User Manual and Install Guide
Page 21
... LEDs Diagnostic LEDs Audible Alarm Drive Activity LED connectors for CN1/CN0 CN0 CN1 2 external SAS connectors Mounting bracket Battery connector PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors, external Maximum...per port 8 512 MB DDR2 2 mini-SAS x4 (SFF-8088) 8 direct-attached (or up to 256 with these features: Ext. Chapter 3: About Your RAID Controller ● 20 About the Adaptec RAID 5085 The Adaptec RAID 5085 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose ...
... LEDs Diagnostic LEDs Audible Alarm Drive Activity LED connectors for CN1/CN0 CN0 CN1 2 external SAS connectors Mounting bracket Battery connector PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors, external Maximum...per port 8 512 MB DDR2 2 mini-SAS x4 (SFF-8088) 8 direct-attached (or up to 256 with these features: Ext. Chapter 3: About Your RAID Controller ● 20 About the Adaptec RAID 5085 The Adaptec RAID 5085 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose ...
User Manual and Install Guide
Page 22
... 3: About Your RAID Controller ● 21 About the Adaptec RAID 5405 The Adaptec RAID 5405 is a SAS RAID controller with these features: Drive Activity LED connectors for CN0 Drive Activity LEDs for CN0 Battery connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports...profile MD2 PCIe 1.1 x8 3 Gb/s per port 4 256 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or up to 256 with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 19) Alarm connector I2C connector for ...
... 3: About Your RAID Controller ● 21 About the Adaptec RAID 5405 The Adaptec RAID 5405 is a SAS RAID controller with these features: Drive Activity LED connectors for CN0 Drive Activity LEDs for CN0 Battery connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports...profile MD2 PCIe 1.1 x8 3 Gb/s per port 4 256 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or up to 256 with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 19) Alarm connector I2C connector for ...
User Manual and Install Guide
Page 23
...External miniSAS connector CN1 Diagnostic LEDs (back of card) Internal mini-SAS connector CN0 Battery connector Mounting bracket Aggregate Activity Audible Alarm I2C connector for CN0 PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard.../CN0 Mode 0 Flash connector Ext. Chapter 3: About Your RAID Controller ● 22 About the Adaptec RAID 5445 The Adaptec RAID 5445 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 19)
...External miniSAS connector CN1 Diagnostic LEDs (back of card) Internal mini-SAS connector CN0 Battery connector Mounting bracket Aggregate Activity Audible Alarm I2C connector for CN0 PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard.../CN0 Mode 0 Flash connector Ext. Chapter 3: About Your RAID Controller ● 22 About the Adaptec RAID 5445 The Adaptec RAID 5445 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 19)
User Manual and Install Guide
Page 24
... page 19) Chapter 3: About Your RAID Controller ● 23 About the Adaptec RAID 5805/5805Q The Adaptec RAID 5805/5805Q is a SAS RAID controller with expanders) 5805Q: 8 maxCache-compatible SSDs using any Solid State Drive on compatibility list (2TB max); Alarm connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard...
... page 19) Chapter 3: About Your RAID Controller ● 23 About the Adaptec RAID 5805/5805Q The Adaptec RAID 5805/5805Q is a SAS RAID controller with expanders) 5805Q: 8 maxCache-compatible SSDs using any Solid State Drive on compatibility list (2TB max); Alarm connector Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard...
User Manual and Install Guide
Page 25
Chapter 3: About Your RAID Controller ● 24 About the Adaptec RAID 51245 The Adaptec RAID 51245 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 19) Alarm Aggregate Activity Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial...
Chapter 3: About Your RAID Controller ● 24 About the Adaptec RAID 51245 The Adaptec RAID 51245 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 19) Alarm Aggregate Activity Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial...
User Manual and Install Guide
Page 26
...compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors, Internal Connectors, External Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Full Height, Half Length PCIe 1.1 x8 3 Gb/s per port 20 512 MB DDR2 4 mini-SAS x4 (SFF-8087) 1 mini-SAS...-SAS connectors CN2 CN3 Battery connector Reserved Ext. Chapter 3: About Your RAID Controller ● 25 About the Adaptec RAID 51645 The Adaptec RAID 51645 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery...
...compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors, Internal Connectors, External Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Full Height, Half Length PCIe 1.1 x8 3 Gb/s per port 20 512 MB DDR2 4 mini-SAS x4 (SFF-8087) 1 mini-SAS...-SAS connectors CN2 CN3 Battery connector Reserved Ext. Chapter 3: About Your RAID Controller ● 25 About the Adaptec RAID 51645 The Adaptec RAID 51645 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Battery...
User Manual and Install Guide
Page 27
...compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors, Internal Connectors, External Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Full Height, Half Length PCIe 1.1 x8 3 Gb/s per port 28 512 MB DDR2 6 mini-SAS x4 (SFF-8087) 1 mini-SAS...CN1 CN6 1 external mini-SAS connector CN2 CN3 6 internal mini-SAS connectors Battery connector Reserved Ext. Chapter 3: About Your RAID Controller ● 26 About the Adaptec RAID 52445 The Adaptec RAID 52445 is a SAS RAID controller with expanders) I2C and SGPIO (...
...compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors, Internal Connectors, External Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Full Height, Half Length PCIe 1.1 x8 3 Gb/s per port 28 512 MB DDR2 6 mini-SAS x4 (SFF-8087) 1 mini-SAS...CN1 CN6 1 external mini-SAS connector CN2 CN3 6 internal mini-SAS connectors Battery connector Reserved Ext. Chapter 3: About Your RAID Controller ● 26 About the Adaptec RAID 52445 The Adaptec RAID 52445 is a SAS RAID controller with expanders) I2C and SGPIO (...
User Manual and Install Guide
Page 28
...9679; 27 About the Adaptec RAID 5405Z The Adaptec RAID 5405Z is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec ZMM-100DB daughterboard (pre-installed), Adaptec ZMM-100CC supercapacitor module (...user installed-see page 48) Alarm connector Aggregate Activity Mode 0 Flash connector Diagnostic LEDs Internal mini-SAS connector CN0 PCIe x8 connector Mounting bracket ZMM-100CC Supercapacitor connector ZMM-100DB Daughterboard Form Factor Bus compatibility...
...9679; 27 About the Adaptec RAID 5405Z The Adaptec RAID 5405Z is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec ZMM-100DB daughterboard (pre-installed), Adaptec ZMM-100CC supercapacitor module (...user installed-see page 48) Alarm connector Aggregate Activity Mode 0 Flash connector Diagnostic LEDs Internal mini-SAS connector CN0 PCIe x8 connector Mounting bracket ZMM-100CC Supercapacitor connector ZMM-100DB Daughterboard Form Factor Bus compatibility...
User Manual and Install Guide
Page 29
...Activity Mode 0 Flash connector Diagnostic LEDs Internal mini-SAS CN1 connector CN0 1 external mini-SAS connector PCIe x8 connector Mounting bracket ZMM-100CC Supercapacitor connector ZMM-100DB Daughterboard Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified ...About Your RAID Controller ● 28 About the Adaptec RAID 5445Z The Adaptec RAID 5445Z is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec ZMM-100DB daughterboard (pre-installed), Adaptec ZMM-100CC supercapacitor module (user installed-see page ...
...Activity Mode 0 Flash connector Diagnostic LEDs Internal mini-SAS CN1 connector CN0 1 external mini-SAS connector PCIe x8 connector Mounting bracket ZMM-100CC Supercapacitor connector ZMM-100DB Daughterboard Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified ...About Your RAID Controller ● 28 About the Adaptec RAID 5445Z The Adaptec RAID 5445Z is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec ZMM-100DB daughterboard (pre-installed), Adaptec ZMM-100CC supercapacitor module (user installed-see page ...
User Manual and Install Guide
Page 30
... RAID Controller ● 29 About the Adaptec RAID 5805Z/5805ZQ The Adaptec RAID 5805Z/5805ZQ is a SAS RAID controller with expanders) maxCache SSD support 5805ZQ: 8 maxCache-compatible SSDs using any Solid State Drive on compatibility list (2TB max); Alarm connector Aggregate Activity Mode 0 Flash connector Diagnostic LEDs CN1 2 internal mini-SAS connectors CN0 PCIe x8 connector Mounting...
