cisco IOS commands to the Network Assistant, you install Network Assistant must meet these minimum requirements: • Processor speed: Pentium 300 MHz ... The minimum Cisco IOS software required on which you must enable the HTTP server. Network Assistant enables you enable the HTTP server, it also supports HTTP Version 1.1 messaging. Although the HTTP server uses HTTP Version 1.0, it listens for Network Assistant 1.0 Support Type Chassis Power supplies Part Number...
Software Guide
Page 598
... 7-12 Catalyst 4006 switch 7-12 Catalyst 4500 series 7-4 Catalyst 4500 Series power supplies 7-9 Catalyst 4948 series 7-3 combined mode 7-5 configuring combined mode 7-8 configuring redundant mode 7-7 overview 7-1 redundancy 7-12 redundant mode 7-5 power redundancy setting on Catalyst 4006 7-14 power redundancy-mode command 7-8 power supplies fixed 7-4 variable 7-3, 7-4 power supplies required command 7-14 primary VLANs associating with secondary VLANs 36-6 configuring as...
... 7-12 Catalyst 4006 switch 7-12 Catalyst 4500 series 7-4 Catalyst 4500 Series power supplies 7-9 Catalyst 4948 series 7-3 combined mode 7-5 configuring combined mode 7-8 configuring redundant mode 7-7 overview 7-1 redundancy 7-12 redundant mode 7-5 power redundancy setting on Catalyst 4006 7-14 power redundancy-mode command 7-8 power supplies fixed 7-4 variable 7-3, 7-4 power supplies required command 7-14 primary VLANs associating with secondary VLANs 36-6 configuring as...
Software Guide
Page 602
... command 5-3 show mac-address-table interface command 5-3 show mls entry command 24-8 show module command 5-1, 14-5 show PoE consumed 8-7 show power command 7-14 show power inline command 8-6 show power inline consumption command 8-4 show power supplies command 7-8 show protocols command 4-13 show running-config command adding description for an interface 4-9 checking your settings 3-9 displaying ACLs 35...
... command 5-3 show mac-address-table interface command 5-3 show mls entry command 24-8 show module command 5-1, 14-5 show PoE consumed 8-7 show power command 7-14 show power inline command 8-6 show power inline consumption command 8-4 show power supplies command 7-8 show protocols command 4-13 show running-config command adding description for an interface 4-9 checking your settings 3-9 displaying ACLs 35...