107-L Temperature Probe
Page 6
..., Resistance, and Temperature C-1 ii Wire Color, Function, and Datalogger Connection 6 8-1. 107 Measurement Details 11 8-2. Resistance or Voltage Ratio to Temperature ....... Linearization error, where error is the difference between actual and datalogger computed temperature 5 107 and 41303-5A Radiation Shield on a tripod mast 8 107 and 41303-5A Radiation Shield on a CM200 Series Crossarm.... 9 107 thermistor probe schematic 10 Tables...
..., Resistance, and Temperature C-1 ii Wire Color, Function, and Datalogger Connection 6 8-1. 107 Measurement Details 11 8-2. Resistance or Voltage Ratio to Temperature ....... Linearization error, where error is the difference between actual and datalogger computed temperature 5 107 and 41303-5A Radiation Shield on a tripod mast 8 107 and 41303-5A Radiation Shield on a CM200 Series Crossarm.... 9 107 thermistor probe schematic 10 Tables...
107-L Temperature Probe
Page 7
... www.campbellsci.com, the ResourceDVD, or find it in air. However, local fire codes may preclude its resistance to measure the 107 probe and assign datalogger wiring terminals. Model numbers are received. Report any shortages immediately to get started. 1. It is an easy way..., moisture, and UV degradation. Quickstart Short Cut is rated as slow burning when tested according to measure temperature in air, soil, and water. Use the following procedure to Campbell Scientific. 4. It is usually found on the install file icon. It is used because of LoggerNet, PC200W, PC400...
... www.campbellsci.com, the ResourceDVD, or find it in air. However, local fire codes may preclude its resistance to measure the 107 probe and assign datalogger wiring terminals. Model numbers are received. Report any shortages immediately to get started. 1. It is an easy way..., moisture, and UV degradation. Quickstart Short Cut is rated as slow burning when tested according to measure temperature in air, soil, and water. Use the following procedure to Campbell Scientific. 4. It is usually found on the install file icon. It is used because of LoggerNet, PC200W, PC400...
107-L Temperature Probe
Page 8
Model 107 Temperature Probe 2. When Short Cut opens, select New Program. 4. To open Short Cut, click on the desktop of 5 seconds is OK for most applications). Select Datalogger Model and Scan Interval (default of your computer. The Short Cut installation should place a shortcut icon on this icon. 3. Click Next. 2
Model 107 Temperature Probe 2. When Short Cut opens, select New Program. 4. To open Short Cut, click on the desktop of 5 seconds is OK for most applications). Select Datalogger Model and Scan Interval (default of your computer. The Short Cut installation should place a shortcut icon on this icon. 3. Click Next. 2
107-L Temperature Probe
Page 9
... be printed out now or after more sensors are added. 7. Under the Available Sensors and Devices list, select the Sensors | Temperature folder. Click to move the selection to degree Celsius. Model 107 Temperature Probe 5. The wiring diagram can be changed by clicking on Wiring Diagram to see how the sensor is accessed by clicking...
... be printed out now or after more sensors are added. 7. Under the Available Sensors and Devices list, select the Sensors | Temperature folder. Click to move the selection to degree Celsius. Model 107 Temperature Probe 5. The wiring diagram can be changed by clicking on Wiring Diagram to see how the sensor is accessed by clicking...
107-L Temperature Probe
Page 10
... in an epoxy-filled aluminum housing. Also compatible with Campbell Scientific CRBasic dataloggers CR800 series, CR1000, CR3000, and CR5000. Specifications Features • Measures air, soil, or water temperature • Compatible with AM16/32-series multiplexers • Easy to 15 m (50 ft) or 21 psi. Model 107 Temperature Probe 8. See Specifications for a complete list of a thermistor encapsulated...
