Page 12
...Internal c o n n e c t o r s 1 x Floppy disk drive connector 1 x IDE connector 6 x Serial ATA connectors 2 x Mini-SAS connectors support a total of 8 devices (KFN32-D SLI/SAS model only) 2 x CPU fan connectors 1 x SMBus header for back-plane 2 x Front fan connectors 2 x Rear fan connectors 1 x 24-pin ATX... power connector 1 x 8-pin ATX 12 V power connector 1 x 4-pin ASUS EZ Plug™ connector 3 x USB 2.0 connectors ...
...Internal c o n n e c t o r s 1 x Floppy disk drive connector 1 x IDE connector 6 x Serial ATA connectors 2 x Mini-SAS connectors support a total of 8 devices (KFN32-D SLI/SAS model only) 2 x CPU fan connectors 1 x SMBus header for back-plane 2 x Front fan connectors 2 x Rear fan connectors 1 x 24-pin ATX... power connector 1 x 8-pin ATX 12 V power connector 1 x 4-pin ASUS EZ Plug™ connector 3 x USB 2.0 connectors ...
User Guide
Page 15
... SATA power cable 3-in-1 Floppy/ Ultra ATA disk drive cable SAS cable I/O shield CPU retention module Screws Support CD User guide Packing Quantity Motherboard KFN32-D SLI 3 3 (dual-plug) 1 1 1 2 1 1 1 piece per box KFN32-D SLI/SAS 3 3 (dual-plug) 1 1 1 1 2 1 1 1 piece per box MB Bulk Pack - 1 1 2 1 1 10 pieces per carton ASUS KFN32-D SLI Series 1- The motherboard delivers a host of new features and latest...
... SATA power cable 3-in-1 Floppy/ Ultra ATA disk drive cable SAS cable I/O shield CPU retention module Screws Support CD User guide Packing Quantity Motherboard KFN32-D SLI 3 3 (dual-plug) 1 1 1 2 1 1 1 piece per box KFN32-D SLI/SAS 3 3 (dual-plug) 1 1 1 1 2 1 1 1 piece per box MB Bulk Pack - 1 1 2 1 1 10 pieces per carton ASUS KFN32-D SLI Series 1- The motherboard delivers a host of new features and latest...
User Guide
Page 17
ASUS KFN32-D SLI Series 1- The NVIDIA® MCP55 Professional allows RAID 0, RAID 1, RAID 0+1, RAID 5 and JBOD configuration for critical components. It also provides Jack-Sensing function, S/PDIF out ... bandwidth on USB 2.0. Temperature, fan, and voltage monitoring The CPU temperature is monitored for timely failure detection. USB 2.0 is backward compatible with USB 1.1. The LSI1068 SAS RAID controller supports 8-Port Serial Attached SCSI/ SATA ports and allows JBOD, RAID 0, RAID 1, and RAID 1E configurations. 8-channel high definition audio The motherboard supports...
ASUS KFN32-D SLI Series 1- The NVIDIA® MCP55 Professional allows RAID 0, RAID 1, RAID 0+1, RAID 5 and JBOD configuration for critical components. It also provides Jack-Sensing function, S/PDIF out ... bandwidth on USB 2.0. Temperature, fan, and voltage monitoring The CPU temperature is monitored for timely failure detection. USB 2.0 is backward compatible with USB 1.1. The LSI1068 SAS RAID controller supports 8-Port Serial Attached SCSI/ SATA ports and allows JBOD, RAID 0, RAID 1, and RAID 1E configurations. 8-channel high definition audio The motherboard supports...
User Guide
Page 105
... any advantage over using separate disks independently and does not provide fault tolerance or other drive. LSI SAS 1068 PCI-X eight-port, 3.0 Gbit/s SAS/SATA controller supports eight additional SAS/SATA hard drives that allows you install an operating system to the selected hard disk drive. Two ... allows you get all applications to the surviving drive as it contains a complete copy of the data in the other RAID performance benefits. ASUS KFN32-D SLI Series 5- Use two new drives or use an existing drive and three new drives for this setup. 5.1 Setting up RAID The NVIDIA...
... any advantage over using separate disks independently and does not provide fault tolerance or other drive. LSI SAS 1068 PCI-X eight-port, 3.0 Gbit/s SAS/SATA controller supports eight additional SAS/SATA hard drives that allows you install an operating system to the selected hard disk drive. Two ... allows you get all applications to the surviving drive as it contains a complete copy of the data in the other RAID performance benefits. ASUS KFN32-D SLI Series 5- Use two new drives or use an existing drive and three new drives for this setup. 5.1 Setting up RAID The NVIDIA...
