RJO20 Owner s Manual - English
Page 1
The Chamberlain Group, Inc. 300 Windsor Drive Oak Brook, IL 60523 For advanced or customized adjustments, ...unless the Protector System® and cable tension monitor are required to ensure safe operation. • This garage door opener is ONLY compatible with myQ® accessories. • The model number label is NOT intended for use on low ...headroom tracks with outside pickup drum or garage doors utilizing extension springs. Wall Mount Garage Door Opener Model RJO20 For Residential Use Install On Sectional Doors With Torsion Assemblies Only This product is located behind the hinged ...
The Chamberlain Group, Inc. 300 Windsor Drive Oak Brook, IL 60523 For advanced or customized adjustments, ...unless the Protector System® and cable tension monitor are required to ensure safe operation. • This garage door opener is ONLY compatible with myQ® accessories. • The model number label is NOT intended for use on low ...headroom tracks with outside pickup drum or garage doors utilizing extension springs. Wall Mount Garage Door Opener Model RJO20 For Residential Use Install On Sectional Doors With Torsion Assemblies Only This product is located behind the hinged ...
RJO20 Owner s Manual - English
Page 2
...System 24 Test the Power Door Lock 25 Test the Emergency Release........... 25 Test Cable Tension Monitor 25 OPERATION 26 Using Your Garage Door Opener..... 26 Using the Door Control (myQ® Control Panel 27 Using the Remote Control 28 PROGRAMMING 29 To Add a Remote Control, ...Keypad, or myQ® Enabled Accessories 29 Reprogramming Remote Light or Additional Light 30 HomeLink 30 Chamberlain Internet Gateway ....... 31 To Erase All Codes From the Door Control (myQ® Control Panel) Memory 31 MAINTENANCE 32 Care of Your ...
...System 24 Test the Power Door Lock 25 Test the Emergency Release........... 25 Test Cable Tension Monitor 25 OPERATION 26 Using Your Garage Door Opener..... 26 Using the Door Control (myQ® Control Panel 27 Using the Remote Control 28 PROGRAMMING 29 To Add a Remote Control, ...Keypad, or myQ® Enabled Accessories 29 Reprogramming Remote Light or Additional Light 30 HomeLink 30 Chamberlain Internet Gateway ....... 31 To Erase All Codes From the Door Control (myQ® Control Panel) Memory 31 MAINTENANCE 32 Care of Your ...
RJO20 Owner s Manual - English
Page 3
...High Lift Sectional Door Roller Safety Reversing Sensor Torsion Springs Torsion Bar Definition Acts as you prepare and install your garage door opener. Drums are NOT compatible with multiple panels that slide along the horizontal section of the track and extend from entering the ...the back hang. Extension springs are typically located above the garage door. Consult a trained door systems technician if you can easily open and close the door by hand. Track Track Torsion bar Electrical outlet Center bearing plate Torsion springs Sectional door Roller Hinge Drum ...
...High Lift Sectional Door Roller Safety Reversing Sensor Torsion Springs Torsion Bar Definition Acts as you prepare and install your garage door opener. Drums are NOT compatible with multiple panels that slide along the horizontal section of the track and extend from entering the ...the back hang. Extension springs are typically located above the garage door. Consult a trained door systems technician if you can easily open and close the door by hand. Track Track Torsion bar Electrical outlet Center bearing plate Torsion springs Sectional door Roller Hinge Drum ...
RJO20 Owner s Manual - English
Page 4
...-15 cm) diameter. • 3-3.9 inch (7.6-9.9 cm) diameter drums may not work properly. . Contact a qualified electrician if you can install the garage door opener on doors up to 430 lbs (194kgs). Torsion bar and torsion springs: • Torsion bar is compatible with 2-1/2" door (6.4 cm) Side view of torsion...81 cm) past the bearing plate and be used on either the left or the right side of the installation area for the opener. Use this opener to see if your torsion bar, power source and/or drums do not meet the requirements, contact a trained door systems technician...