... in an epoxy-filled aluminum housing. Also compatible with Campbell Scientific CRBasic dataloggers CR800 series, CR1000, CR3000, and CR5000. Specifications Features • Measures air, soil, or water temperature • Compatible with AM16/32-series multiplexers • Easy to 15 m (50 ft) or 21 psi. Model 107 Temperature Probe 8. See Specifications for a complete list of a thermistor encapsulated...
107-L Temperature Probe
Page 11
Model 107 Temperature Probe Edlog Temp (107) (P11) Polynomial Linearization Error:
Model 107 Temperature Probe Edlog Temp (107) (P11) Polynomial Linearization Error:
107-L Temperature Probe
Page 12
.... If your data acquisition needs are more complex, the files that Short Cut creates are provided in CRBasic Editor. Model 107 Temperature Probe 7.1 Wiring to be found in Section 8.3, Electrically Noisy Environments, and Section 8.4, Long Cable Lengths. Complete program examples for...cable lengths or in electrically noisy environments, consider employing the measurement programming techniques outlined in Appendix B, Example Programs. If the 107 probe is the best source for CRBasic and Edlog dataloggers are imported and edited in Section 8.2, Measurement and Output Linearization. 6...
.... If your data acquisition needs are more complex, the files that Short Cut creates are provided in CRBasic Editor. Model 107 Temperature Probe 7.1 Wiring to be found in Section 8.3, Electrically Noisy Environments, and Section 8.4, Long Cable Lengths. Complete program examples for...cable lengths or in electrically noisy environments, consider employing the measurement programming techniques outlined in Appendix B, Example Programs. If the 107 probe is the best source for CRBasic and Edlog dataloggers are imported and edited in Section 8.2, Measurement and Output Linearization. 6...
107-L Temperature Probe
Page 13
... be located at a distance of at least four times the height of any nearby obstruction, and at least 9 m (EPA) in diameter. Model 107 Temperature Probe 7.2.1 CRBasic 7.2.2 Edlog The Therm107() measurement instruction programs CRBasic dataloggers (CR800-series, CR1000, CR3000, CR5000) to 32 • Ac mains noise filtering - set Integ to 32 ...
... be located at a distance of at least four times the height of any nearby obstruction, and at least 9 m (EPA) in diameter. Model 107 Temperature Probe 7.2.1 CRBasic 7.2.2 Edlog The Therm107() measurement instruction programs CRBasic dataloggers (CR800-series, CR1000, CR3000, CR5000) to 32 • Ac mains noise filtering - set Integ to 32 ...
107-L Temperature Probe
Page 14
... provided with a 5.1 cm (2.4 inch) outer diameter. The 41303-5B attaches to 2.1 inch) outer diameter. Model 107 Temperature Probe Standard air temperature measurement heights: • 1.25 to 2.0 m (WMO) • 2.0 m (EPA) • 2.0 m and 10.0 m temperature difference (EPA) When exposed to sunlight, the 107 should be housed in a 41303-5A or 413035B six-plate solar radiation shield. The white...
... provided with a 5.1 cm (2.4 inch) outer diameter. The 41303-5B attaches to 2.1 inch) outer diameter. Model 107 Temperature Probe Standard air temperature measurement heights: • 1.25 to 2.0 m (WMO) • 2.0 m (EPA) • 2.0 m and 10.0 m temperature difference (EPA) When exposed to sunlight, the 107 should be housed in a 41303-5A or 413035B six-plate solar radiation shield. The white...
107-L Temperature Probe
Page 15
...as a piling. 7.5 Soil Temperature Installation The 107 tends to measure the average temperature over its length, so it should also be necessary for long cable runs, especially in locations subject to 15 m (50 ft) or 21 psi. 41303-5A 107 Model 107 Temperature Probe Tripod Mast or Tower Leg ...CM200 Series Crossarm FIGURE 7-2. 107 and 41303-5A Radiation Shield on a CM200 Series Crossarm The 107 is held within the radiation shield by the maximum water pressure allowed ...