User Guide
Page 106
... IDE and/or SATA connectors supported by the NVIDIA® MCP55 Professional chip. 5.1.2 Installing hard disk drives The motherboard supports Serial ATA (all models) and SAS hard disk drives (KFN32-D SLI/SAS model only) for RAID configuration: 1.
... IDE and/or SATA connectors supported by the NVIDIA® MCP55 Professional chip. 5.1.2 Installing hard disk drives The motherboard supports Serial ATA (all models) and SAS hard disk drives (KFN32-D SLI/SAS model only) for RAID configuration: 1.
User Guide
Page 115
... disk drives. 2. During POST, press to start LSI Logic Configuration Utility... ASUS KFN32-D SLI Series 5-11 Integrated Mirroring Enhanced (IME) supports three to create the following RAID set(s) from SAS hard disk drives supported by the LSI1068 PCI-X SAS controller: • RAID 1 (Integrated Mirroring) • RAID 1E (Integrated Mirroring Enhanced) • RAID 0 (Integrated Stripping) 5.3.1 Integrated...
... disk drives. 2. During POST, press to start LSI Logic Configuration Utility... ASUS KFN32-D SLI Series 5-11 Integrated Mirroring Enhanced (IME) supports three to create the following RAID set(s) from SAS hard disk drives supported by the LSI1068 PCI-X SAS controller: • RAID 1 (Integrated Mirroring) • RAID 1E (Integrated Mirroring Enhanced) • RAID 0 (Integrated Stripping) 5.3.1 Integrated...
User Guide
Page 116
... Array Type -- SAS1068 v6.05.06.00 (2006.01.16) Adapter PCI Slot PCI Address(Bus/Dev/Function) MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit...
... Array Type -- SAS1068 v6.05.06.00 (2006.01.16) Adapter PCI Slot PCI Address(Bus/Dev/Function) MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit...
User Guide
Page 117
...; The disk has been selected as the Hot Spare for use in the array, press , , or . ASUS KFN32-D SLI Series 5-13 Slot Device Identifier RAID Num Disk 4 SAS HDS722580VLSA80 A63A [No] 5 FUJITSU MAX3147RC 0104 [No] 6 SAS HDS722580VLSA80 A63A [No] 7 SAS HDS722580VLSA80 A63A [No] Hot Spr [No] [No] [No] [No] Drive Status Pred Fail --------- Make sure the...
...; The disk has been selected as the Hot Spare for use in the array, press , , or . ASUS KFN32-D SLI Series 5-13 Slot Device Identifier RAID Num Disk 4 SAS HDS722580VLSA80 A63A [No] 5 FUJITSU MAX3147RC 0104 [No] 6 SAS HDS722580VLSA80 A63A [No] 7 SAS HDS722580VLSA80 A63A [No] Hot Spr [No] [No] [No] [No] Drive Status Pred Fail --------- Make sure the...
User Guide
Page 119
... v6.05.06.00 (2006.01.16) Adapter PCI Slot PCI Address(Bus/Dev/Function) MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS...2. Esc = Exit Menu F1/Shift1 = Help Enter = Choose array type to select RAID Properties, then press . Use the arrow to create ASUS KFN32-D SLI Series 5-15 Use the arrow keys to 8 disks. Create IME Volume Create Integrated Mirrored Enhanced Array of 2 disks plus an optional hot spare...
... v6.05.06.00 (2006.01.16) Adapter PCI Slot PCI Address(Bus/Dev/Function) MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS...2. Esc = Exit Menu F1/Shift1 = Help Enter = Choose array type to select RAID Properties, then press . Use the arrow to create ASUS KFN32-D SLI Series 5-15 Use the arrow keys to 8 disks. Create IME Volume Create Integrated Mirrored Enhanced Array of 2 disks plus an optional hot spare...
User Guide
Page 120
... spare C = Create Array V By default, the RAID Disk field shows No before array creation. V Slot Device Identifier RAID Num Disk 4 SAS HDS722580VLSA80 A63A [Yes] 5 FUJITSU MAX3147RC 0104 [No] 6 SAS HDS722580VLSA80 A63A [Yes] 7 SAS HDS722580VLSA80 A63A [Yes] Hot Spr [No] [No] [No] [No] Drive Status Pred Fail --------- The utility creates the array. may take...
... spare C = Create Array V By default, the RAID Disk field shows No before array creation. V Slot Device Identifier RAID Num Disk 4 SAS HDS722580VLSA80 A63A [Yes] 5 FUJITSU MAX3147RC 0104 [No] 6 SAS HDS722580VLSA80 A63A [Yes] 7 SAS HDS722580VLSA80 A63A [Yes] Hot Spr [No] [No] [No] [No] Drive Status Pred Fail --------- The utility creates the array. may take...
