..., indirect, incidental, or consequential damages. Affiliate companies handle repairs for US and International customers residing in lieu of all other warranties, expressed or implied, including warranties of shipment unless specified otherwise. Warranty and Assistance The LI200X PYRANOMETER is : CAMPBELL SCIENTIFIC, INC. to determine which have no warranty. products which...
LI200X-L LI-COR Silicon Pyranometer - Page 3

...These page numbers refer to specific sections. 1. General Description 1 1.1 Specifications 1 2. Troubleshooting 10 Appendix A. Programming 5 4.1 Example Programs 6 4.1.1 CR1000 Example Program 6 4.1.2 CR10X Example Program 7 4.2 Total Solar Radiation 9 5. LI200X Pyranometer 2 2-1. Maintenance 9 6. LI200X Table of this document. Installation 2 3. LI200X Schematic 5 A.2-1.
LI200X-L LI-COR Silicon Pyranometer - Page 4

Multipliers Required for Average Flux and Total Flux Density for SI and English Units for Average Flux and Total Flux Density in Sl and English Units 6 4-2. Multipliers Required for a LI200S Pyranometer ...... Wiring for Example Programs 6 A.4-1. A-2 ii Connections to Campbell Scientific Dataloggers 4 4-1. LI200X Table of Contents Tables 3-1.
LI200X-L LI-COR Silicon Pyranometer - Page 5

...by Campbell Scientific dataloggers. During the night the LI200X may be measured directly by RF noise. B. Appl. Thurtell, and C. Meteor., 6, 688-694. 1.1 Specifications ...LI200X Pyranometer 1. General Description The LI200X measures incoming solar radiation with acrylic diffuser and stainless steel hardware 0.94" dia x 1.00" H (2.38 cm dia x 2.54 cm H) 1 oz. (28 g) Absolute error...
LI200X-L LI-COR Silicon Pyranometer - Page 6

and will support combustion in the Northern Hemisphere point the cable towards the nearest magnetic pole, e.g. Local fire codes may preclude its resistance to temperature extremes, moisture, and UV degradation. Installation The LI200X should be mounted with the cable pointed towards the North Pole. The LI200X and base/leveling fixture are attached to a tripod or tower...
LI200X-L LI-COR Silicon Pyranometer - Page 7

LI200X Pyranometer NOTE Remove the red cap after installing the sensor. CM225 Pyranometer Mounting Stand and CM202 Crossarm FIGURE 2-2. 015 Pyranometer Mounting Arm 3 Save this cap for shipping or storing the sensor. LI200X Pyranometer LI2003S CM225 Stand CM200 Series Crossarm FIGURE 2-1.
LI200X-L LI-COR Silicon Pyranometer - Page 8

... Scientific Dataloggers Color Red Black White Clear Description Signal Signal Reference Signal Ground Shield CR9000(X) CR5000 CR3000 CR1000 CR800 CR850 Differential High Differential Low CR510 CR500 CR10(X) Differential High Differential Low AG G 21X CR7 CR23X Differential High Differential Low 4 Connections to Campbell Scientific dataloggers are given in Figure 3-1. LI200X Pyranometer...
LI200X-L LI-COR Silicon Pyranometer - Page 9

...LoggerNet datalogger support software....LI200X Pyranometer RED H 40.2 to measure the LI200X can be...LI200X Schematic NOTE If a 21X is measured by the 12 VDC sensor may cause a difference in ground potential between the 21X ground terminals and the reference ground point in Edlog). This offset can be created using the differential voltage instruction (VoltDiff in CRBasic or Instruction...
LI200X-L LI-COR Silicon Pyranometer - Page 10

... given in Table 4-2. Multipliers Required for the examples is found. TABLE 4-2. LI200X Pyranometer TABLE 4-1. Negative values are added to the running total. 'CR1000 'Declare Variables and Units Public SlrW Public SlrMJ Units SlrW=W/m² Units SlrMJ=MJ/m² 6 Negative values are set to Wm-2 and MJm-2. Wiring for Average Flux and Total Flux...
LI200X-L LI-COR Silicon Pyranometer - Page 11

LI200X Pyranometer 'Define Data Tables DataTable(Table1,True,-1) DataInterval(0,60,Min,10) Average(1,SlrW,FP2,False) EndTable DataTable(Table2,True,-1) DataInterval(0,1440,Min,10) Totalize(1,SlrMJ,IEEE4,False) EndTable 'Main Program BeginProg Scan(10,Sec,1,0) 'measure the LI200X VoltDiff(SlrW,1,mV7_5,1,True,0,_60Hz,1,0) 'use 20mV range for 'CR5000 and CR3000 'set negative values to zero If SlrW
LI200X-L LI-COR Silicon Pyranometer - Page 12

... --) into a 2: 1440 Interval (same units as above) 3: 10 Set Output Flag High (Flag 0) 12: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 102 Array ID 8 set negative values to zero 2: If (XF) (P89) 1: 3 X Loc [ SlrW ] 2: 4 < 3: 0 F 4: 30 Then Do 3: Z=F x 10^n (P30) 1: 0 F 2: 0 n, Exponent of 10 3: 3 Z Loc [ SlrW ] 4: End (P95) ; LI200X Pyranometer ;
LI200X-L LI-COR Silicon Pyranometer - Page 13

...4 Loc [ SlrMJ ] 16: Resolution (P78) 1: 0 Low Resolution LI200X Pyranometer 4.2 Total Solar Radiation If the solar radiation is totalized in units of kJ... this limitation for Edlog dataloggers, record an average flux (see Datalogger manuals for Edlog dataloggers is free of debris. 9 Maintenance On a monthly...using the high resolution format (Instruction 78, see Example 2). ...
LI200X-L LI-COR Silicon Pyranometer - Page 14

... by the measurement instruction. 2. No voltage indicates a problem with a calibration of 92 μA kW-1 m2, will have the resistor set to scratch the surface of the sensor head is clean, and that the Range code is properly leveled. 2. for the datalogger type. 3. Troubleshooting Symptom: -9999 or radiation values around 0 1. For example, a pyranometer with the photodiode...
LI200X-L LI-COR Silicon Pyranometer - Page 15

...one pyranometer to the corresponding low side (L). A.2.1 Wiring Signal positive is done by Campbell Scientific dataloggers. A.1.1 Wiring The red lead is then made with Instruction 2.... Unmodified Pyranometer Wiring Schematic A-1 FIGURE A.2-1. The input range and multipliers vary from one pyranometer to the corresponding low side (L). The clear lead is installed between the ...
LI200X-L LI-COR Silicon Pyranometer - Page 16

... or on the wiring panel. In this case the 25 mV slow range for the CR10 and 15 mV slow range for a LI200S Pyranometer UNITS W m-2 MJ m-2 kJ m-2 cal cm-2 min-1 cal cm-2 MULTIPLIER (1/C) * 1000 t * (1/C) * 0.001 t *...the millivolt reading to 8.7 mV kW-1 m2. This is 1 kW m-2. LI200S Pyranometer A.3 Input Range The following is obtained by multiplying the calibration by LI-COR, ...

Campbell Scientific LI200X Reviews

Do you have an experience with the Campbell Scientific LI200X that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific LI200X Search Terms

The following terms are frequently used to search for Campbell Scientific LI200X support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific LI200X.
Manuals / Documents
Download any of our Campbell Scientific LI200X manuals for free!

We have the following 1 documents available for the Campbell Scientific LI200X:
  • LI200X-L LI-COR Silicon Pyranometer
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific LI200X manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific LI200X user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.