107-L Temperature Probe
Page 7
...any shortages immediately to get started. 1. However, local fire codes may preclude its resistance to U.L. 94 H.B. Use the following procedure to Campbell Scientific. 4. Model 107 Temperature Probe 1. See Section 6, Specifications, for a complete list of LoggerNet, PC200W, PC400, or RTDAQ software. 1 On cables and ...Cut by clicking on each product. It is used because of the 107 cable, will support combustion in air, soil, and water. It is compatible with the carrier. Contact Campbell Scientific to facilitate repair or replacement. • Check model information against the ...
...any shortages immediately to get started. 1. However, local fire codes may preclude its resistance to U.L. 94 H.B. Use the following procedure to Campbell Scientific. 4. Model 107 Temperature Probe 1. See Section 6, Specifications, for a complete list of LoggerNet, PC200W, PC400, or RTDAQ software. 1 On cables and ...Cut by clicking on each product. It is used because of the 107 cable, will support combustion in air, soil, and water. It is compatible with the carrier. Contact Campbell Scientific to facilitate repair or replacement. • Check model information against the ...
107-L Temperature Probe
Page 10
...make sure it is a rugged probe that accurately measures air, soil, or water temperature in water to 50 °C) 4 Overview The 107 is making reasonable measurements. 5. When measuring air temperature, a 41303-5A radiation shield is active, you can click Finish in Short Cut ... design allows the probe to be prompted to send the program just created to mount the 107 and limit solar radiation loading. The sensor consists of compatible dataloggers. 6. Also compatible with Campbell Scientific CRBasic dataloggers CR800 series, CR1000, CR3000, and CR5000. If LoggerNet, PC400, RTDAQ, or...
...make sure it is a rugged probe that accurately measures air, soil, or water temperature in water to 50 °C) 4 Overview The 107 is making reasonable measurements. 5. When measuring air temperature, a 41303-5A radiation shield is active, you can click Finish in Short Cut ... design allows the probe to be prompted to send the program just created to mount the 107 and limit solar radiation loading. The sensor consists of compatible dataloggers. 6. Also compatible with Campbell Scientific CRBasic dataloggers CR800 series, CR1000, CR3000, and CR5000. If LoggerNet, PC400, RTDAQ, or...
107-L Temperature Probe
Page 16
With reference to temperature by Campbell Scientific dataloggers. 10 The ratio of measured voltage (Vs) to excitation voltage (Vx) is related to thermistor resistance (Rs), and the 1 kΩ ohm and 249 k..., a precise excitation voltage is applied at the Vx line and the voltage drop across the 1 kΩ resistor is measured at the Vs line. Model 107 Temperature Probe 8. Operation 8.1 Sensor Schematic FIGURE 8-1. 107 thermistor probe schematic 8.2 Measurement and Output Linearization Campbell Scientific dataloggers measure the 107 probe thermistor and convert the result to temperature.
With reference to temperature by Campbell Scientific dataloggers. 10 The ratio of measured voltage (Vs) to excitation voltage (Vx) is related to thermistor resistance (Rs), and the 1 kΩ ohm and 249 k..., a precise excitation voltage is applied at the Vx line and the voltage drop across the 1 kΩ resistor is measured at the Vs line. Model 107 Temperature Probe 8. Operation 8.1 Sensor Schematic FIGURE 8-1. 107 thermistor probe schematic 8.2 Measurement and Output Linearization Campbell Scientific dataloggers measure the 107 probe thermistor and convert the result to temperature.
107-L Temperature Probe
Page 23
Contact a Campbell Scientific application engineer for 60 minute averages: DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Average(1,T107_C,IEEE4,0) EndTable BeginProg Scan(1,Sec,1,0) 'Measure the ... Program This example can be used directly with CR800 series, CR1000, CR3000, and CR5000 dataloggers. 'Program measures one 107 temperature probe once a second and 'stores the average temperature every 60 minutes. 'Wiring Diagram '107 Probe ' ' Wire ' Color Function ' ----- -------- ' Black Voltage-excitation input ' Red Analog-voltage output ' Purple Bridge-resistor...
Contact a Campbell Scientific application engineer for 60 minute averages: DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Average(1,T107_C,IEEE4,0) EndTable BeginProg Scan(1,Sec,1,0) 'Measure the ... Program This example can be used directly with CR800 series, CR1000, CR3000, and CR5000 dataloggers. 'Program measures one 107 temperature probe once a second and 'stores the average temperature every 60 minutes. 'Wiring Diagram '107 Probe ' ' Wire ' Color Function ' ----- -------- ' Black Voltage-excitation input ' Red Analog-voltage output ' Purple Bridge-resistor...