...-15 cm) diameter. • 3-3.9 inch (7.6-9.9 cm) diameter drums may not work properly. . Contact a qualified electrician if you can install the garage door opener on doors up to 430 lbs (194kgs). Torsion bar and torsion springs: • Torsion bar is compatible with 2-1/2" door (6.4 cm) Side view of torsion...81 cm) past the bearing plate and be used on either the left or the right side of the installation area for the opener. Use this opener to see if your torsion bar, power source and/or drums do not meet the requirements, contact a trained door systems technician...
RJO20 Owner s Manual - English
Page 5
... a trained door systems technician if garage door binds, sticks, or is out of balance, contact a trained door systems technician BEFORE you install this opener. 5 Prepare your door binds, sticks, or is out of which are under EXTREME tension. • Disable ALL locks and remove ALL ropes connected... to garage door BEFORE installing and operating garage door opener to avoid entanglement. Release the door. Remove any ropes connected to avoid malfunction and damage. Check the seal on the bottom of the...
... a trained door systems technician if garage door binds, sticks, or is out of balance, contact a trained door systems technician BEFORE you install this opener. 5 Prepare your door binds, sticks, or is out of which are under EXTREME tension. • Disable ALL locks and remove ALL ropes connected... to garage door BEFORE installing and operating garage door opener to avoid entanglement. Release the door. Remove any ropes connected to avoid malfunction and damage. Check the seal on the bottom of the...
RJO20 Owner s Manual - English
Page 6
...throughout this manual are for reference only and your product may look different. Collar with Set Screws Mounting Bracket Garage Door Opener NOT SHOWN: Safety labels and literature Cable Tension Monitor with Wire Remote Light with Hardware Bag The Protector System®...Wire Power Door Lock with Wire and Connector 132A2505 TOP DRILL 5/16" DRILL 3/4" DRILL 5/16" Lock Template Safety Reversing Sensor Bracket (2) Chamberlain Internet Gateway ACCESSORIES White & White/Red Wire Door Control (myQ® Control Panel) Model 041A7928-3 3-Button Premium Remote Control Model 953ESTD (1)...
...throughout this manual are for reference only and your product may look different. Collar with Set Screws Mounting Bracket Garage Door Opener NOT SHOWN: Safety labels and literature Cable Tension Monitor with Wire Remote Light with Hardware Bag The Protector System®...Wire Power Door Lock with Wire and Connector 132A2505 TOP DRILL 5/16" DRILL 3/4" DRILL 5/16" Lock Template Safety Reversing Sensor Bracket (2) Chamberlain Internet Gateway ACCESSORIES White & White/Red Wire Door Control (myQ® Control Panel) Model 041A7928-3 3-Button Premium Remote Control Model 953ESTD (1)...
RJO20 Owner s Manual - English
Page 7
Used to position the garage door opener during installation and for testing the safety reversing sensors if installed on the wall or floor. 7 Alternate floor mounting of the following items: • Wood ...
Used to position the garage door opener during installation and for testing the safety reversing sensors if installed on the wall or floor. 7 Alternate floor mounting of the following items: • Wood ...
RJO20 Owner s Manual - English
Page 8
...when required and could be made by a trained door systems technician BEFORE installing garage door opener. 4. Disable ALL locks and remove ALL ropes connected to door BEFORE installing garage door opener to do so. 8. NEVER wear watches, rings or loose clothing while installing or...Cutters Wire Strippers Stepladder Claw Hammer 1/4", 5/16" and 3/8" Sockets and Wrench with vehicles to avoid accidental release. 7. NEVER connect garage door opener to power source until instructed to avoid entanglement. 5. Where possible, install the door operator 7 feet or more above the floor. 6. Mount...