... RAID Controller ● 29 About the Adaptec RAID 5805Z/5805ZQ The Adaptec RAID 5805Z/5805ZQ is a SAS RAID controller with expanders) maxCache SSD support 5805ZQ: 8 maxCache-compatible SSDs using any Solid State Drive on compatibility list (2TB max); Alarm connector Aggregate Activity Mode 0 Flash connector Diagnostic LEDs CN1 2 internal mini-SAS connectors CN0 PCIe x8 connector Mounting...
User Manual and Install Guide
Page 31
...9679; 30 About the Adaptec RAID 2045 The Adaptec RAID 2045 is a SAS RAID controller with these features: Aggregate Activity Mode 0 Flash connector CN1 1 external miniSAS connector Mounting bracket PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data ...transfer rate Phys (Unified Serial Ports) Standard cache Connectors, external Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Low-profile MD2 PCIe 1.1 x8 3 Gb/s per port 4 128 MB DDR2 1 mini-SAS x4 (SFF-8088) 4 direct-attached (or up to 128 with expanders...
...9679; 30 About the Adaptec RAID 2045 The Adaptec RAID 2045 is a SAS RAID controller with these features: Aggregate Activity Mode 0 Flash connector CN1 1 external miniSAS connector Mounting bracket PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data ...transfer rate Phys (Unified Serial Ports) Standard cache Connectors, external Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Low-profile MD2 PCIe 1.1 x8 3 Gb/s per port 4 128 MB DDR2 1 mini-SAS x4 (SFF-8088) 4 direct-attached (or up to 128 with expanders...
User Manual and Install Guide
Page 32
... Battery Backup Module Low-profile MD2 PCIe 1.1 x8 3 Gb/s per port 4 128 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or up to 128 with expanders) 2405Q: 8 maxCache-compatible SSD using any Solid State Drive on compatibility list (80GB max); see www.adaptec.com/compatibility I2C and SGPIO (Serial General Purpose Input/Output) No No
... Battery Backup Module Low-profile MD2 PCIe 1.1 x8 3 Gb/s per port 4 128 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or up to 128 with expanders) 2405Q: 8 maxCache-compatible SSD using any Solid State Drive on compatibility list (80GB max); see www.adaptec.com/compatibility I2C and SGPIO (Serial General Purpose Input/Output) No No
User Manual and Install Guide
Page 33
...; 32 About the Adaptec RAID 2805 The Adaptec RAID 2805 is a SAS RAID controller with these features: Drive Activity LED connector for CN0/CN1 Aggregate Activity Mode 0 Flash connector Internal mini-SAS connector CN1 Internal mini-SAS connector CN0 Mounting bracket I2C, CN0 I2C, CN1 PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data...
...; 32 About the Adaptec RAID 2805 The Adaptec RAID 2805 is a SAS RAID controller with these features: Drive Activity LED connector for CN0/CN1 Aggregate Activity Mode 0 Flash connector Internal mini-SAS connector CN1 Internal mini-SAS connector CN0 Mounting bracket I2C, CN0 I2C, CN1 PCIe x8 connector Form Factor Bus compatibility PCIe bus width Data...
User Manual and Install Guide
Page 34
...Your RAID Controller ● 33 About the Adaptec RAID 6405 The Adaptec RAID 6405 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (optional; Alarm... connector Aggregate Activity HDA mode connector Diagnostic LEDs Activity LEDs (back of card) Daughterboard connector Internal mini-SAS PCIe x8 connector connector CN0 Mounting bracket Form Factor Bus compatibility...
...Your RAID Controller ● 33 About the Adaptec RAID 6405 The Adaptec RAID 6405 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (optional; Alarm... connector Aggregate Activity HDA mode connector Diagnostic LEDs Activity LEDs (back of card) Daughterboard connector Internal mini-SAS PCIe x8 connector connector CN0 Mounting bracket Form Factor Bus compatibility...