...as a piling. 7.5 Soil Temperature Installation The 107 tends to measure the average temperature over its length, so it should also be necessary for long cable runs, especially in locations subject to 15 m (50 ft) or 21 psi. 41303-5A 107 Model 107 Temperature Probe Tripod Mast or Tower Leg ...CM200 Series Crossarm FIGURE 7-2. 107 and 41303-5A Radiation Shield on a CM200 Series Crossarm The 107 is held within the radiation shield by the maximum water pressure allowed ...
107-L Temperature Probe
Page 16
Model 107 Temperature Probe 8. With reference to temperature. Operation 8.1 Sensor Schematic FIGURE 8-1. 107 thermistor probe schematic 8.2 Measurement and Output Linearization Campbell Scientific dataloggers measure the 107 probe thermistor and convert the result to the previous FIGURE 8-1, 107 thermistor probe schematic, a precise excitation voltage is applied at the Vx line and the voltage drop across the 1 kΩ resistor is related to thermistor resistance (Rs...
Model 107 Temperature Probe 8. With reference to temperature. Operation 8.1 Sensor Schematic FIGURE 8-1. 107 thermistor probe schematic 8.2 Measurement and Output Linearization Campbell Scientific dataloggers measure the 107 probe thermistor and convert the result to the previous FIGURE 8-1, 107 thermistor probe schematic, a precise excitation voltage is applied at the Vx line and the voltage drop across the 1 kΩ resistor is related to thermistor resistance (Rs...
107-L Temperature Probe
Page 17
... (automatically applied) † Fixed series resistance is subtracted before applying Steinhart-Hart. ‡ Multiplier of 800 scales Vs/Vx for the polynomial fit. TABLE 8-2. Model 107 Temperature Probe TABLE 8-1. 107 Measurement Details Datalogger Model CR800 CR1000 CR3000 CR5000 Measurement Instruction CRBasic Therm107() Excite mV Result Scaling Equation Applied to...
... (automatically applied) † Fixed series resistance is subtracted before applying Steinhart-Hart. ‡ Multiplier of 800 scales Vs/Vx for the polynomial fit. TABLE 8-2. Model 107 Temperature Probe TABLE 8-1. 107 Measurement Details Datalogger Model CR800 CR1000 CR3000 CR5000 Measurement Instruction CRBasic Therm107() Excite mV Result Scaling Equation Applied to...
107-L Temperature Probe
Page 18
... Polynomial (P55). The following code examples filter 60 Hz noise. The key parameters are increased by adding a measurement delay to temperature using these dataloggers in electrically noisy environments, use of measurement error. 60 Hz noise is common in the United States. 50 Hz...slow range ;21X,CR7: 4000 mV 8.4 Long Cable Lengths Long cable lengths may require longer than normal analog measurement settling times. Model 107 Temperature Probe 8.3 Electrically Noisy Environments EMF noise emanating from the ac mains power grid can usually be a significant source of the P5 and P55 ...
... Polynomial (P55). The following code examples filter 60 Hz noise. The key parameters are increased by adding a measurement delay to temperature using these dataloggers in electrically noisy environments, use of measurement error. 60 Hz noise is common in the United States. 50 Hz...slow range ;21X,CR7: 4000 mV 8.4 Long Cable Lengths Long cable lengths may require longer than normal analog measurement settling times. Model 107 Temperature Probe 8.3 Electrically Noisy Environments EMF noise emanating from the ac mains power grid can usually be a significant source of the P5 and P55 ...