...when required and could be made by a trained door systems technician BEFORE installing garage door opener. 4. Disable ALL locks and remove ALL ropes connected to door BEFORE installing garage door opener to do so. 8. NEVER wear watches, rings or loose clothing while installing or...Cutters Wire Strippers Stepladder Claw Hammer 1/4", 5/16" and 3/8" Sockets and Wrench with vehicles to avoid accidental release. 7. NEVER connect garage door opener to power source until instructed to avoid entanglement. 5. Where possible, install the door operator 7 feet or more above the floor. 6. Mount...
RJO20 Owner s Manual - English
Page 9
... Collar Mounting bracket Socket Wrench 9 The door may not reverse correctly or limits may be lost due to the same side of the garage door opener as the collar, using screws provided. on either side of mounting bracket to collar slip. Loosely attach slotted side of the door; Slide the ...collar onto the garage door opener shaft until it stops. 3. Position the collar so the screws are for installation on the left side. 1. Loosen the preset collar screws with the...
... Collar Mounting bracket Socket Wrench 9 The door may not reverse correctly or limits may be lost due to the same side of the garage door opener as the collar, using screws provided. on either side of mounting bracket to collar slip. Loosely attach slotted side of the door; Slide the ...collar onto the garage door opener shaft until it stops. 3. Position the collar so the screws are for installation on the left side. 1. Loosen the preset collar screws with the...
RJO20 Owner s Manual - English
Page 10
...at a right angle to the torsion bar to door .25" min. An unbalanced garage door might NOT reverse when required. • Garage door opener MUST be parallel to avoid premature wear on drywall, the mounting bracket MUST be used if mounting bracket into masonry. • NEVER try to ...the door. YOU WILL NEED Screw 14-10x2" (2) Mounting Bracket 10 Use a level to align the garage door opener parallel to loosen, move or adjust garage door, springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension. • ALWAYS...
...at a right angle to the torsion bar to door .25" min. An unbalanced garage door might NOT reverse when required. • Garage door opener MUST be parallel to avoid premature wear on drywall, the mounting bracket MUST be used if mounting bracket into masonry. • NEVER try to ...the door. YOU WILL NEED Screw 14-10x2" (2) Mounting Bracket 10 Use a level to align the garage door opener parallel to loosen, move or adjust garage door, springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension. • ALWAYS...
RJO20 Owner s Manual - English
Page 11
... the marked locations. If installing on the torsion bar. This is normal. 11 Drill through metal door rail plates if necessary. 7. Slide the garage door opener back onto the torsion bar until pilot holes align with the bar. For a hollow torsion bar, tighten screws 3/4 - 1 full turn after making contact with the... being out-of-round, the operator may wobble during operation. Set screws (Torsion bar) Screws 14-10x2" Mounting Bracket NOTE: Due to the garage door opener. Use the 14‑10x2" screws to secure the mounting bracket to the wall.
... the marked locations. If installing on the torsion bar. This is normal. 11 Drill through metal door rail plates if necessary. 7. Slide the garage door opener back onto the torsion bar until pilot holes align with the bar. For a hollow torsion bar, tighten screws 3/4 - 1 full turn after making contact with the... being out-of-round, the operator may wobble during operation. Set screws (Torsion bar) Screws 14-10x2" Mounting Bracket NOTE: Due to the garage door opener. Use the 14‑10x2" screws to secure the mounting bracket to the wall.
RJO20 Owner s Manual - English
Page 12
... the floor, and avoid contact with a match or lighter to prevent unraveling. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle to prevent slipping. 2. Thread the other end of the ...) 12 Adjust rope length so the handle is within 10 feet (3.05 m) of garage door opener with an overhand knot. Determine where to avoid accidental release. Garage Door Opener Emergency Release Cable Overhand Knot Emergency Release Handle Overhand Knot To prevent possible SERIOUS INJURY or DEATH...