User Guide
Page 121
...:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit Menu Enter = Select Item F1/Shift1 = Help -/+ = Change Item ASUS KFN32-D SLI Series 5-17 LSI Logic Corp MPT SAS BIOS MPTBIOS-6.05.06.00 (2005.01.16) Copyright 2000-2005 LSI Logic Corp *** RELEASE VERSION *** Press Ctrl+C to enter the...
...:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit Menu Enter = Select Item F1/Shift1 = Help -/+ = Change Item ASUS KFN32-D SLI Series 5-17 LSI Logic Corp MPT SAS BIOS MPTBIOS-6.05.06.00 (2005.01.16) Copyright 2000-2005 LSI Logic Corp *** RELEASE VERSION *** Press Ctrl+C to enter the...
User Guide
Page 122
... Create IS Volume, then press . To include this disk in the array, press , , or . V Slot Device Identifier RAID Num Disk 4 SAS HDS722580VLSA80 A63A [Yes] 5 FUJITSU MAX3147RC 0104 [No] 6 SAS HDS722580VLSA80 A63A [Yes] 7 SAS HDS722580VLSA80 A63A [Yes] Hot Spr [No] [No] [No] [No] Drive Status Pred Fail --------- Use the arrow keys to create 5. 4. Data...
... Create IS Volume, then press . To include this disk in the array, press , , or . V Slot Device Identifier RAID Num Disk 4 SAS HDS722580VLSA80 A63A [Yes] 5 FUJITSU MAX3147RC 0104 [No] 6 SAS HDS722580VLSA80 A63A [Yes] 7 SAS HDS722580VLSA80 A63A [Yes] Hot Spr [No] [No] [No] [No] Drive Status Pred Fail --------- Use the arrow keys to create 5. 4. Data...
User Guide
Page 124
... Adapter Properties -- SAS1068 v6.05.06.00 (2006.01.16) Adapter PCI Slot PCI Address(Bus/Dev/Function) MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit...
... Adapter Properties -- SAS1068 v6.05.06.00 (2006.01.16) Adapter PCI Slot PCI Address(Bus/Dev/Function) MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit...
User Guide
Page 125
... Identifier Num 4 SAS HDS722580VLSA80 A63A 5 SAS HDS722580VLSA80 A63A 7 SAS HDS722580VLSA80 A63A RAID Disk Yes Yes Yes Hot Drive Spr Status No Ok No Ok No Ok Pred Fail No No No Size (MB) 78200 78200 78200 Esc = Exit Menu Alt+D = Device Properties F1/Shift1 = Help Alt+N = Next Array Alt+M = More Keys ASUS KFN32-D SLI Series 5-21...
... Identifier Num 4 SAS HDS722580VLSA80 A63A 5 SAS HDS722580VLSA80 A63A 7 SAS HDS722580VLSA80 A63A RAID Disk Yes Yes Yes Hot Drive Spr Status No Ok No Ok No Ok Pred Fail No No No Size (MB) 78200 78200 78200 Esc = Exit Menu Alt+D = Device Properties F1/Shift1 = Help Alt+N = Next Array Alt+M = More Keys ASUS KFN32-D SLI Series 5-21...
User Guide
Page 126
... 1. Follow steps 1 ~ 3 of 1 Identifier LSILOGIC Logical Volume 3000 Type IME Scan Order 4 Size (MB) 117301 Status Optimal Manage Array Slot Device Identifier Num 4 SAS HDS722580VLSA80 A63A 5 SAS HDS722580VLSA80 A63A 7 SAS HDS722580VLSA80 A63A RAID Disk Yes Yes Yes Hot Drive Spr Status No Ok No Ok No Ok Pred Fail No No No Size...
... 1. Follow steps 1 ~ 3 of 1 Identifier LSILOGIC Logical Volume 3000 Type IME Scan Order 4 Size (MB) 117301 Status Optimal Manage Array Slot Device Identifier Num 4 SAS HDS722580VLSA80 A63A 5 SAS HDS722580VLSA80 A63A 7 SAS HDS722580VLSA80 A63A RAID Disk Yes Yes Yes Hot Drive Spr Status No Ok No Ok No Ok Pred Fail No No No Size...
User Guide
Page 127
...Status Optimal Manage Hot Spare Synchronize Array Activate Array Delete Array Esc = Exit Menu Enter = Select Item F1/Shift1 = Help ASUS KFN32-D SLI Series 5-23 Use the arrow key to select the disk you would want to configure as hot spare, then move the ...Type Scan Order Size (MB) Status LSILOGIC Logical Volume 3000 1M 4 78201 Optimal V Slot Device Identifier Num 4 SAS HDS722580VLSA80 A63A 5 FUJITSU MAX3147RC 0104 6 SAS HDS722580VLSA80 A63A 7 SAS HDS722580VLSA80 A63A Hot Spr [No] [No] [No] [Yes] Drive Status Primary --------Secondary Hot Spare Pred Fail No...