107-L Temperature Probe
Page 19
... of Hazardous Material and Decontamination" form. When using the CR10, 21X, and CR7 dataloggers, if the 107 probe has cable lengths of more information. 9.1 Troubleshooting Symptom: Temperature is connected to accommodate long cable lengths. longer settling times can be entered into the Settling Time parameter....CR7 dataloggers have no programming provision for compensating for the CR10X, CR510, and CR23X include a delay to datalogger ground. 13 Model 107 Temperature Probe CRBasic For CRBasic dataloggers, the 60 Hz and 50 Hz integration options include a 3 ms settling time;
... of Hazardous Material and Decontamination" form. When using the CR10, 21X, and CR7 dataloggers, if the 107 probe has cable lengths of more information. 9.1 Troubleshooting Symptom: Temperature is connected to accommodate long cable lengths. longer settling times can be entered into the Settling Time parameter....CR7 dataloggers have no programming provision for compensating for the CR10X, CR510, and CR23X include a delay to datalogger ground. 13 Model 107 Temperature Probe CRBasic For CRBasic dataloggers, the 60 Hz and 50 Hz integration options include a 3 ms settling time;
107-L Temperature Probe
Page 20
... reported as specified by the polynomial, not the actual calibration temperature. For example, a 107 probe placed in Section 8.3, Electrically Noisy Environments, and Section 8.4, Long Cable Lengths. Model 107 Temperature Probe Symptom: Temperature is reported. Check the cable for signs of the 107 probe is connected to datalogger ground, and the datalogger is a registered trademark of the offset must be...
... reported as specified by the polynomial, not the actual calibration temperature. For example, a 107 probe placed in Section 8.3, Electrically Noisy Environments, and Section 8.4, Long Cable Lengths. Model 107 Temperature Probe Symptom: Temperature is reported. Check the cable for signs of the 107 probe is connected to datalogger ground, and the datalogger is a registered trademark of the offset must be...
107-L Temperature Probe
Page 23
...used directly with CR800 series, CR1000, CR3000, and CR5000 dataloggers. 'Program measures one 107 temperature probe once a second and 'stores the average temperature every 60 minutes. 'Wiring Diagram '107 Probe ' ' Wire ' Color Function ' ----- -------- ' Black Voltage-excitation input '...with any datalogger program. Contact a Campbell Scientific application engineer for 60 minute averages: DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Average(1,T107_C,IEEE4,0) EndTable BeginProg Scan(1,Sec,1,0) 'Measure the temperature Therm107(T107_C,1,1,Vx1,0,_60Hz,1.0,0.0) 'Call ...
...used directly with CR800 series, CR1000, CR3000, and CR5000 dataloggers. 'Program measures one 107 temperature probe once a second and 'stores the average temperature every 60 minutes. 'Wiring Diagram '107 Probe ' ' Wire ' Color Function ' ----- -------- ' Black Voltage-excitation input '...with any datalogger program. Contact a Campbell Scientific application engineer for 60 minute averages: DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Average(1,T107_C,IEEE4,0) EndTable BeginProg Scan(1,Sec,1,0) 'Measure the temperature Therm107(T107_C,1,1,Vx1,0,_60Hz,1.0,0.0) 'Call ...
107-L Temperature Probe
Page 24
Appendix B. Example Programs ;{CR10X} ;Program measures one 107 temperature probe once a second ;and stores the average temperature every 60 minutes. ;Wiring Diagram ;107 Probe ; ; Color Function ; ----- -------- ; Red Analog-voltage output ; Wire ; Clear Shield CR10X -----E1 SE1 AG G *Table 1 Program 01: 1.0000 Execution Interval (seconds) 1: Temp (107) (P11) 1: 1 Reps 2: 1 SE Channel 3: 21 Excite all reps w/E1, 60Hz, 10ms delay...
Appendix B. Example Programs ;{CR10X} ;Program measures one 107 temperature probe once a second ;and stores the average temperature every 60 minutes. ;Wiring Diagram ;107 Probe ; ; Color Function ; ----- -------- ; Red Analog-voltage output ; Wire ; Clear Shield CR10X -----E1 SE1 AG G *Table 1 Program 01: 1.0000 Execution Interval (seconds) 1: Temp (107) (P11) 1: 1 Reps 2: 1 SE Channel 3: 21 Excite all reps w/E1, 60Hz, 10ms delay...