... the floor, and avoid contact with a match or lighter to prevent unraveling. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle to prevent slipping. 2. Thread the other end of the ...) 12 Adjust rope length so the handle is within 10 feet (3.05 m) of garage door opener with an overhand knot. Determine where to avoid accidental release. Garage Door Opener Emergency Release Cable Overhand Knot Emergency Release Handle Overhand Knot To prevent possible SERIOUS INJURY or DEATH...
RJO20 Owner s Manual - English
Page 13
...if needed Clean track surface, and attach lock template to 6" (5-15 cm) from the mounting surface. 4. Drill holes as the garage door opener. For right-side installation ONLY, remove the c-clip from closing completely when slack is configured for left -side installation, skip to...6 Position the Cable Tension Monitor (Required) The cable tension monitor detects any slack in the down on the manual release to disengage the door and open . Installation (continued) 5 Install Power Door Lock 1. You may find it useful to pre-drill the holes with a smaller bit before...
...if needed Clean track surface, and attach lock template to 6" (5-15 cm) from the mounting surface. 4. Drill holes as the garage door opener. For right-side installation ONLY, remove the c-clip from closing completely when slack is configured for left -side installation, skip to...6 Position the Cable Tension Monitor (Required) The cable tension monitor detects any slack in the down on the manual release to disengage the door and open . Installation (continued) 5 Install Power Door Lock 1. You may find it useful to pre-drill the holes with a smaller bit before...
RJO20 Owner s Manual - English
Page 14
...Monitor Header Cable Tension Monitor Roller To insert or release wire, push in the hardware bag. 2. Attach the cable tension monitor to garage door opener. Wall Anchor (2) YOU WILL NEED Screw 14-10x2" (2) Drywall Anchor (screw-in cable on opposite side of garage door during door travel . ...drill 3/16 inch pilot holes for screws. NOTE: Cable must be flush with screwdriver tip Cable WHT/ GRN Garage door opener Staples 14 Check there is on the garage door opener. The cable tension monitor MUST be free from the moving parts of the cable. 3. Run wire to ...
...Monitor Header Cable Tension Monitor Roller To insert or release wire, push in the hardware bag. 2. Attach the cable tension monitor to garage door opener. Wall Anchor (2) YOU WILL NEED Screw 14-10x2" (2) Drywall Anchor (screw-in cable on opposite side of garage door during door travel . ...drill 3/16 inch pilot holes for screws. NOTE: Cable must be flush with screwdriver tip Cable WHT/ GRN Garage door opener Staples 14 Check there is on the garage door opener. The cable tension monitor MUST be free from the moving parts of the cable. 3. Run wire to ...
RJO20 Owner s Manual - English
Page 15
... there are connected and properly aligned. YOU WILL NEED Screw 6ABx1-1/4" (Standard installation) (2) Drywall Anchors (2) Screw 6-32x1" (pre-wired) (2) (to garage door opener) Push bar 6 7/16" (11 mm) 1 10 To insert or release wire, push in conjunction with another wired door control connected to your garage door...3 45 (to door control) 9 15 NOTE: DO NOT connect the power and operate the garage door opener at a minimum height of door. The door will travel to the full open position but will not return to red. 11. To prevent possible SERIOUS INJURY or DEATH from ALL moving parts...
... there are connected and properly aligned. YOU WILL NEED Screw 6ABx1-1/4" (Standard installation) (2) Drywall Anchors (2) Screw 6-32x1" (pre-wired) (2) (to garage door opener) Push bar 6 7/16" (11 mm) 1 10 To insert or release wire, push in conjunction with another wired door control connected to your garage door...3 45 (to door control) 9 15 NOTE: DO NOT connect the power and operate the garage door opener at a minimum height of door. The door will travel to the full open position but will not return to red. 11. To prevent possible SERIOUS INJURY or DEATH from ALL moving parts...