...Status Optimal Manage Hot Spare Synchronize Array Activate Array Delete Array Esc = Exit Menu Enter = Select Item F1/Shift1 = Help ASUS KFN32-D SLI Series 5-23 Use the arrow key to select the disk you would want to configure as hot spare, then move the ...Type Scan Order Size (MB) Status LSILOGIC Logical Volume 3000 1M 4 78201 Optimal V Slot Device Identifier Num 4 SAS HDS722580VLSA80 A63A 5 FUJITSU MAX3147RC 0104 6 SAS HDS722580VLSA80 A63A 7 SAS HDS722580VLSA80 A63A Hot Spr [No] [No] [No] [Yes] Drive Status Primary --------Secondary Hot Spare Pred Fail No...
User Guide
Page 129
...Logic MPT Setup Utility v6.05.06.00 (2006.01.16) Manage Array -- From the Adapter Properties screen, select SAS Topology. SAS1068 Identifier LSILOGIC Logical Volume 3000 Type IME Scan Order 4 Size (MB) 78201 Status Optimal Manage Hot Spare...MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit Menu Enter = Select Item F1/Shift1 = Help -/+ = Change Item ASUS KFN32-D SLI Series 5-25 ...
...Logic MPT Setup Utility v6.05.06.00 (2006.01.16) Manage Array -- From the Adapter Properties screen, select SAS Topology. SAS1068 Identifier LSILOGIC Logical Volume 3000 Type IME Scan Order 4 Size (MB) 78201 Status Optimal Manage Hot Spare...MPT Firmware Revision SAS Address Status Boot Order Boot Support RAID Properties SAS Topology Advanced Adapter Properties SAS1068 00 07:03:00 0.07.01.00-IR 00000007:00000008 Enabled 0 [Enabled BIOS & OS] Esc = Exit Menu Enter = Select Item F1/Shift1 = Help -/+ = Change Item ASUS KFN32-D SLI Series 5-25 ...
User Guide
Page 136
... nVIDIA nForce MCP55 RAID for Windows XP 64 bit Driver Disk D) Create LSI 1068 SAS for RHEL WS4.0 UP2 64 bit Driver Disk E) Create LSI 1068 SAS for RHEL WS4.0 UP2 32 bit Driver Disk F) Create LSI 1068 SAS for RHEL WS3.0 UP6 64 bit Driver Disk G) Create LSI 1068...operating system on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk You may have to use another system to H: ASUS KFN32-D SLI Series 6- Restart the computer. 5. Loading FreeDOS FAT KERNEL GO! Restart the computer, then enter the BIOS Setup. 3. The Makedisk menu appears. 6.1 RAID...
... nVIDIA nForce MCP55 RAID for Windows XP 64 bit Driver Disk D) Create LSI 1068 SAS for RHEL WS4.0 UP2 64 bit Driver Disk E) Create LSI 1068 SAS for RHEL WS4.0 UP2 32 bit Driver Disk F) Create LSI 1068 SAS for RHEL WS3.0 UP6 64 bit Driver Disk G) Create LSI 1068...operating system on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk You may have to use another system to H: ASUS KFN32-D SLI Series 6- Restart the computer. 5. Loading FreeDOS FAT KERNEL GO! Restart the computer, then enter the BIOS Setup. 3. The Makedisk menu appears. 6.1 RAID...
User Guide
Page 140
... and displays a New Hardware Found window. Setup then proceeds with Administrator privileges. 2. Right-click the My Computer icon on an existing Windows® XP OS: 1. ASUS KFN32-D SLI Series 6- To an existing Windows® XP OS To install the RAID controller driver on the Windows® desktop , then select Properties from the RAID... from the menu. 4. When prompted, press to continue installation. 7. Restart the computer, then log on with the OS installation. For LSI1068 controller driver, select LSI1068 SAS RAID Controller for Windows XP OS. 6.
... and displays a New Hardware Found window. Setup then proceeds with Administrator privileges. 2. Right-click the My Computer icon on an existing Windows® XP OS: 1. ASUS KFN32-D SLI Series 6- To an existing Windows® XP OS To install the RAID controller driver on the Windows® desktop , then select Properties from the RAID... from the menu. 4. When prompted, press to continue installation. 7. Restart the computer, then log on with the OS installation. For LSI1068 controller driver, select LSI1068 SAS RAID Controller for Windows XP OS. 6.