Campbell Scientific HMP60 Support and Manuals

Get Help and Manuals for this Campbell Scientific item

View All Support Options Below
Free Campbell Scientific HMP60 manuals!
Problems with Campbell Scientific HMP60?

Ask a Question

Popular Campbell Scientific HMP60 Manual Pages

HMP60 Temperature and Relative Humidity Probe - Page 3

.... The warranty for any products which shall be free from defects in the corresponding Campbell pricelist or product manual. Campbell's obligation under this warranty is not liable for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by surface carrier prepaid within the continental United States...
HMP60 Temperature and Relative Humidity Probe - Page 4

... to repair@campbellsci.com or faxed to refuse service on the outside of Product Cleanliness and Decontamination" form and comply with the requirements specified in countries served by Campbell Scientific, Inc...of the problem, an RMA number will be issued. The following contact information is incomplete, the product will be returned to determine which Campbell Scientific company serves ...
HMP60 Temperature and Relative Humidity Probe - Page 7

... the packaging and contents for its use inside buildings. Although the HMP60 is shipped with a Campbell Scientific applications engineer. and will support combustion in the remaining sections. 2. Remember to remove the yellow cap prior to ensure the correct product and cable length are received. The model number and cable length are available in air. The...
HMP60 Temperature and Relative Humidity Probe - Page 11

Select a datalogger and scan interval. 5 HMP60 Temperature and Relative Humidity Probe 4.2 Step 2 - Open Short Cut and click on New Program. 2. Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram The simplest method for programming the datalogger to measure the HMP60 is to use Campbell Scientific's SCWin Short Cut Program Generator. 1.
HMP60 Temperature and Relative Humidity Probe - Page 12

... units of the public variables. Units default to AirTC and RH that hold the air temperature and relative humidity measurements. Variables default to Deg C. 6 Select HMP50/HMP60 Temperature and Relative Humidity Sensor then click the right arrow to add it to the list of sensors to be measured...
HMP60 Temperature and Relative Humidity Probe - Page 13

... (PRT) and a Vaisala INTERCAP® capacitive relative humidity sensor. Table 5-1 gives the recommended cable length. Cable length is specified when the sensor is user specified. HMP60 Temperature and Relative Humidity Probe 5. The -L option on the model HMP60 Temperature and Relative Humidity probe (HMP60-L) indicates that the cable length is ordered. This manual refers to the...
HMP60 Temperature and Relative Humidity Probe - Page 14

...Refer to www.campbellsci.com/cws900 for more information. • 6. Specifications Features Field -replaceable humidity chip eliminates recalibration down time Compatible with all Campbell Scientific dataloggers (including the CR200(X) series) Compatible with the CWS900-series ...enclosure on the leg base of a light-weight tripod. HMP60 Temperature and Relative Humidity Probe TABLE 5-1.
HMP60 Temperature and Relative Humidity Probe - Page 15

...® rubber. and will support combustion in ) AISI 316 ... burning when tested according to temperature extremes, moisture, and UV degradation. HMP60 Temperature and Relative Humidity Probe Probe Body Diameter: Filter: Filter Diameter: ...956;m Teflon membrane 1.2 cm (0.47 in air. Local fire codes may preclude its resistance to U.L. 94 H.B. However, this jacket will pass FMVSS302. This ...
HMP60 Temperature and Relative Humidity Probe - Page 16

... 41003-5 10-plate shield. Sensors should be used . Installation 7.1 Siting Sensors should be mounted in . Standard measurement heights: 1.5 m (AASC) 1.25 - 2.0 m (WMO) 2.0 m (EPA) See Section 10 for a list of the 41003-5; The HMP60 is used to a crossarm, mast, or usersupplied pipe with a 1.0-in the lower part of any nearby obstruction, and at least 9 m (EPA...
HMP60 Temperature and Relative Humidity Probe - Page 17

... temperature and one for users who write their own datalogger programs. A datalogger program to measure this section to Campbell Scientific dataloggers are given in Table 7-1. HMP60 wiring TABLE 7-1. The probe is for relative humidity. HMP60 Temperature and Relative Humidity Probe Black White Blue Brown Clear Temperature Signal Relative Humidity Signal Signal & Power Reference Power...
HMP60 Temperature and Relative Humidity Probe - Page 18

... Relative Humidity Probe The temperature and relative humidity signals from the HMP60 are measured using two single-ended analog measurements (VoltSE() in CRBasic or Instruction 1 in Edlog). Calibration for CR1000 'CR1000 'Created by SCWIN (2.1) Public AirTC Public RH DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Average(1,AirTC,FP2,0) Sample(1,RH,FP2) ...
HMP60 Temperature and Relative Humidity Probe - Page 19

... 2: 0 3: 3 05: End (P95) F Exponent of 10 Z Loc [ RH_pct ] 7.5 Long Lead Lengths Long lead lengths cause errors in temperature and relative humidity is 0.52°C and 0.52% per 100 feet of the HMP60 with Campbell Scientific's dataloggers. The approximate error in the measured temperature and relative humidity. Understanding the following details are measured, both the signal...
HMP60 Temperature and Relative Humidity Probe - Page 20

...energy available to 36.9%. Conversely, a decrease in air temperature causes a corresponding decrease in the HMP60 (P/N 18159) has resistance of 1.17 kPa, the saturation vapor pressure is 2.34 kPa and... and air temperature and saturation vapor pressure are connected to saturation, has decreased. HMP60 Temperature and Relative Humidity Probe reference and power ground are given by Goff and ...
HMP60 Temperature and Relative Humidity Probe - Page 21

... and RH: VoltSE(AirTC,1,mV2500,1,0,0,_60Hz,0.1,-40.0) VoltSE(RH,1,mV2500,2,0,0,_60Hz,0.1,0) If (RH>100) And (RH The relative humidity measurement must be stored. TABLE 7-5. HMP60 Temperature and Relative Humidity Probe VaporPressure() instruction to calculate vapor pressure from temperature and relative humidity measurements (see Section 7.6.2). Edlog dataloggers must be in percent of the...
HMP60 Temperature and Relative Humidity Probe - Page 24

...-103. Soc. J. Soc., 73, No. 4, 449-457. Soc. Hold the sides of the manuals also include siting information for the datalogger type. Ag. Eng., 51, 125-164. Guide to the correct analog input channels as specified by the measurement instructions. Rinse the RH chip or dispose of Observation. Check that the sensor is...

Campbell Scientific HMP60 Reviews

Do you have an experience with the Campbell Scientific HMP60 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific HMP60 Search Terms

The following terms are frequently used to search for Campbell Scientific HMP60 support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific HMP60.
Manuals / Documents
Download any of our Campbell Scientific HMP60 manuals for free!

We have the following 1 documents available for the Campbell Scientific HMP60:
  • HMP60 Temperature and Relative Humidity Probe
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific HMP60 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific HMP60 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.