RJO20 Owner s Manual - English
Page 16
..., 200 watts total). NOTE: Do not use A19 size bulbs. Housing Program all lights to one opener to prevent intermittent light behavior. To provide an adequate visual alert, the garage door opener light bulb MUST be a minimum of 40 Watt (or equivalent). 3. Wind any excess cord around ... or light socket: • DO NOT use short neck or specialty light bulbs. • DO NOT use drywall anchors provided. Multiple openers in between lights. Clips slide in the same garage Plastic Metal Plate may reduce the range or performance of your remote control(s). Select an appropriate...
..., 200 watts total). NOTE: Do not use A19 size bulbs. Housing Program all lights to one opener to prevent intermittent light behavior. To provide an adequate visual alert, the garage door opener light bulb MUST be a minimum of 40 Watt (or equivalent). 3. Wind any excess cord around ... or light socket: • DO NOT use short neck or specialty light bulbs. • DO NOT use drywall anchors provided. Multiple openers in between lights. Clips slide in the same garage Plastic Metal Plate may reduce the range or performance of your remote control(s). Select an appropriate...
RJO20 Owner s Manual - English
Page 17
...The mounting brackets are available if needed. Be sure power is closing, the door will stop and reverse to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from inside the garage so that the sending and receiving ... floor Facing the door from a closing . If an obstruction breaks the light beam while the door is NOT connected to full open position, and the opener lights will flash 10 times. IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned, the safety reversing sensor will move...
...The mounting brackets are available if needed. Be sure power is closing, the door will stop and reverse to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from inside the garage so that the sending and receiving ... floor Facing the door from a closing . If an obstruction breaks the light beam while the door is NOT connected to full open position, and the opener lights will flash 10 times. IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned, the safety reversing sensor will move...
RJO20 Owner s Manual - English
Page 18
... your door track will not support the bracket securely, see Option C: Floor Installation. Be sure there is enough clearance for the sensor beam to the opener is needed, an extension bracket (Model 041A5281-1) or wood blocks can be used. OPTION C: Floor Installation 1. Slip the curved arms over the rounded edge of...
... your door track will not support the bracket securely, see Option C: Floor Installation. Be sure there is enough clearance for the sensor beam to the opener is needed, an extension bracket (Model 041A5281-1) or wood blocks can be used. OPTION C: Floor Installation 1. Slip the curved arms over the rounded edge of...
RJO20 Owner s Manual - English
Page 19
... the tab with lenses pointing toward each set of insulation from each other across the door. Separate white from both sensors to the garage door opener. Strip 7/16 inch (11 mm) of wires. Twist the white/ black wires together. 3. Finger tighten the wing nuts. Securely affix the wire to insert the...
... the tab with lenses pointing toward each set of insulation from each other across the door. Separate white from both sensors to the garage door opener. Strip 7/16 inch (11 mm) of wires. Twist the white/ black wires together. 3. Finger tighten the wing nuts. Securely affix the wire to insert the...
RJO20 Owner s Manual - English
Page 20
...hole in the back of insulation from electrocution or fire: • Be sure power is required by your garage door opener has a grounding type plug with a third grounding pin. RIGHT WRWORNOGNG WRONG PERPMERAMNAENTENWTIRWIINRGING COCNONNECNTEICOTNION OPTION B: PERMANENT WIRING CONNECTION If permanent...a permanent connection through conduit, cut to proper length and strip insulation. 8. Strip 1/2" (1.3 cm) of the garage door opener (according to establish permanent wiring connection. • Garage door installation and wiring MUST be in compliance with ALL local electrical ...
...hole in the back of insulation from electrocution or fire: • Be sure power is required by your garage door opener has a grounding type plug with a third grounding pin. RIGHT WRWORNOGNG WRONG PERPMERAMNAENTENWTIRWIINRGING COCNONNECNTEICOTNION OPTION B: PERMANENT WIRING CONNECTION If permanent...a permanent connection through conduit, cut to proper length and strip insulation. 8. Strip 1/2" (1.3 cm) of the garage door opener (according to establish permanent wiring connection. • Garage door installation and wiring MUST be in compliance with ALL local electrical ...