User Manual and Install Guide
Page 35
...HDA mode connector Diagnostic LEDs Drive Activity LEDs (back of card) CN1 1 external mini-SAS connector Daughterboard connector Internal mini-SAS PCIe x8 connector connector CN0 Mounting bracket Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors Maximum ... Activity LED connector for CN0 I2C connector for CN0 Ext. Chapter 3: About Your RAID Controller ● 34 About the Adaptec RAID 6445 The Adaptec RAID 6445 is a SAS RAID controller with expanders) SES, I2C, and SGPIO (Serial General Purpose Input/Output) Yes...
...HDA mode connector Diagnostic LEDs Drive Activity LEDs (back of card) CN1 1 external mini-SAS connector Daughterboard connector Internal mini-SAS PCIe x8 connector connector CN0 Mounting bracket Form Factor Bus compatibility PCIe bus width Data transfer rate Phys (Unified Serial Ports) Standard cache Connectors Maximum ... Activity LED connector for CN0 I2C connector for CN0 Ext. Chapter 3: About Your RAID Controller ● 34 About the Adaptec RAID 6445 The Adaptec RAID 6445 is a SAS RAID controller with expanders) SES, I2C, and SGPIO (Serial General Purpose Input/Output) Yes...
User Manual and Install Guide
Page 36
...adaptec.com/ compatibility. I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (6805: optional, sold separately; 6805Q: standard, pre-installed) Alarm connector Drive Activity LEDs Aggregate Activity (back of card) HDA mode connector Diagnostic LEDs CN1 CN0 Daughterboard connector PCIe x8 connector 2 internal mini-SAS.... Chapter 3: About Your RAID Controller ● 35 About the Adaptec RAID 6805/6805Q The Adaptec RAID 6805/6805Q is a SAS RAID controller with expanders) 6805Q: Up to 256 with these features: Drive Activity LED connector...
...adaptec.com/ compatibility. I2C and SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (6805: optional, sold separately; 6805Q: standard, pre-installed) Alarm connector Drive Activity LEDs Aggregate Activity (back of card) HDA mode connector Diagnostic LEDs CN1 CN0 Daughterboard connector PCIe x8 connector 2 internal mini-SAS.... Chapter 3: About Your RAID Controller ● 35 About the Adaptec RAID 6805/6805Q The Adaptec RAID 6805/6805Q is a SAS RAID controller with expanders) 6805Q: Up to 256 with these features: Drive Activity LED connector...
User Manual and Install Guide
Page 39
... Adaptec RAID 6405T The Adaptec RAID 6405T is a SAS RAID controller with expanders) SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (optional; sold separately) Alarm connector HDA mode connector Aggregate Activity Drive Activity LED connector for CN0 Diagnostic/Activity LEDs Daughterboard PCIe x8 connector connector Mounting bracket Form Factor Bus compatibility...
... Adaptec RAID 6405T The Adaptec RAID 6405T is a SAS RAID controller with expanders) SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (optional; sold separately) Alarm connector HDA mode connector Aggregate Activity Drive Activity LED connector for CN0 Diagnostic/Activity LEDs Daughterboard PCIe x8 connector connector Mounting bracket Form Factor Bus compatibility...
User Manual and Install Guide
Page 40
See the maxCache compatibility list at www.adaptec.com/ compatibility. Chapter 3: About Your RAID Controller ● 39 About the Adaptec RAID 6805T/6805TQ The Adaptec RAID 6805T/6805TQ is a SAS RAID controller with expanders) 6805TQ: Up to eight solid state drives, 1TB capacity, max. SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (6805T: optional...
See the maxCache compatibility list at www.adaptec.com/ compatibility. Chapter 3: About Your RAID Controller ● 39 About the Adaptec RAID 6805T/6805TQ The Adaptec RAID 6805T/6805TQ is a SAS RAID controller with expanders) 6805TQ: Up to eight solid state drives, 1TB capacity, max. SGPIO (Serial General Purpose Input/Output) Yes Adaptec Flash Backup Module AFM-600 (6805T: optional...